Moment of inertia calculation for Compression Members (columns)

according to ACI318M-11 (item 10.10.4.1) :-

For "rectangular or square " column :- column at axis A&1

important Note:- Pu &Mu22&Mu33&RFT% should be from last run and at the critical combination

input data Remark

column width b = = 800 mm

column depth t= = 800 mm

ultimate normal force at considered floor Pu = 47 ton

ultimate moment at considered floor Mu22 = 47 t.m. as per column

ultimate moment at considered floor Mu33 = 100 t.m. local axis in etabs

Fy = = 460 N/mm2

fc' = = 40 N/mm2

column rft ratio (from last etabs design which modifier = 0.7 ) = 1.17 ٪

output data

Area of section (Ag ) =bxt = 640000.00 mm2

Area of reinforcement Ast = = 7488.00 mm2

Po nominal axial load strength at zero ecc. = 0.85Fc'(Ag-Ast) + (Fy*Ast) = 2494.99 ton

I22 = ( (0.8)+(25*(Ast/Ag)) ) ( 1- (Mu22/(pu*b)) - ((0.5*Pu)/P0) ) = -0.28 equ 10-8

I33 = ( (0.8)+(25*(Ast/Ag)) ) ( 1- (Mu33/(pu*t)) - (0.5*Pu/P0) ) = -1.82 equ 10-8

I22used for etabs model = 0.35 0.35<=I<=0.7

I33used for etabs model = 0.35 0.35<=I<=0.7


Moment of inertia calculation for Compression Members (columns)

according to ACI318M-11 (item 10.10.4.1) :-

For Circular column :- column at axis A&1

important Note:- Pu &Mu22&Mu33&RFT% should be from last run and at the critical combination

input data Remark

column diameter D = = 1300 mm

ultimate normal force at considered floor Pu = 362.3 ton

ultimate moment at considered floor Mu = 406 t.m. as per column

Fy = = 460 N/mm2 local axis in etabs

fc' = = 40 N/mm2

column rft ratio (from last etabs design which modifier = 0.7 ) = 1.47 ٪

output data

Area of section Ag = = 1326650.00 mm2

Area of reinforcement Ast = = 19501.76 mm2

Po nominal axial load strength at zero ecc. = 0.85Fc'(Ag-Ast) + (Fy*Ast) = 5341.38 ton

I22 = I33 = ( (0.8)+(25*(Ast/Ag)) ) ( 1- (Mu/(pu*D)) - ((0.5*Pu)/P0) ) = 0.12 equ 10-8

I22 = I33 used for etabs model = 0.35 0.35<=I<=0.7


Date Version Action BY

23-1-2013 Moment of inertia for Compression Members (columns) Rev 00 M.EZZ

05-2-2013 Moment of inertia for Compression Members (columns) Rev 01 M.EZZ


Moment of inertia I of compression & flexural members

can be taken from the following values or calculated as per the above equations

compression members :-

columns 0.7

walls-uncracked 0.7

walls-cracked 0.35

flexural members :-

Beams 0.35

flat plates & flat slabs 0.25

Ig =bt^3/12 #REF! m4

Pu &Mu22 to be taken from the same section location


Pu &Mu33 to be taken from the same section location

φ= Po factor
Tied stirrup = 0.65 0.8
spiral stirrup = 0.75 0.85
FOR vertical member
m2-2 = MOMENT ARROUND AXIS 2-2
m3-3 =MOMENT ARROUND AXIS 3-3

φ= Po factor
Tied stirrup = 0.65 0.8
spiral stirrup = 0.75 0.85

FOR vertical member


m2-2 = MOMENT ARROUND AXIS 2-2
m3-3 =MOMENT ARROUND AXIS 3-3
1st equ ( 1.2D+0.5Ln+Lg+Exa) &2nd equ ( 1.2D+0.5Ln+Lg-Exa) &3rd equ ( 1.2D+0.5Ln+Lg+Eya) 4th equ ( 1.2D+0.5Ln+Lg-Eya)

5th equ ( 1.2D+0.5Ln+Lg+Exb) &6th equ ( 1.2D+0.5Ln+Lg-Exb) &7th equ ( 1.2D+0.5Ln+Lg+Eyb) 8th equ ( 1.2D+0.5Ln+Lg-Eyb)

You might also like