Professional Documents
Culture Documents
1
1
Which one of the following directly affects all persons working with electricity in a working environment?
o BS 7671
Question 2:
Which one of the following are non-statutory regulations?
o BS 7671
Question 3:
Which one of the following is a direct implication of not complying with statutory regulations?
o Loss of earnings
o Lost clients
o Dismissal
o Prosecution
Question 4:
The document showing the location of electrical equipment in an electrical installation is a:
o specification
o drawing
o variation order
o Gantt chart
Question 5:
Which one of the following diagram types does not show individual conductors or cables but shows the sequence of
equipment?
o Block
o Circuit
o Schematic
o Bar chart
Question 6:
The symbol shown represents:
o one-way switch
o two-way switch
o intermediate switch
o pull switch
Question 7:
Which one of the following is the correct drawing scale where a wall, 4m in length, measures 8cm on a drawing?
o 1:50
o 1:100
o 1:200
o 1:500
Question 8:
A drawing is produced to a scale of 1:50 showing a socket outlet installed 3.5cm from the corner of a room. Which one
of the following is the actual distance from the corner in the room?
o 0.875m
o 1.75m
o 3.5m
o 7m
Question 9:
A circuit installed to supply a fire panel would be identified as:
o data communication
o control circuit
Question 10:
The type of trunking that can be used as a circuit protective conductor is:
o mini
o PVC dado
o steel
o plastic
Question 11:
The insulation material of mineral insulated metal sheathed cables is absorbent; therefore the terminations must be:
o watertight
o correctly identified
Question 12:
Additional cable supports should be provided in trunking where:
o segregation is required
Question 13:
Band I and Band II circuits can be enclosed in the same enclosure, provided that:
o they are twisted around each other along the trunking length
Question 14:
Which one of the following is the type of conduit fixing shown?
o Cleat
o Clip
o Crampet
o Saddle
Question 15:
Which one of the following symbols represents the rating factor for thermal insulation?
o Ci
o Ca
o Cf
o Cg
Question 16:
Which one of the following is the value of voltage drop, per ampere, per metre, for a 10mm2 multi-core flat
thermoplastic 70°C cable, intended to supply a single phase circuit?
o 44 mV/A/m
o 11 mV/A/m
o 4.4 mV/A/m
o 2.8 mV/A/m
Question 17:
Which one of the following is the maximum current carrying capacity for a single core 6mm2 70°C thermoplastic
insulated non armoured cable, enclosed in conduit on a wall installed for a single phase circuit?
o 31A
o 32A
o 36A
o 41A
Question 18:
Which one of the following is the value of voltage drop, in millivolts per ampere per metre, for a 4mm2 multi core
thermosetting non armoured cable, intended to supply a single phase circuit?
o 29 mV/A/m
o 18 mV/A/m
o 11 mV/A/m
o 7.3 mV/A/m
Question 19:
Which one of the following devices is suitable for an installation supplying an X-ray machine in a hospital?
o BS EN 60898 Type D
o BS EN 60898 Type C
o BS EN 60898 Type B
Question 20:
Which one of the following devices will disconnect in the fastest time if a short circuit current of approximately 400A
occurred on a circuit?
Question 21:
Which one of the following is the minimum conduit size suitable for a short straight run containing the following
stranded cables: • 4 x 1.5mm2 • 3 x 2.5mm2?
o 16mm
o 20mm
o 25mm
o 32mm
Question 22:
Which one of the following is the minimum conduit size suitable for a short straight run containing the following
stranded cables: • 8 x 1.5mm2 • 2 x 2.5mm2 • 2 x 4.0mm2?
o 16mm
o 20mm
o 25mm
o 32mm
Question 23
Which one of the following is the conduit capacity factor to be used where a 25mm conduit has 2 bend in a 6m run?
Answer
o 111
o 182
o 333
o 600
Question 24:
The electrical system in which the connection to earth is by an earth electrode is:
Answer
o TT
o TN-S
o TN-C
o TN-C-S
Question 25:
Which one of the following earthing arrangements is shown in the diagram?
o TN-C-S
o TT
o TN-C
o TN-S
Question 26:
Which one of the following is the correct name of the component which links the main earthing terminal of an
installation to the means of earthing?
Answer
o Earthing conductor
o Functional earth
Question 27:
What is represented by Zs in the following formula: Zs = Ze + (R1 + R2)?
Question 28:
Which one of the following defines the term ‘main protective bonding conductor’?
Question 29:
Which one of the following is the purpose of the main protective bonding conductor?
o To raise extraneous conductive parts to the same voltage as the supply under overload
o To raise extraneous conductive parts to the same voltage as the supply under earth fault conditions
o To raise extraneous conductive parts to the same voltage as the supply under normal conditions
o To raise extraneous conductive parts to the same voltage as the supply under transient fault conditions
Question 30:
Which one of the following is an exposed conductive part?
o Metal-clad switch
o Structural steelwork
Question 31:
Which one of the following is metal cable trunking?
o Insulated part
Question 32:
Which one of the following is an extraneous conductive part?
o PVC mini-trunking
Question 33:
Which one of the following methods of generating electricity uses fossil fuels?
o Wave power
o Solar
o Gas
o Wind
Question 34:
Which one of the following uses sunlight to generate electricity?
o Photo-voltaic
o Biomass
o Wind
Question 35:
Which one of the following is a transmission voltage?
o 400kV
o 33kV
o 11kV
o 400V
Question 36:
Which one of the following is a typical distribution voltage for a medium-sized factory where a private sub station is
located?
o 230V
o 400V
o 5kV
o 11kV
Question 37:
In which of the following parts of the electrical distribution network would a step-down transformer be located?
o Power station
o Pylon
o Inverter
Question 38:
Which one of the following describes the process of a solar photo voltaic system?
o Solar power causes hot air to rise, rotating a generator that produces electricity
Question 39:
Which one of the following is a suitable use for rainwater harvesting?
o Baths/showers
o Toilet flushing
o Drinking water
o Cooking water
Question 40:
Which one of the following micro-generation systems requires the least maintenance once installed?
o Biomass
o Solar thermal