S.N Description of work Qty. Unit AR Amount Remarks
1 PART-A "Dining Room" Earth work in excavation CPWD-
by mechanical means (Hydraulic excavator) / 2014
manual means in foundation trenches or drains (not revised rate
exceeding 1.5 m in width or 10 sqm on plan), 2.8.1 2014
including dressing of sides and ramming of bottoms, 48.77 cum 204.50 9,973.47 updation
lift upto 1.5 m, including getting out the excavated rate of
soil and disposal of surplus excavated soil as 2020
directed, within a lead of 50 m. 2.8.1 All kinds of
soil.
2 Providing and laying in position cement concrete of 4.1.8
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :1:4:8 (1 29.50 cum 4,182.08 1,23,388.57
Cement : 4 coarse sand : 8 graded stone aggregate
40 mm nominal size)
3 Providing and laying in position specified grade of 5.1.2
reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement -
8.12 cum 5,935.93 48,199.75
All work up to plinth level : 1:1.5:3 (1 cement : 1.5
coarse sand : 3 graded stone aggregate 20 mm
nominal size
4 Reinforced cement concrete work in walls (any 5.2.2
thickness), including attached pilasters, buttresses,
plinth and string courses, fillets, columns, pillars,
piers, abutments, posts and struts etc. up to floor five
9.21 cum 7,030.17 64,747.87
level, excluding cost of centering, shuttering,
finishing and reinforcement :1:1.5:3 (1 cement : 1.5
coarse sand : 3 graded stone aggregate
20 mm nominal size)
5 Steel reinforcement for R.C.C. work including 5.22.6
straightening, cutting, bending, placing in position
812 kg 81.69 66,332.28
and binding all complete upto plinth level. Thermo-
Mechanically Treated bars
6 Steel reinforcement for R.C.C. work including 5.22A.6
straightening, cutting, bending, placing in position
828.9 kg 81.69 67,712.84
and binding all complete above plinth level.
Thermo-Mechanically Treated bars
7 Centering and shuttering including strutting, 5.9.1
propping etc. and removal of form for : 5.9.1
40.5 sqm 228.07 9,236.84
Foundations, footings, bases of columns, etc. for
mass concrete
8 Centering and shuttering including strutting, 5.9.6
propping etc. and removal of form for : Columns, 76.15 sqm 575.98 43,860.88
Pillars, Piers, Abutments, Posts and Struts
9 Centering and shuttering including strutting, 5.9.5
propping etc. and removal of form for : Lintels,
19.6 sqm 417.20 8,177.12
beams, plinth beams, girders, bressumers and
cantilevers
10 Centering and shuttering including strutting, 5.9.3
propping etc. and removal of form for : Suspended
4.31 sqm 523.45 2,256.07
floors, roofs, landings, balconies and access
platform
11 Supply of good quality stone dust. Item Code
1159,
78.4 cum 1,265.00 99,176.00
CPWD
2014
12 Supplying and filling in plinth with Jamuna sand 2.27
under floors, including watering, ramming, 16.8 cum 823.24 13,830.43
consolidating and dressing complete.
13 Providing and laying vitrified floor tiles in different 11.41.2
sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and
conforming to IS : 15622, of approved make, in all
colours and shades, laid on 20mm thick cement 128 sqm 1,202.26 1,53,889.28
mortar 1:4 (1 cement : 4 coarse sand), including
grouting the joints with white cement and matching
pigments etc., complete. Size of Tile 600x600 mm
14 Providing and fixing Ist quality ceramic glazed wall 11.36
tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make,
in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-
13.68 sqm 910.04 12,449.35
Charge, in skirting, risers of steps and dados, over
12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white cement
mixed with pigment of matching shade complete.
15 Brick work with common burnt clay F.P.S. (non 6.1.2
modular) bricks of class designation 7.5 in
22.45 cum 5,537.15 1,24,309.02
foundation and plinth in: Cement mortar 1:6 (1
cement : 6 coarse sand)
16 Providing and laying damp-proof course 40 mm 4.1
thick with cement concrete 1:2:4 (1 cement : 2
11.18 sqm 272.90 3,051.02
coarse sand : 4 graded stone aggregate 12.5 mm
nominal size).
17 Brick work with common burnt clay F.P.S. (non 6.4.2
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level 51.62 sqm 6,546.52 3,37,931.36
in all shapes and sizes in : Cement mortar 1:6 (1
cement : 6 coarse sand)
18 Providing and fixing T-iron frames for doors, 10.13.1
windows and ventilators of mild steel Tee-sections,
joints mitred and welded, including fixing of
necessary butt hinges and screws and applying a
priming coat of approved steel primer. 10.13.1 37.8 kg 75.30 2,846.34
Fixing with 15x3 mm lugs 10 cm long embedded in
cement concrete block 15x10x10 cm of C.C. 1:3:6
(1 Cement : 3 coarse sand : 6 graded stone aggregate
20 mm nominal size)
19 Providing and fixing ISI marked flush door shutters 9.21.2
conforming to IS : 2202 (Part I) non-decorative type,
core of block board construction with frame of 1st
class hard wood and well matched commercial 3 ply
4.91 sqm 1,590.67 7,810.19
veneering with vertical grains or cross bands and
face veneers on both faces of shutters: 30 mm thick
including ISI marked Stainless Steel butt hinges
with necessary screws
20 Providing and fixing aluminium work for doors, 21.1.2.1
windows, ventilators and partitions with extruded
built up standard tubular sections/ appropriate Z
sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with
dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/
neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat
angle, Aluminium snap beading for glazing /
10.8 meter 430.99 4,654.69
paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing, paneling
and dash fasteners to be paid for separately) : For
shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making
provision for fixing of fittings wherever required
including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent
or dyed to required shade according to IS: 1868,
Minimum anodic coating of grade AC 15
21 Providing and fixing glazing in aluminium door, 21.3.3
window, ventilator shutters and partitions etc. with
EPDM rubber / neoprene gasket etc. complete as
per the architectural drawings and the directions of 3.6 sqm 786.46 2,831.26
engineer-in-charge. (Cost of aluminium snap
beading shall be paid in basic item): With float
glass panes of 8 mm thickness
22 Providing and fixing M.S. grills of required pattern 9.48.1
in frames of windows etc. with M.S. flats, square or
round bars etc. including priming coat with 54 kg 144.96 7,827.84
approved steel primer all complete. 9.48.1 Fixed to
steel windows by welding
23 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine 13.1.2
374.22 sqm 191.77 71,764.17
sand
24 Providing and applying white cement based putty of 13.8
average thickness 1 mm, of approved brand and
167.76 sqm 103.63 17,384.97
manufacturer, over the plastered wall surface to
prepare the surface even and smooth complete
25 Making plinth protection 50 mm thick of cement 4.17
concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded
stone aggregate 20 mm nominal size) over 75mm
49.8 meter 464.75 23,144.55
thick bed of dry brick ballast 40 mm nominal size,
well rammed and consolidated and grouted with fine
sand, including finishing the top smooth.
26 Distempering with oil bound washable distemper of 13.41.1
approved brand and manufacture to give an even
shade : 13.41.1 New work (two or more coats) over 167.76 sqm 118.66 19,906.40
and including water tinnable priming coat with
cement primer
27 Finishing walls with water proofing cement paint of 13.44.1
required shade : 13.44.1 New work (Two or more 193.26 sqm 71.00 13,721.46
coats applied @ 3.84 kg/10 sqm
28 Painting with synthetic enamel paint of approved 13.61.1
brand and manufacture to give an even shade : 4.68 sqm 87.01 407.21
13.61.1 Two or more coats on new work
29 Providing and fixing false ceiling at all height 12.45.1
including providing and fixing of frame work made
of special sections, power pressed from M.S. sheets
and galvanized with zinc coating of 120 gms/sqm
(both side inclusive) as per IS : 277 and consisting
of angle cleats of size 25 mm wide x 1.6 mm thick
with flanges of 27 mm and 37mm, at 1200 mm
centre to centre, one flange fixed to the ceiling with
dash fastener 12.5 mm dia x 50mm long with 6mm
dia bolts, other flange of cleat fixed to the angle
hangers of 25x10x0.50 mm of required length with
nuts & bolts of required size and other end of angle
hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200 mm
centre to centre, to which the ceiling section 0.5 mm
thick bottom wedge of 80 mm with tapered flanges
of 26 mm each having lips of 10.5 mm, at 450 mm
centre to centre, shall be fixed in a direction
perpendicular to G.I. intermediate channel with
connecting clips made out of 2.64 mm dia x 230 mm
long G.I. wire at every junction, including fixing
128 sqm 892.53 1,14,243.84
perimeter channels 0.5 mm thick 27 mm high having
flanges of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl
plugs at 450 mm centre, with 25mm long dry wall
screws @ 230 mm interval, including fixing of
gypsum board to ceiling section and perimeter
channel with the help of dry wall screws of size 3.5
x 25 mm at 230 mm c/c, including jointing and
finishing to a flush finish of tapered and square
edges of the board with recomme-nded jointing
compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on
both sides of joint and two coats of primer suitable
for board, all as per manufacturer’s specification and
also including the cost of making openings for light
fittings, grills, diffusers, cutouts made with frame of
perimeter channels suitably fixed, all complete as
per drawings, specification and direction of the
Engineer in Charge but excluding the cost of
painting with 12.5 mm thick tapered edge gypsum
plain board conforming to IS: 2095- Part I
30 Wall painting with acrylic emulsion paint of 13.60.1
approved brand and manufacture to give an even 128 sqm 98.41 12,596.48
shade : 13.60.1 Two or more coats on new work
31 Extra for providing and fixing wind ties of 40x 6 12.11
224 meter 116.59 26,116.16
mm flat iron section.
32 Providing and fixing ridges and hips in fibre cement 12.12.2
high impact polypropylene reinforced roofing with
16 meter 348.52 5,576.32
suitable fixing accessories or self drilling fastener
and EPDM washer etc. complete.
33 Providing and fixing precoated galvanised iron 12.5
profile sheets (size, shape and pitch of corrugation
as approved by Engineer-in-charge) 0.50 mm (+
0.05 %) total coated thickness with zinc coating 120
grams per sqm as per IS: 277, in 240 mpa steel
grade, 5-7 microns epoxy primer on both side of the
sheet and polyester top coat 15-18 microns. Sheet 166.72 sqm 607.00 1,01,199.04
should have protective guard film of 25 microns
minimum to avoid scratches during transportation
and should be supplied in single length upto 12
metre or as desired by Engineerin-charge. The sheet
shall be fixed using self drilling / self tapping screws
of size (5.5x 55 mm) with EPDM seal, complete
upto any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters and
trusses and including cutting to size and shape
wherever required.
34 Structural steel work riveted, bolted or welded in 10.2
built up sections, trusses and framed work, including
3638.15 kg 73.76 2,68,349.94
cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer all complete.
35 PART-B "Kitchen Room" Earth work in 2.8.1
excavation by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or
drains (not exceeding 1.5 m in width or 10 sqm on
plan), including dressing of sides and ramming of 20.25 cum 204.50 4,141.13
bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil
as directed, within a lead of 50 m. 2.8.1 All kinds of
soil
36 Providing and laying in position cement concrete of 4.1.8
specified grade excluding the cost of centering and
shuttering - All work up to plinth level : 1:4:8 (1 6.98 cum 4,182.08 29,190.92
Cement : 4 coarse sand : 8 graded stone aggregate
40 mm nominal size)
37 Brick work with common burnt clay F.P.S. (non 6.1.2
modular) bricks of class designation 7.5 in
12.19 cum 5,537.15 67,497.86
foundation and plinth in: Cement mortar 1:6 (1
cement : 6 coarse sand)
38 Brick work with common burnt clay F.P.S. (non 6.4.2
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level 14.75 cum 6,546.52 96,561.17
in all shapes and sizes in : Cement mortar 1:6 (1
cement : 6 coarse sand)
39 Providing and fixing M.S. grills of required pattern 9.48.1
in frames of windows etc. with M.S. flats, square or
round bars etc. including priming coat with 410.63 kg 144.96 59,524.92
approved steel primer all complete. 9.48.1 Fixed to
steel windows by welding
40 Reinforced cement concrete work in beams, 5.3
suspended floors, roofs having slope up to 15°
landings, balconies, shelves, chajjas, lintels, bands,
plain window sills, staircases and spiral stair cases
3.4 cum 7,342.78 24,965.45
up to floor five level, excluding the cost of
centering, shuttering, finishing and reinforcement,
with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size).
41 Steel reinforcement for R.C.C. work including 5.22.6
straightening, cutting, bending, placing in position
272.24 kg 81.69 22,239.29
and binding all complete upto plinth level. Thermo-
Mechanically Treated bars
42 Centering and shuttering including strutting, 5.9.6
propping etc. and removal of form for : Columns, 7.5 sqm 575.98 4,319.85
Pillars, Piers, Abutments, Posts and Struts
43 Centering and shuttering including strutting, 5.9.5
propping etc. and removal of form for : Lintels,
7.5 sqm 417.20 3,129.00
beams, plinth beams, girders, bressumers and
cantilevers
44 Centering and shuttering including strutting, 5.9.3
propping etc. and removal of form for : Suspended
12.63 sqm 523.45 6,611.17
floors, roofs, landings, balconies and access
platform
45 Supplying and filling in plinth with Jamuna sand 2.27
under floors, including watering, ramming, 7.2 cum 823.24 5,927.33
consolidating and dressing complete.
46 Dry brick on edge flooring in required pattern with 11.2
bricks of class designation 7.5 on a bed of 12 mm
36 sqm 638.62 22,990.32
mud mortar, including filling joints with Jamuna
sand, with common burnt clay non modular bricks.
47 Cement concrete flooring 1:2:4 (1 cement : 2 coarse 11.3.1
sand : 4 graded stone aggregate) finished with a
floating coat of neat cement, including cement
36 sqm 380.32 13,691.52
slurry, but excluding the cost of nosing of steps etc.
complete. 11.3.1 40 mm thick with 20 mm nominal
size stone aggregate
48 12 mm cement plaster finished with a floating coat 13.7.2
45.68 sqm 254.17 11,610.49
of neat cement of mix : 1:4 (1 cement: 4 fine sand
49 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine 13.1.2
134.76 sqm 191.77 25,842.93
sand
50 6 mm cement plaster of mix : 13.16.1 1:3 (1 cement 13.16.1
23.22 sqm 172.36 4,002.20
: 3 fine sand)
51 Providing and fixing precoated galvanised iron 12.5
profile sheets (size, shape and pitch of corrugation
as approved by Engineer-in-charge) 0.50 mm (+
0.05 %) total coated thickness with zinc coating 120
grams per sqm as per IS: 277, in 240 mpa steel
grade, 5-7 microns epoxy primer on both side of the
sheet and polyester top coat 15-18 microns. Sheet
should have protective guard film of 25 microns
minimum to avoid scratches during transportation 45.54 sqm 607.00 27,642.78
and should be supplied in single length upto 12
metre or as desired by Engineerin-charge. The sheet
shall be fixed using self drilling / self tapping screws
of size (5.5x 55 mm) with EPDM seal, complete
upto any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters and
trusses and including cutting to size and shape
wherever required.
52 Structural steel work riveted, bolted or welded in 10.2
built up sections, trusses and framed work, including
144 kg 73.76 10,621.44
cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer all complete.
53 Extra for providing and fixing wind ties of 40x 6 12.11
48 meter 116.59 5,596.32
mm flat iron section.
54 Providing and fixing M.S. fan clamp type I or II of 10.17
16 mm dia M.S. bar, bent to shape with hooked ends
in R.C.C. slabs or beams during laying, including 2 each 164.27 328.54
painting the exposed portion of loop, all as per
standard design complete.
55 White washing with lime to give an even shade : 13.37.1
13.37.1 New work (three or more coats) 46.95 sqm 20.52 963.41