Huawei ALD Software Commissioning

Command Guide
Issue 08
Date 2021-12-06

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2021. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior
written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided “AS IS” without warranties,
guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People’s Republic of China

Website: https://www.huawei.com

Email: support@huawei.com

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. i


Huawei ALD Software Commissioning Command Guide About This Document

About This Document

Overview
You are advised to read the entire document before using the Huawei ALD. The
following table lists the contents of this document.

Chapter Description

1. Overview This chapter provides an overview of all available


commissioning commands of the remote control
unit (RCU) and remote expansion unit (REU).

2. Application of RET/RAE This chapter describes how to use RET/RAE


Commissioning commissioning commands.
Commands

3. Application of REU This chapter describes how to use REU


Commissioning commissioning commands.
Commands

4 Application of This chapter describes how to use TMA/COM


TMA/COM commissioning commands.
Commissioning
Commands

5 Overview of Vendor This chapter describes vendor specific commands of


Specific Commands each version.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. ii


Huawei ALD Software Commissioning Command Guide About This Document

Change History
Issue Date Description

01 2014-01-15 This issue is the first


commercial release.

02 2014-10-11 This is the second commercial


release.

03 2017-01-09 Updated RCU commissioning


commands and added AISU
commissioning commands.

04 2017-10-30 Updated RCU commissioning


commands

05 2018-09-26 Updated RCU commissioning


commands, Add TMA/COM
commissioning commands

06 2020-06-10 Added the AISU


commissioning command

07 2020-09-29 Added vendor specific


commands

08 2021-12-06 Added vendor specific


commands and new version

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. iii


Huawei ALD Software Commissioning Command Guide Contents

Contents

About This Document ................................................................................................................... ii


1 Overview ........................................................................................................................................ 1
1.1 Software Version Compatibility ............................................................................................................................. 1
1.2 Commissioning Commands .................................................................................................................................... 4

2 Application of RET/RAE Commissioning Commands ........................................................ 6


3 Application of REU Commissioning Commands ............................................................... 12
4 Application of TMA/COM Commissioning Commands .................................................. 14
5 Overview of Vendor Specific Commands ........................................................................... 16
5.1 AISG Command Format......................................................................................................................................... 16
5.2 Software Versions ................................................................................................................................................... 16
5.3 Introduction to Vendor Specific Commands ...................................................................................................... 22

A Appendix ..................................................................................................................................... 33

Issue 08 (2021-12-08) Copyright © Huawei Technologies Co., Ltd. iv


Huawei ALD Software Commissioning Command Guide 1 Overview

1 Overview

Commissioning commands are designed for antenna line devices (ALDs), including
the remote control unit (RCU), remote electrical tilt (RET), remote antenna
extension (RAE), RET expansion unit (REU), Tower Mounted Amplifier (TMA) and
Combiner(COM). Users can use the commissioning commands on the LMT or
MAEMAE to configure or query information related to the ALDs.

1.1 Software Version Compatibility

1.2 Commissioning Commands

1.1 Software Version Compatibility


Commissioning commands apply to the following devices:
 RETs and RAEs:
− ANT SAA V100R001C00 or later
− ANT SAA V100R001C01 or later
− ANT SAA V100R002C00 or later
− ANT SAA V100R002C01 or later
− ANT RCU V400R002C00 and its patch versions or later
− ANT RCU V400R002C01 or later
− ANT RCU V400R002C02 and its patch versions or later
− ANT RCU V400R003C00 or later
− ANT RCU V400R003C01 and its patch versions or later
− ANT RCU V500R002C00 and its patch versions or later
− ANT RCU V500R003C00 and its patch versions or later
 REUs: ANT REU V400R001C00/ANT REU V400R002C00
 TMAs and COMs:
− ANT TMA&COM V300R001C00

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 1


Huawei ALD Software Commissioning Command Guide 1 Overview

− ANT TMA&COM V300R001C01 and its patch versions or later

Table 1-1 Software version compatibility of commissioning commands

Commissioning Command AN ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT
T RCU RCU RCU REU REU SAA SAA SAA SAA TMA RCU
RCU V400 V40 V40 V40 V40 V10 V10 V10 V10 &CO V50
V40 R002 0R0 0R0 0R0 0R0 0R0 0R0 0R0 0R0 M 0R0
0R0 C01/ 02C 03C0 01C 02C 01C 01C 02C 02C V30 02/R
02C C02 03 0 00 00 00 01 00 01 0R0 003
00 01C C00
00/C
01

Command used for protocol Y Y N Y N N N N N N N N


switching

Command for working mode Y Y N Y N N N N Y Y N Y


switching

Command used to turn on the Y Y Y Y N N Y Y Y Y Y N


logging switch

Command used to configure Y Y Y Y Y Y Y Y Y Y Y Y


the commissioning mode

Command used to enter the N Y Y Y Y Y Y Y Y Y Y N


mini area

Command used to clear N Y Y Y N N Y Y Y Y Y N


backplane data

Command used to configure N N Y Y N Y N Y Y Y Y Y


the loading area

Command used to configure N N Y N Y N N N N N N N


the multi-port mode

Command used to configure N N Y Y N N N N Y Y N N


the transparent transmission
state

Command used to set the N N N N Y Y N N N N N N


visibility of REU SNs

Command for REU working N N Y N Y Y N N N N N N


mode switching

Command used to query the Y Y N Y N N N N Y Y N N


communications protocol
version

Command used to query the Y Y N N N N N N Y Y N N


working mode

Command used to query the Y Y Y Y Y Y Y Y Y Y Y Y


status of the commissioning
mode

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 2


Huawei ALD Software Commissioning Command Guide 1 Overview

Commissioning Command AN ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT
T RCU RCU RCU REU REU SAA SAA SAA SAA TMA RCU
RCU V400 V40 V40 V40 V40 V10 V10 V10 V10 &CO V50
V40 R002 0R0 0R0 0R0 0R0 0R0 0R0 0R0 0R0 M 0R0
0R0 C01/ 02C 03C0 01C 02C 01C 01C 02C 02C V30 02/R
02C C02 03 0 00 00 00 01 00 01 0R0 003
00 01C C00
00/C
01

Command used to query the Y Y Y Y N N N N Y Y N Y


configuration data name

Command used to query the N Y Y Y Y Y Y Y Y Y Y Y


software version B

Command used to query the N Y Y Y Y Y Y Y Y Y Y Y


port number and subunit
number

Command used to query the N Y N N N N N N N Y N N


BOOT version and program
running address/mechanical
tilt compensation

Command used to query the N N Y Y N N N N Y Y N N


transparent transmission state

Command used to query the N N N Y N N N N Y Y N Y


board temperature

Command used to query the N N N Y N N N N Y Y N Y


information of H version
configure file

Command used to query the N N N N Y Y N N N N N N


REU working mode

Command used to configure N N N N N N Y Y N Y N N


the azimuth algorithm state

Command used to binding N N N Y N N N N N N N Y


RET serial number

Command used to query RET N N N Y N N N N N N N Y


serial number binding status

Command used to query port N N N Y N N N N Y Y N Y


voltage

Command used to set RAE N N N N N N N N N N Y Y


serial number to be visible for
log

Command used to query the N N N N N N N N N Y N N


GPS information

Command used to query the N N N N N N N N N Y N N


azimuth compensation

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 3


Huawei ALD Software Commissioning Command Guide 1 Overview

Commissioning Command AN ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT
T RCU RCU RCU REU REU SAA SAA SAA SAA TMA RCU
RCU V400 V40 V40 V40 V40 V10 V10 V10 V10 &CO V50
V40 R002 0R0 0R0 0R0 0R0 0R0 0R0 0R0 0R0 M 0R0
0R0 C01/ 02C 03C0 01C 02C 01C 01C 02C 02C V30 02/R
02C C02 03 0 00 00 00 01 00 01 0R0 003
00 01C C00
00/C
01

Command used to configure N N N N N N N N N Y N N


the azimuth/mechanical tilt
compensation

1.2 Commissioning Commands


Configuration-related Commissioning Commands
 Command used for protocol switching
 Command for working mode switching
 Command used to turn on the logging switch
 Command used to configure the commissioning mode
 Command used to enter the mini area
 Command used to clear backplane data or extern flash data
 Command used to configure the loading area
 Command used to configure the multi-port mode
 Command used to configure the transparent transmission state
 Command used to set the visibility of REU SNs
 Command for REU working mode switching
 Command used to configure the azimuth algorithm state
 Command used to binding RET serial number
 Command used to set RAE serial number to be visible for log
 Command used to configure the azimuth/mechanical tilt compensation

Query-related Commissioning Commands


 Command used to query the communications protocol version
 Command used to query the working mode
 Command used to query the status of the commissioning mode
 Command used to query the configuration data name
 Command used to query the software version B

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 4


Huawei ALD Software Commissioning Command Guide 1 Overview

 Command used to query the port number and subunit number


 Command used to query the BOOT version and program running address
 Command used to query the board temperature
 Command used to query the transparent transmission state
 Command used to query the information of H version configure file
 Command used to query the REU working mode
 Command used to query port voltage
 Command used to query RET serial number binding status

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 5


2 Application of RET/RAE Commissioning
Huawei ALD Software Commissioning Command Guide Commands

2 Application of RET/RAE Commissioning


Commands

This chapter describes the functions and application methods of RET/RAE


commissioning commands.
 Command used for protocol switching
On the LMT or MAEMAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0001PV0000000X. The variable X
equals 0 or 1. AISG 2.0 is used when X equals 1 and AISG 1.1 is used when X
equals 0. After the command is executed, the device needs to be removed and
then added again to make the protocol switching take effect.
 Command for working mode switching
On the LMT or MAEMAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0002PV000000XX. The variable XX
equals 01, 10 or 11. The Single-RET mode is used when XX equals 01, and the
Multi-RET mode is used when XX equals 10 or 11*. After the command is
executed, the device needs to be removed and then added again to make the
working mode switching take effect.
*Comment: XX equals 10 only used for ANT RCU V400R003C00 platform and
ANT SAA V100R002C00 platform. The difference from 11 is that after switching
to Multi-RET mode with PI0002PV00000010, 2 bytes color coding information
will be added at the end of antenna mode for each subunit when querying. And
switching Multi-RET mode with PI0002PV00000011, no color coding
information will be added on the original antenna mode.
 Command used to turn on the logging switch
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0003PV0000000X. The variable X
equals 0, 1or2. Value 0 indicates the log function is disabled, value 1 indicates
the log function is enabled, and value 2 indicates AISU logs.The log contains
motor-related parameters, port voltages, and other information. It cannot be
viewed on the LMT or MAE, but can be parsed to facilitate troubleshooting.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 6


2 Application of RET/RAE Commissioning
Huawei ALD Software Commissioning Command Guide Commands

After troubleshooting is complete, it is recommended that the logging switch


be turned off. By default, the switch is turned off.
 Command used to configure the commissioning mode
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV0000000X. The variable X
equals 0 or 1. The normal mode is used when X equals 0, and the
commissioning mode is used when X equals 1. It is recommended that the
commissioning mode be disabled. By default, the normal mode is used.
 Command used to enter the mini area
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV00000001 to enter the
commissioning mode. Then, run the MOD RETDEVICEDATA command with
the Antenna Serial No. parameter set to PI0005PV00000001 to enter the mini
area. In the mini area, only application-layer information query and software
upgrade are supported. If software needs to be upgraded again in the mini area,
you can switch the device from the mini area to the normal running area. The
command used to enter the mini area is added in V400R002C01 or later.
 Command used to clear backplane data or extern flash data
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV00000001 to enter the
commissioning mode. Then, run the MOD RETDEVICEDATA command with
the Antenna Serial No. parameter set to PI0006PVXXXXXXXX. The variables
XXXXXXXX indicate the information of the backplane or the extern flash. The
command used to clear data is added in V400R002C01 or later.
 Command used to configure the azimuth/mechanical tilt compensation (AISU)
On the LMT or MAE, run the MOD RAEDEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV00000001 to enter the
equipment mode. Then, run the MOD RAEDEVICEDATA command with the
Antenna Serial No. parameter set to PI000FPV000XXXXX or
PI000FPV10XXXXXX.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 7


2 Application of RET/RAE Commissioning
Huawei ALD Software Commissioning Command Guide Commands

1. The first digit X indicates the compensation mode. If X is 1, an absolute value is written. If
X is 2, a relative compensation value is written (after the writing is successful, the total
compensation value is the remainder after the value is divided into 360). If X is F, the
compensation value is cleared. The storage area for the compensation value of the
commissioning command is independent of that for the compensation value of the
equipment. The total compensation value equals the sum of the compensation value of
the equipment and the compensation value of the commissioning command
2. PI000FPV10XXXXXX indicates the mechanical tilt. The first X indicates whether the data
is positive or negative. Value 1 indicates that the digit is positive, and value 2 indicates
that the digit is negative. The second X indicates the compensation mode. Value 1
indicates an absolute value. Value 2 indicates a relative value (the total compensation
value range is –180 to +180). Value F indicates that the compensation value is cleared.
The last four digits indicate the mechanical tilt compensation value in the unit of 0.1
degree. The value ranges from 0 to 900. After the value is written successfully, the total
compensation value is the remainder after the value is divided into 180. The storage area
for the compensation value of the commissioning command is independent of that for
the compensation value of the equipment. The total compensation value equals the sum
of the compensation value of the equipment and the compensation value of the
commissioning command.
 Command used to configure the loading area
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0007PV0000000X. The variable X
ranges from 0 to 3. The values 0, 1, 2, and 3 indicate the software upgrade area,
software mini area, weight factory area, and azimuth area, respectively. By
default, the software upgrade area is used.
 Command used to configure the azimuth algorithm state
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0008PV00000002 to enable the
azimuth algorithm.
 Command used to configure the multi-port mode
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI000APV0000000X. The variable X
equals 0 or 1. The link mutually exclusive mode is used when X equals 0, and
the co-site mode is used when X equals 1. By default, the link mutually
exclusive mode is used.
 Command used to configure the transparent transmission state
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI000BPV0000000X. The variable X
ranges from 0 to 2. The values 0, 1, and 2 indicate the normal mode,
transparent transmission mode, and AISU management mode. By default, the
normal mode is used.
 Command used to binding RET serial number
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to: PI000EPV00XXXXXX. The variable X is
the last six serial numbers which need to be bind,After that, the serial number
will control the two phase shifters corresponding to the two RETs; run the MOD

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 8


2 Application of RET/RAE Commissioning
Huawei ALD Software Commissioning Command Guide Commands

RETDEVICEDATA command with the Antenna Serial No. parameter set to:
PI000EPV00000000, the serial number will quit the binding status, the phase
shifter will be controlled by it own serial number.
 Command used to query the communications protocol version
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0001, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value QI0001QV00000001 indicates that AISG 2.0 is used, and
the value QI0001QV00000000 indicates that AISG 1.1 is used.
 Command used to query the working mode
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0002, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value QI0002QV00000001 indicates that the
multi-logical-device mode is used, the value QI0002QV00000011 indicates
that the subunit mode is used, and the value QI0002QV00000031 indicates
that the RAE is used.
 Command used to query the status of the commissioning mode
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0004, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial
No.parameter. The value QI0004QV00000000 indicates that the normal mode
is used, and the value QI0004QV00000001 indicates that the commissioning
mode is used.
 Command used to query the configuration data name
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0005, and then run the DSP ALDVER
command to query the configuration data name.
 Command used to query the software version B
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0006, and then run the DSP ALDVER
command to query the value of the Software Version parameter. In the
command output, the value of the Software Version parameter indicates the
software version B.
 Command used to query the port number and subunit number
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0007, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value is PORTX-SUBUNITY, where X indicates the port number
and Y indicates the subunit number.
 Command used to query the BOOT version and program running
address/mechanical tilt compensation (AISU)
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0008, and then run the DSP ALDVER

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 9


2 Application of RET/RAE Commissioning
Huawei ALD Software Commissioning Command Guide Commands

command to query the value of the Software Version parameter. The value of
the Software Version parameter indicates the address of the program running
area and the BOOT version. Command used to query the board temperature.
For the AISU, run the DSP RAEDEVICEDATA command to query the RET device
data. In the command output, the value of Antenna Serial No. is
QI0008QV0000XXXX, and the last four digits indicate the compensation value
in hexadecimal format.
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0009, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter shows the board temperature information.
 Command used to query the GPS algorithm information (AISU)
For the AISU, run the DSP RAEDEVICEDATA command to query the RET device
data. In the command output, the value of Antenna Serial No. is
QI0008QV0000XXXX, and the last four digits indicate the compensation value
in hexadecimal format.
 Command used to query the transparent transmission state
On the LMT or MAE, run the MOD RAEDEVICEDATA command with the
Antenna Serial No. parameter set to QI000A, and then run the DSP ALDVER
command to query the value of the Software Version parameter. In the
command output, the value of Software Version indicates the GPS algorithm
information.
 Command used to query the information of H version configure file
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI000C, and then run the DSP ALDVER
command to query the value of the Software Version parameter. The value of
the Software Version parameter indicates the information of H version
configure file.
 Command used to query port voltage
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI000D, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value of the Antenna Serial No. parameter indicates the port
voltage.
 Command used to query RET serial number binding status
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI000E, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value of the Antenna Serial No. parameter indicates the
information about the serial number binding status.
 Command used to query the azimuth compensation value (AISU)
On the LMT or MAE, run the MOD RAEDEVICEDATA command with the
Antenna Serial No. parameter set to QI000F, and then run the DSP
RAEDEVICEDATA command to query the value of the Actual Device Serial No.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 10


2 Application of RET/RAE Commissioning
Huawei ALD Software Commissioning Command Guide Commands

parameter. The value of the Actual Device Serial No. parameter is


QI000FQV0000XXXX, and the last four digits indicate the compensation value
in hexadecimal format.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 11


3 Application of REU Commissioning
Huawei ALD Software Commissioning Command Guide Commands

3 Application of REU Commissioning


Commands

This chapter describes the functions and application methods of REU


commissioning commands.
 Command used to configure the equipment mode
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV0000000X. The variable X
equals 0 or 1. The normal mode is used when X equals 0, and the
commissioning mode is used when X equals 1. It is recommended that the
commissioning mode be disabled. By default, the normal mode is used.
 Command used to enter the mini area
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV00000001 to enter the
commissioning mode. Then, run the MOD RETDEVICEDATA command with
the Antenna Serial No. parameter set to PI0005PV00000001 to enter the mini
area. In the mini area, only application-layer information query and software
upgrade are supported. If software needs to be upgraded again in the mini area,
you can switch the device from the mini area to the normal running area.
 Command used to set the visibility of REU SNs
On the LMT or MAE, choose an RET device which has set up a connection with
the BTS, and run the MOD RETDEVICEDATA command with the Antenna
Serial No. parameter set to PI0009PV0000000X. The variable X equals 0 or 1.
The value 0 indicates that the REU SN is invisible while the value 1 indicates
that the REU SN is visible and the REU can be upgraded or maintained. It is
recommended that REU SNs be invisible. By default, the REU SNs are invisible.
 Command for REU working mode switching
On the LMT or MAE, choose an RET/REU device which has set up a connection
with the BTS, and run the MOD RETDEVICEDATA command with the Antenna
Serial No. parameter set to PI000APV0000000X. The variable X equals 0 or 1.
The value 0 indicates that the link mutually exclusive mode is used while the

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 12


3 Application of REU Commissioning
Huawei ALD Software Commissioning Command Guide Commands

value 1 indicates that the co-site mode is used. By default, the link mutually
exclusive mode is used.
 Command used to query the status of the commissioning mode
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0004, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value QI0004QV00000000 indicates that the normal mode is
used, and the value QI0004QV00000001 indicates that the commissioning
mode is used.
 Command used to query the software version B
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0006, and then run the DSP ALDVER
command to query the value of the Software Version parameter. In the
command output, the value of the Software Version parameter indicates the
software version B.
 Command used to query the port number and subunit number
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI0007, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value is PORTX-SUBUNITY, where X indicates the port number
and Y indicates the subunit number.
 Command used to query the REU working mode
On the LMT or MAE, run the MOD RETDEVICEDATA command with the
Antenna Serial No. parameter set to QI000A, and then run the DSP
RETDEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value QI000AQV00000000 indicates that the link mutually
exclusive mode is used, and the value QI000AQV00000001 indicates that the
co-site mode is used.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 13


4 Application of TMA/COM Commissioning
Huawei ALD Software Commissioning Command Guide Commands

4 Application of TMA/COM
Commissioning Commands

This chapter describes the functions and application methods of TMA/COM


commissioning commands.
 Command used to turn on the logging switch
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to PI0003PV0000000X. The variable X
equals 0 or 1. The logging switch is turned off when X equals 0 and is turned on
when X equals 1. The log contains motor-related parameters, port voltages,
and other information. It cannot be viewed on the LMT or MAE, but can be
parsed to facilitate troubleshooting. After troubleshooting is complete, it is
recommended that the logging switch be turned off. By default, the switch is
turned off.
 Command used to configure the commissioning mode
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV0000000X. The variable X
equals 0 or 1. The normal mode is used when X equals 0, and the
commissioning mode is used when X equals 1. It is recommended that the
commissioning mode be disabled. By default, the normal mode is used.
 Command used to enter the mini area
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV00000001 to enter the
commissioning mode. Then, run the MOD TMADEVICEDATA command with
the Antenna Serial No. parameter set to PI0005PV00000001 to enter the mini
area. In the mini area, only application-layer information query and software
upgrade are supported. If software needs to be upgraded again in the mini area,
you can switch the device from the mini area to the normal running area.
 Command used to clear backplane data or extern flash data
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to PI0004PV00000001 to enter the
commissioning mode. Then, run the MOD TMADEVICEDATA command with

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 14


4 Application of TMA/COM Commissioning
Huawei ALD Software Commissioning Command Guide Commands

the Antenna Serial No. parameter set to PI0006PVXXXXXXXX. The variables


XXXXXXXX indicate the information of the extern flash. The command used to
clear data.
 Command used to configure the loading area
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to PI0007PV0000000X. The variable X
ranges from 0 to 1. The values 0, 1 indicate the software upgrade area,
software mini area, respectively. By default, the software upgrade area is used.
 Command used to set RAE serial number to be visible for log
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to PI0008PV0000000X. The variable X
ranges from 0 to 1. The values 0, 1 indicate RAE serial number invisible, RAE
serial number visible, respectively. By default, the RAE serial number is invisible.
 Command used to query the status of the commissioning mode
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to QI0004, and then run the DSP
TMADEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value QI0004QV00000000 indicates that the normal mode is
used, and the value QI0004QV00000001 indicates that the commissioning
mode is used.
 Command used to query the software version B
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to QI0006, and then run the DSP ALDVER
command to query the value of the Software Version parameter. In the
command output, the value of the Software Version parameter indicates the
software version B.
 Command used to query the port number and subunit number
On the LMT or MAE, run the MOD TMADEVICEDATA command with the
Antenna Serial No. parameter set to QI0007, and then run the DSP
TMADEVICEDATA command to query the value of the Antenna Serial No.
parameter. The value is PORTX-SUBUNITY, where X indicates the port number
and Y indicates the subunit number.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 15


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

5 Overview of Vendor Specific


Commands

5.1 AISG Command Format

5.2 Software Versions

5.3 Introduction to Vendor Specific Commands

5.1 AISG Command Format


The production command format complies with the AISG protocol. The command
formats, including the U frame and I frame commands, comply with the I frame
protocol.

Table 5-1 Vendor-defined command parameters and formats


No. Length Type Description
1 2 bytes ASCII code Command code
1+i Vendor specified Vendor specified

5.2 Software Versions


RET/RAE: equipment commands are used in ANT SAA V100R002C00, ANT SAA
V100R002C01, ANT RCU V400R002C02 and its patch versions, ANT RCU
V400R003C00, ANT RCU V400R003C01 and its patch versions and later versions.

REU: equipment commands are used in ANT REU V400R001C00 and ANT REU
V400R002C00.

TMA/COM: ANT TMA&COM V300R001C00, ANT TMA&COM V300R001C01

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 16


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

Table 5-2 Version mapping of vendor specific commands

Vendor Specidic Command ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT
RCU RCU REU REU SAA SAA TMA TMA RCU RCU RCU
V40 V40 V40 V40 V10 V10 &CO &CO V40 V50 V50
0R0 0R0 0R0 0R0 0R0 0R0 M M 0R0 0R0 0R0
02C 03C 01C 02C 02C 02C V30 V30 03C 02C 03C
02 00 00 00 00 01 0R0 0R0 01 00 00
01C 01C
00 01

Obtain the device temperature. Y N N N Y Y N N N N N

Get Capability Info N Y N N N N N N Y Y Y

Get Serial Mapping N N N N N N N N N N Y

Set Primary Info N N N N N N N N N N Y

Get Primary Info N N N N N N N N N N Y

Write the antenna electronic label. Y Y N N Y Y N N N N N

Read the antenna electronic label. Y Y N N Y Y N N Y Y Y

Read the electronic label of external Y Y N N Y Y N N N N N


devices.

Write the electronic label. Y Y Y Y Y Y Y Y N N N

Read the electronic label. Y Y Y Y Y Y Y Y Y Y Y

Write the start protocol. Y Y N N Y Y N N N N N

Read the start protocol. Y Y N N Y Y N N N N N

Set the working mode. Y Y N N Y Y N N N N N

Query the working mode. Y Y N N Y Y N N N N N

Set the special switch. N Y N N N Y N N N N N

Query the special switch. N Y N N N Y N N N N N

Write TMA configuration data. N N N N N N Y Y N N N

Read TMA configuration data. N N N N N N Y Y N N N

Set the transparent transmission N N N N N N Y Y N N N


switch.

Read the hardware version. N N N N N N N Y N N N

Read the current. N N N N N N Y Y N N N

Obtain the LNA current. N N N N N N Y Y N N N

Obtain the port voltage. N N N N N N Y Y N N N

Transmit continuous low level. N N N N N N Y Y N N N

Write the hardware version. N N N N N N Y Y N N N

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 17


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

Vendor Specidic Command ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT
RCU RCU REU REU SAA SAA TMA TMA RCU RCU RCU
V40 V40 V40 V40 V10 V10 &CO &CO V40 V50 V50
0R0 0R0 0R0 0R0 0R0 0R0 M M 0R0 0R0 0R0
02C 03C 01C 02C 02C 02C V30 V30 03C 02C 03C
02 00 00 00 00 01 0R0 0R0 01 00 00
01C 01C
00 01

Read motor parameters. Y Y N N N Y N N Y Y Y

Read configuration data. Y Y N N N Y N N Y Y Y

Quickly load the software. Y Y Y Y Y Y Y Y Y Y Y

Set the equipment mode. Y Y Y Y Y Y Y Y Y Y Y

Query the equipment mode. Y Y Y Y Y Y Y Y Y Y Y

Calibrate the acceleration sensor. N N N N Y Y N N N N N

Obtain the mechanical tilt. Y N N N Y Y N N N N N

Write the calibration result. N N N N Y Y N N N N N

Perform component self-check. Y Y N Y Y Y Y Y Y Y Y

Read GPS information. N N N N Y Y N N N N N

Query the length of stored data. N N N N Y Y N N N N N

Extend the calibration. N N N N Y Y N N N N N

Inspect the memory chip. N Y N N Y Y N N N N N

Log function commands Y Y N N Y Y Y Y Y Y Y

Set the downtilt compensation value. N N N N Y Y N N N N N

Query the downtilt compensation N N N N Y Y N N N N N


value.

Set the altitude compensation value. N N N N Y Y N N N N N

Query the altitude compensation N N N N Y Y N N N N N


value.

Set the azimuth compensation value. N N N N Y Y N N N N N

Query the azimuth compensation N N N N Y Y N N N N N


value.

Set the baseline length. N N N N Y Y N N N N N

Query the baseline length. N N N N Y Y N N N N N

Query the 2D weight. Y Y N N N Y N N Y N N

Write production information. Y Y Y Y Y Y Y Y N N N

Read production information. Y Y Y Y Y Y Y Y N N N

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 18


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

Vendor Specidic Command ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT
RCU RCU REU REU SAA SAA TMA TMA RCU RCU RCU
V40 V40 V40 V40 V10 V10 &CO &CO V40 V50 V50
0R0 0R0 0R0 0R0 0R0 0R0 M M 0R0 0R0 0R0
02C 03C 01C 02C 02C 02C V30 V30 03C 02C 03C
02 00 00 00 00 01 0R0 0R0 01 00 00
01C 01C
00 01

Write antenna capability information. Y N N N N N N N N N N

Read antenna capability information. Y N N N N Y N N N N N

Write the mapping relationship of N N N N N N N N N N N


subunits.

Read the mapping relationship of N N N N N N N N N N N


subunits.

Write additional data tables. Y Y N N N Y N N N N N

Read additional data tables. Y Y N N N Y N N N N N

Write the device temperature. N Y N N N Y N N N N N

Read the device temperature. N Y N N N Y N N N N N

Obtain the motor speed. N Y N N N Y N N N N N

Enter the high current mode. N Y N N N Y N N N N N

Upload data. N N N N N N N N N N N

Read motor parameters. Y Y N N N Y N N N Y Y

Read configuration data. Y Y N N N Y N N N Y Y

Read the number of receive queues. N Y N N Y Y Y Y N N N

Read the information about receive N Y N N Y Y Y Y N N N


queues.

Read the timer. N Y N N Y Y Y Y N N N

Query flash information. N Y Y Y Y Y Y Y N N N

Query the reset cause. N Y N N Y Y Y Y Y Y Y

Read the hall level. N Y N N N Y N N N N N

Read the number of running halls. N Y N N N Y N N N N N

Read the sequence of running halls. N Y N N N Y N N N N N

Obtain the hall interval. N Y N N N Y N N N N N

Obtain the motor speed. N Y N N N Y N N N N N

Set the motor speed. N Y N N N Y N N N N N

Set the duty cycle. N Y N N N Y N N N N N

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 19


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

Vendor Specidic Command ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT
RCU RCU REU REU SAA SAA TMA TMA RCU RCU RCU
V40 V40 V40 V40 V10 V10 &CO &CO V40 V50 V50
0R0 0R0 0R0 0R0 0R0 0R0 M M 0R0 0R0 0R0
02C 03C 01C 02C 02C 02C V30 V30 03C 02C 03C
02 00 00 00 00 01 0R0 0R0 01 00 00
01C 01C
00 01

Read the number of faulty halls. N Y N N N Y N N N N N

Set the motor mode. N Y N N N Y N N N N N

Set the flow control threshold. N Y N N N Y N N N N N

Set the motor speed and hall value. N Y N N N Y N N Y N N

Set the motor self-lock. N Y N N N Y N N N N N

Obtain the backplane format. N Y N N N N N N N N N

Reset the board. N Y N N Y Y Y Y N N N

Obtain the compilation time. N Y N N Y Y Y Y Y Y Y

Initialize the board. N Y N N N Y Y Y N N N

Set debugging parameters. N Y N N N N N N N N N

Set the print level. N Y N N N N N N N N N

Print the PWM information. N Y N N N Y N N N N N

Save the HWN serial number. N Y N N N Y N N N N N

Read the HWN serial number. N Y N N N Y N N N N N

Recover test exceptions. N Y N N N Y N N N N N

Obtain the ping information. N Y N N N N N N N N N

Set the ping reference point. N Y N N N N N N N N N

Set the ping exception point. N Y N N N N N N N N N

Terminate the ping process. N Y N N N N N N N N N

Query the ping port control N Y N N N N N N N N N


information.

Obtain the ping information. N Y N N N N N N N N N

Obtain the information about N Y N N N Y N N Y N N


calibration failure.

Print the direction pattern N Y N N N Y N N Y N N


information.

Set the GNGGA. N N N N Y Y N N N N N

Obtain the baud rate of the satellite N N N N Y Y N N N N N

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 20


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

Vendor Specidic Command ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT ANT
RCU RCU REU REU SAA SAA TMA TMA RCU RCU RCU
V40 V40 V40 V40 V10 V10 &CO &CO V40 V50 V50
0R0 0R0 0R0 0R0 0R0 0R0 M M 0R0 0R0 0R0
02C 03C 01C 02C 02C 02C V30 V30 03C 02C 03C
02 00 00 00 00 01 0R0 0R0 01 00 00
01C 01C
00 01

card.

Read DMA cache data. N N N N Y Y N N N N N

Read the software running time. N N N N Y Y N N N N N

Read the link information. N N N N Y Y N N N N N

Reset the satellite card. N N N N Y Y N N N N N

Obtain the buffer information. N N Y Y N N N N N N N

Release the remote cache information. N N Y Y N N N N N N N

Obtain the remote port information. N N Y Y N N N N N N N

Obtain the device status. N N Y Y N N N N N N N

Obtain the FIFO information. N N Y Y N N N N N N N

Obtain the port calibration status. N N Y Y N N N N N N N

Clear the remote waiting status. N N Y Y N N N N N N N

Obtain remote data. N N Y Y N N N N N N N

Restore the remote status. N N Y Y N N N N N N N

Get Ant Bom N Y N N N N N N N Y Y

Get PhaseInfo Index N Y N N N N N N N Y Y

Obtain the remote alarm status. N N Y Y N N N N N N N

Query parameter information (U Y Y Y Y Y Y Y Y Y Y Y


frame).

Set parameter information (U frame). Y Y Y Y Y Y Y Y Y Y Y

Get All Serials (U frame) N Y N N N N N N Y Y Y

Write equipment flag (U frame) N Y N N N N N N Y Y Y

Clear equipment flag (U frame) N Y N N N N N N Y Y Y

Jump to equipment(U frame) N Y N N N N N N Y Y Y

Identify Huawei base station (U N Y N N N N Y Y Y Y Y


frame).

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 21


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

5.3 Introduction to Vendor Specific Commands


Table 5-3 Vendor specific commands

No Command Command Description


. Word

1 Obtain the 0x01 Queries the real-time temperature of a


device device. The value is of the short type, and
temperature. the unit is °C.

2 Get Capability 0x03 Returns antenna capability info.


Info

3 Get Serial 0x04 Returns 3.0 protocol subunit of 2.0 protocol


Mapping

4 Set Primary 0x05 Delivers multi bytes of primary info.


Info

5 Get Primary 0x06 Delivers ports number and returns primary


Info info.

6 Write the 0x0D Delivers and writes multiple frames with the
antenna 1-byte frame number and electronic label
electronic label. content.

7 Read the 0x0E Delivers a multi-frame read command with


antenna a 1-byte frame number. The response
electronic label. message contains the frame number and
tag content.

8 Read the 0x0F Delivers a multi-frame read command with


electronic label a 1-byte frame number. The response
of external message contains the frame number and
devices. tag content.

9 Write the 0x10 Delivers and writes multiple frames with the
electronic label. 1-byte frame number and electronic label
content.

10 Read the 0x11 Delivers a multi-frame read command with


electronic label. a 1-byte frame number. The response
message contains the frame number and
tag content.

11 Write the start 0x20 Delivers a 1-byte protocol flag, 0: 1.1


protocol. protocol, 1: 2.0 protocol.

12 Read the start 0x21 Returns a 1-byte protocol flag, 0: 1.1


protocol. protocol, 1: 2.0 protocol.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 22


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word

13 Set the working 0x25 Delivers a 1-byte working mode command,


mode. 0x01: RET, 0x11: MRET.

14 Query the 0x26 Returns the 1-byte working mode, 0x01:


working mode. RET, 0x11: MRET.

15 Set the special 0x27 Delivers a command in the PI PL PV format,


switch. 0x03/0x04: transparent transmission switch.

16 Query the 0x28 Delivers a command with multiple PIs,


special switch. 0x03/0x04: transparent transmission switch.
The switch status is returned.

17 Write TMA 0x30 Delivers and writes multiple frames with the
configuration 1-byte frame number and configuration
data. data.

18 Read TMA 0x31 Delivers a multi-frame read command with


configuration a 1-byte frame number. The response
data. message contains the frame number and
configuration data.

19 Set the 0x38 Delivers a 1-byte type message (0:


transparent combiner, 1: TMA), 1-byte attribute (0:
transmission electrical, 1: signal, 2: load), 1-byte port ID,
switch. and 1-byte status.

20 Read the 0x39 Returns the board type and board version,
hardware both of unsigned short type.
version.

21 Read the 0xE8 Returns the maximum, current, and


current. minimum current of multiple LNAs. Each
value contains two bytes.

22 Obtain the LNA 0xE9 Returns the current of multiple LNAs. The
current. current is of the unsigned short type.

23 Obtain the port 0xEA Obtains the voltage of the current port. The
voltage. value is of the unsigned short type, and the
unit is 0.1 V.

24 Transmit 0xEB Delivers a 1-byte port ID and a 1-byte


continuous low switch status, 0: disabled, 1: enabled.
level.

25 Write the 0x37 Delivers the hardware version number in


hardware ASCII code, no more than 19 bytes.
version.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 23


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word

26 Read motor 0x41 Delivers a multi-frame read command with


parameters. a 1-byte frame number. The response
message contains the frame number and
motor parameters.

27 Read 0x43 Delivers a multi-frame read command with


configuration a 1-byte frame number. The response
data. message contains the frame number and
configuration data.

28 Quickly load 0x44/0x45 Starts software loading/loads


the software. /0x46 software/stops software loading. The
loading process is the same as that defined
in the normal software loading protocol.

29 Set the 0x50 Delivers a 1-byte status flag, 0: disabled, 1:


equipment enabled.
mode.

30 Query the 0x51 Returns a 1-byte status flag, 0: disabled, 1:


equipment enabled.
mode.

31 Calibrate the 0x52 Delivers a 2-byte command with the angle


acceleration data. 0x00 is returned.
sensor.

32 Obtain the 0x53 Returns a mechanical tilt value of the short


mechanical tilt. type.

33 Write the 0x54 Delivers a 1-byte command with the


calibration calibration result (0: failed, 1: successful, 2:
result. extended calibration successful), and 0x00
is returned.

34 Perform 0x56 Delivers a 1-byte component ID, 0: flash, 1:


component acceleration sensor, 2: temperature sensor.
self-check.

35 Read GPS 0x57 Delivers a 1-byte command with the


information. satellite card number (1: master, 2: slave).
The number of satellites and the
signal-to-noise ratio of each satellite are
returned.

36 Query the 0x58 Returns the data length of the unsigned int
length of type.
stored data.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 24


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word

37 Extend the 0x59 Delivers the calibration value of the


calibration. unsigned short type.

38 Inspect the 0x5F Delivers a 1-byte component ID (0:


memory chip. EEPROM, 1: on-chip flash, 2: off-chip flash,
3: memory information), the start address
of the unsigned int type, and the length of
the unsigned int type.

39 Log function 0x60 Delivers the command in the PI(0x00)


commands PL(0x01) PV format, 0: disabled, 1: enabled.

40 Set the 0x62 Delivers a 2-byte command with the tilt


downtilt compensation value. The saving status is
compensation returned.
value.

41 Query the 0x63 Returns a 2-byte tilt compensation value.


downtilt
compensation
value.

42 Set the altitude 0x64 Delivers a 4-byte command with the


compensation altitude compensation value. The saving
value. status is returned.

43 Query the 0x65 Returns a 4-byte altitude compensation


altitude value.
compensation
value.

44 Set the azimuth 0x66 Delivers a 2-byte command with the


compensation azimuth compensation value. The saving
value. status is returned.

45 Query the 0x67 Returns a 2-byte azimuth compensation


azimuth value.
compensation
value.

46 Set the baseline 0x68 Delivers a 2-byte command with the


length. baseline length. The saving status is
returned.

47 Query the 0x69 Returns a 2-byte baseline length.


baseline length.

48 Query the 2D 0x73 Delivers a 1-byte subunit number and a


weight. 1-byte field number, and different

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 25


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word
information for different fields are returned.
The command is the same as that for
querying the 2D weight value of the RAE.

49 Write 0x81 Delivers the information in the format of


production PIx (02: semi-integrated identifier; 03: RET
information. identifier; 04: device name; 05: vendor ID;
06: device serial number; 07: device type; 08:
motor quantity; 09: frequency band range;
0A: antenna bar code; 0C: serial number;
0D: backplane serial number; 0E: external
code; 0F: backplane identifier; 34: actual
trip; 35: shift trip) and PVx (specific value).

50 Read 0x80 Delivers PIx to obtain the values of different


production sub-commands.
information.

51 Write antenna 0x82 Delivers a 1-byte table ID with the frame


capability number and data of the unsigned short
information. type.

52 Read antenna 0x83 Delivers a 1-byte table ID with the frame


capability number of the unsigned short type. Specific
information. data is returned.

53 Write the 0x84 Delivers multiple 1-byte frame numbers


mapping and data.
relationship of
subunits.

54 Read the 0x85 Delivers a 1-byte frame number and specific


mapping data is returned.
relationship of
subunits.

55 Write 0x86 Delivers a 1-byte frame number and data


additional data with the table ID (05: module information
tables. file; 06: antenna information file).

56 Read additional 0x87 Delivers a 1-byte table ID and 1-byte frame


data tables. number. Specific data is returned.

57 Write the 0x88 Delivers a temperature value of the short


device type.
temperature.

58 Read the device 0x89 Returns the current temperature of the


temperature. short type. The unit is °C.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 26


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word

59 Obtain the 0x90 Delivers a 1-byte motor ID, and a 1-byte


motor speed. motor speed is returned. The unit is rpm.

60 Enter the high 0x91 Delivers a 1-byte status, 0: disabled, 1:


current mode. enabled.

61 Upload data. 0x90 Delivers the 1-byte component ID (0:


off-chip FLASH, 1: EEPROM), the start
address of the unsigned int type, and the
length of the unsigned int type. Specific
length data is returned.

62 Read motor 0xB1 Delivers a multi-frame read command with


parameters. a 1-byte subunit and 1-byte frame number.
The response message contains the frame
number and motor parameters.

63 Read 0xB3 Delivers a multi-frame read command with


configuration a 1-byte subunit and 1-byte frame number.
data. The response message contains the frame
number and configuration data.

64 Read the 0xD0 Delivers a 1-byte message format, 0: service


number of message, 1: message queue. A 1-byte
receive queues. number is returned.

65 Read the 0xD1 Delivers a 1-byte message format and a


information 1-byte message index, and the detailed
about receive information is returned.
queues.

66 Read the timer. 0xD2 Returns a 1-byte number of timers and the
timer list.

67 Query flash 0xD4 Delivers a 1-byte component ID (0:


information. EEPROM; 1: on-chip flash; 2: off-chip flash;
3: memory), and the start address of the
unsigned int type. The 60-byte length data
is returned.

68 Query the reset 0xD5 Returns the 1-byte reset cause and the
cause. power-on time (minutes) of the unsigned
int type.

69 Read the hall 0xD6 Delivers a 1-byte motor ID and three 1-byte
level. states of pins are returned.

70 Read the 0xD7 Delivers a 1-byte motor ID and the number


number of of halls of the unsigned int type is returned.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 27


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word
running halls.

71 Read the 0xD8 Delivers a 1-byte motor ID and 50 1-byte


sequence of hall states are returned.
running halls.

72 Obtain the hall 0xD9 Delivers a 1-byte motor ID and 50 1-byte


interval. hall intervals are returned.

73 Obtain the 0xDA Delivers a 1-byte motor ID and a 1-byte


motor speed. motor rotational speed and unsigned short
duty cycle are returned.

74 Set the motor 0xDB Delivers a 1-byte motor number and a


speed. 1-byte rotational speed.

75 Set the duty 0xDC Delivers a 1-byte motor ID and the duty
cycle. cycle of the unsigned int type.

76 Read the 0xDD Delivers a 1-byte motor ID and the number


number of of the unsigned int type is returned.
faulty halls.

77 Set the motor 0xDE Delivers a 1-byte motor ID and 1-byte


mode. motor mode (0: speed adjustment mode, 1:
fixed duty cycle).

78 Set the flow 0xDF Delivers a 1-byte motor ID and the flow
control control threshold of the unsigned int type.
threshold.

79 Set the motor 0xE0 Deliver a 1 byte motor ID, number of return
speed and hall times of the unsigned int type, 1-byte motor
value. direction, number of steps of the unsigned
int type, and speed of the unsigned short
type.

80 Set the motor 0xE1 Delivers a 1-byte motor ID and the duty
self-lock. cycle of the unsigned int type.

81 Obtain the 0xE2 Returns a 1-byte back plane status, 0: C02,


backplane 1-C03, 2: C02 valid, 3: invalid.
format.

82 Reset the 0xE3 Performs warm reset on the board.


board.

83 Obtain the 0xE4 Returns the specific compilation time and


compilation date (ASCII code).
time.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 28


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word

84 Initialize the 0xE5 Restores the board to the initial state.


board.

85 Set debugging 0xE6 Delivers a 1-byte subunit number, the


parameters. startup current of the unsigned short type,
the operating current of the unsigned short
type, and the motor rotational speed of the
unsigned short type.

86 Set the print 0xE7 Delivers a 1-byte print level, 0: low, 1: high.
level.

87 Print the PWM 0xE8 Delivers a 1-byte motor ID.


information.

88 Save the HWN 0xEA Saves the HWN serial number.


serial number.

89 Read the HWN 0xEB Returns a 19-byte HWN sequence number.


serial number.

90 Recover test 0xEC Delivers a 1-byte test mode, 0:


exceptions. configuration data, 1: serial number, 2:
backplane configuration data, 3: backplane
configuration data.

91 Obtain the ping 0xA0 Obtains the number of subunits of ping


information. information.

92 Set the ping 0xA1 Queries ping related information.


reference point.

93 Set the ping 0xA2 Sets the phase shifter to the specified ping
exception feature reference point.
point.

94 Terminate the 0xA3 Sets the phase shifter to the specified ping
ping process. feature exception point.

95 Query the ping 0xA4 Restores the phase shifter to the original
port control downtilt.
information.

96 Obtain the ping 0xA5 Obtains the port control information of the
information. ping feature.

97 Obtain the 0xF0 Returns the calibration failure information.


information
about
calibration

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 29


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word
failure.

98 Print the 0xE9 Prints detailed direction pattern


direction information in logs.
pattern
information.

99 Set the 0xD5 Delivers a 1-byte command for configuring


GNGGA. the satellite card (1: enabling the GNGGA;
2: enabling the EPH; 3: querying the version
of the master BTS; 4: querying the version of
the slave BTS). The configuration result is
returned.

10 Obtain the 0xD6 Returns the baud rates of the two satellite
0 baud rate of cards. The baud rates are eight bytes in
the satellite total.
card.

10 Read DMA 0xD7 Delivers a 1-byte command with the


1 cache data. satellite card number (1: master, 2: slave),
and the buffer in-position status is returned.

10 Read the 0xED After receiving the command, the software


2 software running time is printed in the log.
running time.

10 Read the link 0xEF Returns the communication time, port


3 information. number, and disconnection cause of a
specific subunit.

10 Reset the 0xF3 Delivers a 1-byte command with the


4 satellite card. satellite card number (1: master, 2: slave),
and the satellite card reset status is
returned.

10 Get Ant Bom 0xF4 Returns antenna bom code.


5

10 Get PhaseInfo 0xF5 Returns file’s index and length.


6 Index

10 Obtain the 0x90 Obtains the idle status of the received and
7 buffer sent messages in the buffer.
information.

10 Release the 0x91 Releases the message to be sent on the


8 remote cache remote RET device.
information.

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 30


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word

10 Obtain the 0x92 Obtains the status of the remote port of the
9 remote port remote RET device.
information.

11 Obtain the 0x93 Obtains the status of the remote RET


0 device status. device.

11 Obtain the 0x94 Obtains the I frames to be sent by the


1 FIFO remote RET device.
information.

11 Obtain the port 0x95 Obtains the port calibration status of the
2 calibration remote RET device.
status.

11 Clear the 0x96 Clears the status of messages waiting for


3 remote waiting response on the remote RET device.
status.

11 Obtain remote 0x97 Obtains the data information of the remote


4 data. RET device.

11 Restore the 0x98 Restores the port of the remote RET device
5 remote status. to the idle state.

11 Obtain the 0x99 Obtains the alarm information of the


6 remote alarm remote RET device.
status.

11 Query 0x02 Delivers data in the PI PL format, PI (01:


7 parameter antenna identifier, 02: antenna bar code, 03:
information (U slot number, 04: number of ports, 05:
frame). frequency band information).
Corresponding data is returned.

11 Set parameter 0x03 Delivers the PI PL PV format data, PI: 01:


8 information (U equipment mode; 02: restore the default
frame). serial number; 03: restore the default serial
number of the backplane; 04: modify the
number of serial numbers.

11 Get all serials 0x05 Return all serials


9 (U frame)

12 Write 0x06 Delivers equipment value


0 equipment flag
(U frame)

12 Clear 0x07 Clear equipment flag


equipment flag

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 31


Huawei ALD Software Commissioning Command Guide 5 Overview of Vendor Specific Commands

No Command Command Description


. Word
1 (U flag)

12 Jump to 0x08 Delivers 1-byte equipment command 01:


2 equipment (U Business; 02: Equipment
frame)

12 Read the data 0x88 Delivers the frequency point, downtilt, pitch
3 of a specified angle, azimuth, and 1-byte channel number
frequency (U of the unsigned short type, and the phase
frame). data of the specified frequency is returned.

12 Write the AAS 0x86 Delivers a 1-byte table ID, a 1-byte frame
4 data table (U number, and specific data.
frame).

12 Read the 0x87 Delivers a 1-byte table ID and 1-byte frame


5 amplitude and number. Specific data is returned.
phase table (U
frame).

12 Identify 0xFF Identifies Huawei devices.


6 Huawei base
station (U
frame).

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 32


Huawei ALD Software Commissioning Command Guide A Appendix

A Appendix

Acronyms and Abbreviations


Acronym or Full Name
Abbreviation

LMT Local Maintenance Terminal

RCU Remote Control Unit

RET Remote Electrical Tilt

AISG Antenna Interface Standard Group

RAE Remote eAntenna Extension

ALD Antenna Line Device

REU RET Expansion Unit

TMA Tower Mounted Amplifier

COM Combiner

Issue 08 (2021-12-06) Copyright © Huawei Technologies Co., Ltd. 33