Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PARK TCR-03

PARK TCR-03 is a stand-alone 19-inch rack mountable dualdisplay IRIG-8 Time code Reader. It provides two
separate readouts in a single 1U unit enclosure. Each input channel of the TCR-03 has been designed to display
IRIG-8 count down time & ATD time. The unit can take MOD, EIA and ASCII codes. The input code is
automatically detected. The unit provides Ethernet interface as an option to read ASCII time code sent on
Ethernet.

The time code is displayed on an easy to read .56” high LED seven-segment display. High efficiency seven
segment displays are used to provide excellent visibility even in bright light. LED matrix is used to display the
Hold Status Hold, Up, or Down.

The PARK TCR-03 contains Automatic Gain Control Circuit to allow the unit to reliably work with a wide range of
signallevels. Adisplay indicationis provided to show the loss of inputsignal or corrupted time code.

Salient Features:

Timecode format:
• Standard IRIG-8 time code format forATD applications.
• Customized time formats for count down applications supporting HOLD and Up/Down bits in control fields
• Supports IRIG-B Modulated and DC codes

Propagation Delay Correction:


The card automatically adds 1 second in ATD mode and when counting up in CDT mode. It subtracts one second
in COT mode when counting down from received time to compensate for the 1-second propagation delay of
IRIG-B frame.

HOLD bit handling:


In COT mode, if HOLD bit is set in the Time Code received, 1-second correction (decrementing the received
time) is inhibited when counting down. Hold bit is ignoredwhile counting up in allmodes.

Specifications:
No. of time inputs :2
Signal level : 250 mV to 15V peak to peak for modulated code
0 V- 0.5 V Logic Low and 2.4 V to 5.0 V Logic High for TTL level DC code
-10V to -5 V Logic High and +5Vto +10V Logic Low for EIADC code.
Input Impedance : >10K
Input connectors : BNC
Modulation depth : 2:1 to 6:1 for modulated code
Indicators : COT /ATD, HOLD, UP/DOWN, 1Hz (blinking)
Front Switches : COT / ATD selection, Power ON/OFF
Time Display:
No. of displays :2
Display Type : 9-digit High Bright Red ?-segment LED display, showing
Days (3 digits), Hours (2 digits), Minutes (2 digits), Seconds (2 digits).
Display Size : 0.56”
Hold Status : LED Matrix showing H (hold),+ (up), or (down)

Input Connectors:
Modulated code : BNC
EIAcode : BNC
ASCII code : BNC
TTL input : BNC
Ethernet code : RJ45 (Optional)
BCD output : 50 pin D-type
HIW programming : 25 pin D-type

Dimensions:
Height : 1U
Width : 19” rack mountable
Depth : 16” inches

Operating Conditions:
Power : 110 V to 230 V AC, 25 Watts Maximum
Frequency : 50 to 70Hz
Temperature : 00c to +60c Operating
Humidity : 0 to 95% non-condensing

Contact Park Controls for the latest details on the pricing and data sheets.
Specifications are subject to change without notice.
KISHAN ARCADE, #464, 465 & 466,
New Thippasandra Main Road
HAL 3rd Stage, Bengaluru – 560 075
Tel: +91-80-2529 7199 / 2513 / 3482
AS9100C certified Fax: +91-80-2528 1716 / 4091 0252
ISO 9001:2008 certified info@parkcontrols.com / www.parkcontrols.com

You might also like