Compatibility list SIMOTION SCOUT V5.1 HF6
This compatibility list considers the combinatorics of all software products with SCOUT version
V5.1 HF6 (SIMOTION with SIMATIC STEP 7) that occur within the scope of SIMOTION.
Runtime and project versions from SIMOTION Version V4.1 were considered - including the
SIMOTION controllers that can be configured with these versions.
The older runtime and project versions V3.2 to V4.0 are no longer listed in this compatibility list,
even if they can still be configured.
Only the interaction of the individual software components with their corresponding versions as
listed in this compatibility list is guaranteed.
The compatibility list contains only versions which have been released for general use.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and
software described. Since variance cannot be precluded entirely, we cannot guarantee full
consistency. However, the information in this publication is reviewed regularly and any necessary
corrections are included in subsequent editions.
1 CHAPTER.................................................................................................................................................... 5
1.1 SCOUT <===> STEP 7....................................................................................................................... 5
1.2 SCOUT <===> Windows................................................................................................................... 5
1.3 SCOUT Stand-alone <===> STEP 7................................................................................................... 6
1.4 SCOUT Stand-alone <===> Windows............................................................................................... 6
1.5 Side-by-side: SCOUT <===> TIA Portal............................................................................................ 7
1.6 Side-by-side: SCOUT <===> SCOUT TIA.......................................................................................... 7
2 CHAPTER.................................................................................................................................................... 8
2.1 SCOUT <===> Motion Controller & Control Units................................................................................. 8
2.2 Motion Controller C230 <===> SIMOTION Kernel............................................................................ 9
2.3 Motion Controller C240 <===> SIMOTION Kernel............................................................................ 9
2.4 Control Units D4xx <===> SIMOTION Kernel.................................................................................. 10
2.4.1 Control Units D410 <===> SIMOTION Kernel.......................................................................... 10
2.4.2 Control Units D4x5 <===> SIMOTION Kernel............................................................................ 12
2.5 Control Units D4xx-2 <===> SIMOTION Kernel............................................................................... 15
2.5.1 Control Units D410-2 <===> SIMOTION Kernel....................................................................... 15
2.5.2 Control Units D4x5-2 <===> SIMOTION Kernel........................................................................ 16
2.6 Motion Controller P3x0 <===> SIMOTION Kernel........................................................................... 17
2.7 SCOUT <===> SIMOTION Kernel.................................................................................................... 18
2.8 SCOUT <===> SIMOTION project................................................................................................... 19
3 CHAPTER.................................................................................................................................................. 20
3.1 SCOUT <===> Integrated operation: S7 Technology........................................................................ 20
3.2 SCOUT <===> S7-Distributed Safety & S7-F ConfigurationPack........................................................ 21
3.3 SCOUT <===> CamTool................................................................................................................... 21
3.4 SCOUT <===> SIMOTION Simulation............................................................................................... 22
3.5 SCOUT <===> DCC.......................................................................................................................... 22
3.6 CFC <===> DCC............................................................................................................................. 23
3.7 SCOUT <===> SIMATIC NET PC Software......................................................................................... 24
3.8 OPC Server (SIMATIC NET) <===> SIMOTION Kernel....................................................................... 25
3.9 SCOUT <===> WinCC flexible ES........................................................................................................ 26
3.10 WinCC flexible RT <===> SIMOTION Kernel.................................................................................. 27
4 CHAPTER.................................................................................................................................................. 28
4.1 Technology packages <===> SIMOTION Kernel.............................................................................. 28
4.2 DCC technology packages <===> SIMOTION kernel....................................................................... 30
4.3 OA technology packages <===> SCOUT......................................................................................... 31
4.4 OA technology packages <===> SIMOTION Kernel......................................................................... 32
4.5 WebTraceViewer <===> SIMOTION Kernel..................................................................................... 33
4.6 WebTraceViewer <===> Windows.................................................................................................. 34
5 CHAPTER.................................................................................................................................................. 35
5.1 SIMOTION D supplementary boards <===> SIMOTION D................................................................ 35
5.1.1 SIMOTION D supplementary boards <===> SIMOTION D4xx................................................... 35
1 CHAPTER
In this chapter, you will find information about the interaction of different SCOUT versions, STEP7 or TIA Portal – and Windows versions.
SCOUT
SCOUT V5.1 HF6 X
SCOUT
SCOUT V5.1 HF6 X X X X X
Description
SCOUT Stand-alone
SCOUT Stand-alone V5.1 HF6 X
Description
SCOUT Stand-alone
SCOUT Stand-alone V5.1 HF6 X X X X X
SCOUT
SCOUT V5.1 HF6 X X X X X
Description
SCOUT
SCOUT V5.1 HF6 X X X X X X X X X X
2 CHAPTER
In this chapter you will find information about the interaction of Motion Controllers & Control Units, kernel versions, SCOUT versions and SIMOTION projects.
SCOUT
SCOUT V5.1 HF6 X X X X X X X X X X X X X X X X X X X X X X X X
Description
SIMOTION C230-2
SIMOTION Motion Controller C230-2.1 X X X X X X X X X
SIMOTION C240
SIMOTION Motion Controller C240 X X X X X X X X X X X X X X X X X X X X X X X X
SIMOTION Motion Controller C240 PN X X X X X X X X X X X X X X X X X X X X X X
Description
SIMOTION D410-x
SIMOTION Control Unit D410 DP X X X X X X X X X X X X X X X X
SIMOTION Control Unit D410 PN X X X X X X X X X X X X X X X X
Description
SIMOTION D410-x
SIMOTION Control Unit D410 DP X X X X X X X
SIMOTION Control Unit D410 PN X X X X X X X
SIMOTION D425-x
SIMOTION Control Unit D425 X X X X X X X X X X X X X X X X
SIMOTION D435-x
SIMOTION Control Unit D435 (6AU1435-0AA00-0AA1) X X X X X X X X X X X X X X X X
SIMOTION D445-x
SIMOTION Control Unit D445 X X X X X X X X X X X X X X X X
SIMOTION Control Unit D445-1 X X X X X X X
Description
SIMOTION D425-x
SIMOTION Control Unit D425 X X X X X X X X X X X X X X X X
SIMOTION D435-x
SIMOTION Control Unit D435 (6AU1435-0AA00-0AA1) X X X X X X X X X X X X X X X X
SIMOTION D445-x
SIMOTION Control Unit D445 X X X X X X X X X X X X X X X X
SIMOTION Control Unit D445-1 X X X X X X X X X X X X X X X X
Description
SIMOTION D425-x
SIMOTION Control Unit D425 X X X X X X
SIMOTION D435-x
SIMOTION Control Unit D435 (6AU1435-0AA00-0AA1) X X X X X X
SIMOTION D445-x
SIMOTION Control Unit D445-1 X X X X X X
Description
SIMOTION D410-x
SIMOTION Control Unit D410-2 DP X X X X X X X X X X X X X X X X
SIMOTION Control Unit D410-2 DP/PN X X X X X X X X X X X X X X X
Description
SIMOTION D425-x
SIMOTION Control Unit D425-2 DP X X X X X X X X X X X X X X X
SIMOTION Control Unit D425-2 DP/PN X X X X X X X X X X X X X X X
SIMOTION D435-x
SIMOTION Control Unit D435-2 DP X X X X X X X X X X X X X X X
SIMOTION Control Unit D435-2 DP/PN X X X X X X X X X X X X X X X
SIMOTION D445-x
SIMOTION Control Unit D445-2 DP/PN X X X X X X X X X X X X X X X X X X X
SIMOTION D455-x
SIMOTION Control Unit D455-2 DP/PN X X X X X X X X X X X X X X X X X X X
Description
SIMOTION P320-3
SIMOTION Motion Controller P320-3 X X X X X X X X X X X
SIMOTION P320-4
SIMOTION Motion Controller P320-4 S X X X X X X X
SIMOTION Motion Controller P320-4 E X X X X X X X
SIMOTION P350-3
SIMOTION Motion Controller P350-3 ISOPROFIBUS without DVD X X X X X X X X X X X X X X X X X X
SIMOTION Motion Controller P350-3 ISOPROFIBUS with DVD X X X X X X X X X X X X X X X X X X
SIMOTION Motion Controller P350-3 MCI-PN without DVD X X X X X X X X X X X X X X X X X X
SIMOTION Motion Controller P350-3 MCI-PN with DVD X X X X X X X X X X X X X X X X X X
SCOUT
SCOUT V5.1 HF6 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
A project is always created for exactly one kernel version and one device type and will only run on the relevant SIMOTION device if this exact kernel version and device type are
available. If this is not the case, the SIMOTION device remains in the STOP mode.
A scout V5.1 project is stored in the format V4.5. No conversion of V4.5 projects is carried out.
Description
SCOUT
SCOUT V5.1 HF6 X X X X X X X X X
3 CHAPTER
In this chapter, you will find information about the interaction of additional engineering packages to SCOUT regarding the kernel.
SCOUT
SCOUT V5.1 HF6 X
Description
SCOUT
SCOUT V5.1 HF6 X X
SCOUT
SCOUT V5.1 HF6 X X X
SCOUT
SCOUT V5.1 HF6 X X X
SCOUT Stand-alone
SCOUT Stand-alone V5.1 HF6 X X X
SCOUT
SCOUT V5.1 HF6 X
S7-CFC
CFC V7.0 HF1 X X X X
CFC V7.0 SP1 HF3 X X X X X
CFC V7.0 SP1 HF5 X X X X
CFC V7.1 SP2 HF2 X X
CFC V8.0 X
CFC V8.0 Upd1 X
CFC V8.0 SP4 Upd2 X X
CFC V8.0 SP4 Upd9 X
CFC V8.2 X X
Description
SCOUT
SCOUT V5.1 HF6 X
SCOUT
SCOUT V5.1 HF6 X X X
WinCC flexible RT
WinCC flexible RT 2007 SP1 X X X X X X X X X X
WinCC flexible RT 2008 X X X X X X X X X X
WinCC flexible RT 2008 SP1 X X X X X X X
WinCC flexible RT 2008 SP1 HF5 X X X X X X
WinCC flexible RT 2008 SP2 X X X
WinCC flexible RT 2008 SP2 Upd13 X X X
WinCC flexible RT 2008 SP3 X X X X X X X X
WinCC flexible RT 2008 SP3 Upd2 X X X X X X X X
WinCC flexible RT 2008 SP3 Upd4 X X X X X
WinCC flexible RT 2008 SP3 Upd5 X X X X X
WinCC flexible RT 2008 SP3 Upd7 X X X X X X X X
WinCC flexible RT 2008 SP5 X X
4 CHAPTER
In this chapter, you will find information about the interaction of additional technology packages to the kernel and to the WebTraceViewer.
Description
SIMOTION TP CAM
SIMOTION Technology package CAM V4.1 SP1 X X X X X X X X X X
SIMOTION Technology package CAM V4.1 SP2 X X X X X X X X X X
SIMOTION Technology package CAM V4.1 SP4 X X X X X X X X X X
SIMOTION Technology package CAM V4.1 SP5 X X X X X X X X X X
SIMOTION Technology package CAM V4.2 SP1 X X X
SIMOTION Technology package CAM V4.3 SP1 X X X X X X X X
SIMOTION Technology package CAM V4.4 X X X X X
SIMOTION Technology package CAM V4.5 X X X
SIMOTION Technology package CAM V5.1 X X
SIMOTION TP CAM EXT
SIMOTION Technology package CAM_EXT V4.1 SP1 X X X X X X X X X X
SIMOTION Technology package CAM_EXT V4.1 SP2 X X X X X X X X X X
SIMOTION Technology package CAM_EXT V4.1 SP4 X X X X X X X X X X
SIMOTION Technology package CAM_EXT V4.1 SP5 X X X X X X X X X X
SIMOTION Technology package CAM_EXT V4.2 SP1 X X X
SIMOTION Technology package CAM_EXT V4.3 SP1 X X X X X X X X
SIMOTION Technology package CAM_EXT V4.4 X X X X X
Description
Description
SIMOTION OACAMGEN
SIMOTION Technology package OACAMGEN V1.1 X X X X X X X X X
SIMOTION Technology package OACAMGEN V2.0 X X X X X X
SIMOTION Technology package OACAMGEN V3.0 HF1 X X X X X
SIMOTION Technology package OACAMGEN V4.0 HF1 X
SIMOTION Technology package OACAMGEN V4.0 HF3 X X X X X X X
SIMOTION OADPM
SIMOTION Technology package OADPM V1.1 X X
SIMOTION Technology package OADPM V1.1 HF1 X
SIMOTION Technology package OADPM V1.1 HF2 X X X
SIMOTION Technology package OADPM V1.2 X X X
SIMOTION Technology package OADPM V1.2 HF1 X X X X X X
SIMOTION Technology package OADPM V1.2 HF2 X X X X X X
SIMOTION OAMIIF
SIMOTION Technology Package OAMIIF V1.0 HF1 X X
SIMOTION Technology Package OAMIIF V1.0 HF2 X X X
SIMOTION Technology Package OAMIIF V1.0 HF4 X X X
SIMOTION Technology Package OAMIIF V1.0 HF5 X X X X X X X
SIMOTION OAVIBX
SIMOTION Technology Package OAVIBX V1.0 HF1 X X X
SIMOTION Technology Package OAVIBX V1.0 HF2 X X X
SIMOTION Technology Package OAVIBX V1.0 HF3 X X X X X X
SIMOTION Technology Package OAVIBX V1.0 HF4 X
SIMOTION OACAMGEN
SIMOTION Technology package OACAMGEN V1.1 X X X X X X X X X X X X X X X X X X X
SIMOTION Technology package OACAMGEN V2.0 X X X X X
SIMOTION Technology package OACAMGEN V3.0 HF1 X X X X X
SIMOTION Technology package OACAMGEN V4.0 HF1 X X X X X
SIMOTION Technology package OACAMGEN V4.0 HF3 X X X X X X X
SIMOTION OADPM
SIMOTION Technology package OADPM V1.1 X X X X X X X
SIMOTION Technology package OADPM V1.1 HF1 X X X X X X X
SIMOTION Technology package OADPM V1.1 HF2 X X X X X X X X X X
SIMOTION Technology package OADPM V1.2 X X X X X X X X X X X X X
SIMOTION Technology package OADPM V1.2 HF1 X X X X X X X X X
SIMOTION Technology package OADPM V1.2 HF2 X X X X X X X X X X X
SIMOTION OAMIIF
SIMOTION Technology Package OAMIIF V1.0 HF1 X X X X X X X
SIMOTION Technology Package OAMIIF V1.0 HF2 X X X X X X X X X X
SIMOTION Technology Package OAMIIF V1.0 HF4 X X X X X X X X X X X X X
SIMOTION Technology Package OAMIIF V1.0 HF5 X X X X X X X X X X X X X X
SIMOTION OAVIBX
SIMOTION Technology Package OAVIBX V1.0 HF1 X X X X X X X X X X
SIMOTION Technology Package OAVIBX V1.0 HF2 X X X X X X X X X X X X X
SIMOTION Technology Package OAVIBX V1.0 HF3 X X X X X X X X X X X
Description
SIMOTION OAVIBX
SIMOTION Technology Package OAVIBX V1.0 HF4 X X X
WebTraceViewer
WebTraceViewer V1.0 X X X X X X X X X
WebTraceViewer V1.1 X X X X X X X X X
WebTraceViewer V2.0 X X X X X X X X X X X X X X X X X X X X X X X X X
WebTraceViewer V2.0 HF1 X X X X X X X X X X X X X X X X X X X X X X X X X
WebTraceViewer V2.2 X X X X X X X X X X X X X X X X X X X X X X X X X
WebTraceViewer V2.2 SP1 X X X X X X X X X X X X X X X X X X X X X X X X X
WebTraceViewer V2.3 X X X X X X X X X X X X X X X X X X X X X X X X X
WebTraceViewer V2.4 X X X X X
WebTraceViewer
WebTraceViewer V1.0 X X X X X X X
WebTraceViewer V1.1 X X X X X X X
WebTraceViewer V2.0 X X X X
WebTraceViewer V2.0 HF1 X X X X X X X
WebTraceViewer V2.2 X X X X X X X
WebTraceViewer V2.2 SP1 X X X X X X X
WebTraceViewer V2.3 X X X X X X X
WebTraceViewer V2.4 X X X X X X X X
5 CHAPTER
This chapter contains information on the interaction between supplementary boards and memory cards.
Description
Description
Description
Description
Description
SIMOTION P boards
ISOPROFIBUS Board for P350-3 and P320-4 X X X X X X X X X X X X X X X X X X X X X X X X X
MCI-PN Board X X X X X X X X X X X X X X X X X X
Description
MMC Bootloader
MMC Bootloader V1.0.0.2 X
MMC Bootloader V1.1.0.0 X X
MMC Bootloader V1.2.0.0 X X
MMC Bootloader V2.12.0.0 X
MMC Bootloader V2.13.0.0 X
MMC Bootloader V3.1.0.0 X
MMC Bootloader V3.2.0.0 X X
MMC Bootloader V4.0.0.0 X X
MMC Bootloader V4.1.0.0 X X X
CF Bootloader
CF Bootloader V1.00 X X
CF Bootloader V1.02 X X
CF Bootloader V2.02 X X
CF Bootloader V2.03 X X X X X X
CF Bootloader V2.07 X X X X X X X X X X
CF Bootloader V2.08 X X X X
CF Bootloader V2.09 X X X X
CF Bootloader V2.10 X X X X
CF Bootloader V3.02 X X X X X X
CF Bootloader V3.04 X X X X X X X
Description
Description
Description
Supplementary information
Engineering software
User memory
Memory size available for the MMC: MMC: MMC: MMC: MMC:
user on the storage medium 16 MB, 32 32 MB 64 MB 64 MB 64 MB
(MMC) MB
Memory size V4.1 SP1 --- 32: 26 MB 64: 56 MB --- ---
available for the V4.1 SP2 --- 32: 26 MB 64: 53 MB 64: 53 MB 64: 53 MB
user on the storage
medium (MMC) V4.1 SP4 --- 32: 26 MB 64: 52 MB 64: 52 MB 64: 52 MB
V4.1 SP5 --- 32: 26 MB 64: 52 MB *) 64: 52 MB *) 64: 52 MB *)
V4.2 SP1 --- --- 64: 52 MB *) 64: 52 MB *) 64: 52 MB *)
V4.3 SP1 --- --- 64: 52 MB *) 64: 52 MB *) 64: 52 MB *)
V4.4 --- --- 64: 48 MB *) 64: 48 MB *). 64: 48 MB *)
V4.5 --- --- 64: 48 MB *) 64: 48 MB *) 64: 48 MB *)
V5.1 --- --- 64:48 MB *) 64:48 MB *) 64:48 MB *)
*) without Webtrace Viewer
V4.4 300 MB
V4.5 300 MB
V5.1 300 MB
V4.4 20 MB
V4.5 20 MB
V5.1 20 MB
V4.1 SP2 17 MB 23 MB 23 MB 47 MB 47 MB
V4.1 SP4 17 MB 23 MB 23 MB 47 MB 47 MB
V4.1 SP5 17 MB 23 MB 23 MB 47 MB 47 MB
V4.2 SP1 17 MB 23 MB 23 MB 47 MB 47 MB
V4.3 SP1 23 MB 29 MB 29 MB 2) 59 MB
>V4.3 SP1 3) 3) 3) 3) 3)
User RAM
V4.1 SP1 25 MB 25 MB 25 MB 50 MB ---
V4.1 SP2 26 MB 35 MB 35 MB 70 MB 70 MB
V4.1 SP4 26 MB 35 MB 35 MB 70 MB 70 MB
V4.1 SP5 26 MB 35 MB 35 MB 70 MB 70 MB
V4.2 SP1 38 MB 48 MB 48 MB 96 MB 96 MB
V4.3 SP1 38 MB 48 MB 48 MB 2) 96 MB
>V4.3 SP1 3) 3) 3) 3) 3)
>V4.3 SP1 3)
Additional working
memory for Java V4.1 SP1 HF6 --- 20 MB ---
applications 1)
V4.1 SP2 20 MB
V4.1 SP4 20 MB
V4.1 SP5 20 MB
V4.2 SP1 20 MB
V4.3 SP1 20 MB
>V4.3 SP1 3)
1) The D410 only has a Java Virtual Machine as of V4.1 SP2
2) For D445, only kernels ≤ V4.2 are available.
3) For D410, D425, D435 and D445-1, only kernels ≤ V4.3 are available..
SIMOTION D CF cards are delivered with a boot loader and SIMOTION kernel. If the SIMOTION
kernel is updated, the boot loader may also have to be updated.
We always recommend that the latest boot loader available for the respective CF card is used.
The boot loaders are located in the standard installation path .....\Step7\U7umc\images
The following actual boot loaders are available:
· for 32 MB CF cards: D4x5_boot32.bin, Version V2.07
· for 64 MB CF cards: D4x5_boot64.bin, Version V2.07
· for 512 MB CF cards: D4xx_boot512.bin, Version V3.04
· for 1 GB CF cards (D4xx and D4x5-2): D4xx_D4x5_2_boot1024.bin, Version V3.04
· for 1 GB CF cards (D410-2): D410_2_boot1024.bin; Version 1.02
A new boot loader can be written to the CF card using SCOUT via "Options > Write boot sector".
Up to kernel version V4.1 SP1, only 512 MB can be used for a 1 GB CF ; the limitation applies not
only to the use by SIMOTION, but also for other uses such as the storage of documents.
For additional information about handling CF cards, see SIMOTION D Commissioning and
Installation Manuals, Chapter, SIMOTION CompactFlash card.
SIMOTION V4.1 SP2 SP4 SP5 / V4.2 SP1/V4.3 SP1 / V4.4 / V4.5 / V5.1
TS Adapter V5.1 (6ES7972-0CA33-0XA0) with SIMATIC Teleservice V6.1 SP5
TS Adapter II ISDN (6ES7972-0CC35-0XA0) with SIMATIC Teleservice V6.1 SP5
SIMATIC Panels and Panel-PCs to SIMOTION SCOUT TIA V5.1 HF6 in conjunction
with WinCC Advanced
The components listed below can together with SIMOTION controls V4.3 and up be projected and
operated with a scout TIA V5.1 HF6.