Sineson PPT

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 34

Powerful Output Power 300W(Max.

Spark Free
Technology Intensive RF Device
CET, RET & Multipolar for face & body
Ideal 470KHZ Freq.
K1med.com

What is RF diathermy?

100KHz (High Frequency Current, HFC)


Same as Radio Frequency Range → Radio Frequency → RF

SINESON 470KHZ

60Hz 100kHz 550-1550kHz 54-880Mhz

Household Muscle and Electrosurgery Radio Television


Appliances Nerve Stimulation
200kHz-3.3Mhz
Ceases
K1med.com

RF Diathermy SINESON 470KHZ

Over 100KHz (High Frequency Current, HFC) AC(Alternating current)


Same as Radio Frequency Range → Radio Frequency → RF

Low Frequency signal High Frequency signal


(Wavelength is long) (Wavelength is short)

Ionic motion, Electrochemical reaction, electrolytic reaction muscle contraction


K1med.com

470KHZ

Electron Activity 470,000 times/sec


K1med.com

Why 470KHZ?

Activate Collagen II & Collagen IV


40℃, 42 ℃, 43 ℃
Collagen II ≒ Collagen IV
With 470KHZ (LESS 500KHZ)

Generated right after treatment and working for 10 days

Activate
37 ℃ Collagen I & Collagen III
With 470KHZ (LESS 500KHZ)

Generated 25days later after treatment and working for 6 months


K1med.com

Why 470KHZ?

Collagen
Rate

Collagen II & Collagen I or


Collagen IV Collagen III

Lasting for
6 months

RF RF RF
Treatment Treatment Treatment

10days 10days 10days


K1med.com

470KHZ

RF = Diathermy = Dia(Through)+Thermy(Heat)

Convertive heat – molecular vibration and their friction


K1med.com

CET & RET

CET Capacitive Electrode Transfer RET Resistive Electrode Transfer

Face care, Hair loss care, Back, Visceral fat,


Like Capacitor Subcutaneous fat care etc. Cellulite care etc.

Non conductive electrode – Insulated electrode Conductive electrode – Non insulated electrode
INDUCED CURRENT Direct CURRENT with less dispersion of energy
Go into deeper than CET but narrow part
K1med.com

Output power comparison


with other RF Devices

300

SINESON : 300W (80V X 3.75A) 250

“S” : 200W 200

“C” : 200W
150
“W” : 150W
* ”S” “C” and “W” : Other brands’ RF device. 100

50

0
SINESON S C W

Loaded impedance – 100ohm


K1med.com

Constant Current

V(Voltage) Pressure at the end of hose

Ohm’s Law
I(Current-Ampere) Speed of water flow
V=IR

R(Resistaance-Ω) Thickness of hose


K1med.com

Power Factor is almost1(almost no reactive power)

VA (324) = Voltage (215.21) * Electric current (1.504)

Output power (Watt) 320.7W = VA (324) * COS Θ (0.99)

*COS Θ = Power Factor

Output power : 320.7W

Voltage : 215.2V

Electric Current : 1.504A

Power Factor : 0.990 θ cos


K1med.com

Heating Amount, Depth

Heating amount and heat generating depth decided by Current, Operating time,
Tissue & electrode impedance

50W 300W
K1med.com

RF Power generator

= Automobile engine
K1med.com

SMPS is Power Supplier like engine of


Automobile
K1med.com

SMPS comparison with 200W RF Device

SINESON 300W

Other brand 200W


K1med.com

Treating fat person is similar like


treating obesity person
K1med.com

Which car do you select to climb hill?


K1med.com

Monopolar & Bipolar

Mono Polar RF Bi Polar RF

Single Electrode Multi Electrode


Random Diffusion Target Diffusion
K1med.com

Biological effect of RF Diathermy

Increasing core body temperature up as much 5℃ - 7℃

Expansion of artery and capillary

Increasing blood flow rate as 4~5times

Increase in Increase in Stimulation of Increase in Removal of


O₂ supply Nutrition supply Immune system Metabolism Waste material

Body Fat Collagen


Obesity Care
combustion Re composition

Treatment good for Beauty as well as Health


K1med.com

Effective Lymph drainage

LYMPH FLOW

The arrow show the directions in which the skin


Should be brushed to improve the lymphatic drainage.

* Red dots indicate lymph nodes


K1med.com

Increasing blood flow rate as 4~5times


than normal

It is same result after exercise


K1med.com

Various Application

wrinkle removing, lifting, soften skin texture, Acne, Rheumatology, Pain(back, shoulder…),
Face care Return to normal skin from sensitive skin Pain care Tennis elbow, ankle pain

Body care fat burning, lifting, cellulite care, stretch mark


K1med.com

EFFECT ON SKIN

Sagging skin After


SINESON
CARE Perfect structural
arrangement
Elastin

Collagen

Damage old weak collagen

Activate a generating neo collagen and elastin

Skin tightening, lifting, thicker dermis layer effect


K1med.com

EFFECT ON FAT

From41℃ : Adipocyte start to melt, burning fat Discharged by sweat, urine


EFFECT ON CELLULITE

Epidermis

Dermis

Fibrous Septae

Excessive accumulation
Subcutaneous fat
of fat

Soft tissue
EFFECT ON HAIR LOSS

1’st: relax knotted muscle in back and shoulder 2’nd: treat hair scalp directly with CET monopolar RF

After 20 sessions treatment for 10 weeks:


Hair quantity, Hair pore quantity, Hair thickness is improved around 10 to 30% better than comparison group.

※Test group: Normal hair loss care + RF care Comparison group: Normal hair loss care
EFFECT ON EYE

Dark circle
Expediting generation of cells by enough blood inflow to eyelids and lymph circulation, eye-care discharges
toxic matters and removes the dark circle.

Eye edema
Eye edema by accumulation of fatigue and tired eyes by eye muscle tension and hypofunction of lacrimal
glands can be cured by the eye-care.
K1med.com

Why SINESON is the ideal RF. Device

1. Powerful output power 300W - Guaranty fast and enough heating amount

Stable and powerful RF output power from technology-intensive 300W output board (Max.).
This stable high output power enables safe and competent treatment regardless of size of electrodes. Because
there is no sudden temperature drop even with RET 80mm, it helps safe and effective treatment with high power.

In case of high obesity, you can’t expect satisfactory treatment result


with insufficient RF output power. Although a person who has high
impedance index caused by fat, feels tepid temperature (less 40°C)
after slowly temperature increase with low RF power device, SINESON with
intensive RF output power satisfies her/his demand through visible effects.
K1med.com

Why SINESON is the ideal RF. Device

2. Double treatment at the same time

Time saving treatment with synergy effects.

2 RET 60mm electrodes can be installed 2 handles from SINESON main unit.
2 Handles enable treatments on two local areas at the time.
It helps to reduce treatment time and thermal losses.
*Especially recommend for wide area treatment ex.) Sides, Abdomen, back and so on.
K1med.com

Why SINESON is the ideal RF. device

3. Spark free treatment

Safe treatment without burn issue.


SINESON has qualified Spark detector program which has been verified through *NOSPAK
→There are many low range RF devices just increasing power without safety part so it causes frequent RF problem like spark and burn.
*NOSPAK is one of the best selling item in K1MED. It has been sold from 2013

4. User friendly interface with 7Inch Color Touch Screen

Modern and convenient U.I.(User Interface) and color LCD.


Specially designed LCD is fully protected from possible problems caused by RF noise.

5. High durability

Long lasting SINESON without minor problems.


Power factor is almost reach 1. That means, SINESON minimizes thermal losses and maximizes electrical efficiency
by adopting safe static type. Protective devices and programs against over voltage, over flow and over thermal,
momentary down the system to minimize components’ damage.
In addition, SINESON has high current efficiency. The compact designed output sector of SINESON reduces power loss.
Basic Accessory
TYPE SIZE QUANTITY
CET ELECTRODE 20mm 1
30mm 1
40mm 1
60mm 1
80mm 1
RET ELECTRODE 30mm 1
60mm 1
80mm 1
Cover for RET handle 60mm 1
Handle for CET 1
Handle for RET 1
Bipolar Handle 1
Patient Plate 1
Patient Bar 1
K1med.com

Basic Accessory

CET

80mm 60mm 40mm 30mm 20mm

RET

80mm 60mm 30mm Cover for RET handle

Patient Bar
Bipolar Patient
with cable Plate
K1med.com

Optional Accessory
Y type cable

CET 60 RET 60

RET H/P – 1 PC, CET H/P 1 PC

Cover for RET 60


Thank you

Add. Rm.205.Woolim e-biz center II, 12, Digital-ro 33-gil, Guro-gu, Seoul, Korea
(08377)
Tel. +82-2-871-0657 / Fax. +82-2-871-0658 / Url.
www.k1med.com
E-mail. k1global@k1med.com

You might also like