Untitled

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

Bill of quantity for the work "Replacement of damage roof sheets and provision for dining room alongwith

kitchen and
common toilet and extension of green room, etc at Officer's Club Bhurkunda under Bhurkunda Project, Barka-Sayal
Area".
S.N Description of work Qty. Unit AR Amount Remarks
1 PART-A "Dining Room" Earth work in excavation CPWD-
by mechanical means (Hydraulic excavator) / 2014
manual means in foundation trenches or drains (not revised rate
exceeding 1.5 m in width or 10 sqm on plan), 2.8.1 2014
including dressing of sides and ramming of bottoms, 48.77 cum 204.50 9,973.47 updation
lift upto 1.5 m, including getting out the excavated rate of
soil and disposal of surplus excavated soil as 2020
directed, within a lead of 50 m. 2.8.1 All kinds of
soil.
2 Providing and laying in position cement concrete of 4.1.8
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :1:4:8 (1 29.50 cum 4,182.08 1,23,388.57
Cement : 4 coarse sand : 8 graded stone aggregate
40 mm nominal size)
3 Providing and laying in position specified grade of 5.1.2
reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement -
8.12 cum 5,935.93 48,199.75
All work up to plinth level : 1:1.5:3 (1 cement : 1.5
coarse sand : 3 graded stone aggregate 20 mm
nominal size
4 Reinforced cement concrete work in walls (any 5.2.2
thickness), including attached pilasters, buttresses,
plinth and string courses, fillets, columns, pillars,
piers, abutments, posts and struts etc. up to floor five
9.21 cum 7,030.17 64,747.87
level, excluding cost of centering, shuttering,
finishing and reinforcement :1:1.5:3 (1 cement : 1.5
coarse sand : 3 graded stone aggregate
20 mm nominal size)
5 Steel reinforcement for R.C.C. work including 5.22.6
straightening, cutting, bending, placing in position
812 kg 81.69 66,332.28
and binding all complete upto plinth level. Thermo-
Mechanically Treated bars
6 Steel reinforcement for R.C.C. work including 5.22A.6
straightening, cutting, bending, placing in position
828.9 kg 81.69 67,712.84
and binding all complete above plinth level.
Thermo-Mechanically Treated bars
7 Centering and shuttering including strutting, 5.9.1
propping etc. and removal of form for : 5.9.1
40.5 sqm 228.07 9,236.84
Foundations, footings, bases of columns, etc. for
mass concrete
8 Centering and shuttering including strutting, 5.9.6
propping etc. and removal of form for : Columns, 76.15 sqm 575.98 43,860.88
Pillars, Piers, Abutments, Posts and Struts
9 Centering and shuttering including strutting, 5.9.5
propping etc. and removal of form for : Lintels,
19.6 sqm 417.20 8,177.12
beams, plinth beams, girders, bressumers and
cantilevers
10 Centering and shuttering including strutting, 5.9.3
propping etc. and removal of form for : Suspended
4.31 sqm 523.45 2,256.07
floors, roofs, landings, balconies and access
platform
11 Supply of good quality stone dust. Item Code
1159,
78.4 cum 1,265.00 99,176.00
CPWD
2014
12 Supplying and filling in plinth with Jamuna sand 2.27
under floors, including watering, ramming, 16.8 cum 823.24 13,830.43
consolidating and dressing complete.
13 Providing and laying vitrified floor tiles in different 11.41.2
sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and
conforming to IS : 15622, of approved make, in all
colours and shades, laid on 20mm thick cement 128 sqm 1,202.26 1,53,889.28
mortar 1:4 (1 cement : 4 coarse sand), including
grouting the joints with white cement and matching
pigments etc., complete. Size of Tile 600x600 mm
14 Providing and fixing Ist quality ceramic glazed wall 11.36
tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-
13.68 sqm 910.04 12,449.35
Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white cement
mixed with pigment of matching shade complete.
15 Brick work with common burnt clay F.P.S. (non 6.1.2
modular) bricks of class designation 7.5 in
22.45 cum 5,537.15 1,24,309.02
foundation and plinth in: Cement mortar 1:6 (1
cement : 6 coarse sand)
16 Providing and laying damp-proof course 40 mm 4.1
thick with cement concrete 1:2:4 (1 cement : 2
11.18 sqm 272.90 3,051.02
coarse sand : 4 graded stone aggregate 12.5 mm
nominal size).
17 Brick work with common burnt clay F.P.S. (non 6.4.2
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level 51.62 sqm 6,546.52 3,37,931.36
in all shapes and sizes in : Cement mortar 1:6 (1
cement : 6 coarse sand)
18 Providing and fixing T-iron frames for doors, 10.13.1
windows and ventilators of mild steel Tee-sections,
joints mitred and welded, including fixing of
necessary butt hinges and screws and applying a
priming coat of approved steel primer. 10.13.1 37.8 kg 75.30 2,846.34
Fixing with 15x3 mm lugs 10 cm long embedded in
cement concrete block 15x10x10 cm of C.C. 1:3:6
(1 Cement : 3 coarse sand : 6 graded stone aggregate
20 mm nominal size)
19 Providing and fixing ISI marked flush door shutters 9.21.2
conforming to IS : 2202 (Part I) non-decorative type,
core of block board construction with frame of 1st
class hard wood and well matched commercial 3 ply
4.91 sqm 1,590.67 7,810.19
veneering with vertical grains or cross bands and
face veneers on both faces of shutters: 30 mm thick
including ISI marked Stainless Steel butt hinges
with necessary screws
20 Providing and fixing aluminium work for doors, 21.1.2.1
windows, ventilators and partitions with extruded
built up standard tubular sections/ appropriate Z
sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with
dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/
neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat
angle, Aluminium snap beading for glazing /
10.8 meter 430.99 4,654.69
paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing, paneling
and dash fasteners to be paid for separately) : For
shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making
provision for fixing of fittings wherever required
including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent
or dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15
21 Providing and fixing glazing in aluminium door, 21.3.3
window, ventilator shutters and partitions etc. with
EPDM rubber / neoprene gasket etc. complete as
per the architectural drawings and the directions of 3.6 sqm 786.46 2,831.26
engineer-in-charge. (Cost of aluminium snap
beading shall be paid in basic item): With float
glass panes of 8 mm thickness
22 Providing and fixing M.S. grills of required pattern 9.48.1
in frames of windows etc. with M.S. flats, square or
round bars etc. including priming coat with 54 kg 144.96 7,827.84
approved steel primer all complete. 9.48.1 Fixed to
steel windows by welding
23 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine 13.1.2
374.22 sqm 191.77 71,764.17
sand
24 Providing and applying white cement based putty of 13.8
average thickness 1 mm, of approved brand and
167.76 sqm 103.63 17,384.97
manufacturer, over the plastered wall surface to
prepare the surface even and smooth complete
25 Making plinth protection 50 mm thick of cement 4.17
concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) over 75mm
49.8 meter 464.75 23,144.55
thick bed of dry brick ballast 40 mm nominal size,
well rammed and consolidated and grouted with fine
sand, including finishing the top smooth.
26 Distempering with oil bound washable distemper of 13.41.1
approved brand and manufacture to give an even
shade : 13.41.1 New work (two or more coats) over 167.76 sqm 118.66 19,906.40
and including water tinnable priming coat with
cement primer
27 Finishing walls with water proofing cement paint of 13.44.1
required shade : 13.44.1 New work (Two or more 193.26 sqm 71.00 13,721.46
coats applied @ 3.84 kg/10 sqm
28 Painting with synthetic enamel paint of approved 13.61.1
brand and manufacture to give an even shade : 4.68 sqm 87.01 407.21
13.61.1 Two or more coats on new work
29 Providing and fixing false ceiling at all height 12.45.1
including providing and fixing of frame work made
of special sections, power pressed from M.S. sheets
and galvanized with zinc coating of 120 gms/sqm
(both side inclusive) as per IS : 277 and consisting
of angle cleats of size 25 mm wide x 1.6 mm thick
with flanges of 27 mm and 37mm, at 1200 mm
centre to centre, one flange fixed to the ceiling with
dash fastener 12.5 mm dia x 50mm long with 6mm
dia bolts, other flange of cleat fixed to the angle
hangers of 25x10x0.50 mm of required length with
nuts & bolts of required size and other end of angle
hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200 mm
centre to centre, to which the ceiling section 0.5 mm
thick bottom wedge of 80 mm with tapered flanges
of 26 mm each having lips of 10.5 mm, at 450 mm
centre to centre, shall be fixed in a direction
perpendicular to G.I. intermediate channel with
connecting clips made out of 2.64 mm dia x 230 mm
long G.I. wire at every junction, including fixing
128 sqm 892.53 1,14,243.84
perimeter channels 0.5 mm thick 27 mm high having
flanges of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl
plugs at 450 mm centre, with 25mm long dry wall
screws @ 230 mm interval, including fixing of
gypsum board to ceiling section and perimeter
channel with the help of dry wall screws of size 3.5
x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square
edges of the board with recomme-nded jointing
compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on
both sides of joint and two coats of primer suitable
for board, all as per manufacturer’s specification and
also including the cost of making openings for light
fittings, grills, diffusers, cutouts made with frame of
perimeter channels suitably fixed, all complete as
per drawings, specification and direction of the
Engineer in Charge but excluding the cost of
painting with 12.5 mm thick tapered edge gypsum
plain board conforming to IS: 2095- Part I
30 Wall painting with acrylic emulsion paint of 13.60.1
approved brand and manufacture to give an even 128 sqm 98.41 12,596.48
shade : 13.60.1 Two or more coats on new work
31 Extra for providing and fixing wind ties of 40x 6 12.11
224 meter 116.59 26,116.16
mm flat iron section.
32 Providing and fixing ridges and hips in fibre cement 12.12.2
high impact polypropylene reinforced roofing with
16 meter 348.52 5,576.32
suitable fixing accessories or self drilling fastener
and EPDM washer etc. complete.
33 Providing and fixing precoated galvanised iron 12.5
profile sheets (size, shape and pitch of corrugation
as approved by Engineer-in-charge) 0.50 mm (+
0.05 %) total coated thickness with zinc coating 120
grams per sqm as per IS: 277, in 240 mpa steel
grade, 5-7 microns epoxy primer on both side of the
sheet and polyester top coat 15-18 microns. Sheet 166.72 sqm 607.00 1,01,199.04
should have protective guard film of 25 microns
minimum to avoid scratches during transportation
and should be supplied in single length upto 12
metre or as desired by Engineerin-charge. The sheet
shall be fixed using self drilling / self tapping screws
of size (5.5x 55 mm) with EPDM seal, complete
upto any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters and
trusses and including cutting to size and shape
wherever required.
34 Structural steel work riveted, bolted or welded in 10.2
built up sections, trusses and framed work, including
3638.15 kg 73.76 2,68,349.94
cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer all complete.
35 PART-B "Kitchen Room" Earth work in 2.8.1
excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or
drains (not exceeding 1.5 m in width or 10 sqm on
plan), including dressing of sides and ramming of 20.25 cum 204.50 4,141.13
bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil
as directed, within a lead of 50 m. 2.8.1 All kinds of
soil
36 Providing and laying in position cement concrete of 4.1.8
specified grade excluding the cost of centering and
shuttering - All work up to plinth level : 1:4:8 (1 6.98 cum 4,182.08 29,190.92
Cement : 4 coarse sand : 8 graded stone aggregate
40 mm nominal size)
37 Brick work with common burnt clay F.P.S. (non 6.1.2
modular) bricks of class designation 7.5 in
12.19 cum 5,537.15 67,497.86
foundation and plinth in: Cement mortar 1:6 (1
cement : 6 coarse sand)
38 Brick work with common burnt clay F.P.S. (non 6.4.2
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level 14.75 cum 6,546.52 96,561.17
in all shapes and sizes in : Cement mortar 1:6 (1
cement : 6 coarse sand)
39 Providing and fixing M.S. grills of required pattern 9.48.1
in frames of windows etc. with M.S. flats, square or
round bars etc. including priming coat with 410.63 kg 144.96 59,524.92
approved steel primer all complete. 9.48.1 Fixed to
steel windows by welding
40 Reinforced cement concrete work in beams, 5.3
suspended floors, roofs having slope up to 15°
landings, balconies, shelves, chajjas, lintels, bands,
plain window sills, staircases and spiral stair cases
3.4 cum 7,342.78 24,965.45
up to floor five level, excluding the cost of
centering, shuttering, finishing and reinforcement,
with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).
41 Steel reinforcement for R.C.C. work including 5.22.6
straightening, cutting, bending, placing in position
272.24 kg 81.69 22,239.29
and binding all complete upto plinth level. Thermo-
Mechanically Treated bars
42 Centering and shuttering including strutting, 5.9.6
propping etc. and removal of form for : Columns, 7.5 sqm 575.98 4,319.85
Pillars, Piers, Abutments, Posts and Struts
43 Centering and shuttering including strutting, 5.9.5
propping etc. and removal of form for : Lintels,
7.5 sqm 417.20 3,129.00
beams, plinth beams, girders, bressumers and
cantilevers
44 Centering and shuttering including strutting, 5.9.3
propping etc. and removal of form for : Suspended
12.63 sqm 523.45 6,611.17
floors, roofs, landings, balconies and access
platform
45 Supplying and filling in plinth with Jamuna sand 2.27
under floors, including watering, ramming, 7.2 cum 823.24 5,927.33
consolidating and dressing complete.
46 Dry brick on edge flooring in required pattern with 11.2
bricks of class designation 7.5 on a bed of 12 mm
36 sqm 638.62 22,990.32
mud mortar, including filling joints with Jamuna
sand, with common burnt clay non modular bricks.
47 Cement concrete flooring 1:2:4 (1 cement : 2 coarse 11.3.1
sand : 4 graded stone aggregate) finished with a
floating coat of neat cement, including cement
36 sqm 380.32 13,691.52
slurry, but excluding the cost of nosing of steps etc.
complete. 11.3.1 40 mm thick with 20 mm nominal
size stone aggregate
48 12 mm cement plaster finished with a floating coat 13.7.2
45.68 sqm 254.17 11,610.49
of neat cement of mix : 1:4 (1 cement: 4 fine sand
49 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine 13.1.2
134.76 sqm 191.77 25,842.93
sand
50 6 mm cement plaster of mix : 13.16.1 1:3 (1 cement 13.16.1
23.22 sqm 172.36 4,002.20
: 3 fine sand)
51 Providing and fixing precoated galvanised iron 12.5
profile sheets (size, shape and pitch of corrugation
as approved by Engineer-in-charge) 0.50 mm (+
0.05 %) total coated thickness with zinc coating 120
grams per sqm as per IS: 277, in 240 mpa steel
grade, 5-7 microns epoxy primer on both side of the
sheet and polyester top coat 15-18 microns. Sheet
should have protective guard film of 25 microns
minimum to avoid scratches during transportation 45.54 sqm 607.00 27,642.78
and should be supplied in single length upto 12
metre or as desired by Engineerin-charge. The sheet
shall be fixed using self drilling / self tapping screws
of size (5.5x 55 mm) with EPDM seal, complete
upto any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters and
trusses and including cutting to size and shape
wherever required.
52 Structural steel work riveted, bolted or welded in 10.2
built up sections, trusses and framed work, including
144 kg 73.76 10,621.44
cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer all complete.
53 Extra for providing and fixing wind ties of 40x 6 12.11
48 meter 116.59 5,596.32
mm flat iron section.
54 Providing and fixing M.S. fan clamp type I or II of 10.17
16 mm dia M.S. bar, bent to shape with hooked ends
in R.C.C. slabs or beams during laying, including 2 each 164.27 328.54
painting the exposed portion of loop, all as per
standard design complete.
55 White washing with lime to give an even shade : 13.37.1
13.37.1 New work (three or more coats) 46.95 sqm 20.52 963.41

56 Finishing walls with water proofing cement paint of 13.44.1


required shade : 13.44.1 New work (Two or more 90.72 sqm 71.00 6,441.12
coats applied @ 3.84 kg/10 sqm
57 Making plinth protection 50 mm thick of cement 4.17
concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) over 75mm
11.61 sqm 464.75 5,395.75
thick bed of dry brick ballast 40 mm nominal size,
well rammed and consolidated and grouted with fine
sand, including finishing the top smooth.
58 Painting with synthetic enamel paint of approved 13.61.1
brand and manufacture to give an even shade : 62.85 sqm 87.01 5,468.58
13.61.1 Two or more coats on new work
59 Providing and fixing Chlorinated Polyvinyl 18.9.2
Chloride (CPVC) pipes, having thermal stability for
hot & cold water supply including all CPVC plain &
brass threaded fittings This includes jointing of
75 meter 226.83 17,012.25
pipes & fittings with one step CPVC solvent cement
,trenching ,refilling & testing of joints complete as
per direction of Engineer in Charge. External work
20 mm nominal outer dia Pipes
60 Providing and fixing PTMT bib cock of approved 18.54.1
quality and colour. 18.54.1 15mm nominal bore, 86 2 each 100.29 200.58
mm long, weighing not less than 88 gms
61 Providing and fixing Stainless Steel A ISI 304 17.10.1.1
(18/8) kitchen sink as per IS: 13983 with C.I.
brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making 2 each 7,506.52 15,013.04
good the walls wherever required : 17.10.1 Kitchen
sink with drain board 17.10.1.1 510x1040 mm bowl
depth 250 mm
62 Providing and laying cement concrete 1:5:10 (1 19.2.2
cement : 5 coarse sand : 10 graded stone aggregate
40 mm nominal size) all-round S.W. pipes including 55 meter 708.34 38,958.70
bed concrete as per standard design : 19.2.2 150 mm
diameter S.W. pipe
63 Providing and fixing on wall face unplasticised 12.41.2
Rigid PVC rain water pipes conforming to IS :
13592 Type A, including jointing with seal ring
12 meter 255.70 3,068.40
conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes. 110
mm diameter
64 Part-C (Sanitary Work) Earth work in excavation 2.8.1
by mechanical means (Hydraulic excavator) /
manual means foundation trenches, drain not
exceeding 1.5 m in width as well as 10 sqm on plan
including dressing of sides and ramming of bottom, 12.8 cum 204.50 2,617.60
lift up to 1.5 m including getting out the excavated
soil and disposal of surplus excavated soil as
directed within a lead of 50 m. (All kinds of
soils).
65 Supplying and filling in plinth with Jamuna sand 2.27
under floors including watering, ramming, 2.76 cum 823.24 2,272.14
consolidation and dressing complete.
66 Providing and laying cement concrete of specified 4.1.8
grade excluding the cost of centering and shuttering
in all works up to plinth level : 1:4:8 (1cement : 2.76 cum 4,182.08 11,542.54
4coarse sand : 8graded stone aggregates 40 mm
nominal size).
67 Brick work with FPS bricks of class designation 50 6.1.2
in foundation and plinth using cement mortar 1:6 8.48 cum 5,537.15 46,955.03
(1cement : 6coarse sand).
68 Brick work with common burnt clay FPS (non- 6.4.2
modular) bricks of class designation 5.0 in super
structure above plinth level up to floor V level in all 20.01 cum 6,546.52 1,30,995.87
shape and size in cement mortar 1:6 (1cement :
6coarse sand).
69 Half brick masonry with FPS bricks of class 6.12.2
designation 50 in foundation and plinth in cement 6.2 sqm 693.61 4,300.38
mortar 1:4 (1cement : 4coarse sand).
70 Providing and laying damp proof course, 40 mm 4.1
thick with cement concrete 1:2:4 (1cement : 2coarse
7.11 sqm 272.90 1,940.32
sand : 4graded stone aggregates 12.5 mm nominal
size).
71 Reinforced cement concrete work in beams 5.3
suspended floors, roofs having slope up to 15
degrees, landings and balconies, chhajjas, shelves,
lintels, bands, plain window sills, staircases and
3.64 cum 7,342.78 26,727.72
spiral staircases up to floor five level excluding the
cost of centering, shuttering, finishing and
reinforcement: 1:2:4 (1cement : 2coarse sand :
4graded stone aggregates 20 mm nominal size).
72 Reinforcement for RCC work including 5.22.6
straightening, cutting, bending, binding and placing
291.59 kg 81.69 23,819.99
in position complete: Thermo Mechanically Treated
bars.
73 Centering and shuttering including strutting, 5.9.3
propping etc. and removal of form for suspended
19.89 sqm 523.45 10,411.42
floors, roofs, landings, balconies and access
platform.
74 Centering and shuttering including strutting, 5.9.5
propping etc. and removal of form for lintels, beams, 8.1 sqm 417.20 3,379.32
plinth beams, girders, bressummers and cantilevers.
75 12mm cement plaster of mix: 1:6 (1cement : 6fine 13.1.2
81.08 sqm 191.77 15,548.71
sand).
76 6mm cement plaster of mix 1:3 (1cement : 3 fine 13.16.1
21.93 sqm 172.36 3,779.85
sand).
77 Providing and laying vitrified floor tiles in different 11.41.2
sizes (thickness to be specified by the manufacture)
with water absorption's less than 0.08% and
conforming to IS:15622 of approved make in all
17.92 sqm 1,202.26 21,544.50
colours and shades, laid on 20mm thick cement
mortar 1:4 (1cement : 4coarse sand) including
grouting the joints with white cement and matching
pigment etc. complete: Size of tile 60x60 cm.
78 Providing and fixing 1st quality ceramic glazed wall 11.36
tiles conforming to IS:15622 (thickness to be
specified by the manufacture) of approved make in
all colour, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-charge
33.625 sqm 910.04 30,600.10
in skirting, risers of steps and dados over 12mm
thick bed of cement mortar 1:3 (1cement : 3coarse
sand) and jointing with grey cement slurry @ 3.3
kg/sqm including pointing in white cement mixed
with pigment of matching shade complete.
79 Finishing wall with water proofing cement paint of 13.44.1
required shade: New work (Two or more coats 64.51 sqm 71.00 4,580.21
applied @ 3.84 kg / 10 sqm).
80 Distempering with oil bound washable distemper of 13.41.1
approved brand and manufacture to give an even
34.02 sqm 118.66 4,036.81
shade: New work (two or more coats) over and
including a priming coat with cement primer.
81 Providing and fixing T-iron frames for doors, 10.13.1
windows and ventilators of mild steel Tee sections
joints mitred welded with 15 x 3 mm lugs, 10 cm
long embedded in cement concrete blocks 15 x 10 x
10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded
stone aggregates 20 mm nominal size) or with 38.04 kg 75.30 2,864.41
wooden plugs and screws or rawl plugs and screws
or with dash fastener or with fixing clips or with
bolts and nuts as required including fixing of
necessary butt hinges and screws and applying a
priming coat of approved steel primer.
82 Providing and fixing 1mm thick M.S. sheet garage 10.5.2
door with frames of 40x40x6mm angle iron, 3mm
M.S. gusset plates at junctions and corners, all 3.6 sqm 3,042.67 10,953.61
necessary fittings complete including applying a
priming coat of approved steel primer: Using M.S.
flats 30x6mm for diagonals and central cross place.
83 Providing and fixing factory made UPVC door 9.117.1
frame made of UPVC extruded section having an
overall dimensions as below (tolerance +/- 1mm)
with wall thickness 2.00mm +/- 0.2mm, corners of
the door frame to be jointed with galvanized
brackets and stainless steel screws joints metred and
plastic welded. The hinge side vertical of the frames 19 metre 205.46 3,903.74
to be reinforced by galvanized MS tube of size
19x19mm and 1mm +/- 0.1mm wall thickness and 3
nos. stainless steel hinges fixed to the frame
complete as per manufacturers specification and
direction of Engineer-in-charge: Extruded section
profile size 48x40mm.
84 Providing and fixing to existing door frames: 30mm 9.118.2
thick factory made Polyvinyl Chloride (PVC) door
shutters made of styles and rails of a UPVC hollow
section of size 60x30mm and wall thickness 2mm
+/- 0.2mm with inbuilt decorative moulding edging
on one side. The styles and rails mitred and jointed
at corners by means of MS galvanized / plastic
brackets of size 75x220mm having wall thickness
1.00mm and stainless steel screws. The styles of
shutter reinforced by insering galvanized MS tube of
size 25x20mm and 1mm +/- 0.1mm wall thickness.
The lock rail made up of H section, a UPVC hollow 5.53 sqm 2,702.07 14,942.45
section of size 100x30mm and 2mm +/- 0.2mm wall
thickness fixed to the shutter styles by means of
plastic / galvanized MS U cleats. The shutter frame
filled with a UPVC muti-chambered single panel of
size not less than 620mm, having overall thickness
of 20mm and 1mm +/- 0.1mm wall thickness. The
panels filled vertically and tie bar at two places by
inserting horizontal 6mm galvanized MS rod and
fastened with nuts and washers, complete as per
manufacturer's specification and direction of
Engineer-in-charge.
85 Filling available excavated earth (excluding rock) in 2.25
trenches, plinth, sides of foundations etc. in layers
not exceeding 20cm in depth, consolidating each 4.27 cum 150.68 643.40
deposited layer by ramming and watering, lead up to
50 m and lift up to 1.5m.
86 Painting with synthetic enamel paint of approved 13.61.1
brand and manufacture to give an even shade: Two 8.64 sqm 87.01 751.77
or more coats on new work.
87 (Water Supply) Providing and placing on terrace 18.48
(at all floor levels) polyethylene water storage tank
ISI:12701 marked with cover and suitable locking
1000 per litre 8.66 8,660.00
arrangement and making necessary holes for inlet,
outlet and overflow pipes but without fittings and
the base support for the tank.
88 Providing and fixing G.I. pipes complete with G.I. 18.10.3
fittings and clamps including cutting and making the
80.07 metre 374.85 30,014.24
walls etc. Internal work - Exposed on wall: 25 mm
nominal bore.
89 Providing and fixing G.I. pipes complete with G.I. 18.10.2
fittings and clamps including cutting and making the
9 metre 316.04 2,844.36
walls etc. Internal work - Exposed on wall: 20 mm
nominal bore.
90 Providing and fixing G.I. pipes complete with G.I. 18.10.1
fittings and clamps including cutting and making the
15 metre 281.87 4,228.05
walls etc. Internal work - Exposed on wall: 15 mm
nominal bore.
91 Providing and fixing PTMT stop cock of approved 18.55.1
quality and colour: 15 mm nominal bore, 86 mm 2 each 100.29 200.58
long weighing not less than 88 gms.
92 Providing and fixing wash basin with C.I. brackets, 17.7.4
15mm C.P. brass pillar taps, 32mm dia. C.P. brass
waste of standard pattern, including painting of
fittings and brackets, cutting and making good the 2 each 2,243.81 4,487.62
walls wherever required: White Vitreous China Flat
back wash basin size 550x400 mm with single
15mm C.P. brass pillar tap.
93 Providing and fixing water closet squatting pan 17.1.1
(Indian type W.C.pan) with 100mm sand cast iron P
or S trap, 10.0 lts. low level P.V.C. flushing cistern
with manually controlled device (handle lever)
conforming to IS:7231, with all fittings and fixtures 2 each 5,184.42 10,368.84
complete including cutting and making good the
walls and floors wherever required: White vitreous
china Orissa pattern W.C. pan of size 580 x 440 mm
with integral type foot rests.
94 Providing and fixing white vitreous china flat back 17.4.2
or wall corner type lipped front urinal basin of
430x260x350 mm and 340x410x265 mm sizes
respectively with automatic flushing cistern with
standard flush pipe and C.P. brass spreaders with
1 each 6,321.02 6,321.02
brass unions and G.I. clamps complete including
painting of fittings and brackets, cutting and making
good the walls and floors wherever required: Rangle
of two urinal basins with 5 litres white P.V.C.
automatic flushing cistern.
95 Providing and fixing one piece construction white 17.6.2
vitreous china squatting plate with an integral
longitudinal flushing pipe, white PVC automatic
flushing cistern, with fittings, satndard size G.I.
flush pipe for back and front flush with standard
spreader pipes with fittings G.I. clamps and CP 1 each 8,411.39 8,411.39
brass coupling complete including painting of
fittings and cutting and making good the walls and
floors etc. wherever required: Range of two
squatting plates with 5 litres PVC automatic flushing
cistern.
96 Providing and fixing mirror of superior glass (of 17.32.2
approved quality) and of required shape and size
with plastic moulded frame of approved make and 2 each 830.71 1,661.42
shape with 6mm thick hard board backing:
Rectangular shape 453x357 mm.
97 Making soak pit 2.5metre diameter, 3metres deep 19.32.1
with 45x45cm dry brick honeycomb shaft with
bricks of class designation 75 and S.W. drain pipe 1 each 23,102.59 23,102.59
100mm diameter, 1.80m long complete as per
standard design with FPS bricks.
98 Providing and fixing single equal junction of 17.44.1.1
required degree: 100x100x100 mm sand cast iron 1 each 530.89 530.89
S&S as per IS:1729.
99 Construction of brick masonry chamber for under 19.30.1.1
ground C.I. inspection chamber and bends with 75
class designation bricks in cement mortar 1:4
(1cement : 4coarse sand) with C.I. cover with frame
(light duty) 455x610mm internal dimensions total
weight of cover and frame to be not less than 38kg
(weight of cover 23kg and weight of frame 15kg).,
R.C.C. top slab with 1:2:4 (1cement : 2coarse sand :
4graded stone aggregates 20mm nominal size), 2 each 4,693.25 9,386.50
foundation concrete 1:5:10 (1cement : 5coarse sand :
10graded stone aggregates 40mm nominal size),
inside plastering 12mm thick with cement mortar
1:3 (1cement : 3coarse sand) finished smooth with a
floating coat of neat cement on walls and bed
concrete etc. complete as per standard design: Inside
dimensions 455x610 mm and 45cm deep single pipe
line with F.P.S. bricks.
100 Providing and fixing heel rest sanitary bend 100 17.40.1
1 each 339.24 339.24
mm sand cast iron S & S as per IS:1729.
101 Providing and fixing terminal guard 100 mm sand 17.56.1.1
1 each 306.72 306.72
cast iron S&S as per IS:1729..
102 Providing and fixing soil, waste and vent pipes: 100 17.35.1.1
1 metre 861.27 861.27
mm dia Sand cast iron S&S as per IS:1729.
103 Providing, laying and jointing glazed stoneware 19.1.1
pipes grade ‘A’ with stiff mixture of cement mortar
in the proportion of 1:1 (1cement : 1fine sand) 10 metre 242.73 2,427.30
including testing of joints etc. complete: 100 mm
diameter.
104 Providing and fixing plain bend of required degree: 17.39.1.1
2 each 419.38 838.76
100 mm Sand cast iron S&S as per IS:1729.
105 Providing and fixing M.S. stays and clamps for sand 17.59.1
cast iron / centrifugally cast (spun) iron pipes of 4 each 68.61 274.44
diameter 100 mm.
106 Providing and fixing bend of required degree with 17.38.1.1
access door, insertion rubber washer 3 mm thick,
2 each 382.21 764.42
bolts and nuts complete: 100 mm Sand cast iron
S&S as per IS:1729.
107 Construction of septic tank 20 users. 1 each 50,607.43 50,607.43 AR
108 PART-D GREEN ROOM & BATHROOM 15.7.4
Demolishing brick work : In cement mortar. 9.17 cum 999.96 9,169.63

109 Dismantling roofing inluding ridges, hips : Asbestos 15.28.2


80.67 sqm 40.81 3,292.14
sheet.
110 Dismantling roofing inluding ridges, hips : G.S 15.28.1
288 sqm 87.99 25,341.12
sheet.
111 E/W excavation in foundation trenches .. .. All kinds 2.8.1
11.69 cum 204.50 2,390.61
of soil.
112 S/F in plinth with river sand under floors .. 0.97 cum 823.24 798.54 2.27
113 P/L CC excluding centering - All work up to plinth 4.1.8
level: 1:4:8 - Coarse sand, 40mmstone aggregate.. .. 0.97 cum 4,182.08 4,056.62

114 B/W with bricks of class 50 in found & plinth in in 6.1.2


7.31 cum 5,537.15 40,476.57
CM 1:6
115 Brick work with FPS bricks of class designation 50 6.4.2
in superstructure above plinth level up to floor V
14.74 cum 6,546.52 96,495.70
level in all shapes and sizes incement mortar 1:6
(1cement : 6coarse sand).
116 Filling available excavated earth (excluding rock) in 2.25
trenches, plinth, sides of foundations etc. in layers
not exceeding 20cm in depth, consolidating each 5.47 cum 150.68 824.22
deposited layer by ramming and watering, lead up to
50 m and lift up to 1.5m.
117 Dry brick on edge flooring in required pattern with 11.2
bricks of class designation 7.5 on a bed of 12 mm
35.03 sqm 638.62 22,370.86
mud mortar, including filling joints with Jamuna
sand, with common burnt clay non modular bricks
118 Cement concrete flooring 1:2:4 (1 cement : 2 coarse 11.3.1
sand : 4 graded stone aggregate) finished with a
floating coat of neat cement, including cement
35.03 sqm 380.32 13,322.61
slurry, but excluding the cost of nosing of steps etc.
complete. 11.3.1 40 mm thick with 20 mm nominal
size stone aggregate
119 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine 13.1.2
125.2 sqm 191.77 24,009.60
sand )
120 Providing and fixing precoated galvanised iron 12.5
profile sheets (size, shape and pitch of corrugation
as approved by Engineer-in-charge) 0.50mm +/- 5%
total coated thickness (TCT) Zinc coating 120gsm as
per IS:277 in 240mpa steel grade, 5-7 microns
epoxy primer on both side of the sheet and polyester
top coat 15-18 microns. Sheet should have protected
guard film of 25 microns minimum to avoid
scratches while transportation and should be
supplied in single length up to 12 metre or as desired
by Engineer-in-charge. The sheet shall be fixed
using self drilling / self tapping screws of size 413.03 sqm 607.00 2,50,709.21
(5.5x55mm) with EPDM seal or with polymer
coated J or L hooks, bolts and nuts 8mm diameter
with bitumen and GI limpet washers or with GI
limpet washers filled with white lead complete upto
any pitch in horizontal / vertical or curved surfaces
excluding the cost of purlins, rafters and trusses and
including cutting to size and shape wherever
required.

121 Providing and fixing ridges and hips in non-asbestos 12.12.2


fibre cement high impact polypropylene reinforced
roofing with suitable fixing accessories or self 24 mtr 348.52 8,364.48
drilling fastener and EPDM washer etc. complete:
Plain wing adjustable ridges.
122 Steel work in riveted, bolted or welded in built up 10.2
sections, trusses and framed work including cutting,
123.2 kg 73.76 9,087.23
hoisting, fixing in position and applying a priming
coat of approved steel primer all complete.
123 Providing and fixing white vitreous china pedestal 17.2.1
type water closet (European type W.C. pan) with
seat and lid, 10 litre low level white P.V.C. flushing
cistern, including flush pipe, with manually
controlled device (handle lever), conforming to IS : 1 each 5,211.13 5,211.13
7231, with all fittings and fixtures complete,
including cutting and making good the walls and
floors wherever required : 17.2.1 W.C. pan with ISI
marked white solid plastic seat and lid
124 Providing and fixing white vitreous china wash 17.25.1
basin including making all connections but
1 each 941.62 941.62
excluding the cost of fittings : 17.25.1 Flat back
wash basin of size 630x450 mm
125 Providing and fixing white vitreous china pedestal 17.3.1
type water closet (European type) with seat and lid,
10 litre low level white vitreous china flushing
cistern & C.P. flush bend with fittings &
C.I.brackets, 40 mm flush bend, overflow
arrangement with specials of standard make and 1 each 6,525.69 6,525.69
mosquito proof coupling of approved municipal
design complete, including painting of fittings and
brackets, cutting and making good the walls and
floors wherever required : 17.3.1 W.C. pan with ISI
marked white solid plastic seat and lid
126 Providing and fixing PTMT towel rail complete with 17.73.1
brackets fixed to wooden cleats with CP brass
screws with concealed fittings arrangement of
approved quality and colour. 17.73.1 450 mm long 1 each 464.50 464.50
towel rail with total length of 495 mm, 78 mm wide
and effective height of 88 mm, weighing not less
than 170 gms
127 Providing and fixing one piece construction white 17.6.1
vitreous china squatting plate with an integral
longitudinal flushing pipe, white P.V.C. automatic
flushing cistern, with fittings, standard size G.I. /
PVC flush pipe for back and front flush with
standard spreader pipes with fittings, G.I clamps and 1 each 5,777.97 5,777.97
C.P. brass coupling complete, including painting of
fittings and cutting and making good the walls and
floors etc. wherever required : 17.6.1 Single
squatting plate with 5 litre P.V.C. automatic flushing
cistern
128 Providing and laying Ceramic glazed floor tiles of 11.37
size 300x300 mm (thickness to be specified by the
manufacturer) of 1st quality conforming to IS :
15622 of approved make in colours such as White,
35.03 sqm 791.23 27,716.79
Ivory, Grey, Fume Red Brown, laid on 20 mm thick
cement mortar 1:4 (1 Cement : 4 Coarse sand),
including pointing the joints with white cement and
matching pigment etc, complete
129 Providing and fixing Ist quality ceramic glazed wall 11.36
tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-
24.91 sqm 910.04 22,669.10
Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white cement
mixed with pigment of matching shade complete.
130 Providing and fixing factory made uPVC door frame 9.117.1
made of uPVC extruded sections having an overall
dimension as below (tolerance ±1mm), with wall
thickness 2.0 mm (± 0.2 mm), corners of the door
frame to be Jointed with galvanized brackets and
stainless steel screws, joints mitred and Plastic
welded. The hinge side vertical of the frames 4.9 meter 205.46 1,006.75
reinforced by galvanized M.S. tube of size 19 X 19
mm and 1mm (± 0.1 mm) wall thickness and 3 nos.
stainless steel hinges fixed to the frame complete as
per manufacturer’s specification and direction of
Engineerin-charge 9.117.1 Extruded section profile
size 48x40 mm
131 Providing and fixing to existing door frames. 30 mm 9.118.2
thick factory made Polyvinyl Chloride (PVC) door
shutter made of styles and rails of a uPVC hollow
section of size 60x30 mm and wall thickness 2 mm
(± 0.2 mm), with inbuilt decorative moulding edging
on one side. The styles and rails mitred and joint at
the corners by means of M.S. galvanised/ plastic
brackets of size 75x220 mm having wall thickness
1.0 mm and stainless steel screws. The styles of the
shutter reinforced by inserting galvanised M.S. tube
of size 25x20 mm and 1 mm (± 0.1 mm) wall
thickness. The lock rail made up of ‘H’ section, a 1.74 sqm 2,702.07 4,701.60
uPVC hollow section of size 100x30 mm and 2 mm
(± 0.2 mm) wall thickness fixed to the shutter styles
by means of plastic/ galvanised M.S. ‘U’ cleats. The
shutter frame filled with a uPVC multi-chambered
single panel of size not less than 620 mm, having
over all thickness of 20 mm and 1 mm (± 0.1 mm)
wall thickness . The panels filled vertically and tie
bar at two places by inserting horizontally 6 mm
galvanised M.S. rod and fastened with nuts and
washers, complete as per manufacturer’s
specification and direction of Engineer-in-charge.
132 Providing and applying white cement based putty of 13.8
average thickness 1 mm, of approved brand and
144.8 sqm 103.63 15,005.62
manufacturer, over the plastered wall surface to
prepare the surface even and smooth complete
133 Distempering with oil bound washable distemper of 13.41.1
approved brand and manufacture to give an even
shade : 13.41.1 New work (two or more coats) over 144.8 sqm 118.66 17,181.97
and including water tinnable priming coat with
cement primer
134 Providing and fixing false ceiling at all height 12.45.1
including providing and fixing of frame work made
of special sections, power pressed from M.S. sheets
and galvanized with zinc coating of 120 gms/sqm
(both side inclusive) as per IS : 277 and consisting
of angle cleats of size 25 mm wide x 1.6 mm thick
with flanges of 27 mm and 37mm, at 1200 mm
centre to centre, one flange fixed to the ceiling with
dash fastener 12.5 mm dia x 50mm long with 6mm
dia bolts, other flange of cleat fixed to the angle
hangers of 25x10x0.50 mm of required length with
nuts & bolts of required size and other end of angle
hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200 mm
centre to centre, to which the ceiling section 0.5 mm
thick bottom wedge of 80 mm with tapered flanges
131.03 sqm 892.53 1,16,948.21
of 26 mm each having lips of 10.5 mm, at 450 mm
centre to centre, shall be fixed in a direction
perpendicular to G.I. intermediate channel with
connecting clips made out of 2.64 mm dia x 230 mm
long G.I. wire at every junction, including fixing
perimeter channels 0.5 mm thick 27 mm high having
flanges of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl
plugs at 450 mm centre, with 25mm long dry wall
screws @ 230 mm interval, including fixing of
gypsum board to ceiling section and perimeter
channel with the help of dry wall screws of size 3.5
x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square
edges of the board with recomme-nded jointing
compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on
both sides of joint and two coats of primer suitable
for board, all as per manufacturer’s specification and
also including the cost of making openings for light
fittings, grills, diffusers, cutouts made with frame of
perimeter channels suitably fixed, all complete as
per drawings, specification and direction of the
Engineer in Charge but excluding the cost of
painting with : 12.45.1 12.5 mm thick tapered edge
gypsum plain board conforming to IS: 2095- Part I
135 Wall painting with acrylic emulsion paint of 13.60.1
approved brand and manufacture to give an even 131.03 sqm 98.41 12,894.66
shade : 13.60.1 Two or more coats on new work
136 Providing and fixing PTMT bib cock of approved 18.54.1
quality and colour. 18.54.1 15mm nominal bore, 86 1 each 100.29 100.29
mm long, weighing not less than 88 gms
137 Providing and fixing on wall face unplasticised 12.41.2
Rigid PVC rain water pipes conforming to IS :
13592 Type A, including jointing with seal ring
6 meter 255.70 1,534.20
conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes. 110
mm diameter
138 Construction of septic tank 20 users 1 each 50,869.91 50,869.91 AR
139 Providing and fixing Chlorinated Polyvinyl 18.9.1
Chloride (CPVC) pipes, having thermal stability for
hot & cold water supply including all CPVC plain &
brass threaded fittings This includes jointing of
15 meter 172.47 2,587.05
pipes & fittings with one step CPVC solvent cement
,trenching ,refilling & testing of joints complete as
per direction of Engineer in Charge. External work
18.9.1 15 mm nominal outer dia Pipes
Total cost excluding GST Rs. 37,76,454.62
GST @18% 6,79,761.83
Total cost including GST Rs. 44,56,216.45

You might also like