Ground Floor Plumbing Layout Second Floor Plumbing Layout

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

REPUBLIC OF THE PHILIPPINES

PLUMBING ANALYSIS: DEPARTMENT OF PUBLIC


WORKS AND HIGHWAYS
OFFICE OF THE BUILDING OFFICIAL
SS SS 1. DESIGN OF SEPTIC TANK

KS
FIXTURE UNITS FU LOAD 4. WATERLINE REQUIREMENT

4"Ø Soil Pipe


2"Ø Vent Pipe
WC 2 6 12 NO. OF OCCUPANT- 8 PERSONS
V WATER RQUIRED - 8 (135 lpd) = 1080 lpd = 288 gpd
V LAV 2 2 2
SIZE OF WATER TANK
slide

FCO
SH
4"Ø Soil Pipe

BD
FD 2 2 4
SD
BT
SHO 2 2 2 ASSUME ONE DAY POWER OUTAGE
PAVIA

4"Ø Soil Pipe


WT = 288 gpd x 2DAYS = 576 gal.
SINK 3 2 6

slide
5 4 3 2 1 6 5 4 3 2 1
SAY 500 gal. cap. CITY / MUNICIPALITY
UP
7
WC BIDET 2 2 4

slide

4"Ø Soil Pipe


FD
FD
SD 8
LAV LAV 5. SIZING OF DOWN SPOUT & ROOF DRAIN PLUMBING
DRAINAGE FU = 30

DN
SH FCO V V
9 10 11 12 13 14 15 16 17 18 19 ROOF AREA 130 sq.m
Septic ASSUME RAINFALL INTENSITY - 10"/hr
Vault FROM TABLE B - 2
ROOF COVERAGE: 75m DS = 81 sq.m

slide
SEPTIC TANK CAP 4544 LITERS OR 4.5 CU.M.
75m RD = 43 sq.m
FROM TABLE

slide
slide

DIMENSION OF SEPTIC TANK (DIGESTIVE CHAMBER) NO. OF DS - 130 / 81 = 1.60


NO. OF RD - 130 / 43 = 3.02
slide

D - 1.20 M, W - 1.25M, L - 2.50 M


ADD 1.0M FOR LEACHING CHAMBER THERFORE: PROVIDE: 2 OR MORE 75mm DS
4 OR MORE 75mm RD
4"Ø Drain Pipe

slide slide
slide slide

2. SIZING OF SEWER LINE


TO DRAIN FIELD FU - 30 6. PUMP HORSE POWER REQUIREMENT
VOLUME OF WATERTANK = 500 gals
FROM TABLE USE 4" DIA PIPE
USE 50mm DIA (2") SOIL PIPE FOR FD, LAV, VENT & KS FILLING TIME = 1hr
GPM = 500 gals/80 = 8.33 gpm LEGEND
3. SIZING OF WATER LINE TDH = 15 FT; PUMP EFF = 60%
WATER LINE
wsfu-WC( 2 )(6)+LAV( 2)(2)+SHO( 2 )(2)+KS(3)(2)+BD(2)(2)
PUMP HP = 8.31 gpm x 15 ft = 0.08 DRAINAGE
= 30 wsfu
FROM TABLE 1.2; DEMAND GPM - 29.1 gpm 3960 x 60%
TO EXISTING

VENT
SEWER LINE

FROM TABLE 1.4; ADD 5 gpm FOR HOSE BIBB WC WATER CLOSET
TOTAL gpm = 34.1 THERFORE: PROVIDE:
FIGURE 3: FOR A FLOW 29.1 gpm & VEL. OF 10 fps one ( 1 ) UNIT 1 hp ELECTRIC WATER PUMP BD BIDET
USE 1" DIA. CWL MAIN WATERLINE CAP = 8.33 GPM 15 ft TDH LAV LAVATORY
FD FLOOR DRAIN
A GROUND FLOOR PLUMBING LAYOUT B SECOND FLOOR PLUMBING LAYOUT WATERLINE FOR UNIT CR
P01 P01 wfsu - WC (1)(6) + LAV (1)(2) + SHO (1)(2) + BD (1)(2) SHO SHOWER
= 12 wfsu VTR VENT THRU ROOF
FROM TABLE 1.2; DEMAND GPM - 14.6 CO CLEAN OUT
KS
FIGURE 2; USE 12" DIA. CWL PER CR HB HOSE BIB
WC FAU FROM SEC 202 USE WATERLINE TO FIXTURE AS FOLLOWS:
90 deg ELBOW

38
FAU WC - 38"; LAV - "; KS - 12"; SHO - 12" 10 MM Ф RSB
LAV
ELBOW
TO UPPER TO LOWER
GROUND LEVEL GROUND LEVEL
slide

GV
SH
15mmØ CWL
PPR PIPE
WYE
SH SH

BATH
TUB
BT

500
SD
S.D. GV P-TRAP
20mmØ CWL PPR PIPE
slide

WC 5 4 3 2 1 6 5 4 3 2 1
CLEAN OUT
WC
UP 7 W.C.
WM WATER METER
slide

15mmØ CWL
LAV

PPR PIPE
F.D. F.D.
FAU 8
SD LAV LAV
LAV. LAV.

DN
SH
SH BT slide
slide
9 10 11 12 13 14 15 16 17 18 19
FAU FAU
500
slide

CATCH BASIN
slide

slide slide
slide slide
20mmØ CWL PPR PIPE

3500
3500

300 100
100MM THK CONC. SLAB 1500 1000 1000

300
CV UP w/ 12MM�� BARS SP @ AIR SPACE AIR SPACE AIR SPACE
OUTLET
550 550 550 INLET
UP
WM

GV 0.15 O.C B.W


TO LOCAL
WATER DISTRICT

1800

1200
LEACHING LEACHING
OUTLET OUTLET DIGESTION CHAMBER CHAMBER CHAMBER

1200
MANHOLE MANHOLE MANHOLE

GROUND FLOOR WATER SYSTEM LAYOUT D SECOND FLOOR WATER SYSTEM LAYOUT

200
C
P01 P01

INLET
SECTION
PLAN
SEPTIC VAULT DETAIL

CERTIFIED BY: REPUBLIC ACT 9266 PROJECT TITLE : OWNER : SHEET CONTENTS : SHEET NO. :

Ar. PRUSSIAN BLEAU C. ARCEO Engr. PERCIVAL M. GAVIETA


This drawing is an nstrument of service, is a property of AR.
ARCHITECT UAP SANITARY ENGINEER / MASTER PLUMBER PRUSSIAN BLEAU C. ARCEO, registered architect and such as
must not be reproduced or copied in part or in whole without his PROPOSED TWO-STOREY
C:\Users\user-pc\Documents\ALPPA ARCHITECTS\LOGO\ALPPA NEW LOGO FULL.jpg
PTR NO.

DATE ISSUED:
PRC NO.

TIN:
PTR NO.

DATE ISSUED :
PRC NO.

TIN :
permission, all drawings are to be returned when no longer in use.

PRESIDENTIAL DECREE NO. 49


RESIDENCE
AS SHOWN P
PLACE ISSUED: IAPOA NO: PLACE ISSUED:
" Protection of intellectual Property" works of art,
Architecture,Models and designs are creative works and
considered as part of intellectual property of the author.
LOCATION : BRGY. UNGKA II, PAVIA, ILOILO CADD BY : ALLPA DATE CADD : JULY 2022
1