SN BOQ - G+2 Final
SN BOQ - G+2 Final
10.1.1
MODEL: COMPACT
Size :- 500 x 400 No 30.00
MODEL: SINGLE BOWL
Size :- 1200 x 600 No 60.00
10.1.2
Brand: R.A.K.
Model: COMPACT No 52.00
10.1.4
Supply and fix R.A.K. or Equivalent white glazed vitreous china
wall mounting type toilet paper holder with chrome plated
fastening screws and other accessories.
No 52.00
10.1.5
Supply and fix 6mm thick crystal glass mirrors for hand wash
basins with copper back protection, including chrome plated
brass mirror clips with chrome plated screws and etc... for hand
wash basins.
PAGE 1 OF 7
G+2+T RESIDENTIAL BUILDING SUPERSTRUCTURE
10.1.7
Supply and fix R.A.K. or Equivalent white glazed vitreous china
wall mounting type soap holder with chrome plated fastening
screws and other accessories.
No 139.00
10.1.8
Supply and fix floor drains made of uPVC circular box of
approved quality for grey water with 4- side openings, complete
with P-smell trap, treaded drain/clean bottom outlet, approved
standard plastic cover and all other necessary fittings and
accessories
10.1.9
Supply and fix Kitchen Sink made of 1.2mm thick Stainless steel
Grade SS-304 having bowl with drain outlet, REMER/JAQUAR
or Equivalent chrome plated brass of diameter 40mm P-smell
trap, drain cover, Overflow outlet and all other accessories. The
price include REMER/JAQUAR or Equivalent chrome plated cold
and hot water wall mounted mixer tap (chromeplated faucet),
Flexible hose to be REMER/JAQUAR or Equivalent and should
be capable of resisting pressure of 4 bar.
10.1.10
Supply and fix ARISTON or Equivalent electric water heater
with a capacity given below. Complete with all water proofing,
mounting and fastening material, safety, one-way valve and gate
valve and with all the accessories.
10.1.11 Supply and fix approved standard shower tray made of acrylic
tray
Accessories and Fittings
- Chrome plated shower head, Diameter 100mm
- Chrome plated mixing faucet valve
- Chrome plated shower arm of length = 300mm,
with ball joint
- Polypropylene (PP) P-smell trap with 50mm
water seal
Including all the necessary acessories.
Size:- 800mm X 800mm x 13 mm No 52.00
PAGE 2 OF 7
G+2+T RESIDENTIAL BUILDING SUPERSTRUCTURE
10.2.1
Dia. 20 mm ml 1,002.00
Dia. 25 mm ml 132.00
Dia. 32 mm ml 120.00
10.2.2
No 999.00
10.2.3
Supply and fix PPR service valves of approved standard, capable
of resisting PN-10 on internal branch and pipe inlet to toilet,
kitchen, bath room, etc; of the following size and as where shown
on the drawing. (Provisional Measurements)
Dia. 20 mm No 333.00
PAGE 3 OF 7
G+2+T RESIDENTIAL BUILDING SUPERSTRUCTURE
All domestic waste, vent and storm water pipe line sshall be
comply to BS 459, BS 4660, BS 5481 as appropriate, using
double ring seals and gaskets complying with BS 2394 uPVC,
PN-6 pipes and shall be provided with a minimum slope as stated
in the drawing. Pipes and necessary fittings shall be standard
quality and be free from damage during storage, construction and
etc. Unit price shall include all the necessary assistance civil
works, such as excavation cartaway, fixing or hanging to walls,
beams or slabs. etc., necessary fittings such as bends, Y, etc.
Storm water uPVC, PN-6 pipes shall resist the external
temperature and the quality shall meet the purpose. Flushing and
testing of waste water system.Flushing has to be done to clean the
pipe line from debris and silts. All waste water Pipe shall be
tested by water pressure of 1.5 meters head for minimum of Four
Hours.
10.3.1
10.3.2 Supply, fix, test and commission Vent caps made of uPVC, PN-6
complete with all accessories.
Dia. 110 mm No. 29.00
10.3.3
10.3.4
Supply, Fix and test flat strainers on the roof terminal of storm
water drainage pipes as where shown on the drawing. Price shall
include all the necessary connecting pieces including gaskets and
all water tight connections as required.
SPECIAL CHARACTERSTICS
PAGE 4 OF 7
G+2+T RESIDENTIAL BUILDING SUPERSTRUCTURE
Testing: Pond testing for atleast 24 hours should be done after the
contructor has acomplished the water proffing work. The surface
should be re-treated if leakage observed; and the test should be
done on the repaired surface.
10.4.1
m2 670.25
10.5.1
Supply and install high density polyethylene pipe, HDPE pipes,
PN-10 to site cold water distribution system as shown on the
drawing. Complete with all the necessary fittings and accessories.
(Provisional Measurements)
Dia. 32 mm ml 50.00
PAGE 5 OF 7
G+2+T RESIDENTIAL BUILDING SUPERSTRUCTURE
Accessories
- Dia. 50 mm strainers with foot valve No 1.00
PAGE 6 OF 7
G+2+T RESIDENTIAL BUILDING SUPERSTRUCTURE
10.5.4
Supply and install water meter of approved quality price shall
include gate valves after and before water meter.
PAGE 7 OF 7