1.

TITLE SHEET: METROTOWNE DRAINAGE DISCHARGE CALCULATION

2. INTRODUCTION: Initial estimate to determine Drainage Discharge for the


Proposed Land Development entitled “METROTOWNE”
located at Marcos Alvarez Avenue, Talon II, Las Pinas City.

3. DESIGN CODE: Design Guidelines, Criteria and Standards (DGCS) 2015


Volume-3 Water Engineering Projects

4. ASSUMPTIONS: Rainfall Return Period (Frequency) – 15 years


Rainfall Weather Station – NAIA

5. DESIGN CRITERIA AND PARAMETERS:

o Total Drainage Area (SM) - 19,907


o Runoff Coefficient - 0.80
o Road Gradient Parallel to drainage - 0.50%
o Road Crossfall - 1.50%
o Road Pavement Surface - PCC
o Manning’s Roughness Coefficient (n) - 0.015
o Horton’s Surface Roughness Coefficient (*) - 0.015

6. CALCULATIONS:

A. Calculation of Drainage Discharge:

Design Discharge is computed using he Rational Formula:

Q =CIA/3.60

Where:
Q = Maximum Flood Discharge (m3/sec)
C = Dimensionless Runoff Coefficient
I = Rainfall Intensity within the Time of Flood Concentration
(mm/hr)
A = Catchment Area (km2)

a) Rainfall Intensity Determination, I

NINOY AQUINO INTERNATIONAL AIRPORT


Based on 40 Years of Record
Equivalent Average Intensity (in mm/hr) of Computed Extreme Value

3F Luisa Building II, 107 Maginhawa St, Barangay Teachers Village East, Quezon City, Philippines
Tel. (632) 5774143, Mobile: (0917) 546.2144 email: rubenvpajarillo@gmail.com
RAINFALL INTENSITY DURATION FREQUENCY CURVE (RIDF)

500.00

450.00

400.00
Rainfall Intensity (mm/hr)

2 YEARS
350.00
5 YEARS
300.00
10 YEARS
250.00
15 YEARS
200.00
20 YEARS
150.00 25 YEARS
100.00 50 YEARS
50.00 100 YEARS
0.00
0 20 40 60 80 100 120 140
Storm Duration (minutes)

The Drainage Area is quite small and the Overland Flow time (Time of Concentration) was
calculated less than 10minutes. Hence, Time of Concentration will be assumed to be 10min.

b) Design Discharge Using Rational Formula:

Q = CIA/3.60
= (0.80 * 252.60 * 19,907/1,000,000)/3.60
= 1.117 CMS

3F Luisa Building II, 107 Maginhawa St, Barangay Teachers Village East, Quezon City, Philippines
Tel. (632) 5774143, Mobile: (0917) 546.2144 email: rubenvpajarillo@gmail.com
SITE DRAINAGE LAYOUT PLAN

c) Pipe Capacity (Reinforced Concrete Pipe Culvert)

Q = AV

Where:

Q = Pipe Capacity, m3/sec


V = Velocity of Flow, m/sec
A = Pipe Cross-sectional Area, m2

3F Luisa Building II, 107 Maginhawa St, Barangay Teachers Village East, Quezon City, Philippines
Tel. (632) 5774143, Mobile: (0917) 546.2144 email: rubenvpajarillo@gmail.com
Velocity of flow in pipe shall be determined using Manning’s Equation:

For 900mm DIAMETER RCP: (OUTFALL-1)

V = [1 / n] x [(3.1416 x D2)/4) / (3.1616 x D)] 2/3 x [S]1/2

= [1/n] x [D/4]2/3 x S1/2

= [1 / 0.015] x [0.90/4]2/3 x [0.50]1/2

V = 1.98 m/sec.

Q = AV

= (3.1416 x 0.902 / 4) x 1.98

Q = 1.261 CMS > 1.117 CMS (pipe exceeds allowable 80% Capacity)

The 900mm Diameter RCP is 89% of its full capacity. It exceeds the allowable 80% pipe
allowable capacity. Hence, we can assume the next bigger size 1050mm Diameter.

We proposed to provide 1050mm Diameter RCP to take care of other drainage discharges
that the future development may construct.

Prepared By:

Ruben V. Pajarillo
Civil Engineer
PRC Reg. 16665
Registration Valid Until 01-24-2020
PTR No. 1735074
Date Issued: 01-16-19
Place of Issue: Paranaque City

3F Luisa Building II, 107 Maginhawa St, Barangay Teachers Village East, Quezon City, Philippines
Tel. (632) 5774143, Mobile: (0917) 546.2144 email: rubenvpajarillo@gmail.com