Professional Documents
Culture Documents
Example 1: Two-Way Solid Slab With Beams
Example 1: Two-Way Solid Slab With Beams
Given:
Solution:
Slab thickness:
𝑓𝑓𝑦𝑦 420
𝑙𝑙𝑛𝑛 �0.8 + 1400� 7.1 �0.8 + �
ℎ= = 1400 = 0.165𝑚𝑚 ≥ 0.09𝑚𝑚 𝑜𝑜𝑜𝑜
36 + 9𝛽𝛽 36 + 9(1.273)
178
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
The moments of inertias are calculated for the two sections, they are:
179
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
Since all values of 𝛼𝛼𝑓𝑓 are greater than 2.0, the average of any four values shall be not less
than 2.0. So, 𝛼𝛼𝑓𝑓𝑓𝑓 for each panel is greater than 2.0.
Check wide beam shear (one-way shear): for stiff beams, the shear can be calculated
considering the short direction of the largest panel. Here, the short span, L= 6.0m.
𝐿𝐿 𝑏𝑏1 6 0.4
𝑉𝑉𝑢𝑢 = 𝑊𝑊𝑢𝑢 � − − 𝑑𝑑� = 18.8 � − − 0.16� = 49.6𝑘𝑘𝑘𝑘
2 2 2 2
1
1 0.75 � � (1)√24(1000)(160)
𝑨𝑨𝑨𝑨𝑨𝑨 𝟑𝟑𝟑𝟑𝟑𝟑 − 𝟏𝟏𝟏𝟏: ∅𝑉𝑉𝑐𝑐 = ∅ 𝜆𝜆�𝑓𝑓′𝑐𝑐 𝑏𝑏𝑤𝑤 𝑑𝑑 = 6 = 98𝑘𝑘𝑘𝑘
6 1000
> 49.6𝑘𝑘𝑘𝑘 𝑜𝑜𝑜𝑜
1 𝑁𝑁𝑢𝑢
∅𝑉𝑉𝑐𝑐 = ∅ �0.66𝜆𝜆𝑠𝑠 𝜆𝜆(𝜌𝜌𝑤𝑤 )3 �𝑓𝑓 ′ 𝑐𝑐 + � 𝑏𝑏 𝑑𝑑
6𝐴𝐴𝑔𝑔 𝑤𝑤
1
0.75 �0.66(1)(1)(0.00225)3 √24 + 0.0� (1000)(160)
= = 50.85𝑘𝑘𝑘𝑘
1000
> 49.6𝑘𝑘𝑘𝑘 𝑂𝑂𝑂𝑂
180
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
1. Compute the total statical moment, Mo for each span. Here the three spans are equal.
𝐿𝐿2 6
= = 0.8
𝐿𝐿1 7.5
From ACI 318-14 Table 8.10.5.5, for positive moment, the ratio = 81%
From ACI 318-14 Table 8.10.5.1, for interior negative moment, the ratio = 81%
181
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
Ecb C 𝐶𝐶 8.155(10)−3
βt = = = = 1.02
2Ecs Is 2𝐼𝐼𝑠𝑠 2( 1 )(6)(0.2)3
12
𝐿𝐿2 6
= = 0.8
𝐿𝐿1 7.5
From ACI 318-14 Table 8.10.5.2, for exterior negative moment, the ratio = 92%
𝛼𝛼𝑓𝑓 𝐿𝐿2
Since > 1.0, 0.85 of column strip moments are transferred to the beams.
𝐿𝐿1
Figure 8.30 below shows the bending moment diagram of the beam in frame 2.
182
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
The beam section is shown above, so the steel area can be computed.
The slab column strip moment = the column strip moment – the beam moment
The slab middle strip moment = the frame moment – the column strip moment.
183
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
Figure 8.33: Free body diagram for the exterior span in beam in frame 2
The shear values at left and right ends of span are computed as follows:
184
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
For the interior span, the end moments are equal, so they can be cancelled, then:
1.5 7
𝑉𝑉𝑢𝑢𝑢𝑢 = 𝑉𝑉𝑢𝑢𝑢𝑢 = 112.8(2.75)(0.50) + � � 112.8 + � � (4.8) = 256.5𝑘𝑘𝑘𝑘
2 2
Given:
185
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
Solution:
Slab loads:
𝑑𝑑
𝑏𝑏1 = 𝑐𝑐1 + = 0.59𝑚𝑚 𝑏𝑏2 = 𝑐𝑐2 + 𝑑𝑑 = 0.78𝑚𝑚
2
𝑏𝑏 0.59
2𝑏𝑏1 � 1 � 2(0.59)( )
′
𝑥𝑥 = 2 = 2 = 0.178𝑚𝑚
2𝑏𝑏1 + 𝑏𝑏2 2(0.59) + (0.78)
1
𝛾𝛾𝑓𝑓1 = = 0.633
2 𝑏𝑏
1+ � 1
3 𝑏𝑏2
186
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
1
𝛾𝛾𝑓𝑓2 = = 0.566
2 𝑏𝑏
1+ � 1
3 𝑏𝑏2
𝑀𝑀𝑢𝑢2 = 0.07 �(𝑞𝑞𝐷𝐷𝐷𝐷 + 0.5𝑞𝑞𝐿𝐿𝐿𝐿 )𝐿𝐿2 𝐿𝐿𝑛𝑛 2 − 𝑞𝑞𝐷𝐷𝐷𝐷 ′ 𝐿𝐿2 ′ 𝐿𝐿𝑛𝑛′ 2 � = 14.6𝑘𝑘𝑘𝑘. 𝑚𝑚
Where:
11.1𝑘𝑘𝑘𝑘
𝑞𝑞𝐷𝐷𝐷𝐷 = 𝑞𝑞𝐷𝐷𝐷𝐷 ′ = 1.2(5.75 + 3.5) =
𝑚𝑚2
4.8𝑘𝑘𝑘𝑘
𝑞𝑞𝐿𝐿𝐿𝐿 = 1.6(3) =
𝑚𝑚2
Check stress:
187
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
𝑣𝑣𝑢𝑢 1.447
= = 1.93𝑀𝑀𝑀𝑀𝑀𝑀
∅ 0.75
2
𝑣𝑣𝑐𝑐 ≤ 0.17𝜆𝜆𝑠𝑠 𝜆𝜆 �1 + � �𝑓𝑓 ′ 𝑐𝑐 = 2.4𝑀𝑀𝑀𝑀𝑀𝑀
𝛽𝛽
𝛼𝛼𝑠𝑠 𝑑𝑑
𝑣𝑣𝑐𝑐 ≤ 0.083𝜆𝜆𝑠𝑠 𝜆𝜆 �2 + � �𝑓𝑓 ′ 𝑐𝑐 = 2.1𝑀𝑀𝑀𝑀𝑀𝑀
𝑏𝑏𝑜𝑜
𝑣𝑣𝑢𝑢
𝑣𝑣𝑠𝑠 = − 𝑣𝑣𝑐𝑐 = 1.93 − 0.88 = 1.05𝑀𝑀𝑀𝑀𝑀𝑀
∅
1.05(1960)(180)
𝑉𝑉𝑠𝑠 = 𝑣𝑣𝑠𝑠 𝑏𝑏𝑜𝑜 𝑑𝑑 = = 370.44𝑘𝑘𝑘𝑘
1000
𝐴𝐴𝑣𝑣 𝑉𝑉𝑠𝑠 370440
= = = 4.9𝑚𝑚𝑚𝑚2 /𝑚𝑚𝑚𝑚
𝑠𝑠 𝑓𝑓𝑦𝑦𝑦𝑦 𝑑𝑑 420(180)
6(78.5)
𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 𝑜𝑜𝑜𝑜 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠, 𝑠𝑠 = = 96𝑚𝑚𝑚𝑚
4.9
𝑑𝑑 180
= = 90𝑚𝑚𝑚𝑚 < 96𝑚𝑚𝑚𝑚 𝑢𝑢𝑢𝑢𝑢𝑢 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 3𝜙𝜙10/90𝑚𝑚𝑚𝑚
2 2
Flexural stresses:
Direction 1:
188
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
In X-direction, the moment shall be resisted by a cross section of thickness, h= 230mm with
d= 180mm and a width equals to column width plus 1.5h from each side, so, width of section
is given by:
Check:
This reinforcement shall be checked if it is provided in a width of 1.30m in the column strip.
If not, additional steel shall be provided.
Direction 2:
The moment can be neglected because it is very small and the minimum steel shall be used.
Notes:
• Based on ACI 318-19, the shear stress can be calculated for each direction alone. In
direction 1, Vu and Mu1 are used and in direction 2, Vu and Mu2 are used.
• If Vu, Mu1 and Mu2 are used in shear stress calculations, the punching shear capacity,
vc can be increased by a ratio like 20%.
189
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
Given:
Solution:
Dimensions of beams:
Slab thickness:
190
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
𝑓𝑓𝑦𝑦 420
𝑙𝑙𝑛𝑛 �0.8 +
1400� 8.6 �0.8 + 1400�
ℎ= = = 0.2𝑚𝑚 ≥ 0.09𝑚𝑚 𝑜𝑜𝑘𝑘
36 + 9𝛽𝛽 36 + 9(1.21)
Check 𝛼𝛼𝑚𝑚 :
(0.4)(0.7)3
𝐼𝐼𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏 = = 0.011433𝑚𝑚4
12
The flange width of a voided slab unit ( I- section), bf= 520mm + 150mm = 670mm
191
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
0.67(0.32)3 0.52(0.2)3
𝐼𝐼 = − = 1.4828𝑥𝑥10−3 𝑚𝑚4
12 12
2𝛼𝛼𝑓𝑓2 + 2𝛼𝛼𝑓𝑓4
𝛼𝛼𝑓𝑓𝑓𝑓 = = 0.63 < 2
4
𝑓𝑓𝑦𝑦 420
𝑙𝑙𝑛𝑛 �0.8 + 1400� 8.4 �0.8 +
�
ℎ= = 1400 = 0.24𝑚𝑚
36 + 5𝛽𝛽(𝛼𝛼𝑓𝑓𝑓𝑓 − 0.2) 36 + 5(1.22)(0.63 − 0.2)
the moment of inertia of the solid slab of 0.24m thickness and 0.67m width is given by:
192
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
0.67(0.24)3
𝐼𝐼 = = 0.77𝑥𝑥10−3 𝑚𝑚4 < 1.4828𝑥𝑥10−3 𝑚𝑚4 𝑜𝑜𝑜𝑜
12
1
1 0.75 � � (1)√32(150)(280)(1.1)
𝐴𝐴𝐴𝐴𝐴𝐴 318 − 14: ∅𝑉𝑉𝑐𝑐 = ∅ 𝜆𝜆�𝑓𝑓′𝑐𝑐 𝑏𝑏𝑤𝑤 𝑑𝑑 = 6 = 32.7𝑘𝑘𝑘𝑘
6 1000
≈ 32.9𝑘𝑘𝑘𝑘 𝑜𝑜𝑜𝑜
2 2
𝑆𝑆𝑆𝑆𝑆𝑆𝑆𝑆 𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓, 𝜆𝜆𝑠𝑠 = � ≤ 1.0 → 𝜆𝜆𝑠𝑠 = � = 0.97
1 + 0.004 𝑑𝑑 1 + 0.004 (280)
ℎ 320
𝐿𝐿𝐿𝐿𝐿𝐿 𝜌𝜌𝑤𝑤 = 0.0018 � � = 0.0018 � � = 0.002
𝑑𝑑 280
So,
1 𝑁𝑁𝑢𝑢
𝐴𝐴𝐴𝐴𝐴𝐴 318 − 19: ∅𝑉𝑉𝑐𝑐 = ∅ �0.66𝜆𝜆𝑠𝑠 𝜆𝜆(𝜌𝜌𝑤𝑤 )3 �𝑓𝑓 ′ 𝑐𝑐 + � 𝑏𝑏 𝑑𝑑
6𝐴𝐴𝑔𝑔 𝑤𝑤
1
(1.1)(0.75) �0.66(0.97)(1)(0.002)3 √32 + 0.0� (150)(280)
=
1000
= 15.8𝑘𝑘𝑘𝑘 < 32.9𝑘𝑘𝑘𝑘 𝑁𝑁. 𝐺𝐺.
So, use minimum shear reinforcement in the ribs at least for ¼ the clear span at each end.
193
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
1. Compute the total statical moment, Mo for the span. Here the three spans are equal.
𝐿𝐿2 7.5
= = 0.83
𝐿𝐿1 9
From ACI 318-14 Table 8.10.5.5, for positive moment, the ratio = 71.6%
From ACI 318-14 Table 8.10.5.1, for interior negative moment, the ratio = 77.9%
194
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
Ecb C 𝐶𝐶 0.00955733
βt = = = = 0.29
2Ecs Is 2𝐼𝐼𝑠𝑠 2 7.5 (1.4828𝑥𝑥10−3 )
0.67
𝛼𝛼𝑓𝑓 𝐿𝐿2
= 0.575
𝐿𝐿1
𝐿𝐿2
= 0.83
𝐿𝐿1
From ACI 318-14 Table 8.10.5.2, for exterior negative moment, the ratio = 97.4%
𝛼𝛼𝑓𝑓 𝐿𝐿2
Since = 0.575, the ratio of moments that are transferred to beams is:
𝐿𝐿1
0.575 (0.85)=0.49
Figure 8.41 shows the bending moment diagram of the beam in frame 2.
195
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
The slab column strip moment = the column strip moment – the beam moment
The slab middle strip moment = the frame moment – the column strip moment
For example: the maximum bending moment in the column strip, Mu= 292.89kN.m
196
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
Then,
2825 753𝑚𝑚𝑚𝑚2
𝐴𝐴𝑠𝑠 = 0.00269(3750)(280) = 2825𝑚𝑚𝑚𝑚2 𝐴𝐴𝑠𝑠 = =
3.75 𝑚𝑚
Use 1∅14/200𝑚𝑚𝑚𝑚
197
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
Given:
Solution:
Dimensions of beams:
Slab thickness:
𝑓𝑓𝑦𝑦 420
𝑙𝑙𝑛𝑛 �0.8 + 1400� 8.6 �0.8 + �
ℎ= = 1400 = 0.2𝑚𝑚 ≥ 0.09𝑚𝑚 𝑜𝑜𝑜𝑜
36 + 9𝛽𝛽 36 + 9(1.21)
where: Ln= 9.0-0.60=8.40m
Check 𝛼𝛼𝑚𝑚 :
198
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
(0.4)(0.7)3
𝐼𝐼𝑏𝑏𝑏𝑏𝑏𝑏𝑏𝑏 = = 0.011433𝑚𝑚4
12
The flange width of the waffle slab unit ( T- section), bf= 600mm + 150mm = 750mm
The moment of inertia of one unit of width 750mm is equal to 4.935x10-4 mm4.
199
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
2𝛼𝛼𝑓𝑓2 + 2𝛼𝛼𝑓𝑓4
𝛼𝛼𝑓𝑓𝑓𝑓 = = 2.1 > 2 𝑂𝑂𝑂𝑂
4
1
1 0.75 � � (1)√32(150)(220)(1.1)
𝐴𝐴𝐴𝐴𝐴𝐴 318 − 14: ∅𝑉𝑉𝑐𝑐 = ∅ 𝜆𝜆�𝑓𝑓′𝑐𝑐 𝑏𝑏𝑤𝑤 𝑑𝑑 = 6 = 23.3𝑘𝑘𝑘𝑘
6 1000
< 33.5𝑘𝑘𝑘𝑘 𝑈𝑈𝑈𝑈𝑈𝑈 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠.
𝑉𝑉𝑐𝑐 = 31.1𝑘𝑘𝑘𝑘. 𝑚𝑚
34.0
𝑉𝑉𝑠𝑠 = � � − 31.1 = 14.2𝑘𝑘𝑘𝑘. 𝑚𝑚
0.75
200
Design of Reinforced Concrete Structures: A Practical Approach IBRAHIM ARMAN
𝐴𝐴𝑣𝑣 14.2𝑥𝑥1000
= = 0.154𝑚𝑚𝑚𝑚2 /𝑚𝑚𝑚𝑚
𝑠𝑠 420𝑥𝑥220
𝐴𝐴𝑣𝑣
𝑈𝑈𝑈𝑈𝑈𝑈 = 0.154𝑚𝑚𝑚𝑚2 /𝑚𝑚𝑚𝑚
𝑠𝑠
100 𝑑𝑑
𝑠𝑠 = = 667𝑚𝑚𝑚𝑚 > 𝑠𝑠𝑚𝑚𝑚𝑚𝑚𝑚 = = 100𝑚𝑚𝑚𝑚
0.15 2
So, use closed stirrups at ends of ribs for one quarter the clear span (The accurate distance
can be specified).
Analysis of frame 2:
Compute the total statical moment, Mo for the span. Here the three spans are equal.
Note:
The moments in the frame, beam, slab column strip and slab middle strip can be found
using the same procedure in the previous examples.
𝑀𝑀𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠
𝑀𝑀𝑟𝑟𝑟𝑟𝑟𝑟,𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 = 𝑥𝑥 𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓 𝑤𝑤𝑤𝑤𝑤𝑤𝑤𝑤ℎ; 0.75𝑚𝑚
𝑤𝑤𝑤𝑤𝑤𝑤𝑤𝑤ℎ 𝑜𝑜𝑜𝑜 𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐𝑐 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠
𝑀𝑀𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠
𝑀𝑀𝑟𝑟𝑟𝑟𝑟𝑟,𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑙𝑙𝑒𝑒 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 = 𝑥𝑥 𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓 𝑤𝑤𝑤𝑤𝑤𝑤𝑤𝑤ℎ; 0.75𝑚𝑚
𝑤𝑤𝑤𝑤𝑤𝑤𝑤𝑤ℎ 𝑜𝑜𝑜𝑜 𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚 𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠
201