Tender Drawings: Interior Rennovation at Iocl Karnal (A.O Building)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

2'-3"

4'-2"

MANAGER ROOM 1
11'-0"X14'-6"

2'-11" 2'-11" 4'-2" 4'-2"

2'-3"
SR. AREA MANAGER
22'-3"X22'-3"

2'-11"

4'-2"

2'-11"
TOILET

2'

BOARD ROOM
3'-8"
22'-3"X17'-4"

WAITING

STORE
7'-3"X6'-8" 3'-3"
4'-9" 3'-3"

3'-5" 2'-11" 4'-2" 4'-2"


PANTRY

2' EQ

6'-0" WIDE PASSAGE 2'


EQ 3'-8"
2'-6"

EQ 2EQ 2EQ 2EQ EQ

18'
2' 2'-2"
2' TENDER DRAWINGS
TRAINING ROOM
34'-8"X27'-6"
MANAGER ROOM 3 MANAGER ROOM 2 2'
26' 11'-0"X14'-6" 11'-3"X14'-6" 2' CUBICLE
4'-4" 4'-4"
2' 11'-2"X8'-6"

2'-6"
2'-6"
Revisions :

2'-8" 2'-8"
4'-9"
MEP CONSULTANTS
2'-2" 2'-2"

SARTHAK BUILDING ENGINEERING

S.
NO. SYMBOL DESCRIPITION

1 SWITCH BOARD
2 20W LED DOWN LIGHT Project Management Consultant :

3 18W CEILING LIGHT


4 12W CEILING LIGHT
5 2'-0"x 2'-0" RECESSED TYPE LED PANEL LIGHT Job Title :
INTERIOR RENNOVATION AT IOCL KARNAL
6 9W MIRROR LIGHT (A.O BUILDING)
7 6AMP FOR EX FAN Drawing Title :
EL-LIGHT POINT DIMENSION LAYOUT
8 EXHAUST FAN FIRST FLOOR PLAN

9 20W SURFACE MOUNTED CEILING LIGHT Architects :


B-33 2nd floor,Shivalik ,
New Delhi - 110017. India
10 10W BULKHEAD LIGHT
Telephone : +91-11-26691567,
26691568
11 DISTRIBUTION BOARD Fax : +91-11-41580644
E.Mail :
satishray60@rediffmail.com

Date : Chkd. By : NORTH :


17-09-2021 R.K
Scale : Dealt by :
NTS. R.K
Drg. No. :

C
MANAGER ROOM 1
11'-0"X14'-6"

SR. AREA MANAGER


22'-3"X22'-3"

TOILET

BOARD ROOM
22'-3"X17'-4"

WAITING

STORE
7'-3"X6'-8"

PANTRY

6'-0" WIDE PASSAGE

TENDER DRAWINGS
TRAINING ROOM
34'-8"X27'-6"
MANAGER ROOM 3 MANAGER ROOM 2
11'-0"X14'-6" 11'-3"X14'-6" CUBICLE
11'-2"X8'-6"

Revisions :

MEP CONSULTANTS

SARTHAK BUILDING ENGINEERING

GENERAL NOTES:-FIRE ALARM & DETECTION SYSTEM


S.
NO. SYMBOL
01. FIRE ALARM SYSTEM SHALL BE DESIGNED AS PER IS:2189/NBC-2016/NFPA-72.
DESCRIPITION ADDRESSABLE TYPE/CONVENTIONAL TYPE FIRE ALARM PANEL SHALL BE USED.

FIRE ALARM SYSTEM SHALL BE LOCATED AT GROUND FLOOR IN RECEPTION AREA.

1 SWITCH BOARD 02. ALL DEVICES SHALL BE WIRED DIRECTLY FROM THE FIRE CONTROL PANEL WITH 2x1.5 SQ.MM. CU.

Project Management Consultant :


2 20W LED DOWN LIGHT 03.
MAXIMUM 250NOS DETECTOR/DEVICES IN ANY COMBINATION SHALL BE WIRED IN ONE LOOP,
REPEATER PANEL SHALL BE LOCATED AT GUARD ROOM.

ALL DETECTORS SHALL NOT BE MOUNTED WITHIN 500MM OF ANY WALLS, PARTITIONS OR OBSTRUCTIONS

3 18W CEILING LIGHT WHERE STRUCTURAL BEAMS OR DUCT WORK FOR LIGHT FITTINGS OR ANY OTHER CEILING ATTACHMENTS
NOT GREATER THAN 250MM DEPTH.
04.
DETECTORS SHALL NOT BE MOUNTED WITHIN 1 Mtr. OF ANY SUPPLY AIR INLETS OF HVAC SYSTEM.
4 12W CEILING LIGHT ABOVE FALSE CEILING DETECTORS ARE MOUNTED ON SLAB WITH BOX AND

BELOW FALSE CEILING DETECTORS ARE MOUNTED DIRECTLY ON FALSE CEILING. IF BETWEEN F/CEILING & Job Title :
5 2'-0"x 2'-0" RECESSED TYPE LED PANEL LIGHT TRUE CEILING GAP IS MORE THAN 750mm THAN ABOVE F/C DETECTOR IS REQUIRED
INTERIOR RENNOVATION AT IOCL KARNAL
MANUAL CALL POINT SHOULD BE FIXED AT A HEIGHT OF 1.4 Mtr. FROM FINISHED FLOOR LEVEL.
MANUAL CALL POINT SHOULD BE LOCATED IN SUCH A WAY, THE TRAVEL DISTANCE SHOULD BE MAX. 30 Mtr.
(A.O BUILDING)
6 9W MIRROR LIGHT IN EXTERNAL AREA THE TRAVEL DISTANCE SHOULD BE MAX. 45Mtr.

IN EXTERNAL AREA THE TRAVEL DISTANCE SHOULD BE MAX. 45Mtr.


05. CONTROL MODULE, MONITOR MODULE AND RELAY MODULE FOR NECESSARY INTERLOCKING AND
Drawing Title :
7 6AMP FOR EX FAN AUTOMATICALLY START SMOKE EXHAUST FANS AND STARICASE / LIFT WELL PRESSURIZATION FANS AND EL-LIGHTING & FIRE DETECTION & ALARM LAYOUT
TO STOP AUTOMATICALLY AIR-CONDITIONING PLANT AND INDOOR AIR SUPPLY UNITS AND FIRE DAMPERS
ON THE DETECTION OF A FIRE SIGNAL. FIRST FLOOR PLAN
8 EXHAUST FAN ALL HOOTERS, RELAY OUTPUT MODULES SHALL BE WIRED DIRECTLY FROM THE FIRE CONTROL PANEL.

ALL DEVICES LOCATIONS ARE INDICATIVE ONLY & ACTUAL LOCATIONS WILL BE AS PER COORDINATED Architects :
RCP AND INTERIOR PLANs/ELEVATION AND AS ON SITE CONDITIONS.

9 20W SURFACE MOUNTED CEILING LIGHT THE GAP BETWEEN ELV AND ELECTRICAL CABILING SHALL BE MAINTAINED MINIMUM 300 MM.
B-33 2nd floor,Shivalik ,
New Delhi - 110017. India
06. ALL INSTALLATION AND WIRING DETAILS SHOULD BE AS PER OEM GUIDLINES.
Telephone : +91-11-26691567,
10 10W BULKHEAD LIGHT SUITABLE FLEXIBLE CONDUIT SHALL BE ARRANGED WHEREVER REQUIRED.
26691568
CONTRACTOR SHALL SUBMIT FIRE LIFE SAFETY SEQUENCE OF OPERATION OF VARIOUS EXHAUST
Fax : +91-11-41580644
AND PRESSURIZATION FANS AND AC PLANTS FOR APPROVAL TO CLIENT/ CONSULTANT BEFORE

11 DISTRIBUTION BOARD IMPLEMENTATION ON SITE.


E.Mail :
satishray60@rediffmail.com
07. HEIGHT CONSIDERATION:-

A. IF HEIGHT OF BUILDING UPTO 7Mtr. THE SPACING B/W SMOKE/MULTI DETECTOR SHALL BE 7.5Mtr.

LEGENDS:- B. IF HEIGHT OF BUILDING B/W 7Mtr. TO 10Mtr. THE SPACING B/W SMOKE/MULTI DETECTOR SHALL BE 5.0Mtr.
Date : Chkd. By : NORTH :
C. BEYOND 10Mtr. HEIGHT, BEAM DETECTOR SHALL BE USED.
SMOKE DETECTOR D. IF HEIGHT OF BUILDING UPTO 5Mtr. THE SPACING B/W HEAT DETECTOR SHALL BE 5.3Mtr. 17-09-2021 R.K
E. IF HEIGHT OF BUILDING BETWEEN 5Mtr. TO 7Mtr. THE SPACING B/W DETECTOR SHALL BE 3.5Mtr.
HEAT DETECTOR Scale : Dealt by :
NTS. R.K
RESPONSE INDICATOR
Drg. No. :
MCP

NOTE:- AS PER NORM's THERE NOT REQUIRED FIRE ALARM SYSTEM


TENDER DRAWINGS

Revisions :

MEP CONSULTANTS

SARTHAK BUILDING ENGINEERING

S.
NO. SYMBOL DESCRIPITION Project Management Consultant :

1 6A SOCKET WITH SWITCH


2 6/16A INDUSTRIAL SOCKET WITH SWITCH
THREADED ROD.
3 2Nos. 6A UPS SOCKET
ROD. Job Title :
300mm CABLE TRAY. 150mm CABLE TRAY.
4 6/16A UPS SOCKET WITH SWITCH INTERIOR RENNOVATION AT IOCL KARNAL
G.I TRUNKING 40x40mm UNISTRUT
CHANNEL
SUPPORT FOR TRAY. 5 TELEPHONE OUTLET (A.O BUILDING)
40x40mm UNISTRUT
CHANNEL 150mm CABLE TRAY
DATA OUTLET Drawing Title :
SUPPORT FOR TRAY. TO DB. 6 EL-POWER, ELV,CABLE TRAY LAYOUT
INCOMING SUBMAIN
CABLE.
INCOMING
16A SOCKET OUTLET FOR HAND DRYER FIRST FLOOR PLAN
150mm CABLE TRAY TO
SUBMAIN CABLE. 7
DB.
2x6A UPS SOCKET WITH SWITCH Architects :
CABLE GLAND.
B-33 2nd floor,Shivalik ,
1x6A RAW POWER SOCKET New Delhi - 110017. India
8 1x16A RAW POWER SOCKET
Telephone : +91-11-26691567,
DB DATA OUTLET 26691568
TELEPHONE OUTLET Fax : +91-11-41580644
E.Mail :
9 1x20A SOCKET WITH SWITCH FOR A.C satishray60@rediffmail.com

10 6A SOCKET FOR TV
Date : Chkd. By : NORTH :
11 6A SOCKET FOR TV R.K
17-09-2021
12 BELL PUSH BUTTON Dealt by :
Scale :
BELL BUZZER NTS. R.K
13
ELECTRICAL CABLE TRAY Drg. No. :
14
15 L.V CABLE TRAY
C
16 POINT FOR PROJECTOR IN CEILING

17 DISTRIBUTION BOARD
MANAGER
ROOM -1
11'-0"X14'-6"
SR. AREA MANAGER
22'-3"X22'-3"

PA

TOILET

DN UP
MALE
TOILET
4'-6"X13'-7" FEMALE
TOILET
5'-4"X8'-4"

W A I T I N G
STORE BOARD ROOM
PANTRY 22'-3"X17'-4"
TRAINING ROOM 7'-3"X6'-8"
15'-0"X6'-8"
34'-8"X27'-6"
LOW HEIGHT PARTITION

6'-0" WIDE PASSAGE

CUBICLE
11'-2"X8'-6"
MANAGER MANAGER
ROOM - 3 ROOM - 2
11'-0"X14'-6" 11'-3"X14'-6"

DN

FIRE
ESCAPE
STAIRCASE

FIRST FLOOR PLAN

ELECTRICAL ROOM STORE ROOM


23'-6"x11'-5" 10'-6"x11'-5"
WORKSTATIONS

CUBICLE 1 CUBICLE 2
7'-0"X8'-6" 7'-0"X8'-6"
4 NOS

3'-9" WIDE PASSAGE


CUBICLE 3 CUBICLE 4
7'-0"X8'-6" 7'-0"X8'-6"

DN UP
MALE
TOILET
4'-6"X13'-7" FEMALE
TOILET MANAGER ROOM - 4
5'-4"X8'-4"
17'-0"X10'-6"

RECEPTION & WAITING


SERVER/ UPS 22'-3"X17'-9"
ROOM
10'-0"X12'-0"
RECORD
ROOM MEETING ROOM
16'-0"X22'-2" 31'-0"X22'-2"

W A I T I N G

GROUND FLOOR PLAN

NOTE : ALL DIMENSIONS ARE IN FEET INCHES

DRAWING TITLE : Architects :


PROPOSED LAYOUT FOR RENOVATION OF B-33 2nd floor,Shivalik ,
New Delhi - 110017. India
AREA OFFICE BUILDING AT IOCL - KARNAL. Fax : +91-11-41580644
E.Mail :
satishray60@rediffmail.com
1.5 TR Hi Wall 1.5 TR Hi Wall
SPLIT A.C. SPLIT A.C.

2'-3"

1"
4'-12
MANAGER ROOM 1

1.5 TR Hi Wall
11'-0"X14'-6"
1" 1" 4'-11" 1"
4'-12

SPLIT A.C.
2'-102 2'-102 2

2'-3"
SR. AREA MANAGER
1.5 TR Hi Wall 22'-3"X22'-3"

1"
2'-102
SPLIT A.C.

1"
4'-12
TOILET
1"
7'-12 EQ 6'-0" EQ

2'-0"
MALE
1.5 TR HI WALL TOILET

3'-8"
4'-6"X13'-7" BOARD ROOM
SPLIT A.C. FEMALE 1" 1" 22'-3"X17'-4"
TOILET 3'-42 16'-0" 2'-102 1" 1"
5'-4"X8'-4" 4'-12 4'-12

14'-0"
3'-3" 3'-3" WAITING
EQ
1.5 TR HI WALL

PANTRY
0'-6"
15'-0"X6'-8"
STORE
SPLIT A.C.

EQ
7'-3"X6'-8" 2'-0" 2'-0"

3'-8"
TRAINING ROOM 6'-0" WIDE PASSAGE

2'-6"
EQ
34'-8"X27'-6"
EQ 2EQ 2EQ 2EQ EQ
18'-0"

2'-0"
EQ

EQ

CUBICLE 1.5 TR Hi Wall


11'-2"X8'-6" SPLIT A.C.

MANAGER ROOM 3 MANAGER ROOM 2 2'-0"


EQ 26'-0" EQ
2'-0"

11'-0"X14'-6" 11'-3"X14'-6" 2'-0" 1.5 TR Hi Wall


EQ EQ SPLIT A.C.
EQ EQ
EQ

EQ
EQ

DN

1.5 TR Hi Wall
1.5 TR HI WALL SPLIT A.C.
SPLIT A.C.

FIRST FLOOR RCP LAYOUT 2'-0"

STORE ROOM
4'-0" 4'-0" 10'-6"x11'-5"
3'-3" 3'-3"
ELECTRICAL ROOM
23'-6"x11'-5"
1.5 TR HI WALL
LEGEND:- SPLIT A/C
2'-0"

2'-0"X2'-0" RECESSED SURFACE MOUNTED


TYPE LED PANEL LIGHT CEILING LIGHT
1"
2'-102
EQ

LED DOWN LIGHT 1.5TR HI WALL SPLIT AC


1.5 TR HI WALL
WORKSTATIONS 2'-6" 2'-6" SPLIT A/C
1.5 TR HI WALL 4 NOS
10'-0"

SPLIT A/C CUBICLES 1 - 4


EQ 6'-0" EQ
EQ

1"
2'-102

MALE DN UP
1.5 TR HI WALL 1.5 TR HI WALL TOILET
EQ

4'-6"X13'-7"
SPLIT A.C. SPLIT A.C.
EQ

FEMALE
TOILET
EQ 14'-0" EQ MANAGER ROOM 4
5'-4"X8'-4"
17'-0"X10'-6"
EQ EQ
2'-3"

10'-0"
EQ
EQ

EQ

RECEPTION &
SERVER/ UPS
2'-6"

WAITING
EQ 22'-0" EQ ROOM
22'-3"X17'-9"
10'-0"X12'-0"
EQ

RECORD
ROOM 2'-3" EQ 6'-0" EQ
14'-0"

2'-3"
2EQ

2'-3" 1.5 TR HI WALL


16'-0"X22'-2"
SPLIT A/C
EQ 2EQ EQ
MEETING
ROOM
31'-0"X22'-2" WAITING
EQ

10'-0"

2'-6"
EQ

1.5 TR HI WALL SPLIT A/C


EQ EQ

EQ 2EQ 2EQ 2EQ 2EQ 2EQ EQ


2'-4"

1.5 TR HI WALL SPLIT A/C 1.5 TR HI WALL SPLIT A/C

GROUND FLOOR RCP LAYOUT NOTE : ALL DIMENSIONS ARE IN FEET INCHES

DRAWING TITLE : Architects :


PROPOSED LAYOUT FOR RENOVATION OF B-33 2nd floor,Shivalik ,
New Delhi - 110017. India
AREA OFFICE BUILDING AT IOCL - KARNAL. Fax : +91-11-41580644
E.Mail :
satishray60@rediffmail.com
DOUBLE CHARGE
VITRIFIED TILE
POLISHED FINISH MANAGER

5'-4"

5'-4"
800 X 1600 MM RM 1 2'-8"
11'-0" X 14'-6"

2'-8" SR. AREA MANAGER


22'-3"X22'-3"

2'-0"
DOUBLE CHARGE TOILET
GLAZED VITRIFIED
VITRIFIED TILE TILE MATT/ANTISKID 4'-0"
POLISHED FINISH FINISH 600 X 1200 MM
800 X 1600 MM
GLAZED VITRIFIED

2'-8"
5'-4"
TILE MATT/ANTISKID
2'-0" FINISH 600 X 1200 MM

STORE 4'-0"
7'-3"X6'-8" W A I T I N G

2'-8"
PANTRY 5'-4"
15'-0"X6'-8"
BOARD ROOM
22'-3"X17'-4"
6'-0" WIDE PASSAGE

TRAINING ROOM
34'-8" X 27'-6"
CUBICLE DOUBLE CHARGE
11'-2"X8'-6" VITRIFIED TILE
2'-8"

5'-4" MANAGER MANAGER POLISHED FINISH


RM 3 RM 2 800 X 1600 MM
11'-0"X14'-6" 11'-3"X14'-6"

DN

FIRST FLOOR FLOORING LAYOUT

5'-4"
2'-8"

DOUBLE CHARGE STORE


VITRIFIED TILE ROOM
2'-8"

ELECTRICAL
POLISHED FINISH 10'-6"x11'-5"
ROOM
800 X 1600 MM

2'-8"
5'-4" 23'-6"x11'-5" 5'-4"
2'-8"

5'-4"

WORKSTATIONS
- 4 NOS
CUBICLES 2'-8"
1-4
DOUBLE CHARGE GLAZED VITRIFIED
VITRIFIED TILE TILE MATT/ANTISKID
POLISHED FINISH DN UP 4'-6"
FINISH 600 X 1200 MM
MALE TOILET

800 X 1600 MM
4'-6"X13'-7"

FEMALE TOILET

MANAGER
2'-8"

5'-4"
5'-4"X8'-4"

ROOM 4
17'-0"X10'-6"
5'-4"

RECEPTION 2'-8"
& WAITING
SERVER/
22'-3"X17'-9"
2'-8"

2'-8"

5'-4" 5'-4" UPS ROOM


10'-0"X12'-0"
2'-8"

RECORD ROOM MEETING ROOM 5'-4"


16'-0"X22'-2" 31'-0"X22'-2"
DOUBLE CHARGE
VITRIFIED TILE
WAITING POLISHED FINISH
800 X 1600 MM
2'-8"

5'-4"

DOUBLE CHARGE
VITRIFIED TILE
POLISHED FINISH
800 X 1600 MM
GROUND FLOOR FLOORINGLAYOUT NOTE : ALL DIMENSIONS ARE IN FEET INCHES

DRAWING TITLE : Architects :


PROPOSED LAYOUT FOR RENOVATION OF B-33 2nd floor,Shivalik ,
New Delhi - 110017. India
AREA OFFICE BUILDING AT IOCL - KARNAL. Fax : +91-11-41580644
E.Mail :
satishray60@rediffmail.com