CHAPTER 8: Detail Laboratory Test Schedule Showing the Critical Pass of the Laboratory Test.

Project: Bangabandhu Sheikh Mujib Railway Bridge Project

8.1 General
Prosoil Lanoratory has planned to assign the laboratory management, testing and reporting
tasks to its experienced team of Engineers, CAD Operators and Technicians.

8.2 Organogram for Laboratory Testing


In laboratory organogram, there are one engineer in-charge and one advisor for executing the
entire tasks to be carried out in the laboratory. Further, the entire volume of work will be
splitted among four sub teams: Physical Test Team, Chemical Test team, Mechanical Test
Team-1 and Mechanical Test Team-2.
The laboratory and the reporting organograms are given in Figure 8.1 and Figure 8.2,
respectively.

Firm’s Prosoil Foundation Consultant


Name
Authorized
Signature
Page 8-1
CHAPTER 8: Detail Laboratory Test Schedule Showing the Critical Pass of the Laboratory Test.
Project: Bangabandhu Sheikh Mujib Railway Bridge Project

Laboratory
In charge: Sayada Mahfuza Siddika

Physical Test Chemical Test Mechanical Test Mechanical Test


Kakoli Saha (Diploma Engr) -Engr. Mashrura Yeasmin Auditia (B.Sc) -Engr. Sultana Tajkiya Akhter (B.Sc) Engr. Ahasan Habib(B.Sc)
m - Laboni Talukdar Natasa (Diploma Engr)
-Laboni Talukdar Natasa
Grain Size Analysis (Diploma Engr)
Triaxial (UU Test)
(Hydrometer and Sieve analysis) -
Consolidation - Laboni Talukdar Natasa (Diploma Engr)
- Taslima Khatun (Diploma Engr) - Mahfuza Akter (Diploma Engr.) - Ariful Islam (Technician)
-Ariful Islam (Technician) - Md. Akbar Hossain (Technician) - Md. Limon (Technician)

Direct Shear Triaxial (CU Test and CD)


Atterberg Limit Analysis - - Rahima Akter (Diploma Engr.) - Laboni Talukdar Natasa (Diploma Engr)
(Liquid and Plastic Limit) -Ariful Islam (Technician) - Md. Didar Hossain (Technician)
- Taslima Khatun (Diploma Engr) - Md. Limon (Technician)
- Alamin Shaikh (Technician)
- Md. Didar Hossain (Technician)
UCS
Permeability Test - Laboni Talukdar Natasa (Diploma Engr)
- Rahima Akter (Diploma Engr.) -Md. Akbar Hossain (Technician)
- Md. Didar Hossain (Technician)
Specific Gravity Test
- Taslima Khatun (Diploma Engr)
- Md. Maksud Alam (Technician) CBR
- Test/Compection (optional)
- (Diploma Engr.)
- Md. Didar Hossain (Technician)
Nature Moisture Content Test and Bulk Dry - Md. Akbar Hossain (Technician)
Density - Md. Maksud Alam (Technician)
- Taslima Khatun (Diploma Engr) -Ariful Islam (Technician)
- Md. Limon (Technician)

Figure 8.1 Laboratory Organogram

Firm’s Prosoil Foundation Consultant


Name
Authorized
Signature
Page 8-2
CHAPTER 8: Detail Laboratory Test Schedule Showing the Critical Pass of the Laboratory Test.
Project: Bangabandhu Sheikh Mujib Railway Bridge Project

Reporting
In Charge: Engr. Md. Shamsul Islam, M.Engg

Geotechnical Coring Tip Contact Strain Gauge, PDA/DLT CSL & PIT Plate Load Test
Investigation Inclinometer &
Thermocouple
Reporting In Charge: Reporting In Charge: - Reporting In Charge: Reporting In Charge:
Reporting In Charge: Reporting In Charge:
Engr. Riffat Shahrin Reporting In Charge:
Engr. Md.Shamsul Engr. Riffat Shahrin Engr. Ananna Biswas,
Ridi, M.Sc (ongoing) -Engr. Md.Shamsul -Engr. Md.Shamsul - Engr. Ahasan Habib, Ridi, M.Sc (ongoing) B,Sc
Islam, M.Engg
Islam, M.Engg Islam, M.Engg B.Sc

Physical, Chemical and Mechanical Tests Analysis of strain PDA/DLT Analysis by Analysis of CSL
Engineers gauge and DLTWave Software: Software
Engr. Mashrura Yeasmin (B.Sc) inclinometer data -Engr. Sultana Tajkiya - Ashrafa Ahmed
Engr. Sumaita Fatema Siddique (B.Sc) -Engr.Mashrura Akhter, B.Sc Aurthy
Diploma Engineers Yeasmin, B.Sc
Taslima Khatun
Ashrafa Ahmed Aurthy
CAD- Operator
Mina Akter
Sampa Akter

Figure 8.2: Reporting Organogram

Firm’s Prosoil Foundation Consultant


Name
Authorized
Signature
Page 8-3
CHAPTER 8: Detail Laboratory Test Schedule Showing the Critical Pass of the Laboratory Test.
Project: Bangabandhu Sheikh Mujib Railway Bridge Project

8.4 Critical Pass of Laboratory Test

Natural
Moisture
Content Test
(NMC)
Grain Size
California Analysis Test

Nos. /2
Bearing Ratio Hydrometer

days
Test

30
20 Nos./ 2 days
(CBR) Sieve Analysis
20 Nos./ 2 days

Physical Tests
on Disturbed
Soil Samples
Nos . /2

Specific
day s

Atterberg
Gravity Test
2

Limit Test
(SPG)

Compaction
Test

Figure 8.3 : Critical Pass for Physical Tests on Disturbed Soil Sample at Prosoil
Foundation Consultant

Firm’s Prosoil Foundation Consultant


Name
Authorized
Signature
Page 8-4
CHAPTER 8: Detail Laboratory Test Schedule Showing the Critical Pass of the Laboratory Test.
Project: Bangabandhu Sheikh Mujib Railway Bridge Project

Mechanical
Direct
Test on 2 Nos. /
Shear
Disturbed day
Test
Soil Sample

Figure 8.4 : Critical Pass for Mechanical Tests on Disturbed Soil Sample at Prosoil
Foundation Consultant

Firm’s Prosoil Foundation Consultant


Name
Authorized
Signature
Page 8-5
CHAPTER 8: Detail Laboratory Test Schedule Showing the Critical Pass of the Laboratory Test.
Project: Bangabandhu Sheikh Mujib Railway Bridge Project

Tri-axial Test
(UU)

Unconfined
Compression Tri-Axial

Nos.
/day
Test Test (CU)

3
(UCS)

Mechanical Test
on Undisturbed
Soil Sample

Consolidation
2 Nos.

Tri-Axial
/day

Test Test (CD)

Permeability
Test

Figure 8.5 : Critical Pass for Mechanical Tests on Undisturbed Soil Sample at Prosoil
Foundation Consultant

Firm’s Prosoil Foundation Consultant


Name
Authorized
Signature
Page 8-6
CHAPTER 8: Detail Laboratory Test Schedule Showing the Critical Pass of the Laboratory Test.
Project: Bangabandhu Sheikh Mujib Railway Bridge Project

pH Value

Organic Chemical
Content Tests on 3 Nos. Chloride
Test Soil /day
Sample

N os.
/day

3
Sulfide
Test
(

Figure 8.6 : Critical Pass for Chemical Tests on Soil Sample at Prosoil Foundation
Consultant

pH
Value

Chemical
Tests on
Water
Sample
Sulfide Chloride
Test
(

Figure 8.7 : Critical Pass for Chemical Tests on Water Sample at Prosoil Foundation
Consultant

Firm’s Prosoil Foundation Consultant


Name
Authorized
Signature
Page 8-7