4 Wallfooting Details: B A B A

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PROJECT TITLE:

NOTE:
1. ALL STRUCTURAL POSITIONING
ARE ALL TO BE VERIFIED TO 6"THK CHB W/12mm.
VERT & HOR. @ 0.60m.
MATCH EXISTING AND SUBJECT WALL REINFORCEMENT (TYPICAL) o.c.
FOR ENGINEER'S ADVICE;
2. TOILET SLAB SHALL BE
PROVIDED WITH HOLE TO
HOUSE THE PIPE WITHOUT
A B A B
CHANGING ELEVATION
3. GUARD RAILS ARE TO PROVIDE
WITH DECORATIVE PRECAST DOWEL BARS TO MATCH A PROPOSED TWO (2) STOREY ONE
CONCRETE; and CHB VERTICAL BARS
4.70 4.70 (1) BEDROOM GUEST HOUSE
4. ALL COMPONENTS ARE
ASSUMED. LOCATION: -
3-12mm. CONT. BARS
OWNER:
1.00 3.70 1.00 3.70
FLOOR BEAM EXSTNG SLAB
CONCRETE BLOCK
1.00

1.00
CS OWNER'S NAME
1 FLOOR BEAM ROOF BEAM 02
CHIPPED SURFACE
TO BETTER ADHESION
FIN. FLR. LEVEL

DESIGNED BY:

0.40

ROOF BEAM 02

ROOF BEAM 02
WALLFOOTING DETAILS
FLOOR BEAM

FLOOR BEAM
7.00

7.00
CS
TWO
WAY 4
6.00

6.00
SCALE nts CIVIL ENGINEER
SLAB I CERTIFY THAT THIS DRAWING WAS PREPARED BY
ROOF ASSEMBLY ME OR UNDER MY DIRECT SUPERVISION.
CONTACT NO.
FACEBOOK: fb.com/johnnielvenepis
13.00

13.00

FLOOR BEAM 200mm


2 ROOF BEAM 02
R.A 9266

ROOF BEAM 02

ROOF BEAM 02
FLOOR BEAM

FLOOR BEAM

DRAWINGS AND COPIES THEREOF AS INSTRUMENT OF SERVICE


TWO TWO ARE THE PROPERTY OF THE ARCHITECT. WORK FOR WHICH
CS
3.12

3.12
WAY WAY THEY ARE MADE MAY BE EXECUTED OR NOT AND ARE NOT TO
SLAB SLAB BE REPRODUCED OR USED IN OTHER WORK EXCEPT BY

300mm
WRITTEN AGREEMENT WITH THE ARCHITECT.

FLOOR BEAM NOTE:

3 ROOF BEAM 02 ALL MEASUREMENTS MUST BE VERIFIED AT THE SITE


BEFORE CONSTRUCTION. CONTRACTORS SHALL NOTIFY THE
FLOOR BEAM

FLOOR BEAM

ARCHITECT/ DESIGNER OF ANY DISCREPANCY BEFORE


TWO COMMENCEMENT OF WORK. JNDEA ARCHITECTURAL WORKS
2.88

2.88
CS WAY SHALL NOT BE HELD RESPONSIBLE FOR ANY ERRORS
SLAB SHOULD THE CONTRACTORS FAIL TO OBSERVE THIS
PROCEDURE. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY ERRORS RESULTING FROM FAILURE TO DO SO.
FLOOR BEAM
(C1) SHEET CONTENT:

Main Rebars:
4-16mm.Ø RSB
4.70 4.70 Ties: Single Tie Set
10mm.Ø Ties:
4 @ .10m. & rest @ 0.20m.

NOTE:
REINFORCEMENT DESIGN NOTE:
1. ALL EXISTING STRUCTURAL COMPONENTS ARE SUBJECT DO NOT SCALE DRAWINGS, ALL FIGURED DIMENSIONS ARE
TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION
FOR ENGINEERS ACCEPTANCE & EVALUATION; and
WITH THE GENERAL ARCHITECTURAL WORKING DRAWINGS,
2. ALL INDICATED SIZE ON THE PLAN ARE ALL ASSUMED TO STRUCTURAL, SANITARY, ELECTRICAL AND MECHANICAL
BE ON STANDARDS. PLANS AND OTHER RELATED DRAWINGS. ANY DISCREPANCY
FOUND SHALL BE NOTIFIED TO THE ARCHITECT
IMMEDIATELY.
SECOND FLOOR LEVEL ROOF LEVEL

BEAM FRAMING PLAN BEAM FRAMING PLAN COLUMN SCHEDULE DRAWN BY: SHEET NO:

1 SCALE 1:100 mts 2 SCALE 1:100 mts


3 SCALE nts
DATE:
CHECKED BY:
1
DATE: OF: 2
PROJECT TRACK I.D.:
STRUCTURAL