YANACOCHA SULFIDES LA QUINUA WEST (LQW) ENGINEERING SERVICES 26280-120-MTD-MTSS-02003

EQUIPMENT DATA SHEET


26280-220-MRA-MTSS-00001
LA QUINUA WEST POTABLE WATER TANK
La Quinua West Potable Water
Item Rev Title Notes UOM Supplier Data Additional Notes
Tank
SECTION A - GENERAL
A1 Seller Name 1 text - STA
A2 Quotation Reference Number text - STA
A3 Validity of Quotation text - STA
A4 Equipment Number text 1910-TK-007 -
A5 Area Description text Potable Water Storage -
A6 Quantity - 1 -
A7 Delivery Schedule text - STA
SECTION B - DUTY FLUID
B1 Duty Fluid text Potable Water -
Low TDS, TSS water suitable for
B2 Composition text -
sanitary purposes Design Flow Inflow= 50
B3 pH - 7.0 -
B4 Flow Rate - Nominal 3
m /h TBC
m3/hr - Typical Filling / draining
B5 Flow Rate - Design Filling Rate (O/F Sizing) 3
m /h 114 (HOLD) Temperature
- range = 4Maximum truck fill rate
B6 Flow Rate - Design Emptying Rate 3
m /h 100 @ 15 °C- Based on open drain
B7 Retention Time 2 h TBC -
3
B8 Design Specific Gravity g/cm 1.00 -
B9 Design Temperature °C 22 -
B10 Minimum Design Metal Temperature °C -10 -
B11 Internal Design Pressure 3 kPa(g) 0 -
B12 External Design Pressure 3 kPa(g) 0.25 -
SECTION C - TANK CHARACTERISTICS
C1 Construction (Welded/Bolted) text Welded -
C2 Orientation text Vertical -
C3 Inside Diameter, A mm 2500 -
C4 Sidewall Shell Height, B mm 4000 -
C5 Sidewall Shell Thickness, TS mm - STA
C6 Design Liquid Level, DLL 4 mm 3497 -
C7 Normal Operating Level, NOL mm 3180 -
C8 Minimum Liquid Level, ML mm 420 -
C9 Tank Lining Included Yes/No No -
C10 Tank Lining Thickness mm N/A -
3
C11 Live Volume (at NOL) m 14.0 -
C12 Operating Volume (at NOL) m
3
16.0 Ckech if roof
- is self supported
C13 Roof Type (Open / Flat / Conical) 5 text Flat (Removable) cone and -not removable
C14 Roof Angle, C degree 0 -
C15 Roof Thickness, TR 5 mm - STA
C16 Roof Stiffener Quantity 5 text - STA
C17 Roof Stiffener Size 5 text - STA
C18 Wind Girder 6 text Detail a - 65 x 65 x 6 STA
C19 Agitator Bridge Included Yes/No No -
C20 Staircase Type text Cage Ladder -
C21 Bridge Support Width, SP mm N/A -
C22 Bridge Beam Size mm N/A -
C23 Sliver Platform 9 Yes/No Full Platform -
C24 Platform/Roof Loads kPa (live load) 1.0 -
Refer to 26280-220-3DR-S01-
C25 Snow Load -
kgf/m2 00001 – Structural Design Criteria
C26 Shell Stiffener Size mm - STA
C27 Number of Shell Stiffeners - - STA
C28 Floor Configuration Slope from center of tank -
text
C29 Bottom Slope Angle % 2 -
C30 Floor Thickness, TF mm - STA
C31 Wear Plate Diameter, WD mm N/A -
C32 Wear Plate Thickness, WT mm N/A -
C33 Annular Plate Required Yes/No No -
C34 Annular Plate Width, D mm N/A -
Support Type (Plinth . Concrete Ring Wall / Concrete Fill / Engineered
C35 Concrete Fill -
Fill) text
C36 Anchors Required 7 Yes/No Yes -
C37 Manway - Side mm 750 -
C38 Manway - Top mm N/A -
C39 Clean Out mm x mm N/A -
C40 Sparger Yes/No No -
C41 Upcomer / Downcomer Yes/No No -
Refer to 26280-220-3DR-M10-
C42 Lifting Lugs 00001 – Mechanical Design -
Criteria for lifting lug requirements.
Yes/No
C43 Grounding Bosses Yes/No Yes -
C44 Membrane Lining Thickness mm N/A -
C45 Design Life years >20 -
C46 Erosion/Corrosion Allowance mm 0 -
SECTION D - WIND AND SEISMIC CONDITIONS
D1 Seismic Site Class 8 text D -
D2 Seismic Use Group (SUG) 8 text I -
D3 IBC 2018 - Basic Wind Speed 8 km/h 150 -
SECTION E - AGITATOR
E1 Agitated Tank Yes/No No -
E2 Agitator Tag Number text N/A -
E3 Agitator Static Weight kg N/A -
E4 Agitator Bending Moment Nm N/A -
E5 Agitator Torque Load Nm N/A -

26280-120-MTD-MTSS-02003_.xls Page 1 of 4
YANACOCHA SULFIDES LA QUINUA WEST (LQW) ENGINEERING SERVICES 26280-120-MTD-MTSS-02003
EQUIPMENT DATA SHEET
26280-220-MRA-MTSS-00001
LA QUINUA WEST POTABLE WATER TANK
La Quinua West Potable Water
Item Rev Title Notes UOM Supplier Data Additional Notes
Tank
SECTION F - BAFFLES
F1 Quantity No. N/A -
F2 Width, L mm N/A -
F3 Length, J mm N/A -
F4 Thickness, N mm N/A -
F5 Distance off Floor, L mm N/A -
F6 Distance off Wall, M mm N/A -
F7 Number of Supports (per baffle) mm N/A -
SECTION G - NOZZLES
G1 N1 text Inlet -
G2 Size NPS 3 (HOLD) -
G3 Placement (Roof / Shell / Bottom) text Roof -
G4 Pitch Circle Diameter, E mm 1875 (HOLD) -
G5 Distance from Centre Line, R mm N/A -
G6 Projection, S mm 300 (HOLD) -
G7 Off Bottom Distance, T mm N/A -
G8 Angular Orientation, V ° 0 (HOLD) -
G9 Flange Type text - STA
G10 Pipe Schedule text - STA
G11 ASME Flange Pressure Rating # 150 -
G12 N2 NPS Outlet -
G13 Size text 3 (HOLD) -
G14 Placement (Roof / Shell / Bottom) text Shell -
G15 Pitch Circle Diameter, E mm N/A -
G16 Distance from Centre Line, R mm 500 (HOLD) -
G17 Projection, S mm 300 (HOLD) -
G18 Off Bottom Distance, T mm 240 (HOLD) -
G19 Angular Orientation, V ° 90 (HOLD) -
G20 Flange Type text - STA
G21 Pipe Schedule text - STA
G22 ASME Flange Pressure Rating # 150 -
G23 N3 NPS Outlet -
G24 Size text 3 (HOLD) -
G25 Placement (Roof / Shell / Bottom) text Shell -
G26 Pitch Circle Diameter, E mm N/A -
G27 Distance from Centre Line, R mm -500 (HOLD) -
G28 Projection, S mm 300 (HOLD) -
G29 Off Bottom Distance, T mm 240 (HOLD) -
G30 Angular Orientation, V ° 90 (HOLD) -
G31 Flange Type text - STA
G32 Pipe Schedule text - STA
G33 ASME Flange Pressure Rating # 150 -
See Detail on 26280-420-MT-
G34 N4 text Overflow
Check -P&ID, 1000-00001s02
G35 Size NPS 8 (HOLD)
G36 Placement (Roof / Shell / Bottom) text Shell
O/F 4"--
G37 Pitch Circle Diameter, E mm N/A -
G38 Distance from Centre Line, R mm 0 (HOLD) -
G39 Projection, S mm 300 (HOLD) -
G40 Off Bottom Distance, T mm 3650 (HOLD) -
G41 Angular Orientation, V ° 0 (HOLD) -
G42 Flange Type text - STA
G43 Pipe Schedule text - STA
G44 ASME Flange Pressure Rating # 150 -
Accessway See Detail on 26280-420-MT-
G45 N5 text Manway
For tank
-
1000-00001s02
G46 Size NPS 30 (HOLD) -
G47 Placement (Roof / Shell / Bottom) text Shell diameter
- < 3m
G48 Pitch Circle Diameter, E mm N/A -
G49 Distance from Centre Line, R mm 0 (HOLD) use 24"
-
G50 Projection, S mm 200 (HOLD) -
G51 Off Bottom Distance, T mm 800 (HOLD) accessway
-
G52 Angular Orientation, V ° 270 (HOLD) -
Shell manway flange designed for
G53 Flange Type text hydrostatic loads as required by STA
API 650
G54 Pipe Schedule text - STA
Shell manway flange designed for
G55 ASME Flange Pressure Rating # hydrostatic loads as required by STA
API 650
G56 N6 text Vent -
G57 Size NPS 2 (HOLD) Check, 2" looks
- small
G58 Placement (Roof / Shell / Bottom) text Roof -
G59 Pitch Circle Diameter, E mm 1875 (HOLD)
for vent -
G60 Distance from Centre Line, R mm N/A -
G61 Projection, S mm 300 (HOLD) -
G62 Off Bottom Distance, T mm N/A -
G63 Angular Orientation, V ° 270 (HOLD) -
G64 Flange Type text - STA
G65 Pipe Schedule text - STA
G66 ASME Flange Pressure Rating # 150 -

26280-120-MTD-MTSS-02003_.xls Page 2 of 4
YANACOCHA SULFIDES LA QUINUA WEST (LQW) ENGINEERING SERVICES 26280-120-MTD-MTSS-02003
EQUIPMENT DATA SHEET
26280-220-MRA-MTSS-00001
LA QUINUA WEST POTABLE WATER TANK
La Quinua West Potable Water
Item Rev Title Notes UOM Supplier Data Additional Notes
Tank
G67 N7 text Drain -
G68 Size NPS 3 (HOLD) -
G69 Placement (Roof / Shell / Bottom) text Bottom -
G70 Pitch Circle Diameter, E mm N/A -
G71 Distance from Centre Line, R mm 0 (HOLD) -
See Detail on 26280-420-MT-
G72 Projection, S mm 200 (HOLD) -
1000-00001s01
G73 Off Bottom Distance, T mm 0 (HOLD) -
G74 Angular Orientation, V ° 20 (HOLD) -
G75 Flange Type text - STA
G76 Pipe Schedule text - STA
G77 ASME Flange Pressure Rating # 150 -
G78 N8 text Level Gauge -
G79 Size NPS 6 (HOLD) -
G80 Placement (Roof / Shell / Bottom) text Roof -
G81 Pitch Circle Diameter, E mm N/A -
G82 Distance from Centre Line, R mm 0 (HOLD) -
G83 Projection, S mm 200 (HOLD) -
G84 Off Bottom Distance, T mm 0 (HOLD) -
G85 Angular Orientation, V ° 20 (HOLD) -
G86 Flange Type text - STA
G87 Pipe Schedule text - STA
G88 ASME Flange Pressure Rating # 150 -
SECTION H - INSULATION AND CLADDING
H1 Insulation (by Others) Yes/No No -
H2 Cladding Type text N/A -
H3 Insulation Type text N/A -
H4 Insulation Thickness mm N/A -
H5 Insulation Support text N/A -
SECTION I - MATERIALS OF CONSTRUCTION
I1 Shell text A-240 Gr. 304L -
I2 Floor text A-240 Gr. 304L -
I3 Roof text A-240 Gr. 304L -
A-213 Gr. TP 304L; A-312 Gr. TP
I4 Nozzle Neck text -
304L
I5 Nozzle Flange(s) text A-182 Gr. F 304L -
I6 Nozzle Re-Pads text A-240 Gr. 304L -
I7 Baffles text N/A -
I8 Baffle Lining text N/A -
I9 Tank Lining text N/A -
I10 Bolts: internal text N/A -
I11 Nuts: internal text N/A -
I12 Washers: internal text N/A -
I13 Bolts: external text A-193 Gr. B8M CL2 -
I14 Nuts: external text A-194 Gr. 8M -
I15 Washers: external text A-240 Gr. 304L -
I16 Anchor Bolts text - STA
I17 Poison Pads text A-240 Gr. 304L -
I18 Gaskets text Garlock 3500 -
I19 Structures: external text A-36 -
I20 Other Wetted Parts text A-240 Gr. 304L -
I21 Other Internal Non-wetted Parts text A-240 Gr. 304L -
I22 Other External Non-wetted Parts text A-240 Gr. 304L -
SECTION J - SURFACE PROTECTION
Pickle and Passivate Welds and
J1 Cleanliness Internal text -
HAZ
J2 Cleanliness External text N/A -

J3 Painting Internal text N/A -

J4 Painting External text N/A -

SECTION K - WEIGHTS, LOADS AND INSTALLATION DETAILS


K1 Fabrication Weight kg - STA
K2 Full Fluid Weight @ SG (Fluid Only) kg 19700 STA
K3 Maximum Lift for Installation kg - STA
SECTION L - TESTING
L1 Hydrostatic text Required. As per API 650 -
L2 Vacuum Test for the bottom floor % Required. As per API 650 -
L3 Radiography % 10 -
L4 Ultrasonic % As per API 650 -
L5 Magnetic Particle % As per API 650 -
L6 Liquid Penetrant % Required on All Welds -
L7 Ferroxyl Testing text N/A -
L8 Stress Relieving text As per API 650 -

26280-120-MTD-MTSS-02003_.xls Page 3 of 4
YANACOCHA SULFIDES LA QUINUA WEST (LQW) ENGINEERING SERVICES 26280-120-MTD-MTSS-02003
EQUIPMENT DATA SHEET
26280-220-MRA-MTSS-00001
LA QUINUA WEST POTABLE WATER TANK
La Quinua West Potable Water
Item Rev Title Notes UOM Supplier Data Additional Notes
Tank
NOTES
1 STA - Seller To Advise.
2 Design retention time represents retention time of live volume, excluding volume below the minimum liquid level specified by NPSH-R, submergence, or agitation requirements.
3 Design external and internal pressures based on 0.25 kPa allowable pressure drop across goose neck vent.
4 Design liquid considered to be top of tank in each case for API 650 calculations.
5 Seller to advise on flat roof stiffening beam size and quantity.
6 Details listed are as per API 650 Figure 5.4
7 Seller shall check overturning moments for seismic and wind loads and shall advise on anchor chair design and quantity.
For further information regarding site conditions, refer to 26280-2200-3GS-M000-00003, General Specification for Climatic and Seismic Conditions, and 26280-220-3GS-M000-00004, General
8
Specification for Jobsite Access.
9 The platform shall include grating and handrails.
This document was prepared for the exclusive use of MINERA YANACOCHA SRL (“Owner”) in respect of the Yanacocha Sulfides Project and is issued pursuant to a Sub‐contract entered
into between Bechtel Chile Limitada (“Company”) or Bechtel Peru SRL ("Company") and Hatch Ltd. (“Contractor”). Except to the extent otherwise stated in said Sub‐contract,
Contractor does not accept and disclaims any and all liability or responsibility arising from any use of or reliance on this document by any third party or any modification or
misuse of this document by Owner or Company.
Revision Issue Status Prepared By / Date Checked By / Date Approved By / Date Client Approval / Date
00A Internal Review E. Cheng / 2021-04-13 G. Dickinson / 2021-04-13 L. Zunti / 2021-04-13
00B Client Review E. Cheng / 2021-04-26 G. Dickinson / 2021-04-26 L. Zunti / 2021-04-26
00C Issued for Quote E. Cheng / 2021-06-25 G. Dickinson / 2021-06-25 L. Zunti / 2021-06-25

26280-120-MTD-MTSS-02003_.xls Page 4 of 4