CALCULATION OF SHEAR CAPACITY FOR SECTIONS SUBJECTED TO AXIAL,FLEXURE

AND SHEAR FORCES


Project No: SH1313
Project Name : OMIS Tower
Column No: P3B

Basic Inputs

Section Data Material Properties Reinf. Ratio(As/(bwxd)


B : width of section (mm) = 300 Fc`(N/mm2) = 60 Rw (%) = 0.31
H : depth of section (mm) = 11600 Fy (N/mm2) = 420
d: effective depth(mm) 9280 Phi = 0.75

Straining actions
Vu maximum shear in Long Dir. (KN) = 6910 Pu (KN) = 4568 Mu(KN.m)=
### 8742

STEP 1- Calculate Vc considering (Shear+Flexure+Compression)


Vc= (0.16 * fc`^0.5 + 17 Rw * Vu * d/Mm) * B * d
where:-
Rw=Reinf.ratio at tension side = 0.0031
Mm = Mu - Nu * (4*H-d)/ 8 = -12453.52 KN.m Negative

If Mm is possitive then :
Vc = (0.16 * fc`^0.5 + 17* Rw * Vu*d /Mm) = 0.967995492 Mpa <vcmax eqn (1)

If Mm is Nagative then :
Vc = 0.17 * (1+ Nu/(14*Ag))fc`^0.5 = 1.440279196 Mpa <vcmax eqn(2)

check vc (max) = 0.29 * fc`^0.5 * (1+ 0.29 * Nu/Ag)^0.5 = 2.639478 Mpa

From eqn(1) & (2) , vc = #VALUE! Mpa

STEP 2- Check of maximum shear Force that can be carried by the Section
Maximum shear force can be carried by concrete Vc = vc * B * d #VALUE! KN
Maximum shear force can be carried by Reinf. Vs(max)=0.66(fc`)^0.5 *B*d = 14232.74904 KN
total shear force can be carried by both(concrete+Reinforcement) =(Vc+Vs)phi = #VALUE! KN
#VALUE!

STEP 3- Calculation of shear force carried by Reinforcement.

Vs = (Vu - Vc * phi) = #VALUE! KN #VALUE!

Av/s = Vs/(Fy*d*phi) = #VALUE! mm2/mm


#VALUE! cm2/cm

Khatib Alami, CEC


Vu*d/Mm= -5.149130527 -5.149130526951

#VALUE!