Download as pdf
Download as pdf
You are on page 1of 14
IsitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3. Components 3.3.1 Lithium Battery ESM-48100B1 Appearance Figure 3-83 ESM-4810081 Table 3-72 Panel and ports description No. silk Screen | Item Description 1 [eno Protective ground _| M6 screw 2 [bor ESM dry contact | Alarm output dry contact; output configurable (if the dry contact is bo2z closed, an alarm is reported by default). For details, see Table 375, 3 [comin Communications | 1. Used for information reporting Port 4 | com_our and communication cascading 2. Use RIMS terminals and provide the 1000 A surge protection capability. For details, see Table 3-74. 5 [RUN Run indicator ALM Alarm indicator CHG Charge indicator For the diagram, see Figure 3-85. For details about functions, see Table 3-73. issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Ltd. 3B isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3. Components Silk Screen. ESM negative terminal No. Item Description DCHG Discharge indicator soc SOC indicator 6 | MANUAL Button for manual | A contact button used for ON/OFF power-on/off manual power-on/off and maintenance. For details, see Activation and Startup. 7 [pwr ESMU port for The ESM can be activated if the connecting to. an —_| PWR port is supplied with a external power voltage of 432-58 V. For details, source see Activation and Startup. a |+ ESM positive Positive and negative ports of the terminal ESM. Secured by M6 screws. Appropriate OT terminals should be used. The required torque is 4 Nem and the recommended cable size is 25 mm?. If the ESM is used at a temperature below 45°C, the cable size can be smaller but should be at least 16 mm?, LED Indicator Figure 3-85 LED indicator issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Ita. 34 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3 Components Table 3-73 LED indicator description silk Item’ Color | Description Screen RUN Run Green _ Steady on: Communication is normal indicator (including board startup, self-check, software loading, and board power-on when not loaded; excluding sleep when the power port or PWR port is energized). Off: The ESM is in sleep mode. Blinking at long intervals: The LUI is querying data. Blinking at short intervals: Communication is interrupted. ALM Fault Red | Steady on: There is a fault or major alarm. indicator Off: There Is no fault or major alarm. Blinking slowly: Anti-theft lock. cHG — | Charge | Green _| Steady on: The ESM is being charged. Indicator Off: The ESM is open-circuited or discharging. DCHG — | Discharge ] Green | Steady on: The ESM is discharging, indicator Off: The ESM is open-circuited or being charged. issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Utd 5 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual silk Item Screen Color Description 3. Components soc soc indicators Green 1. 024% capacity 25% indicator: blinking Other SOC indicators: off 2. 25%-49% capacity 25% indicator: steady on 50% indicator: blinking Other SOC indicators: off 3, 50%-74% capacity 25% indicator: steady on 50% indicator: steady on 75% indicator: blinking Other SOC indicators: off 4, 75%-99% capacity 25% indicator: steady on 50% indicator: steady on 75% indicator: steady on 100% indicator: blinking 5. 100% capacity The four SOC indicators are steady on. NOTE maintenance personnel, ‘¢ Major alarm: The ESM needs to be maintained immediately ‘© Minor alarm: The ESM does not require maintenance, but sends a reminder to remote ‘© Blinking at iong intervals: on for 1s and then off for 1s ‘© Blinking at short intervals: on for 0.125s and then off for 0.1255 ‘© Allindicators blinking: The ESM has entered the maintenance mode. ESM in sleep mode: The fault indicator is off except for reverse-connection protection. Communications ports Figure 3-86 RJ45 pins UMS female connector issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Utd 36 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3. Components Table 3-74 Pin definitions of communications ports 45 Pin | Signal | Description Remark 1 S485 T+ | RS485 transmission + | Four-wire RS485 - communications, complying 2 Rs485 T-_| RS485 transmission - | with the Modbus protocol 3 NC Reserved 4 S485 Rt | RS485 reception + 5 S485 R-_ | RS485 reception - 6 NC Reserved : 7 ANH Positive terminal for | Used to report alarms to a CAN communications _ | monitoring unit and exchange data between 8 CANL Negative terminal for | Esvis connected in parallel, CAN communications DO1 and DO2 Ports Table 3-75 DO1 and DO2 port definitions Cell voltage sampling fa converter output short ci oil short-circuit, charge temperature protection, protection, power modul number conflict, input/o discharge overcurrent loi temperature sampling fault, charge sitk | Definition _| Description Alarm Status Screen DO1 | Fault, major _| If the ESM raises one of the Configurable alarm following alarms, the dry contact _| (If the dry supplies an alarm signal: contact is, ult, cell closed, an alarm is ircut, relay | fePorted by low default.) discharge low temperature protection, charge high temperature protection, discharge high temperature le internal overtemperature protection, discharge converter output short circuit, input reverse connection, BMU anti-theft lock, overload lockout due to component failure, serial number conflict, serial utput discharge overvoltage lockout, and ckout issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Ita. 7 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3 Components Sitk | Definition _| Description Alarm Status Screen 02 | Overload If the ESM raises one of the warning, following alarms, the dry contact overdischarge | supplies an alarm signal: Protection Discharge undervoltage alarm, discharge undervoltage protection, and discharge overcurrent warning Activation and Startup ‘An ESM can be activated in three modes. After being activated, the ESM switches from the sleep mode to disconnected mode. ‘* Activation through the PWR terminal: supply 43.2-58 V DC power to the PWR terminal on the ESM panel for at least 5s. ‘© Activation through the MANUAL ON/OFF button: hold down the MANUAL ON/OFF button on the ESM panel for at least 5s and less than 15s. © Activation through the power port: supply a DC voltage of 43.2-58 V to the power terminal on the front panel for at least 5s, CO note 1. The MANUAL ON/OFF button isa contact button. The interval for pressing the button should be greater than 0.5s; otherwise, the operation is ineffective 2. Ifyou have forcibly powered off the battery that isin charging, discharging, of disconnected moce by pressing the MANUAL ON/OFF button, the ESM can be only reactivated by pressing and holding this button Technical Specifications Table 3-76 Technical specifications Item Specifications Dimensions (WxD | © 442 mm x 396 mm x 130 mm (excluding mounting xH) ears) #482 mm x 396 mm x 130 mm (including mounting ears) Weight 44 kg Installation mode _| Installed in a 19-inch rack Maintenance mode | Maintained from the front Humidity 5%-95% Altitude 10-4000 m (When the altitude ranges from 2000 m to 4000 m, the highest operating temperature decreases by 1°C for each additional 200 m.) issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Utd 8 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3. Components Item Specifications Ripple and noise | s 200 mV IP rating 1P40 Other requirements Indoor scenario: © There is no conductive dust, corrosive gas, or explosion hazard. ‘© Dust, corrosive substances, pests, molds, and other indicators should be controlled in accordance with class 3.1 requirements in ETSI EN 300 019-1-3 (V2.3.2 ora later version) Outdoor scenario: © There is no conductive dust, corrosive gas, or explosion hazard. ‘© Dust, corrosive substances, pests, molds, and other indicators should be controlled in accordance with class 4.1 requirements in ETS! EN 300 019-1-4 (V2.2.1), 3.3.2 Lithium Battery ESM-48100A8 Appearance Figure 3-87 ESM-48100A8 Figure 3-88 Panel and ports issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Utd 35 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3. Components Table 3-77 Port pin definitions No. [Silk Screen | Item Description 1 [eno Protective ground | M6 screw 2 |vor ESM dry contact | Alarm output dry contact; po2 output configurable (if the dry contact is ‘open, an alarm is reported by default). For details, see Table 3-79. 3 COM_IN Communications 1. Used for information reporting port and communication 4 COM_OUT Ce cascading munication: ~ Po | 2. Use R45 terminals and provide the 1000 A surge protection capability. For details, see Table 3-78 5 [RUN Run indicator For the diagram, seeFigure 3-90Figure 3-90 ALM Alarm indicator For details about functions, see cHG Charge indicator _| Table 3-80. DCHG Discharge indicator soc SOC indicator 6 MANUAL Button for manual | A contact button used for ON/OFF power-on/off manual power-on/off and maintenance. For details, seeActivation and Startup 7 |pwe ESMU port for The ESM can be activated if the connecting to an _| PWR port is supplied with a external power —_| voltage of 43.2-58 V. For detalls, source seeActivation and Startup. 8 + ESM positive Positive and negative ports of the terminal ESM. Secured by M6 screws. Appropriate OT terminals should - ESM negative be used. The required torque is terminal 45-5.5 N-m and the recommended cable size is 25, mr, If the ESM is used at a temperature below 45°C, the cable size can be smaller but should be at least 16 mm?. issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Ita. 705 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual Figure 3-89 R145 pins RJ45 Female Table 3-78 Pin definitions of communications ports 3. Components RJ45 Pin nal Remark 1 5485 T+ | R485 transmission + |» Four-wire RS4B5 communication, 2 5485 7 __| RS485 transmission ~ Sr Mth the Madbus protocol 3 Ne Reserved Mado proto 4 5485 Rr | RS485 reception + protocol 5 seas | S485 reception = | * Sava: 9600 6 Ne Reserved - 7 CANH Positive terminal for CAN | Used to report alarms communications toa monitoring unit and exchange data 3 CAN Negative terminal for | pac ochange CAN communications connected in parallel. issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Utd To isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3. Components DO1 and DO2 Ports Table 3-79 DO1 and DO2 port definitions silk Screen Definition Description Alarm Status Dot Fault, major alarm If the ESM raises one of the following alarms, the dry contact supplies an alarm signal: Cell voltage sampling fault, straight- through short-circuit fault, straight- through open-circuit fault, cell fault, reverse-connection protection, internal temperature protection, cell temperature sampling fault, charge low temperature protection, charge high temperature protection, charge overcurrent protection, discharge low temperature protection, discharge high temperature protection, discharge overcurrent protection, serial number conflict, and discharge overcurrent lockout Do2 Overload warning, overdischarge protection If the ESM raises one of the following alarms, the dry contact, supplies an alarm signal: Battery group discharge ndervoltage protection, single cell discharge undervoltage protection, cell low voltage disconnection protection, battery group discharge Undervoltage alarm, cell discharge undervoltage alarm, and discharge overcurrent alarm Configurable (ifthe dry contact is ‘open, an alarm is reported by default.) LED Indicator Figure 3-90 LED indicator issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Ita. 702 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual Table 3-80 LED indicator description 3. Components sitk | Item Screen Color Description RUN | Run indicator | Green Steady on: Communication is normal (including board startup, self-check, software loading, and board power-on when not loaded: excluding sleep When the power port or PWR port is energized). (Off: The ESM is shut down or hibernating. Blinking at long intervals: The LUI is querying data. Blinking at short intervals: ‘Communication is interrupted. ALM | Fault Red indicator Steady on: There is a fault or major alarm. Off: There is no fault or major alarm. CHG | Charge Green indicator ‘Steady on: The ESM is being charged. Off: The ESM is open-circuited or discharging. DCHG | Discharge indicator Green Steady on: The ESM is discharging. Off: The ESM is open-circuited or being charged. issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Id. 703 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3 Components sitk | ttem Color Description Screen soc | soc Green 1, 024% capacity Indicators 25% indicator: blinking * Other SOC indicators: off 2. 25%-49% capacity 25% indicator: steady on © 50% indicator: blinking © Other SOC indicators: off 3, 50%-74% capacity © 25% indicator: steady on © 50% indicator: steady on 75% indicator: blinking Other SOC indicators: off 4, 75%-99% capacity 25% indicator: steady on © 50% indicator: steady on 75% indicator: steady on © 100% indicator: blinking 5. 100% capacity # The four SOC indicators are steady on, Notes: ‘© Major alarm: The ESM needs to be maintained immediately. Minor alarm: The ESM does not require maintenance, but sends a reminder to remote maintenance personnel, = Blinking at long intervals: on for 1s and then off for 1 = Blinking at short intervals: on for 0.125s and then off for 0.1255 = SOC indicator off and other indicators blinking: The ESM has entered the maintenance mode. ~ ESM in sleep mode: The fault indicator is off except for reverse-connection protection. Activation and Startup ‘An ESM can be activated in three modes. After being activated, the ESM switches from the sleep mode to disconnected mode. ‘Activation through the PWR terminal: supply 43.2-58 V DC power to the PWR terminal on the ESM panel for at least 5s. ‘Activation through the MANUAL ON/OFF button: hold down the MANUAL ON/OFF button on the ESM panel for at least 5s and less than 15s. issue 04 (2022-10-1 5) Copyright © Huawei Technologies Co, Id. 708 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 3 Components ‘¢ Activation through the power port: supply a DC voltage of 432-58 V to the power terminal on the front panel for at least 5s. CO Note 1. The MANUAL ON/OFF button isa contact button, The interval for pressing the button should be greater than 015s; otherwise, the operation is ineffective 2, Ifyou have forcibly powered off the battery that isin charging, discharging, of disconnecteé moce by pressing the MANUAL ON/OFF button, the ESM can be only reactivated by pressing and holding this button, Technical Specifications Table 3-81 Technical specifications Item Specifications Dimensions (WxD | © 442 mm x 396 mm x 130 mm (excluding mounting xH) ears) ‘© 482 mm x 396 mm x 130 mm (including mounting ears) Weight 48 kg Installation mode _| Installed in 2 19-inch rack Maintenance mode | Maintained from the front Humidity 56-95% Altitude 04000 m (When the altitude ranges from 2000 m to 4000 m, the highest operating temperature decreases by 1°C for each additional 200 m.) Ripple and noise | < 200 mv IP rating 140 Other requirements | Indoor scenario: ‘© There is no conductive dust, corrosive gas, or explosion hazard. ‘© Dust, corrosive substances, pests, molds, and other indicators should be controlled in accordance with class 3.1 requirements in ETS! EN 300 019-1-3 (V2.3.2 ora later version) Outdoor scenario: ‘© There is no conductive dust, corrosive gas, or explosion hazard. ‘© Dust, corrosive substances, pests, molds, and other indicators should be controlled in accordance with class 4.1 requirements in ETS! EN 300 019-1-4 (2.2.1), issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Utd 105 isitePower Integrated Smart Site (ICC1000-A1-E1) User Manual 4 Maintenance 4 Maintenance 4.1 Routine Maintenance Maintenance personnel perform routine maintenance periodically based on site requirements. The recommended interval is six months. If any fault is detected, rectify it in a timely manner. For details about the maintenance and troubleshooting of lithium batteries, see the corresponding lithium battery manuals. For details about how to maintain and troubleshoot AC / DC blade power supplies, see the blade manual, feud ‘© Do not maintain devices on raining days; otherwise, water may enter and damage devices. ‘© By default, the air conditioner is started when the door is open. If the air conditioner is set to stop when the door is open, you are advised to open the front and rear doors to prevent overheating on the side that is not open during device operation. 4.1.1 Cabinet Table 4-1 Cabinet maintenance No. _| Maintenance Item Possible Cause Suggestion 1 | Check whether the cabinet | The cabinet is scratched. _| Repaint the cabinet. paint is flaking off or there are scratches on the cabinet surface 2 | Check whether the cabinet | The envionment quality of | Evaluate the risk and is rusty or corroded the equipment room is poor. | improve the environment of the equipment room. issue 04 (2022-10-15) Copyright © Huawei Technologies Co, Ita. 706

You might also like