Professional Documents
Culture Documents
Catalog Agregate 2011 06001
Catalog Agregate 2011 06001
com
condensing
Brazil
Rui Barbosa, 1020 - P.O. BOX 91
89219-901 - Joinville - SC - Brazil
Phone: +55 47 3441-2121
Fax: +55 47 3441-2780
Units
Via Buttigliera 6
10020 - Riva Presso Chieri (Torino) - Italy
P.O. BOX 151 - 10023 Chieri (TO)
Phone: +39 011 943-7111
Fax: +39 011 946-8377
+39 011 946-9950
Italy
Subject to alteration without previous notice. - Code 06001 - Date May 2008 - Version 00.
Europe - Sales Office
Zona Industriale D1 - Via Fratelli Gambino, 7
10023 - Chieri (Torino) - Italy
Phone: +39 011 940-5611
Fax: +39 011 940-5656
R 134a
Fax: +42 153 417-2299
Slovakia
R 404A
R 22
México - Sales Office
Torre Alestra, Piso 3 - Office 373
Av. Lázaro Cárdenas 2321 Pte.
2800 Vista Ridge Drive NE P.O. BOX 66260 - San Pedro Garza García
Suwanee, GA 30024-3510 Nuevo León - México
Phone: +1 678 804-1337 Phone: +52 81 1001-7102
Fax: +1 678 804-1338 Fax: +52 81 1001-7142
U.S.A.
29 Yuhua Road
Area B of Beijing Tianzhu Airport Industrial Zone
101312 - Beijing - China
Phone: +86 10 8048-2255
Fax: +86 10 6725-6825
China
www.embraco.com
c o o l i n g s o l u t i o n s
Embraco is participating in the United Nations Global Compact.
Index
Page
1 - General 02
2 - Features and Benefits 02
3 - Technical Instructions / Installation Precautions 02
3.1 - General Information 02
3.2 - Basic Installation - Overview 02
3.3 - Installation Steps 03
3.4 - Cleaning the System 03
3.5 - Recommendations for Brazing (welding) the System 03
3.6 - Leakage Detection 03
3.7 - System Evacuation 04
3.8 - Procedures for Refrigerant Charge 04
3.9 - Piping 04
3.10 - Basic Accessories of a Cooling System 05
3.11 - Electrical Connections 05
Cross Reference 07
R 134a M/HBP 07
R 22 M/HBP 08
R 404A LBP 09
R 404A M/HBP 09
Performances Tables 10
60 Hz
R 134a - HBP 10
R 134a - L/MBP 10
R 22 - HBP 12
R 404A - M/HBP 14
R 404A - LBP 14
50 Hz
R 134a - HBP 16
R 134a - L/MBP 16
R 22 - HBP 16
R 404A - LBP 18
Accessories 20
Valves Operation 22
Nomenclature 23
1
Condensing Unit
1) - General High Horse Power Units (from 1 to 5 HP)
Low Back Pressure: from -30°F (-34ºC) to +10°F (-12ºC) 3.1) - General Information
Inspect the unit for any damage that may have occurred during
shipping. If damage is present, report to the carrier immediately.
To prevent loss, check in the box for any lose bag accessories,
which may not be attached to the unit.
2) - Features and Benefits
Only store, transport or install the condensing units in the proper
All Units position (right side up).
• Complete line from 1/6 to 5 HP Warning: Make sure you have read and understand all
• Units available for R 134a, R 22, R 404A procedures and caution messages before you
and R 12 replacement refrigerants execute any maintenance or installation tasks!
It is imperative – for your own safety - that the
• 100% factory tested
testing devices used are functioning well and
• Reliable, quiet and efficient hermetic compressors properly sized.
• Corrosion resistant materials
• Oversized aluminum fin, copper tube condenser, capable
of operating under high ambient temperatures and pressures 3.2) - Basic Installation – Overview
• UL approved The installation site shall be well ventilated, ensuring that there
• Customizable design (external casing, accessories) will be sufficient air flow behind the condenser (refer to figure 1).
• Low maintenance
2
18°F (5°C and 10°C). Superheating at the compressor’s
inlet must be between 18°F and 27°F (10°C and 15°C)
(for this case, the difference between the temperature at
the surface of the return pipe, at a distance 6" (150 mm)
from the compressor, and the evaporation temperature.
The sub-cooling in the condenser shall be between
5°F and 18°F (3°C and 10°C), i.e., the condensing
temperature less the temperature at the pipe's surface at
the condenser's outlet.
* Evaporation temperature obtained by converting the suction
pressure into temperature.
It is important that all items are monitored according to the
installation manual, for proper functioning of the condensing
Figure 1 – Natural air flow through the roof unit (and, consequently, of the Cooling System). Therefore,
reading the manual is very important to properly install and
operate the equipment.
If the air flow to the condenser is restricted (even partly blocked),
the performance of the system can be drastically reduced.
3.4) - Cleaning the System
Embraco Condensing Units are designed to operate under
room temperature up to 110°F (43°C). Therefore, make sure Cleaning the system before installing a new condensing
that the temperature at the installation site does not exceed the unit is mandatory to completely remove residues and other
recommended limit. contaminants.
Attention: You must clean the condenser periodically, The cleaning procedure for an installation process may be
so that no particles will impair or block air carried out by flushing the system with R 141b*.
circulation. Embraco recommends the installation of a filter-dryer at the
suction line during the cleaner operation to retain and filter
any undesired particles.
3.3) - Installation Steps
* Do not release R 141b or other harmfull substances
3.3.1 - Select and size the equipment needed to assemble to the atmosfere.
the refrigeration system, according to the project
specifications (piping, valves, accessories, condenser unit).
Carefully observe the application range for each model. 3.5) - Recommendations for Brazing
(welding) the System
3.3.2 - Start by soldering the piping. After you have soldered
the piping connections to the condensing unit and Circulate nitrogen (N2) through the pipes, with an internal
evaporator, perform the leak tests in all brazed or pressure from 1 to 2 psig, to prevent oxidation and to avoid
threaded joints. scales from forming, ensuring that the piping is free from any
contaminants (oil, grease, oxides).
3.3.3 - Start to evacuate the entire system (refer to item 3.7).
Use a damp cloth when welding the valves, fittings and pipes, to
3.3.4 - Charge the refrigerant, preferably in liquid form,
prevent overheating the components through heat propagation.
according to the required cooling gas mass (lb).
(Refer to item 3.8). The compressor and the filter-dryer are extremely susceptible to
humidity. As such, they shall only be opened during installation,
3.3.5 - Switch the condensing unit on and access the system,
leaving them exposed to air for a maximum of 10 minutes to
monitoring the low and high pressures, temperature
open air.
of the suction and liquid lines. Complete the cooler
load if necessary.
3.3.6 - When the temperature inside the cooling system 3.6) - Leakage Detection
(chamber, conditioned environment) approaches the
During the system leakage tests, never pressurize the pipes
project value, proceed with the final adjustments, setting
using air, oxygen or acetylene. There is a potential risk of fire
the system for continuous operation at full load.
and/or explosion.
3.3.7 - The superheating at the evaporator (given by the
After the installation is finished, pressurize the system to
difference between temperatures at the piping surface at
100 psig (never use pressures higher than 150 psig, so as not to
the point where the expansion valve's bulb is fixed, and
damage the low pressure switch), using nitrogen and/or a small
the evaporation temperature*) shall be between 9°F and
refrigerant charge.
3
Condensing Unit
3.8) - Procedures for Refrigerant Charge
soap bubbles
The refrigerant shall only be charged after the proper vacuum has
been achieved. Please check on the compressor or condensing
unit tag what is the type of refrigerant that should be used to
charge the system. Break the vacuum only when the compressor
is switched off.
It is recommended that the refrigerant charge be provided in the
liquid state (with the compressor switched off), through the high
side (tank liquid valve) and by the refrigerant mass measurement
(lb), according to the system specification.
Wait for 15 minutes before switching on the system again, so as
Figure 2 – Leakage tests with soap bubbles to allow the gas to be evenly distributed and balance the pressure
levels.
Check for leaks using an electronic detector or a halide The fine tuning of the refrigerant charge must be done while the
detector (torch). An alternative method is to check leakage system is running (compressor switched on), by observing the
with soap bubbles. When all fittings are properly installed, sight glass. The charge will be complete when there are no more
depressurize the system and go to the next step. bubbles forming.
When performing a condensing unit replacement always check
the specified refrigerant charge.
3.7) - System Evacuation
Warning: Never use the compressor itself to evacuate
the system, nor energize the system when it is 3.9) - Piping
under vacuum, as it may cause the compressor
Piping shall be sized so that:
to short-circuit.
3.9.1 - It is flexible, so as to avoid rupture due to expansion
To evacuate the system, use a high vacuum pump and a vacuum
and due to the transmission of vibration usually caused
gage. The system shall be evacuated up to 200(m) Hg or less.
by compressors.
In any case, at least 20 minutes of vacuum must be applied.
3.9.2 - Ensure that the refrigerant is well distributed through the
vacuum gage evaporator(s), and prevent the liquid from flowing back
to the compressor. To do that, use an expansion valve
with proper dimensions, and an inverted siphon at the
outlet of each evaporator.
falling angle
N2 118 inches
vacuum pump
condensing unit
suction line
liquid line
Figure 3 – High Vacuum Pump to evacuate the system evaporator
4
3.9.3 - Prevent the liquid from flowing back to the compressor • Systems with more than one evaporator
when the system stops and the evaporator(s) is/are
• High refrigerant charges
located above the Condensing Unit, using an inverted
siphon and suction accumulator. • Operations with defrosting by hot gas
3.9.4 - Aid the return of lubricating oil coming from the • Where the distance from the compressor to the evaporator is
evaporator(s) to the system where the Condensing Unit over 50 feet (15 meters)
is located over 118 inches above the evaporator(s), using
• Evaporator(s) above the condensing unit
an inverted siphon every 118 inches in the piping.
3.9.5 - Allow secondary operations, such as attaching 3.10.6 - Oil Separator
measurement instruments, isolating stretches for
It is installed at the discharge line, when the evaporator is below
maintenance purposes and pump down.
the compressor's height (long distances).
Warning: The diameter of the fittings for the condensing
units and evaporators shall not be used as a 3.10.7 - Suction Filter
parameter to select the diameters of the other
It is recommended to clean the systems if the compressor has
system components.
burned out. Installed at the suction line, its main task is to retain
Attention: After replacement the condensing unit and the contaminants (result of the burning of the compressor), and
it’s accessories must be handled and recycled to retain system particles.
according to the material group (ferrous,
non-ferrous, polymers, oils, ...) directives. 3.10.8 - Crankcase Heater
These recomendations are intended to minimize
the adverse impacts on the environment. Its main function is to vaporize any liquid refrigerant present
in the compressor. The liquid refrigerant can jeopardize the
compressor’s lubrication and cause liquid slug. It is employed
in systems that operate with high refrigerant charges, low
3.10) - Basic Accessories of a Cooling System
evaporation temperature (below 0°F (-17.7°C)), defrost by hot
gas or under low ambient-temperatures.
3.10.1 - Filter-Dryer
Installed at the liquid line, its function is to retain particles and Warning: After a long period without the condensing unit
mainly remove residual humidity from the system. being switched on, the crankcase heater must
be powered for at least 12 hours prior to the
3.10.2 - Sight Glass compressor start up. During normal operation,
the heater shall be permanently powered.
It is installed at the liquid line, just after the filter-dryer and used
to monitor the system refrigerant charge. Some models also
allow humidity detection. 3.10.9 - High/Low Pressure Switch
Some of Embraco Condensing Units are fitted with High / Low
3.10.3 - Solenoid Valve
Pressure Switches. Their function is to prevent the compressor
It is installed at the liquid line, prior to the expansion valve and from operating under pressure levels that are outside of their
used for the pump down procedure. application range.
5
Condensing Unit
Follow the instructions and make the proper connections as depicted in the wiring diagram of each model.
A1
K1
shared pole or PTC A2
fan C
fan
start relay
comp
comp
A1
K1
A2
C brown
C
blue black
fan
comp
In case a starting capacitor is needed, the connection may be made Compressors applied without an Run capacitor use PTC
between terminals 3 and 4 (11 and 13 when the condensing unit with 1 terminal.
use EG/F compressor), just by breaking this jumper.
MOTOR TYPE
F = Fuse CR = Run capacitor CSIR - Capacitive Start Inductive Run RSIR - Resistence Start Inductive Run
C = Fan capacitor K1 = Contact switch _[]_ = Thermal protector CSR - Capacitive Start and Run 3Ph - Three Phase
CS = Start capacitor A1/A2 = Contact coil PSC - Permanent Split Capacitor
6
Cross Reference
R 134a M/HBP* - Btu/h
TECUMSEH DANFOSS COPELAND
RANGE
Capacity Model Capacity Model Capacity Model Capacity Model
0 - 1.000 930 AEA3414
1.409 UM55HHR 1240 AEA3417 1007 UCGC0017RW 1150 M2FH0017
1.000 - 2.000 1.552 UM65HHR 1620 AEA3425 1860 UCGC0020RW 1330 M2FH0020
1.663 UM65HNR 1940 AEA4430 1810 M2FH0024
2.272 UF10HBX 2560 AEA4440 2095 UCGC0025RW 2080 M2FH0026
2.000 - 3.000 2.541 UNE6210Z 2717 UCGC0033RW 2710 M2FHA033
2.576 UNE6187Z
3.208 UFU130HAX 3180 AEA4448 3600 M2FHA049
3.000 - 4.000
3.263 UFI12HBX
4.002 UT6213ZA 4000 AKA4460 4264 UCGC0050RW 4630 M2FH0056
4.000 - 5.000 4.359 UT6217E 4250 AKA7437
4.540 UT6215Z 4900 AKA4476
5700 AJA4492 5009 HCGC0055RW 5450 FTAHA074
5.000 - 6.000 5510 FTAHA075
5780 FTAHA074
6.168 UJ6220Z 6600 AJA7465 6370 FTAMA074
6.000 - 7.000
6790 FTAHA100
* 25oF (-4oC) Evaporating temperature / 90oF (32oC) Ambient temperature. Other models upon request.
7
Condensing Unit
R 22 M/HBP* - Btu/h
* 25oF (-4oC) Evaporating temperature / 90oF (32oC) Ambient temperature. Other models upon request.
8
R 404A LBP* - Btu/h
TECUMSEH DANFOSS COPELAND
RANGE
Capacity Model Capacity Model Capacity Model Capacity Model
1000 AEA2410 764 UCHC0020RW 1440 M4FL0033
1340 AEA2413 1303 UCHC0025RW
0 - 2.000
1577 UCHC0033RW
1959 UCHC0050RW
2330 UT2155GK- 2180 AKA2422 2941 LCHC0060RW 2120 M4FL0040
2528 UNE2134GK 2890 AJA2429 3460 LCHC0075RW 2250 VJAL050Z
2.000 - 4.000
3644 UT2178GK 2550 M4FL0051
3520 M4FL0067
4314 UJ2192GK 4838 AWA2448 5329 LCHC0100RW 4180 FJAFA075
4527 UNJ2192GK 4580 FJALA100
4.000 - 6.000 4527 UL63B652 4850 FJALA101
4950 FJALA103
5090 FJALA102
6380 UJ2212GK 6450 AWA2464 6768 LCHC0150UW
6.000 - 8.000
6380 UNJ2212GK 7871 AWA2479
9044 UL63B752 8790 AWA2490 8770 LCHC0200UW 8110 FJALA0250
8.000 - 10.000 9999 AVA2510 9010 FJALB200
9440 FJALA225
10.000 - 12.000 11606 UL63A113 11851 AVA2512
12.000 - 14.000 13600 VJAL025Z
14475 AVA2515 14844 LCHC0300UW 14430 FJALB301
14.000 - 16.000
15450 VJAL035Z
16.000 - 18.000
18.000 - 20.000 18551 UL63A183 19984 LGHC0400UW 18950 VJAL040Z
* -10oF (-23.3oC) Evaporating temperature / 90oF (32oC) Ambient temperature. Other models upon request.
1/6 UM55HHR 115V 60Hz RSIR 889 1167 1651 1825 2150 250 2.85 2333
1/6 UM65HHR 115V 60Hz CSIR 1090 1430 1674 2224 2600 305 3.45 2821
1/3+ UNE6187Z 115V 60Hz CSIR 1691 2344 2808 3846 4371 616 7.06 4937
1/2- UNE6210Z 115V 60Hz CSIR 1762 2321 2761 3935 4989 683 7.56 5552
1/2+ UT6213ZA 115V 60Hz CSIR 2954 3734 4269 5409 5892 892 10.30 6393
3/4 UT6215Z 115V 60Hz / 100V 50Hz CSIR 3323 4232 4848 6154 6704 1022 12.10 7218
3/4 UT6215ZC 115V 60Hz CSIR 3323 4232 4848 6154 6704 1022 12.10 7218
3/4- UT6217E 115V 60Hz CSIR 2777 3941 4777 6660 7683 1054 11.18 7421
1 UJ6220Z 115V 60Hz CSR 4531 5743 6592 8415 9115 1330 13.08 9937
*MCA - Minimum Circuit Amps | MFS - Maximum Fuse Size | LRA - Locked Rotor Amps
1/6 UM65HNR 115V 60Hz CSIR 365 536 706 186 3.00 933 1159 1433 1893
1/4 UF10HBX 115V 60Hz CSIR 270 675 960 255 4.40 1226 1571 2020 2524
1/3+ UFI12HBX 115V 60Hz CSIR 520 909 1297 321 5.40 1726 2250 2869 3540
1/3+ UFI12HBX 115V 60Hz CSIR 541 792 1362 352 5.41 1643 2218 2893 3634
1/3+ UFI12HBX 220V 60Hz CSIR 560 798 1362 352 2.88 1652 2209 2859 3568
1/3+ UFU130HAX 115-127V 60Hz CSIR 1245 1271 1430 313 4.40 1861 2147 2778 3638
*MCA - Minimum Circuit Amps | MFS - Maximum Fuse Size | LRA - Locked Rotor Amps
10
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
4.56 7.41 23.00 8.94 10.00 18.50 44.09 247 8 28 16 - 3/8 3/8 UM55HHR
5.31 8.76 26.00 9.57 11.81 12.72 45.19 247 8 28 16 - 3/8 3/8 UM65HHR
9.83 16.89 29.00 11.42 15.55 18.50 59.52 530 10 28 16 - 3/8 3/8 UNE6187Z
10.45 18.01 37.50 11.42 15.55 18.50 59.52 530 10 28 16 - 3/8 3/8 UNE6210Z
13.88 24.18 36.00 11.42 15.55 18.50 61.73 530 10 28 16 - 5/16 1/4 UT6213ZA
16.10 28.20 45.00 11.69 15.55 18.50 61.73 530 10 28 16 - 5/16 1/4 UT6215Z
16.13 28.23 45.00 11.69 15.55 18.50 61.73 530 10 28 16 - 5/16 1/4 UT6215ZC
14.98 26.16 51.00 11.42 15.55 18.50 61.73 530 10 28 16 - 5/16 1/4 UT6217E
17.35 30.43 70.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UJ6220Z
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
4.75 7.75 26.00 9.57 11.81 12.72 45.19 247 8 28 16 - 3/8 3/8 UM65HNR
6.50 10.90 35.00 8.94 10.00 18.50 45.19 247 8 30 5 - 3/8 3/8 UF10HBX
7.75 13.15 43.00 8.94 10.00 18.50 45.19 247 8 30 5 - 3/8 3/8 UFI12HBX
7.80 13.20 43.00 11.57 14.25 16.54 36.38 530 10 28 13 - 5/16 1/4 UFI12HBX
4.60 7.50 26.50 11.57 14.25 16.54 36.38 530 10 28 13 - 5/16 1/4 UFI12HBX
6.50 10.90 40.30 11.57 14.25 16.54 36.38 530 10 28 13 - 5/16 1/4 UFU130HAX
11
R 22 - HBP - 60Hz
Performance / Evaporating Temperature oF - ASHRAE
Check Point Data 45oF (7.2oC)
Voltage Motor 10oF 20oF 30oF 40oF 50oF
HP Model Consumption
Type (-12oC) (-6oC) (-1oC) (4oC) Capacity (10oC)
Power Current
V / Hz Btu/h Btu/h Btu/h Btu/h Btu/h W A Btu/h
1/3 UNE6181E 115V 60Hz CSIR 1619 2205 2622 3547 3994 505 6.03 3726
1/2 UNE6195E 115V 60Hz CSIR 1889 2451 2895 3884 4416 572 6.43 4905
3/4+ UT6220E 115V 60Hz / 100V 50Hz CSR 3407 3976 4733 6700 8538 1253 11.80 9468
3/4+ UT6220E 208-230V 60Hz / 200V 50Hz CSR 3407 3976 4733 6700 8538 1253 6.20 9468
1 UJ9226E 230V 60Hz CSR 4970 6504 7597 10052 12146 1440 6.91 4774
1 UJ9232E 208-230V 60Hz / 200V 50Hz CSR 8603 10429 11731 14554 15795 1720 7.90 17052
1 UJ9232E 208-230V 60Hz / 200V 50Hz CSR 8603 10429 11731 14554 15795 1720 7.90 17052
1 UH23B153 208-230V 60Hz CSR 8603 10429 11731 14554 15795 1450 6.40 17052
1 1/2 UH23B193 208-230V 60Hz CSR 8034 10767 12580 16379 18872 1990 9.03 19643
1 1/2 UH23B20Q 208-230V 60Hz / 200-220V 50Hz 3Ph 8435 11306 13209 17197 19445 2025 7.33 20627
2 UH23B243 208-230V 60Hz CSR 10869 13955 15943 20051 23165 2610 12.83 24604
2 UH23B243 208-230V 60Hz / 200-220V 50Hz 3Ph 11086 14234 16356 20839 23602 2450 8.13 25096
2 1/2 UH23B30Q 208-230V 60Hz / 200-220V 50Hz 3Ph 17532 17532 18904 23150 29389 3100 10.85 30080
2 1/2 UH23B303 208-230V 60Hz CSR 17881 17881 19281 23613 29956 2990 14.85 30683
2 1/2 UH23A323 460V 60Hz / 380-415V 50Hz 3Ph 12815 16849 19473 24925 30355 3060 6.15 30989
3 UH23A383 208-230V 60Hz CSR 15139 19455 23207 31962 37859 3690 18.55 42767
3 UH23A383 208-230V 60Hz / 200-220V 50Hz 3Ph 15139 19455 23207 31962 37859 3650 11.95 42767
3 UH23A383 460V 60Hz / 380-415V 50Hz 3Ph 15139 19455 23207 31962 37859 3650 7.05 42767
3 1/2 UH23A423 208-230V 60Hz CSR 14750 21100 25929 36673 42057 4060 20.36 47568
3 1/2 UH23A423 208-230V 60Hz / 200-220V 50Hz 3Ph 14750 21100 25929 36673 42057 4040 13.36 47568
3 1/2 UH23A423 460V 60Hz / 380-415V 50Hz 3Ph 14750 21100 25929 36673 42057 4040 7.36 47568
4 1/2 UH23A543 200-230V 60Hz / 200-220V 50Hz 3Ph 22561 29999 35399 47189 53339 5270 16.16 59830
4 1/2 UH23A543 460V 60Hz / 380-415V 50Hz 3Ph 22561 29999 35399 47189 53339 5270 9.16 59830
5 UH23A623 200-230V 60Hz / 200-220V 50Hz 3Ph 28956 38255 43939 55379 60714 5990 20.10 66926
5 UH23A623 460V 60Hz / 380-415V 50Hz 3Ph 28956 38255 43939 55379 60714 5990 11.90 66926
*MCA - Minimum Circuit Amps | MFS - Maximum Fuse Size | LRA - Locked Rotor Amps
12
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
Blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
8.54 14.57 34.60 11.42 15.55 18.50 59.52 530 10 28 16 - 3/8 3/8 UNE6181E
9.04 15.47 29.00 11.42 15.55 18.50 59.52 530 10 28 16 - 3/8 3/8 UNE6195E
15.80 27.60 46.00 11.30 15.55 18.50 49.16 530 10 28 16 - 3/8 3/8 UT6220E
8.80 15.00 30.00 11.30 15.55 18.50 49.16 530 10 28 16 - 3/8 3/8 UT6220E
9.64 16.55 27.50 13.27 16.54 18.90 79.37 530 10 28 16 - 5/8 1/4 UJ9226E
10.90 18.80 42.50 15.20 27.56 21.65 99.21 1059 10 28 2x16 - 3/8 3/8 UJ9232E
10.90 18.80 42.50 13.38 17.91 24.21 77.16 824 12 22 25 5.1 1/2 3/8 UJ9232E
8.55 14.95 45.00 13.38 17.91 24.21 77.16 824 12 22 25 5.1 1/2 3/8 UH23B153
12.10 21.10 57.00 16.14 19.49 24.21 154.32 1883 14 - 135 7.90 5/8 3/8 UH23B193
10.00 17.30 48.00 16.14 19.49 24.21 154.32 1883 14 - 135 7.90 5/8 3/8 UH23B20Q
17.70 30.50 66.00 19.09 33.46 25.20 165.35 3178 14 - 2x135 7.90 1/2 3/8 UH23B243
11.80 20.00 48.00 19.09 33.46 25.20 165.35 3178 14 - 2x135 7.90 5/8 3/8 UH23B243
15.20 26.10 67.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 7.90 3/4 3/8 UH23B30Q
20.20 35.10 82.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 7.90 3/4 3/8 UH23B303
9.30 15.50 30.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 7.90 3/4 3/8 UH23A323
24.80 43.40 97.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 7.90 7/8 3/8 UH23A383
16.60 28.50 78.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 7.90 3/4 3/8 UH23A383
10.50 17.50 39.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 7.90 3/4 3/8 UH23A383
27.10 47.50 110.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 14.20 7/8 3/8 UH23A423
18.40 31.70 78.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 14.20 7/8 3/8 UH23A423
10.90 18.20 39.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 14.20 7/8 3/8 UH23A423
23.30 39.50 106.00 26.18 45.28 28.74 253.57 5003 18 - 2x230 14.20 7/8 1/2 UH23A543
14.60 23.70 53.00 26.18 45.28 28.74 253.57 5003 18 - 2x230 14.20 3/4 1/2 UH23A543
28.20 48.30 124.00 26.18 45.28 28.74 253.57 5003 18 - 2x230 14.20 7/8 1/2 UH23A623
18.00 29.90 62.00 26.18 45.28 28.74 253.57 5003 18 - 2x230 14.20 7/8 1/2 UH23A623
13
R 404A - M/HBP - 60Hz
Performance / Evaporating Temperature oF - ASHRAE
Check Point Data 45oF (7.2oC)
Voltage Motor -5oF 0oF 10oF 20oF 30oF 40oF 50oF
HP Model Consumption
Type (-20oC) (-18oC) (-12oC) (-6oC) (-1oC) (4oC) Capacity (10oC)
Power Current
V / Hz Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h Btu/h W A Btu/h
1/2- UNE6181GK 115V 60Hz CSIR 1432 1616 2223 2953 3659 4941 5047 582 7.20 5511
1/2- UNE6195GK 115V 60Hz CSIR 1442 1640 2257 2987 3683 4501 5115 565 7.90 5592
1/3+ UNE6210GK 208-230V 60Hz CSIR 1770 2002 2684 3318 3806 4269 4532 652 3.80 4754
1/2 UNE9213GK 115V 60Hz CSR 2349 2520 3192 4150 4900 5562 5937 1218 9.70 6230
2/3- UT6217GK 115V 60Hz CSR 2523 2909 4014 5006 5736 6233 6786 1283 14.30 7066
2/3- UT6217GK 208-230V 60Hz CSIR 2523 2909 4014 5006 5736 6233 6786 1283 7.33 7066
3/4+ UT6220GK 115V 60Hz CSR 3417 3816 5030 6278 7342 8436 9149 1331 16.50 9776
3/4+ UT6220GK 208-230V 60Hz CSR 3417 3816 5030 6278 7342 8436 9149 1134 7.90 9776
1- UT6222GK 115V 60Hz CSR 4457 4760 5773 6411 7437 8934 10230 1426 17.10 10960
1- UT6222GK 208-230V 60Hz CSR 4457 4760 5773 6411 7437 8934 10230 1426 9.50 10960
1 1/6 U(N)J9226GK 208-230V 60Hz CSR 5190 5494 6629 7795 9480 11539 13129 1432 9.70 14302
1 1/6 U(N)J9226GK 208-230V 60Hz CSR 5190 5494 6629 7795 9480 11539 13129 1432 9.10 14302
*MCA - Minimum Circuit Amps | MFS - Maximum Fuse Size | LRA - Locked Rotor Amps
1/2 UNE2134GK 115V 60Hz CSIR 1491 1998 2528 580 7.60 3146 3691
1- UT2178GK 115V 60Hz CSR 1711 2672 3644 815 7.74 4880 6236
1- UT2178GK 230V 60Hz CSR 1711 2672 3644 815 2.79 4880 6236
1 UJ2192GK 115V 60Hz CSR 2448 3356 4314 1175 7.00 5395 6581
1 UJ2192GK 230V 60Hz CSR 2448 3356 4314 1175 4.90 5395 6581
1 UNJ2192GK 208-230V 60Hz CSR 2448 3356 4527 1007 4.90 6206 8032
1 UL63B652 208-230V 60Hz CSR 2448 3356 4527 1340 5.80 6206 8032
1 1/2 UJ2212GK 230V 60Hz CSR 3521 4923 6380 1370 7.10 7981 9710
1 1/4 UNJ2212GK 115V 60Hz CSR 3521 4923 6380 1370 13.82 7981 9710
1 1/4 UNJ2212GK 230V 60Hz CSR 3521 4923 6380 1370 7.10 7981 9710
2 UL63B752 208-230V 60Hz CSR 4288 6220 9044 1790 3.90 10221 11466
2 UL63B752 208-230V 60Hz 3Ph 4288 6220 9044 1790 3.90 10221 11466
2 UL63B752 460V 60Hz / 380-415V 50Hz 3Ph 4288 6220 9044 1790 3.90 10221 11466
3 UL63A113 200-230V 60Hz / 200-220V 50Hz 3Ph 6680 8003 11606 2230 6.39 14125 15209
3 UL63A113 208-230V 60Hz CSR 6680 8003 11606 2359 12.13 14125 15209
3 UL63A113 460V 60Hz / 380-415V 50Hz 3Ph 6652 8010 11606 2270 4.13 14125 15209
4 UL63A183 200-230V 60Hz / 200-220V 50Hz 3Ph 8303 13550 18551 3625 11.35 20283 22873
4 UL63A183 208-230V 60Hz CSR 8303 13550 18551 3645 17.15 20283 22873
4 UL63A183 460V 60Hz / 380-415V 50Hz 3Ph 8303 13550 18551 3570 6.55 20283 22873
*MCA - Minimum Circuit Amps | MFS - Maximum Fuse Size | LRA - Locked Rotor Amps
14
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
Blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
10.00 17.20 34.60 11.65 13.39 18.31 44.10 218 10.00 28 16 1.90 3/8 1/4 UNE6181GK
10.87 18.77 29.00 11.65 13.39 18.31 44.10 218 10.00 28 16 1.90 3/8 1/4 UNE6195GK
5.75 9.55 16.80 11.65 13.39 18.31 45.20 218 10.00 28 16 2.10 3/8 1/4 UNE6210GK
13.12 22.82 33.60 11.65 13.39 19.88 45.80 218 10.00 28 16 2.50 3/8 1/4 UNE9213GK
19.87 34.17 57.00 12.76 16.14 19.49 39.90 412 10.83 31 34 4.40 1/2 3/8 UT6217GK
10.16 17.49 30.00 12.76 16.14 19.49 39.90 412 10.83 31 25 4.40 1/2 3/8 UT6217GK
21.62 38.12 57.00 12.76 16.14 19.49 70.90 530 10.83 31 25 4.40 1/2 3/8 UT6220GK
10.87 18.77 30.00 12.76 16.14 19.49 70.90 530 10.83 31 25 4.40 1/2 3/8 UT6220GK
23.37 40.47 71.00 12.76 16.14 19.49 76.50 530 10.83 31 34 4.40 1/2 3/8 UT6222GK
12.87 22.37 34.00 12.76 16.14 19.49 76.50 530 10.83 31 25 4.40 1/2 3/8 UT6222GK
14.12 23.82 34.00 15.35 16.14 19.96 82.70 577 11.81 28 34 4.40 5/8 3/8 U(N)J9226GK
12.37 21.47 34.00 12.72 24.09 17.32 88.20 824 10.00 28 2x16 4.40 5/8 3/8 U(N)J9226GK
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
Blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
10.70 18.50 51.80 11.42 15.55 18.50 74.96 530 10 28 16 - 3/8 3/8 UT2155GK-
10.50 18.10 33.00 11.42 15.55 18.50 59.52 530 10 28 16 - 3/8 1/4 UNE2134GK
10.68 18.41 72.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UT2178GK
4.49 7.28 32.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UT2178GK
9.75 16.75 87.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UJ2192GK
9.75 16.75 40.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UJ2192GK
6.68 11.58 40.00 13.39 17.91 24.21 77.16 824 12 22 25 4.40 1/2 3/8 UNJ2192GK
7.80 13.60 56.60 13.39 17.91 24.21 77.16 824 12 22 25 4.40 1/2 3/8 UL63B652
9.88 16.98 40.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UJ2212GK
18.28 32.09 87.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UNJ2212GK
9.88 16.98 40.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UNJ2212GK
5.71 9.61 55.00 16.14 19.49 24.21 154.32 1883 14 - 135 6.80 3/4 3/8 UL63B752
5.71 9.61 48.00 16.14 19.49 24.21 154.32 1883 14 - 135 6.80 3/4 3/8 UL63B752
5.71 9.61 24.00 16.14 19.49 24.21 154.32 1883 14 - 135 6.80 3/4 3/8 UL63B752
9.60 16.00 50.00 19.09 33.46 25.20 165.35 3178 14 - 2x135 6.80 3/4 3/8 UL63A113
16.80 29.00 65.00 19.09 33.46 25.20 165.35 3178 14 - 2x135 6.80 3/4 3/8 UL63A113
6.80 11.00 30.00 19.09 33.46 25.20 165.35 3178 14 - 2x135 6.80 3/4 3/8 UL63A113
15.80 27.20 78.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 6.80 3/4 3/8 UL63A183
23.10 40.20 110.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 6.80 3/4 3/8 UL63A183
9.80 16.40 39.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 6.80 3/4 3/8 UL63A183
15
R 134a - HBP - 50Hz
Performance / Evaporating Temperature oF - ASHRAE
Check Point Data 45oF (7.2oC)
Voltage Motor 10oF 20oF 30oF 40oF 50oF
HP Model Consumption
Type (-12oC) (-6oC) (-1oC) (4oC) Capacity (10oC)
Power Current
V / Hz Btu/h Btu/h Btu/h Btu/h Btu/h W A Btu/h
1/2 - UNE6210Z 220V 50Hz CSIR 1699 2312 2754 3738 4243 553 3.14 4778
1/2+ UT6215Z 220V 50Hz CSIR 2265 3191 3849 5322 6068 815 4.94 6873
*MCA - Minimum Circuit Amps | MFS - Maximum Fuse Size | LRA - Locked Rotor Amps
R 22 - HBP - 50Hz
Performance / Evaporating Temperature oF - ASHRAE
Check Point Data 45oF (7.2oC)
Voltage Motor 10oF 20oF 30oF 40oF 50oF
HP Model Consumption
Type (-12oC) (-6oC) (-1oC) (4oC) Capacity (10oC)
Power Current
V / Hz Btu/h Btu/h Btu/h Btu/h Btu/h W A Btu/h
1 1/2 UH23B20Q 200-230V 60Hz / 200-220V 50Hz 3Ph 6683 8996 11199 13643 15028 1910 7.68 16381
2 UH23B243 200-230V 60Hz / 200-220V 50Hz 3Ph 9048 11964 14187 17306 19329 2130 8.08 20929
2 1/2 UH23B30Q 200-230V 60Hz / 200-220V 50Hz 3Ph 10734 13568 17040 20171 22075 2905 10.8 25084
2 1/2 UH23A323 460V 60Hz / 380-415V 50Hz 3Ph 11060 13976 17556 20778 22741 2825 5.4 25842
3 UH23A383 200-230V 60Hz / 200-220V 50Hz 3Ph 13330 15830 21703 27346 30149 3385 11.8 35663
3 UH23A383 460V 60Hz / 380-415V 50Hz 3Ph 13330 15830 21703 27346 30149 3295 6.3 35663
3 1/2 UH23A423 200-230V 60Hz / 200-220V 50Hz 3Ph 13103 17445 23580 30901 35173 3650 12.36 39667
3 1/2 UH23A423 460V 60Hz / 380-415V 50Hz 3Ph 13103 17445 23580 30901 35173 3690 6.96 39667
4 UH23A543 200-230V 60Hz / 200-220V 50Hz 3Ph 19084 24881 31921 39640 44078 4840 16.26 49894
4 UH23A543 460V 60Hz / 380-415V 50Hz 3Ph 19084 24881 31921 39640 44078 4700 8.36 49894
5 UH23A623 200-230V 60Hz / 200-220V 50Hz 3Ph 23802 32001 39092 45882 50052 5590 20.2 55806
5 UH23A623 460V 60Hz / 380-415V 50Hz 3Ph 23802 32001 39092 45882 50052 5490 10.4 55806
*MCA - Minimum Circuit Amps | MFS - Maximum Fuse Size | LRA - Locked Rotor Amps
16
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
Blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
4.93 8.07 23.80 11.42 15.55 18.50 59.52 530 10 28 16 - 3/8 3/8 UNE6210Z
7.18 12.12 21.00 11.69 15.55 18.50 61.73 530 10 28 16 - 5/16 1/4 UT6215Z
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
Blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
3.45 5.41 20.00 8.94 10.00 18.50 45.19 247 8 30 5 - 3/8 3/8 UFI12HBK
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
Blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
10.18 17.86 48.00 16.14 19.49 24.21 154.32 1883 14 - 135 7.90 5/8 3/8 UH23B20Q
10.68 18.76 48.00 19.09 33.46 25.20 165.35 3178 14 - 2x135 7.90 1/2 3/8 UH23B243
14.60 25.40 67.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 7.90 3/4 3/8 UH23B30Q
7.85 13.25 30.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 7.90 3/4 3/8 UH23A323
15.85 27.65 82.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 7.90 7/8 3/8 UH23A383
8.98 15.28 39.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 7.90 3/4 3/8 UH23A383
16.61 28.97 82.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 14.20 7/8 3/8 UH23A423
9.86 16.82 39.00 19.09 33.46 25.20 209.47 3178 14 - 2x135 14.20 7/8 3/8 UH23A423
21.48 37.74 106.00 26.18 45.28 28.74 253.57 5003 18 - 2x230 14.20 7/8 1/2 UH23A543
11.61 19.97 53.00 26.18 45.28 28.74 253.57 5003 18 - 2x230 14.20 3/4 1/2 UH23A543
27.45 47.65 124.00 26.18 45.28 28.74 253.57 5003 18 - 2x230 14.20 7/8 1/2 UH23A623
15.20 25.60 62.00 26.18 45.28 28.74 253.57 5003 18 - 2x230 14.20 7/8 1/2 UH23A623
17
R 404A - LBP - 50Hz
Performance / Evaporating Temperature oF - ASHRAE
Check Point Data -10oF (-23.3oC)
Voltage Motor -30oF -20oF 0oF 10oF
HP Model Consumption
Type (-34oC) (-29oC) Capacity (-18oC) (-12oC)
Power Current
V / Hz Btu/h Btu/h Btu/h W A Btu/h Btu/h
1/2+ UT2155GK- 220V 50Hz CSIR 813 1404 2003 495 3.55 2847 3804
1/2 UNE2134GK 220V 50Hz CSIR 1191 1637 2088 483 3.20 2635 3123
1- UT2178GK 220V 50Hz CSR 1429 2267 3112 678 3.16 4175 5337
1 UJ2192GK 220V 50Hz CSR 1836 2934 4120 920 4.18 5397 6845
1 1/2 UJ2212GK 220V 50Hz CSR 2259 3776 5150 1150 5.62 7368 9628
1 1/2 UNJ2212GK 220V 50Hz CSR 2288 3783 5150 1150 5.62 7370 9654
2 UL63B752 200-230V 60Hz / 200-220V 50Hz 3Ph 3028 5004 6982 1280 5.40 8623 9472
2 UL63B752 460V 60Hz / 380-415V 50Hz 3Ph 3028 5004 6982 1280 2.70 8623 9472
3 UL63A113 220-240V 50Hz CSR 5567 6669 9672 1864 9.28 11770 12674
3 UL63A113 460V 60Hz / 380-415V 50Hz 3Ph 5574 6672 9672 1667 3.68 11774 12678
4 UL63A183 220-240V 50Hz CSR 6918 11292 15459 2921 15.00 16903 19062
4 UL63A183 460V 60Hz / 380-415V 50Hz 3Ph 6918 11292 15459 2916 5.80 16903 19062
*MCA - Minimum Circuit Amps | MFS - Maximum Fuse Size | LRA - Locked Rotor Amps
18
Fan
Angle Connecting Port
MCA* MFS* LRA* Height Width Length Weight Blade Rated Receiver
Air Flow of (inch) Model
(diameter) Output LBs
Blades
A A A inch inch inch lb ft3/min inch o
W Suction Liquid
5.44 8.99 18.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UT2155GK-
5.00 8.20 16.40 11.42 15.55 18.50 59.52 530 10 28 16 - 3/8 1/4 UNE2134GK
4.95 8.11 22.80 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UT2178GK
6.23 10.41 26.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UJ2192GK
8.03 13.65 36.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UJ2212GK
8.03 13.65 36.00 13.27 16.54 18.90 74.96 530 10 28 16 - 3/8 3/8 UNJ2212GK
7.33 12.73 48.00 16.14 19.49 24.21 154.32 1883 14 - 135 6.80 3/4 3/8 UL63B752
3.96 6.66 24.00 16.14 19.49 24.21 154.32 1883 14 - 135 6.80 3/4 3/8 UL63B752
12.20 21.50 60.00 19.09 33.46 25.20 165.35 3178 14 28 2x135 6.80 3/4 3/8 UL63A113
5.18 8.86 30.00 19.09 33.46 25.20 165.35 3178 14 - 2x135 6.80 3/4 3/8 UL63A113
19.90 34.90 104.00 19.09 33.46 25.20 187.39 3178 14 28 2x135 6.80 3/4 3/8 UL63A183
8.35 14.15 39.00 19.09 33.46 25.20 187.39 3178 14 - 2x135 6.80 3/4 3/8 UL63A183
19
Accessories
High Low
Nominal Liquid Suction Crankcase Pressure Pressure Fan Cycling
CU Model # Volt / Hz / Phase Base Valve
Power Receiver Accumulator Heater Control Control Control
Switch Switch
UM55HHR 1/6 115 / 60 / 1 ST OP ST NA OP OP NA
UM65HHR 1/6 115 / 60 / 1 ST OP ST NA OP OP NA
UNE6187Z 1/3+ 115 / 60 / 1 ST NA ST NA NA NA NA
UNE6210Z 1/2- 115 / 60 / 1 ST NA ST NA NA NA NA
UT6213ZA 1/2+ 115 / 60 / 1 ST NA ST NA NA NA NA
115 / 60 / 1
UT6215Z 3/4 ST NA ST NA NA NA NA
100 / 50 / 1
UT6215ZC 3/4 115 / 60 / 1 ST NA ST NA NA NA NA
UT6217E 3/4- 115 / 60 / 1 ST NA ST NA NA NA NA
R 134a UJ6220Z 1 115 / 60 / 1 ST NA ST NA NA NA NA
UM65HNR 1/6 115 / 60 / 1 ST OP ST NA OP OP NA
UF10HBX 1/4 115 / 60 / 1 ST OP ST NA OP OP NA
UFI12HBX 1/3+ 115 / 60 / 1 ST OP ST NA OP OP NA
UFI12HBX 1/3+ 220 / 60 / 1 ST OP ST NA OP OP NA
UFU130HAX 1/3+ 115-127 / 60 / 1 ST OP ST NA OP OP NA
UNE6210Z 1/2- 220 / 50 / 1 ST OP ST NA OP OP NA
UT6215Z 1/2+ 220 / 50 / 1 ST OP ST NA OP OP NA
UFI12HBK 1/3+ 220 / 50 / 1 ST OP ST NA OP OP NA
High Low
Nominal Liquid Suction Crankcase Pressure Pressure Fan Cycling
CU Model # Volt / Hz / Phase Base Valve
Power Receiver Accumulator Heater Control Control Control
Switch Switch
UNE6181E 1/3 115 / 60 / 1 ST NA ST NA NA NA NA
UNE6195E 1/2 115 / 60 / 1 ST NA ST NA NA NA NA
115 / 60 / 1
UT6220E 3/4+ ST NA ST NA NA NA NA
100 / 50 / 1
208-230 / 60 / 1
UT6220E 3/4+ ST NA ST NA NA NA NA
200 / 50 / 1
UJ9226E 1 230 / 60 ST NA ST OP NA NA NA
208-230 / 60 / 1
UJ9232E 1 ST NA ST OP NA NA NA
200 / 50 / 1
UH23B153C 1 208-230 / 60 / 1 ST NA ST ST NA NA NA
UH23B193C 1 1/2 208-230 / 60 / 1 ST NA ST ST ADJ ADJ NA
208-230 / 60 / 3
UH23B203D 1 1/2 ST NA ST ST ADJ ADJ NA
200-220 / 50 / 3
UH23B243C 2 208-230 / 60 / 1 ST ST NA ST FIX ADJ ST
208-230 / 60 / 3
UH23B243D 2 ST ST NA ST FIX ADJ ST
200-220 / 50 / 3
UH23B303C 2 1/2 208-230 / 60 / 1 ST ST NA ST FIX ADJ ST
208-230 / 60 / 3
UH23B303D 2 1/2 ST ST NA ST FIX ADJ ST
200-220 / 50 / 3
R 22 460 / 60 / 3
UH23A323 2 1/2 ST ST NA ST FIX ADJ ST
380-415 / 50 / 3
UH23A383C 3 208-230 / 60 / 1 ST ST NA ST FIX ADJ ST
208-230 / 60 / 3
UH23A383D 3 ST ST NA ST FIX ADJ ST
200-220 / 50 / 3
460 / 60 / 3
UH23A383 3 ST ST NA ST FIX ADJ ST
380-415 / 50 / 3
UH23A423C 3 1/2 208-230 / 60 / 1 ST ST NA ST FIX ADJ ST
208-230 / 60 / 3
UH23A423D 3 1/2 ST ST NA ST FIX ADJ ST
200-220 / 50 / 3
460 / 60 / 3
UH23A423 3 1/2 ST ST NA ST FIX ADJ ST
380-415 / 50 / 3
208-230 / 60 / 3
UH23A543D 4 1/2 ST ST NA ST FIX ADJ ST
200-220 / 50 / 3
460 / 60 / 3
UH23A543 4 1/2 ST ST NA ST FIX ADJ ST
380-415 / 50 / 3
208-230 / 60 / 3
UH23A623D 5 ST ST NA ST FIX ADJ ST
200-230 / 50 / 3
460 / 60 / 3
UH23A623 5 ST ST NA ST FIX ADJ ST
380-415 / 50 / 3
20
High Low
Nominal Liquid Suction Crankcase Pressure Pressure Fan Cycling
CU Model # Volt / Hz / Phase Base Valve
Power Receiver Accumulator Heater Control Control Control
Switch Switch
UT2155GK- 1/2+ 115 / 60 / 1 ST NA ST NA NA NA NA
UT2155GK- 1/2+ 220 / 50 / 1 ST OP ST NA OP OP NA
UNE2134GK 1/2 115 / 60 / 1 ST NA ST NA NA NA NA
UNE2134GK 1/2 220 / 50 / 1 ST NA ST NA OP OP NA
UNE6181GK 1/2- 115 / 60 / 1 ST NA ST NA NA NA NA
UNE6195GK 1/2- 115 / 60 / 1 ST NA ST NA NA NA NA
UNE6210GK 1/3+ 208-230 / 60 /1 ST NA ST NA NA NA NA
UNE9213GK 1/2 115 / 60 / 1 ST NA ST NA NA NA NA
UT6217GK 2/3- 115 / 60 / 1 ST NA ST NA NA NA NA
UT6217GK 2/3- 208-230 / 60 /1 ST NA ST NA NA NA NA
UT6220GK 3/4+ 115 / 60 / 1 ST NA ST NA NA NA NA
UT6220GK 3/4+ 208-230 / 60 /1 ST NA ST NA NA NA NA
UT6222GK 1- 115 / 60 / 1 ST NA ST NA NA NA NA
UT6222GK 1- 208-230 / 60 /1 ST NA ST NA NA NA NA
U(N)J9226GK 1 1/6 208-230 / 60 /1 ST NA ST OP NA NA NA
UT2178GK 1- 115 / 60 / 1 ST NA ST NA NA NA NA
UT2178GK 1- 230 / 60 / 1 ST NA ST NA NA NA NA
UT2178GK 1- 220 / 50 / 1 ST OP ST NA OP OP NA
UJ2192GK 1 115 / 60 / 1 ST NA ST OP NA NA NA
UJ2192GK 1 220 / 50 / 1 ST OP ST OP OP OP NA
UJ2192GK 1 230 / 60 / 1 ST NA ST OP NA NA NA
R 404A UJ2212GK 1 1/2 230 / 60 / 1 ST NA ST OP NA NA NA
UJ2212GK 1 1/2 220 / 50 / 1 ST OP ST OP OP OP NA
UNJ2212GK 1 1/4 115 / 60 / 1 ST NA ST OP NA NA NA
UNJ2212GK 1 1/4 230 / 60 / 1 ST NA ST OP NA NA NA
UNJ2212GK 1 1/4 220 / 50 / 1 ST OP ST OP OP OP NA
UNJ2192GK 1 208-230 / 60 / 1 ST NA ST OP NA NA NA
UL63B652C 1 208-230 / 60 / 1 ST NA ST OP NA NA NA
UL63B752C 2 208-230 / 60 / 1 ST NA ST OP ADJ ADJ NA
208-230 / 60 / 3
UL63B752D 2 ST NA ST OP ADJ ADJ NA
200-220 / 50 / 3
460 / 60 / 3
UL63B752 2 ST NA ST OP ADJ ADJ NA
380-415 / 50 / 3
UL63A113C 3 208-230 / 60 / 1 ST NA NA OP FIX ADJ ST
208-230 / 60 / 3
UL63A113D 3 ST NA NA OP FIX ADJ ST
200-220 / 50 / 3
460 / 60 / 3
UL63A113D 3 ST NA NA OP FIX ADJ ST
380-415 / 50 / 3
UL63A113 3 220-240 / 50 / 1 ST NA NA OP FIX ADJ ST
UL63A183C 4 208-230 / 60 / 1 ST NA NA OP FIX ADJ ST
208-230 / 60 / 3
UL63A183D 4 ST NA NA OP FIX ADJ ST
200-220 / 50 / 3
UL63A183 4 220-240 / 50 / 1 ST NA NA OP FIX ADJ ST
460 / 60 / 3
UL63A183 4 ST NA NA OP FIX ADJ ST
380-415 / 50 / 3
ST = Standard
NA = Not Available
OP = Optional (Please specify if this feature is required for your application)
FIX = Fixed (The high pressure cutout setting is not adjustable. The switch is located inside the electrical box)
ADJ = Adjustable (The high pressure cutout setting is adjustable. The switch is located above the electrical box)
21
Valves Operation
SPINDLE BACK POSITION
Process port closed
AB
Hexagonal blind nuts
(tightening torque 8 - 12 lb.ft)
RECOMMENDED TORQUE
VALVE NOMINAL ORIENTABLE FIXING NUT SPINDLE
DIMENSION (SAE)
THREAD (UNF) TORQUE (lb.ft) TORQUE (lb.ft)
1/4” SAE N/A 4.4 - 5.5 5.9 - 7.4
3/8” SAE N/A 5.5 - 6.9 7.4 - 9.3
1/2” SAE 49 - 60 6.9 - 8.3 9.3 - 11.3
5/8” SAE 49 - 60 8.3 - 10.1 11.3 - 13.7
3/4” SAE 81 - 100 10.1 - 12.0 13.7 - 16.2
N/A = No Applicable
22
Nomenclature
Embraco Aspera - 1/6 - 1/3+ HP
Width
Height
Length
Compressor
Width
Height
Length
U J 6 220 Z
A - B - C - D =Z GS = R 404A (3 Phase)
Refrigerant E - F - G = R 22 (1 Phase) Z - ZH = R 134a (1 Phase)
GK = R 404A (1 Phase) ZX = R 134a (3 Phase)
The first digit is the number of zeros that must be added to the last two digits to obtain the cooling
Cooling Capacity
capacity (approx) in kcal/h 50 Hz. E.g.: 144=440 kcal/h at 50 Hz
1. LBP - HST
Application 2. HBP - HST
3. MBP/HBP - HST
U = Condensing Unit
T = T Compressor
J = Compressor Family J = J Compressor
NE = NE Compressor
Optional Accessories: Receiver, Discharge Valve, Suction Valve, Fan Guard.
23
Nomenclature
Embraco Aspera - 1 1/2 - 5 HP Width
Length
Height
U L 6 3 A 113 C
A = A Compressor
Compressor Family
B = B Compressor
2 = R 22
Refrigerant
6 = R 404A
H = Medium/High Temperature
Application M = Medium Temperature
L = Low Temperature
U = Condensing Unit
24
soluções.com
condensing
Brazil
Rui Barbosa, 1020 - P.O. BOX 91
89219-901 - Joinville - SC - Brazil
Phone: +55 47 3441-2121
Fax: +55 47 3441-2780
Units
Via Buttigliera 6
10020 - Riva Presso Chieri (Torino) - Italy
P.O. BOX 151 - 10023 Chieri (TO)
Phone: +39 011 943-7111
Fax: +39 011 946-8377
+39 011 946-9950
Italy
Subject to alteration without previous notice. - Code 06001 - Date May 2008 - Version 00.
Europe - Sales Office
Zona Industriale D1 - Via Fratelli Gambino, 7
10023 - Chieri (Torino) - Italy
Phone: +39 011 940-5611
Fax: +39 011 940-5656
R 134a
Fax: +42 153 417-2299
Slovakia
R 404A
R 22
México - Sales Office
Torre Alestra, Piso 3 - Office 373
Av. Lázaro Cárdenas 2321 Pte.
2800 Vista Ridge Drive NE P.O. BOX 66260 - San Pedro Garza García
Suwanee, GA 30024-3510 Nuevo León - México
Phone: +1 678 804-1337 Phone: +52 81 1001-7102
Fax: +1 678 804-1338 Fax: +52 81 1001-7142
U.S.A.
29 Yuhua Road
Area B of Beijing Tianzhu Airport Industrial Zone
101312 - Beijing - China
Phone: +86 10 8048-2255
Fax: +86 10 6725-6825
China
www.embraco.com
c o o l i n g s o l u t i o n s
Embraco is participating in the United Nations Global Compact.