Super Trace Analysis: ME-MS61L ME-MS41L ME-MS41W
Super Trace Analysis: ME-MS61L ME-MS41L ME-MS41W
ALS Methods
ME-MS61L ™
Super Trace Analysis
Improved Detection Limits for Key
ME-MS41L ™ Pathfinders.
ME-MS41W ™ Continued improvement in instrumentation and sample
introduction systems providing the Lowest Detection Limits
(LDL) in the industry for near-total four acid and partial
ALS continues to improve detection limits in
our industry leading super trace ICP-MS digestion methods.
methods. Both the four acid and aqua regia Improved Detection Limits
digestion methods have reduced detection
Previous LDL New LDL Improvement
limits for key elements of interest to Method Analyte
ppm ppm factor
exploration geologists as shown in the
adjacent table. As 0.05 0.02 2.5
0.009
ME-MS61L
0.008 ME-MS61L NEW
0.007
0.006
Re-ppm
0.005
0.004
0.003
0.002
0.001
Sample
The applied improvements are displayed in the Increased confidence of exploration geochemical
graphs adjacent for Se, Re and Te. data at low concentrations with improved precision
of low-level Se in sample duplicates.
The lower detection limits produce data sets with a
substantially lower proportion of results below
ME-MS41L NEW ME-MS41L
detection and decrease the effect of binning at
lower concentrations. The proportion of the Re
results above detection, in this case improved from
25% to nearly 90%, and the binning of low values
was substantially reduced. The latest reduction in 0.3
detection limits for Re, Te and Se have pushed the
Se Duplicate (ppm)
detection limits for this method below the upper
crustal abundance for these elements.
Our super trace packages provide robust results at
levels well below the lowest regional backgrounds
for most elements; allowing an unprecedented level
of detail in major and trace element geochemistry
on every sample. Importantly, detection limits are
below regional background for key pathfinders like
Tl, Sb, Te, Cd, Se, Re, and As, allowing clear definition 0.03
of anomalous patterns and trends. 0.03 0.3
Se Original (ppm)
Th Se Sr
Pb Cu Ni
La
Both digestions are available for standard soils Sc
Sn
0.1 Co As Li
Rb
and sediments, as well as with our clay separation W Cs Mo
Nb Y Ga Ge Be
technique. The Super Trace method has been U
Sb
Au Tl Ce
optimised for long-term ICP-MS signal stability, in 0.01 Na%
Hf
Hg
Ca%
Al%
Bi Ag Ta K%
particular for samples with very high Ca content. Fe%
Cd Te
In
Mg%
Ti% S%
Aqua regia is a partial digestion method that is
useful for identifying anomalism through cover and 0.001 Re P%
Mn
ability to provide a full pathfinder element
suite as well as a cost-effective proxy for
Zn
1 Se V Cr
mineralogy.
ME-MS61 Detection Limits (ppm)
La Pb Zr
Sr
In addition to the traditional mapping of base metal Cu
As Ni Li
Sn
Hf
and trace element anomalies, major element results 0.1 Co W
Nb
Y
Sc
U
Rb
Mo
across an entire drill program can be used in Te Cs
Ta
Be
Sb
Ge
Ga
Ecuador — Quito
T: +593 2 513 0891
ALS provides a wide range of specialised testing services E: alsgeo.quito@ALSGlobal.com