11.0 Bolted Beam to Beam Shear + Tension End plate connection: IS 800 - 2007
11.1 Type I (Refer 11.1.4 for Section Properties)
11.1.1 Design forces:
Shear force for design of connection = 1.00 kN
Tensile force for design of connection = 56.00 kN
Dia. of Bolt d = 20 mm
Dia. of Bolt hole do = 22 mm
2
Ultimate strength of Bolt fub = 800 N/mm
2
Yield strength of Bolt fyb = 640 N/mm
2
Yield strength of the beam fybe = 250 N/mm
2
Tensile strength of Beam fube = 410 N/mm
2
Yield strength of Column fyc = 250 N/mm
2
Tensile strength of Column fuc = 410 N/mm
2
Yield strength of End plate fyE = 250 N/mm
2
Tensile strength of End plate fUE = 410 N/mm
2
Ultimate tensile stress of weld fUW = 410 N/mm
Eff. Shear area , Anv = (fy/fu)(rm1/rmo) Av/0.9 936 = (250/410) (1.25/1.1) x Ave Cl. 8.4.1.1 (Note)
0.9
2
Av = 1215.75 mm
Ave = MIN(1200 , 1215.75)
2
Ave = 1200.00 mm
Shear capacity of End plate Vd = Vn / gmo Cl. 8.4.1.1
Vn = Vp
Vp = Ave fy/√3
DOCUMENT. NO. DATE DESIGNED DATE
PROJECT CANTILEVER ROOF
12 04 22 AS 12 04 22
= 1200 x 250/sqrt(3)
= 173.21 kN
Vd = 173.21/1.1
= 157.46 kN
> 1.00 kN
Hence O.k
= 600 mm2
Avn = [d - Lv -((Nr - 0.5)do)]t
= [100 - 50 - ((1 - 0.5) x 22) x 12]
= 468 mm2
Atg = (Lh t)
= (50 x 12)
= 600 mm2
Atn = (Ln - (0.5 do)) t
= (50 - (0.5 x 22)) x 12
= 468 mm2
Avg FyE/√3 gmo + 0.9 Atn FuE/ gm1 = 600 x 250/Sqrt(3) x 1.1
+ 0.9 x 468 x 410/1.25
= 216.88 kN
(0.9Avn FuE/√3 gm1 + Atg FyE/ gmo) = (0.9x468x410)/(Sqrt(3) x 1.25)
+(600 x 250) / 1.1
= 216.13 kN
Tdp = min(216.883,216.13)
= 216.13 kN
The Plate will be Block sheared > 0.50 kN
at TWO Locations Hence O.k
lv f 0 be t 4
Q Te 2
2le 27le lv