Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Product

RMC Cable Specification .

50LM-114 copper FR-LSZH Eca black ( 120019 )

Material
Inner conductor Smooth copper tube
Insulation Physcally foamed Pe
1st Outer conductor Overlapping copper foil with slots
Jacket Non-halogenated, fire retardant PE

Dimensions
Inner conductor ( Ø mm ) 13,00
Insulation ( Ø mm ) 32,80
Jacket ( Ø mm ) 36,50

Mechanical properties
Minimum bending radius ( mm ) 500
Tensile force ( N ) 3000

Electrical properties
Nominal impedance ( Ω ) 50 ± 2
Nominal capacitance ( pF/m ) 76
Velocity of propagation ( % ) 88
Dc breakdown voltage ( kV ) 10
Insulation resistance ( MΩ▪km ) > 5000
VSWR 400-470 ( MHz ) ≤ 1,3
Standards
Temperatura recomendada de Almacenaje - 30 + 80
Temperatura recomendada de Instalación - 25 + 60
Temperatura recomendada de Operación - 30 + 80
CPR Eca
IEC 60332-1 Compliant
IEC 60754-1_2 Compliant
Attenuation
Frequency Attenuation Coupling loss ( 50% / 95% )
( MHz ) ( 20°C,dB/100m ) ( 20°C,dB )
350 2,14 62/66
400 2,35 57/59
450 2,51 59/65
700 3,46 65/76
800 3,80 66/77
900 4,13 64/73

Attenuation & coupling loss values are given with tolerances of 5% and ±10dB,respectively.
The electrical characteristics would be optimized according to the operating frequency band requested in the purchase order.

Labradores, 25-Nave 18·Pol.Ind. Prado del Espino· 28660 Boadilla del Monte (Madrid)· Tel.:+34 916653580·Web: www.mccspain.com 1/1