Professional Documents
Culture Documents
(7ZPNA4264B) Update Manual 56C 42A R2 E
(7ZPNA4264B) Update Manual 56C 42A R2 E
(7ZPNA4264B) Update Manual 56C 42A R2 E
7ZPNA4264B
JAN-701B/901B/2000/1186、NDC-1186-4xx
ECDIS/RPS/NWS
Software Update Manual for
Ver.00000056C(V56C)
(in case that the current version is 00000042A(V42A) or older)
Contents
z Outline ...................................................................................................................................................1
z Preface(Parts list in this work and estimate of working time)................................................................2
1. Flow chart ..............................................................................................................................................3
Step1:Creating the software update CD.......................................................................................................4
Step2:Confirming of latest Base CD, Update CD, and Cell permit(In case of using ENC) ...........................6
Step3:Confirming latest C-Map database DVD and license (in case of using C-Map) .................................6
Step4:Confirming of current software version. .............................................................................................7
Step5:Deleting Cell Permit (In case of using ENC) ......................................................................................9
Step6:Software update............................................................................................................................... 11
Step7:Confirming of software update .........................................................................................................20
Step8:Deleting of Playback data and Logbook data...................................................................................21
Step9:Confirming of SA Certificate and importing of Cell Permit (In the case of using ENC).....................23
Step10:Re-install of ENC(Contain AVCS) charts (In case of using ENC)...................................................29
Step11:Deleting of current ENC(Contain AVCS) charts (In the case of using ENC)...................................35
Step12:Re-installing C-Map database (in case of using C-Map)................................................................36
Step13:Re-installing C-Map license (in case of using C-Map) ...................................................................40
Step14:Confirming of “Navigation & Planning”...........................................................................................42
Step15:Storage of Update CD....................................................................................................................43
Step16:Sending of software update result .................................................................................................43
Reference Document 1: Alarm Information of S-57/S63 Chart ...................................................................44
Request for sending of software update result............................................................................................50
NA12AL1214A-3
7ZPNA4264B
z Outline
This is an update manual of Ver.00000056C from Ver.00000042A or older software for
JAN-701B/901B/2000/1186, NDC-1186-4xx.
In case of using ENC (Contain AVCS), delete Cell Permit before updating the software
according to “Step5:Deleting Cell Permit (In case of using ENC (Contain AVCS))”.
Otherwise, it may cause a malfunction which a part of charts are not displayed.
Attention
Even if software is updated to V56C, user map remains preserved without deleting.
1
NA12AL1214A-3
7ZPNA4264B
Download the files from TMSC or Amsterdam branch website and create the
Software update CD
software update CD according to Step:1
Software update manual Print this document and take it for ship.
ENC/AVCS Necessary in case of using ENC/AVCS
Data base CD (Use it at ship after getting from customer)
ENC/AVCS Necessary in case of using ENC/AVCS
Cell Permit CD (Use it at ship after getting from customer)
C-Map Ed.3 Necessary in case of using C-Map Ed.3
Database DVD (Use it at ship after getting from customer)
C-Map Ed.3 Necessary in case of using C-Map Ed.3
License file (Use it at ship after getting from customer)
(*1) Estimated time for re-installing ENC(including AVCS) charts: about 1 - 3 hours
about 30 minutes per 1 CD (the whole JAPAN)
※ If there are few equipment, estimated time for updating software is necessary by number of equipments.
2
NA12AL1214A-3
7ZPNA4264B
1. Flow chart
The work outline of the software update is described in the following. Confirm it before work by all means.
Start
Start Updating
Step2:Confirming of latest Base CD, Update CD, and Cell permit(In case of using ENC)
Step3:Confirming latest C-Map database DVD and license (in case of using C-Map)
Step6:Software update
Step9:Confirming of SA Certificate and importing of Cell Permit (In the case of using ENC)
Step11:Deleting of current ENC(Contain AVCS) charts (In the case of using ENC)
Step15:Storage of Update CD
Finish
3
NA12AL1214A-3
7ZPNA4264B
Parts list
Parts Qty Requirements
CD-R Media 1
PC(Windows) 1 CD-R writing software is installed.
CMCL4 Folder
3) Burn the 6 files and 1 folder which are confirmed in 2) to CD-R with CD-R writing software.
・ Don’t change file name, otherwise the software is not be installed correctly.
4
NA12AL1214A-3
7ZPNA4264B
4) Confirm the composition of CD-R. Confirm that each file is written to root directory.
ECDIS Update CD
JAN-701B/901B/2000/1186
NDC-1186-4xx
Maintenance Ver.56C
XXXXXXX 2013
5
NA12AL1214A-3
7ZPNA4264B
Step2:Confirming of latest Base CD, Update CD, and Cell permit(In case of
using ENC)
When executing software update and re-installing ENC (Contain AVCS) charts, following items are
required:
● Latest Base CD
● Latest Update CD
● Latest Cell Permit (In the case of update from before V42A)
Step3:Confirming latest C-Map database DVD and license (in case of using
C-Map)
After updating software, it is necessary to re-install C-Map database. So, following item is necessary at updating..
z Latest database DVD
z Latest license file
6
NA12AL1214A-3
7ZPNA4264B
POWER Key
POWER Key
POWER Key
7
NA12AL1214A-3
7ZPNA4264B
2) After ECDIS software start-up, move the cursor on the “Startup" menu, then right-click in the mouse of
the operation unit, and will be displayed the “PASSWORD" dialog.
3) When right-clicking again on the “PASSWORD" dialog, "Software keyboard" is displayed. Input the
password "85100" and left-click “ENT”.
85100
PASSWORD dialog
Startup menu
Please Fill in MaintenanceNo. on “Version before software updates” at "Request for sending of
software update result" that is the end page of this procedure.
8
NA12AL1214A-3
7ZPNA4264B
In case of using ENC (Contain AVCS), delete Cell Permit before updating the software.
Otherwise, it may cause a malfunction which a part of charts are not displayed.
Startup menu
2) Select [Tool] → [Option] at the Chart Portfolio window. ”Option” dialog is displayed.
3) Left-click [S-63]tab, then left-click [Delete Cell Permit...] button. Popup dialog box is displayed.
9
NA12AL1214A-3
7ZPNA4264B
5) Confirm that”You are NOT licensed.” is displayed in ”Cell Permit” of ”Option” dialog. And,
left-click the [Cancel] button to delete the Cell permit.
10
NA12AL1214A-3
7ZPNA4264B
Step6:Software update
In case of using ENC (Contain AVCS), delete Cell Permit before updating the software
according to “Step5:Deleting Cell Permit (In case of using ENC (Contain AVCS))”.
Otherwise, it may cause that a part of charts are not displayed.
For JAN-701B/901B, there is DVD drive when opening the cap in the upper part of front panel.
DVD drive
DVD drive
11
NA12AL1214A-3
7ZPNA4264B
2) Move the cursor on “Startup Menu”, and right-click the trackball on operation panel to display
“PASSWORD” dialog.
3) On “PASSWORD” dialog, right-click the trackball once again, then “Software Keyboard” is displayed
and Enter password “5858” and left-click “ENT”.
5858
4) Confirm that “Software Update: Q:¥EUpdate.exe” is displayed in the upper dialog box, and then
left-click [OK] button.
Attention
If the Software Update CD is not recognized, software data path is not displayed as following.
Left-click [Cancel] button and then confirm that Software Update CD is inserted in to the DVD Drive.
12
NA12AL1214A-3
7ZPNA4264B
Attention
If following message is displayed, this software is not accepted to update because of special
software. Please contact to JRC service agent.
Attention
If you stop software updating, re-install Cell Permit according to Step9. Because Cell permit
has been already deleted in Step5.
5) Following dialog is displayed. Confirm that upgrading version is “56C”, then left-click [Yes] button.
13
NA12AL1214A-3
7ZPNA4264B
14
NA12AL1214A-3
7ZPNA4264B
8) Update is started. It takes several minutes. You can not select [Close] button until update is finished.
15
NA12AL1214A-3
7ZPNA4264B
10) After updating the software "e-Token Setup" dialog is displayed. It is necessary to carry out this
operation even if C-map is used / not used. Left-click [Yes] button.
16
NA12AL1214A-3
7ZPNA4264B
This is the end of updating software If another ECDIS are installed, update other ECDIS
17
NA12AL1214A-3
7ZPNA4264B
Troubleshooting
Symptom/Cause/Countermeasure (common)
Symptom Cause Countermeasure
Pop-up of " If you have an eToken Please choose the direction suitable for
~" is re-displayed. eToken of use on the selection screen of
eToken type.
By selection of eToken type,
eTokenPro (Java) is chosen and
eToken cannot be recognized.
Registration of eToken
Please equip with eToken and redo
information has not been
update operation.
performed.
18
NA12AL1214A-3
7ZPNA4264B
Attention
If software updating stops, carry out as follows.
Resumption procedure of update
(1) Insert update CD in a CD-ROM drive.
(2) Select [Start]button-[Run...]menu
19
NA12AL1214A-3
7ZPNA4264B
1) Move the cursor on the “Startup" menu, then right-click in the mouse of the operation unit, and will be
displayed the “PASSWORD" dialog.
2) When right-clicking again on the “PASSWORD" dialog, then "Software keyboard" is displayed. Input
the password "85100” and left-click “ENT”.
85100
PASSWORD dialog
Startup menu
3) “System Information” is displayed. Please confirm that “Maintenance No. “ is “00000056C” and
“C-Map SDK“ is ”Ver.5.2.2.65”.
1) Move the cursor on the “Startup" menu, then right-click in the mouse of the operation unit, and will be
displayed the “PASSWORD" dialog.
2) When right-clicking again on the “PASSWORD" dialog, then "Software keyboard" is displayed. Input
the password "1101" and left-click “ENT”.
1101
PASSWORD dialog
Startup menu
Required time to delete depends on the data, it may take some time.
21
NA12AL1214A-3
7ZPNA4264B
The procedure of deleting Logbook data
1) Move the cursor on the “Startup" menu, then right-click in the mouse of the operation unit, and will be
displayed the “PASSWORD" dialog.
2) When right-clicking again on the “PASSWORD" dialog, then "Software keyboard" is displayed. Input
the password "1102" and left-click “ENT”.
1102
PASSWORD dialog
Startup menu
Required time to delete depends on the data, it may take some time.
This is end of deleting of Playback data and Logbook data.
22
NA12AL1214A-3
7ZPNA4264B
Confirm SA Certificate file and import Cell Permit according to below procedure.
Confirming of SA Certificate
Startup menu
2) Select [Tool] → [Option] at the Chart Portfolio window. ”Option” dialog is displayed.
23
NA12AL1214A-3
7ZPNA4264B
4) Select the SA Certificate file of data server for importing or update charts according to
following list.
When SA Certificate supplied from the Non-IHO is selected, “Warning:SSE26” is displayed. That is no problem in
chart importing.
24
NA12AL1214A-3
7ZPNA4264B
25
NA12AL1214A-3
7ZPNA4264B
Import of Cell Permit
After confirming of SA Certificate file, import Cell Permit according to below procedures.
1) Start up “ChartPortfolio”.
2) Select [Tool] → [Option] at the Chart Portfolio window. ”Option” dialog is displayed.
26
NA12AL1214A-3
7ZPNA4264B
4) Insert Cell permit CD-ROM into DVD drive, and then wait until ready to read.
(c) (b)
(a)
7) Double click Cell Permit file name (e.g. “permit.txt”) from [File name] (c).
Attention
・ Insert FD, and then select Cell permit[A:](A drive) if receiving Cell Permit by FD.
・ If receiving Cell permit by e-mail, save “Permit.txt” file into USB memory and insert
USB memory into USB port, then select [F:](F drive).
- Save only “Permit.txt” file into USB memory.
- If “Permit.txt” is compressed, execute decompression before saving into USB memory.
27
NA12AL1214A-3
7ZPNA4264B
10) Confirm the number of chart license after importing Cell Permit.
11) The number equal to contracted license.
12) If cell Permit is published from a number of data server, repeat above 3)~10).
13) Left-click [OK] button, then S-63 Cell Permit import is end.
28
NA12AL1214A-3
7ZPNA4264B
29
NA12AL1214A-3
7ZPNA4264B
Attention:
• When UPDATE information is included in the BASE CD-ROM(PRIMAR or
UKHO (AVCS ) ), the following dialog box appears. Left-clicked the [OK]
button.
30
NA12AL1214A-3
7ZPNA4264B
[Log] button
[Log] window
31
NA12AL1214A-3
7ZPNA4264B
5) Check that the import process is completed, and then, left-click the [Exit] button to exit Chart Portfolio.
32
NA12AL1214A-3
7ZPNA4264B
Troulbeshooting
If an error message is displayed during the reinstallation ENC(including AVCS) chart, please see the table
below.
1. Symptom/Cause/Countermeasure
Symptom Cause Countermeasure
Message “There is no licensed chart.” Importing charts are not covered for
is displayed in Chart Portfolio. Check the details of the contract.
the chart existed in ECDIS.
Error code ”error(0x000000xx)”is Refer to the attached document Refer to the attached document
displayed in log window of Chart ‘Reference Document 1: Alarm ‘Reference Document 1: Alarm Information
Portfolio. Information of S-57/S63 Chart’. of S-57/S63 Chart’.
33
NA12AL1214A-3
7ZPNA4264B
Symptom Cause Countermeasure
Message“Warning:SSE 10 - Permits not Data server ID written in serial.enc
Use the correct CD or Import the correct
available for this data provider. ” is that is included in CD is different from
Cell Permit
displayed in Chart Portfolio. Data server ID written in Cell Permit.
Message“Warning:SSE 20 -
Subscription service will expire in less
There are some Cell Permit that will
than 30 days. Please contact your data Regist the latest Cell permits.
expire within 30 days.
supplier to renew the subscription
licence.” is displayed in Chart Portfolio.
Even if the latest Cell permit is
registered, “Warning:SSE 15 -
Register the latest Cell permit after
Subscription service has expired.
Expired Cell permits are remaindered. deleting Cell permit. See “2.7 Deleting
Please contact your data supplier to
Cell Permit (Only S-63)”.
renew the subscription licence.”
message is appeared.
Message “Warning:SSE 26 - This ENC
is not authenticated by the IHO acting as Selected SA is Certificate supplied
That is no problem in chart importing.
the Scheme Administrator. ” is displayed from the Non-IHO.
in Chart Portfolio.
34
NA12AL1214A-3
7ZPNA4264B
Step11:Deleting of current ENC(Contain AVCS) charts (In the case of
using ENC)
1) Move the cursor on “Startup Menu”, and right-click the trackball on operation panel to display
“PASSWORD” dialog.
2) On “PASSWORD” dialog, right-click the trackball once again, and “Software Keyboard” is displayed.
Enter password “1106” and left-click “ENT”.
1106
PASSWORD dialog
Startup Menu
3) The dialog box for the chart deleting appears. Then Left-click “OK” button.
35
NA12AL1214A-3
7ZPNA4264B
In case that before updating version is V54 or older, re-installing C-map database is need. Re-install the C-map
database as follows.
Startup menu
36
NA12AL1214A-3
7ZPNA4264B
37
NA12AL1214A-3
7ZPNA4264B
38
NA12AL1214A-3
7ZPNA4264B
11) In case that licensing database DVD is more two, carry out from 1) to 10) each database.
39
NA12AL1214A-3
7ZPNA4264B
Step13:Re-installing C-Map license (in case of using C-Map)
In case that before updating version is V54 or older, re-installing C-map license is need. Re-install the C-map
license as follows.
Attention:
C-Map Dynamic Licensing service is need other licensing procedure.
So please see the Chart installation manual.
2) Select the installing database at Licenses tab. And left-click [Import from file].
40
NA12AL1214A-3
7ZPNA4264B
4) If importing license is succeeding, the following message is displayed. So, left-click [OK] button.
6) In case that licensing database DVD is more two, carry out from 1) to 5) each database.
41
NA12AL1214A-3
7ZPNA4264B
1) Left click “Startup” menu in button and start “Navigation & Planning”.
2) Confirming “Navigation & Planning” start normally and GPS,Gyro,Log sensor input.
42
NA12AL1214A-3
7ZPNA4264B
Step15:Storage of Update CD
Software update CD may be reused.
Please keep software update CD on the ship importantly after the software update is completed.
z Please put this manual and software update CD in a clear file on the back side of the front cover for
JAN-701B/901B. It is possible to open the front cover by loosening the screws of the four corners.
Please put this manual and upgrade CD in a clear file on the back side of the front cover.
z The equipments for JAN-2000/1186、NDC-1186-4xx have no storage area in the system, please
keep this manual and software update CD importantly on the ship.
43
NA12AL1214A-3
7ZPNA4264B
This section explains the details of the alarm information that may appear inside the log window of Chart
Portfolio while S-57/S-63 chart is imported/updated on ECDIS.
error(0x00000009)
File structure in Chart CD
9 error: Data
is abnormal.
structure
Attribute value of the
error(0x0000000A) objects defined in the chart
10
error:Attribute file of Chart CD is
abnormal.
44
NA12AL1214A-3
7ZPNA4264B
error(0x00000011)
Acquisition of chart object
17 error:Object Class
information is faulty.
get
Contact the retailer of the chart for the
error(0x00000012) measures to take.
18 error: Directory File path is abnormal.
create
Topology of the chart
error(0x00000013)
19 object in Chart CD is
error:Topology
abnormal.
error(0x00000014) Clean the CD-ROM, and then, perform import
Link of chart area object
20 error:Area Object procedure again.
in Chart CD is abnormal.
Link
If the error persists, contact the distributor of
error(0x00000015)
Link of line object in Chart the chart for the measures to take.
21 error: Line Object
CD is abnormal. It is a fatal error for Chart CD. Neither import
Link
nor update is possible for this Chart CD.
error(0x00000016)
Chart object in Chart CD
22 error: Object
is out of boundary.
outside range
45
NA12AL1214A-3
7ZPNA4264B
error(0x00000001) Memory allocation is Contact the retailer of the chart for the
1
error:Memory get faulty measures to take.
error(0x0000000C)
Acquisition of warning file
12 error:Warning Cell
of SENC is faulty.
data
46
NA12AL1214A-3
7ZPNA4264B
error(0x00000016)
Acquisition of chart object Contact the retailer of the chart for the
22 error:Object Class
information is faulty. measures to take.
get
47
NA12AL1214A-3
7ZPNA4264B
error(0x00000021)
Contact the retailer of the chart for the
33 error:Directory File path is abnormal.
measures to take.
create
48
NA12AL1214A-3
7ZPNA4264B
error(0x00000025)
Chart object of Update
37 error:Object Clean the CD-ROM, and then, perform import
CD is out of boundary.
outside range procedure again.
error(0x00000026) Chart point object of
38
error:point Update CD is abnormal. If the error persists, contact the distributor of
the chart for the measures to take.It is a fatal
error(0x00000027) error for Update CD. This chart cannot be
Edition number of Chart
39 error:Edition updated.
CD is abnormal.
number
49
NA12AL1214A-3
7ZPNA4264B
Request for sending of software update result
Please fill in the update result on the following tables and send it to our company after software upgrading
and reinstalling the chart is completed. Please submit one piece a model.
Addressee Marine Service Department(TMSC)
FAX 03-3779-1420 (+81-3-3779-1420)
E-mail ecdis-disp@jrc.co.jp
Please apply the sign to the equipment used.
Equipment model JAN-701B JAN-901B JAN-2000 JAN-1186
NDC-1186-4xx
Serial number
Ship’s name
The name of customer
The contact information of
customer
Version before software
updates
Version after software
updates
C-MAP SDK Version
before software updates
C-MAP SDK Version
after software updates
Storage area of software
update CD
Please apply the sign to the chart used.
Use chart ENC(Contain AVSC) ARCS C-MAP Ed.3
Others( )
Please apply the sign of the deletion existing chart.
All chart deletion No deletion
Branch office/branch/agency
50