PRODUCT CONFIGURATION

1 PRODUCT IDENTIFIER:
QSE = Electro-Magnetic Flowmeter
2 TURBINE SIZE:
05 = 1/2” (15 mm) 20 = 2” (50 mm)
07 = 3/4” (20 mm) 30 = 3” (80 mm) (Flange Only)
10 = 1” (25 mm) 40 = 4” (100 mm) (Flange Only)
15 = 1-1/2” (40 mm)
3 FITTING:
NPT = NPT (Male) (½” to 2” Only)
BSP = BSPP (Male) (ISO 228) (½” to 2” Only)
FAP = ANSI Flange - Polymer (3” & 4” Only)
4 ELECTRONIC CHOICE:
Q9 = 2-Button Integral Display with 2 Totals (Batch Total =
Resettable, Total = Non-Resettable) and Rate of Flow. Also
provides a Scaled Pulse Output (NPN Open Collector).

QSE MAG FLOWMETER 42 = 2-Button Integral Display with 2 Totals (Batch Total =
Resettable, Total = Non-Resettable) and Rate of Flow. Also
The FLOMEC® QSE Mag Series is a dependable highly accurate provides 4-20 mA Output and Scaled Pulse Output (NPN Open
electromagnetic flowmeter designed for flow and usage monitoring Collector).
in commercial applications, such as wastewater that is dumped QB = Integral Pulse Transmitter, Unscaled Pulse Output (NPN
into a city sewer system. Open Collector)
The NorylTM housing and flow tube offer a lightweight, easy-to-in- 5 COMMUNICATION CHOICE:
stall Mag Meter that is resistant to heat and compatible with many Q1 = QSI Module: Bluetooth®, Pulse Output (Flow or Energy
water-based liquid solutions. When installing to metal pipe, it is and Scalable), RS485 (Modbus RTU or BACnet® MS/TP),
recommended to use flexible expansion joints on one or both Temperature Inputs, BTU Calculator, Energy Use Computation.
ends to eliminate any stresses that might be incurred from Note: Energy Use Computation Requires Temperature Sensor
misaligned rigid metal piping. Probes (Probes Must be Customer Supplied). No Local Display
Option.
The QSE Mag Meter monitors flow rate and total flow in a wide
variety of applications including: HVAC, Turf/ Irrigation and other Q2 = QSI Module: Bluetooth®, Pulse Output (Flow or Energy
water reclamation applications. and Scalable), Temperature Inputs, BTU (Heat) Calculator,
Energy Use Computation. Note: Energy Use Computation
Requires Temperature Sensor Probes (Probes Must be
FEATURES / BENEFITS Customer Supplied). No Local Display Option.
• Low investment and operating costs Q3 = QSI Module: Bluetooth®, Pulse Output (Scalable), 4-20mA.
No Local Display Option.
• ± 0.5% Accuracy of Reading (from 0.25 fps to 15 fps [0.08
to 4.6 m/s]) XX = No Communication Suite. Required for Q9 and 42
Electronic Choice.
• Wide turndown ratio of 60:1
6 TEMPERATURE SENSOR PROBES:
• Non-intrusive, no moving parts to wear out, low mainte-
nance and repair cost, tolerates high flows without damage X = No Temperature Probes

• The slightly modified bore permits unobstructed flow, mini- 7 PACKAGING:


mizes flow disturbances and straight pipe requirements A = 1/2" - 2" Meters with Q9 or QB Electronics Choice
• Seven line sizes (½” to 4”) ½”, ¾”, 1”, 1-½”, 2”, 3", and 4” 1/2", 3/4" and 1" Meters with 42 Electronics Choice
B = 3" Meter
• Housing ported with “Thermal Well Supports” for sensors C = 4" Meter
(Energy Management) D = 1-1/2" and 2" Meters with 42 Electronics Choice
• Compatible with FLOMEC Q9 Electronics Display or
FLOMEC QSI I/O Board

1 2 3 4 5 6 7
>>>> QSE 30 FAP Q9 XX X B
SPECIFICATIONS
Fitting Operating Temperature 32o F to 180o F (0o C to 82o C)
NPT, BSPP, ANSI Flanged
Type: Range:
1/2” to 2” - NPT (Male), BSPP (Male) (ISO 228) Ambient Temperature Range: 0o F to 140o F (-18o C to 60o C)
3” and 4” 150# ANSI Flanged - Polymer Flange Typical 1/2” (05) 4347 PPG (1148.4 Pulses/L)
Recommeded Plastic K-Factor:
25 ft.-lbs. (33.9 N∙m) 3/4” (07) 1937 PPG (511.7 Pulses/L)
Flange Bolt Torque:
1” (10) 1089 PPG (287.7 Pulses/L)
Pipe Sizes: 1/2”, 3/4”, 1”, 1-1/2”, 2”, 3”, 4”
1-1/2” (15) 484.1 PPG (127.9 Pulses/L)
Pressure Rating: 150 psi @ 70o F (10.3 bar @ 21o C)
2” (20) 400 PPG (105.7 Pulses/L)
Velocity: 0.25 to 15 fps (0.08 to 4.6 m/s)
3” (30) 121 PPG (32.0 Pulses/L)
Flow: 1/2” (05) 0.167 - 10 GPM (0.632 - 37.85 L/min)
4” (40) 68.1 PPG (18.0 Pulses/L)
3/4” (07) 0.33 - 20 GPM (1.25 - 75.71 L/min)
Power Externally Powered
1” (10) 0.67 - 40 GPM (2.54 - 151.42 L/min) Supply:
Voltage Supply (Min): 12V (dc)
1-1/2” (15) 1.33 - 80 GPM (5.03 - 302.83 L/min)
Voltage Supply (Max): 36V (dc)
2” (20) 2.5 - 150 GPM (9.46 - 567.81 L/min)
Consump- Max current consumption (QSE with QSB): 75mA
3” (30) 5 - 300 GPM (18.93 - 1135.62 L/min) tion:
Max current consumption (QSE with QSI): 150mA
4” (40) 10 - 600 GPM (37.85 - 2271.25 L/min)
Wetted Body NorylTM
Accuracy Materials:
Electrodes 316L SS
±0.5% of Reading between 0.25 fps and 15 fps (0.08 m/s and 4.6 m/s)
(Reference Owner's Manual for complete accuracy and Seals EPDM O-Rings
uncertainty specifications) Output
Frequency All Sizes 10 Hz Minimum - 1,000 Hz Maximum
Range:
Calibration Report: N.I.S.T. Certification Available

APPLICATIONS • BAS (Building Automation


Systems)
• Chilled water
• Waste Water Monitoring
• Domestic water (hot and CERTIFICATIONS
• Agriculture Irrigation cold)
• Turf Irrigation Systems • Energy sub-metering
• Micro Irrigation Systems (BTU hot and cold) IP67
• EMS (Energy Management • OEM Water Treatment Skids
Systems) • Cooling Tower Bleed-Off
• Reclaimed (Recycled) Water
• Greywater
Temperature °C
21.1 Derated Pressure Curve for QSE (Pressure vs Temperature)
26.7
32.2 Derated Pressure
37.8 160.0 11.0
43.3
48.9
140.0 9.7
54.4
60.0
65.6 120.0 8.3
71.1
76.7
82.2 100.0 6.9
87.8
Pressure PSIG

Pressure bar

93.3
80.0 5.5
98.9

60.0 4.1

40.0 2.8

20.0 1.4

0.0 0.0
50 70 90 110 130 150 170 190 210
(10) (21) (32) (43) (54) (66) (77) (88) (99)

Temperature °F (°C)

Service & Warranty: For technical assistance, warranty replacement or repair contact your
FLOMEC® or GPI® distributor: In North or South America: 888-996-3837 / FLOMECmeters.com
Outside North or South America: +61 2 9540 4433 / FLOMECmeters.com
© 2022 Great Plains Industries, Inc. All Rights Reserved. IND-1060-QSE Rev C 01/2023

© 2022 Great Plains Industries, Inc. All Rights Reserved.