Data Sheet

SRMV, SRMAC
Single Relay Module

Single Relay Module

Description Features
The Single Relay Module enables a controller output signal to • SRMV converts a 10 Vdc analogue output signal to a 8 A relay output
drive a single changeover relay. This allows plant of up to 8A • SRMAC converts a 24 Vac (triac) output signal to a 10 A relay output
at 240 Vac resistive to be switched by the relay contacts. The • Can be mounted on a DIN rail or any flat surface
module may either be mounted on a DIN rail or on a flat surface.
There are two versions: the SRMV accepts a 0 to 10 V signal,
and the SRMAC accepts a 0 to 24 Vac signal (e.g. triac output).

Physical
coil terminals
relay contact termnals
11 C O N C
A2 coil A1
15.5 mm
(0.61”)

NO 14

12

75.5 mm (2.97”)
42 mm (1.65”)

SRMV, SRMAC Data Sheet 91-0617 Issue 5/D 18/06/07 1


Data Sheet
IQ241
Controller

IQ241 Controller

Description Features
The IQ241 controllers are of medium capacity designed for the • 1 second cycle time.
control of all types of building plant. They can provide a minimum of • Optional integral/external Display Panel.
12 digital inputs, and 8 analogue voltage outputs. A further 20 I/O • Access to entire network by way of local supervisor
points can be made available by using up to 10 S cards, each connection.
providing 2 inputs or outputs of the same type (8 input only, 12 input • Facility for mounting an additional node controller.
or output). S cards can provide analogue current, analogue voltage, • High capacity DDC with PID control loops.
thermistor, or digital inputs, or analogue voltage outputs giving the • Stand alone or integrated system operation.
IQ241 sufficient capability for more complex strategies. It can • 12 digital inputs.
operate either as a stand alone device or as part of a Building • 8 analogue voltage outputs.
Management System. A standard Display Panel can be mounted • 10 slots for S cards (20 I/O points)
on the front cover, or externally. The IQ241 also has the facility to
connect any IQ system supervisor or Engineering Tool to the
network without a separate node controller.

Physical
230 Vac Input Power Knockouts for M20 cable gland
Knockout for RDS connector
Knockout for additional node RS232
(3.35”)
85 mm

24 V Input Power

I/O LEDs
325 mm
(12.8”)

S card fittings
under flap
V
1 3 5 7 9 1 1 1 3 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 3 1 3 3 3 5 3 7 3 9
2 4 6 1 0 1 2 1 4 1 6 1 2 0 2 2 2 4 2 6 2 3 0 3 2 3 4 3 6 3 4 0

LEDs TX RX

Channel identification label


1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0
I1 d ig ita l in p u ts I1 2 I1 3 I2 0 I2 1 I3 2
S 1 a n a lo g u e in p u ts S 8 S 9 S 1 5
L 2 0 L 9 L 8 a n a lo g u e o u tp u ts L 1

LAN 1 C 3 C 5 C 7 C 9 C 11 C 13 C 15 C 17 C 19 C 21 C 23 C 25 C 27 C 29 C 31 C 33 C 35 C 37 C 39 C AUX
24v
2 C 4 C 6 C 8 C 10 C 12 C 14 C 16 C 18 C 20 C 22 C 24 C 26 C 28 C 30 C 32 C 34 C 36 C 38 C 40 C + - + -

Network connectors
Supervisor
I/O connectors port

Earthing (grounding)bar 355 mm (13.98”) Auxiliary supply

IQ241 Controller Data Sheet TA103013 Issue 2, 4/03/2009 1