Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 8

Methode Zenz Othmer

FOR EDUCATIONAL PURPOSE ONLY – DO NOT USE THIS METHOD FOR DETAIL DESIGN – ALWAYS CONSULT A RE

This calculation method is only valid in DILUTE PHASE


Inputs

Type of conveying
Material to be conveyed
Solids conveying rate 1000 kg/h
Pipeline material
Conveying line configuration
Pipe inside diameter 0.5 m
Gas used for conveying
Molecular weight gas
Gas inlet temperature
Gas viscosity 1.80E-05 Pa.s

Inlet gas density 1.185413247784 kg/m3

Blower 12000 Nm3/h


15480 kg/h
Gas flowrate at inlet 13058.737135711 m3/h
18.474333917209 m/s
Gas inlet velocity 18.474333917209 m/s
Solids velocity
Gas mass flowrate
Solids Loading Ratio
Solids friction factor
Pipe line roughness
epsilon / D
Reynolds

Fanning friction factor


1/f^0.5
Colebrook (Moody) friction factor
Actual fanning friction factor
Guess-Actual

Approximate method, DO NOT USE


Solids slip factor
FOR DETAIL DESIGN. ALWAYS
CONSULT A REPUTABLE
COMPANY
Page 1
Approximate method, DO NOT USE
Methode
FOR ZenzDESIGN.
DETAIL Othmer ALWAYS
CONSULT A REPUTABLE
Pressure drop calculated 0.86 Psi
COMPANY
If you spot a mistake or wish to suggest an improvement, please contact admin@powderprocess.net

Copyright www.PowderProcess.net

The content of PowderProcess.net is copyrighted but no warranty nor liability is ensured. The content of this site is to be seen as a help and important information and calculation m
organization or by checking another source. The user must always respect all applicable regulation. The use of the information is at the user an

FOR EDUCATIONAL PURPOSE ONLY – DO NOT USE THIS METHOD FOR DETAIL DESIGN – ALWAYS CONSULT A RE

Page 2
Methode Zenz Othmer
L DESIGN – ALWAYS CONSULT A REPUTABLE SUPPLIER FOR DETAIL DESIGN

ILUTE PHASE

Orientation – Please only


Horizontal, Vertical,
Horizontal to Vertical,
Section Pipe line Vertical to Horizontal,
Vacuum - number component Horizontal to Horizontal
Test - 1 Pipe Horizontal
2205 lb/h 2 Pipe Horizontal
Stainless Steel 3 Pipe Horizontal
See table 4 Pipe Horizontal
19.7 inch 1.633858 ft 5 Pipe Horizontal
Air 6 Pipe Horizontal
29 g/mol 7 Pipe Horizontal
25 °c 8 Pipe Horizontal
1.21E-05 lb/ft.s 9 90 bend Horizontal to Vertical
10 Pipe Vertical
0.07400293153 lb/ft3 11 Pipe Vertical
12 Pipe Vertical
13 Pipe Vertical
14 90 bend Vertical to horizontal
15 Pipe Horizontal
16 Pipe Horizontal
17 Pipe Horizontal
60.5958152484 ft/s 18 Pipe Horizontal
48.4766521988 ft/s 19 90 bend Horizontal to Horizontal
33846.4168732 lb/h 20 Pipe Horizontal
0.065147221
1.2 Template limited to 20 pipe sections, please extend if necessary
0.05 mm
0.0001
6.06E+05

0.00592
8.18E+00
0.01492924073
0.00373231018
0.00219 Use Goal Seek to bring to 0

0.8

Page 3
Methode Zenz Othmer
0.06 bar

min@powderprocess.net

be seen as a help and important information and calculation must always be double checked by the user through the quality procedure of his
licable regulation. The use of the information is at the user and its organization own risk and own cost.

L DESIGN – ALWAYS CONSULT A REPUTABLE SUPPLIER FOR DETAIL DESIGN

0.00354219317

Page 4
Methode Zenz Othmer

Layout

Length Length Inside diameter Inside diameter Section equivalent length

m ft m in ft
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 20
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 20
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 10
3.05 10.004 0.102 4.02 20
3.05 10.004 0.102 4.02 10

ase extend if necessary Note : refer to powderprocess.net website for equivalent len

Page 5
Methode Zenz Othmer

Pressure drop cal


Cumulative equivalent
length Pressure drop components Psi

Solids
Section Flow of accelerati Flow of Elevation Elevation
ft number gas on solids of gas of solids Misc
10 1 0.021 0.073 0.002 0.000 0.000
20 2 0.021 0.000 0.002 0.000 0.000
30 3 0.021 0.000 0.002 0.000 0.000
40 4 0.021 0.000 0.002 0.000 0.000
50 5 0.021 0.000 0.002 0.000 0.000
60 6 0.021 0.000 0.002 0.000 0.000
70 7 0.021 0.000 0.002 0.000 0.000
80 8 0.021 0.000 0.002 0.000 0.000
100 9 0.042 0.000 0.003 0.000 0.000
110 10 0.021 0.000 0.002 0.005 0.010
120 11 0.021 0.000 0.002 0.005 0.010
130 12 0.021 0.000 0.002 0.005 0.010
140 13 0.021 0.000 0.002 0.005 0.010
160 14 0.043 0.000 0.003 0.000 0.000
170 15 0.021 0.000 0.002 0.000 0.000
180 16 0.022 0.000 0.002 0.000 0.000
190 17 0.022 0.000 0.002 0.000 0.000
200 18 0.022 0.000 0.002 0.000 0.000
220 19 0.043 0.000 0.003 0.000 0.000
230 20 0.022 0.000 0.002 0.000 0.000 0.2

derprocess.net website for equivalent length of pipes and fittings

Page 6
Methode Zenz Othmer

Pressure drop calculation

Total
pressure Gas Gas
drop in temperatu temperatu Inlet gas Outlet gas Inlet Outlet Inlet gas
section re inlet re outlet density density pressure pressure velocity Outlet gas velocity
0.095128 25 25 0.074 0.074 14.700 14.605 60.60 60.99
0.022987 25 25 0.074 0.073 14.605 14.582 60.99 61.08
0.022669 25 25 0.073 0.073 14.582 14.559 61.08 61.18
0.022702 25 25 0.073 0.073 14.559 14.537 61.18 61.27
0.022738 25 25 0.073 0.073 14.537 14.514 61.27 61.37
0.022774 25 25 0.073 0.073 14.514 14.491 61.37 61.47
0.02281 25 25 0.073 0.073 14.491 14.468 61.47 61.56
0.022847 25 25 0.073 0.073 14.468 14.445 61.56 61.66
0.04565 25 25 0.073 0.072 14.445 14.400 61.66 61.86
0.037898 25 25 0.072 0.072 14.400 14.362 61.86 62.02
0.037881 25 25 0.072 0.072 14.362 14.324 62.02 62.18
0.037903 25 25 0.072 0.072 14.324 14.286 62.18 62.35
0.037926 25 25 0.072 0.072 14.286 14.248 62.35 62.51
0.046362 25 25 0.072 0.071 14.248 14.202 62.51 62.72
0.023402 25 25 0.071 0.071 14.202 14.178 62.72 62.82
0.023319 25 25 0.071 0.071 14.178 14.155 62.82 62.93
0.023358 25 25 0.071 0.071 14.155 14.132 62.93 63.03
0.023397 25 25 0.071 0.071 14.132 14.108 63.03 63.13
0.046746 25 25 0.071 0.071 14.108 14.062 63.13 63.34
0.22364 25 25 0.071 0.070 14.062 13.838 63.34 64.37
0.862137 Assumed equal to inlet

Page 7
Methode Zenz Othmer

0.095128
0.118115
0.140784
0.163486
0.186225
0.208999
0.231809
0.254656
0.300306
0.338204
0.376084
0.413988
0.451914
0.498276
0.521678
0.544997
0.568355
0.591752
0.638498
0.862137

Page 8

You might also like