ULTIMATE STRENGTH ANALYSIS FOR ECCENTRICALLY-LOADED BOLTS SYSTEM: SHEAR ONLY

(nominal strength determined by bolt shear strength; vertical load only) units: kN & mm
legends:
Bolt grade: A325M-X (choose: A307M; A325M-N; A325M-X; A490M-N; or A490M-X) known parameter
F nv = 469 MPa given value for kN - mm units
db = 20 mm iterated value
2
Ab = 314.16 mm iteration checking
fRn = 110.5 kN (nominal shear strength of 1 bolt) results

Bolt # origin at bolts centroid origin at IC r D R R*r Ry Rx


x (mm) y (mm) x (mm) y (mm) (mm) (mm) (kN) (kN.mm) (kN) (kN)
1 0.0 -60.0 32.00 -60.00 68.00 8.160 321.67 21873.37 151.37 -283.82
2 40.0 0.0 72.00 0.00 72.00 8.640 322.94 23251.71 322.94 0.00
3 0.0 60.0 32.00 60.00 68.00 8.160 321.67 21873.37 151.37 283.82
4 -40.0 0.0 -8.00 0.00 8.00 0.960 174.27 1394.14 -174.27 0.00

S= 68392.60 451.42 0.00


IC coordinate (origin at bolts centroid)
x IC = -32.00 mm acceptable tolerance: 0.01
y IC = 0.00 mm (S R y - P )/P = 0.00326 (OK)

D max = 8.64 mm ex = 120.00 mm (load eccentricity from bolts centroid)


r max = 72.00 mm r0 = 32.00 mm (distance between bolts centroid to IC)

Ru = 329 kN (ultimate shear strength of 1 bolt)


P= 449.95 kN (ultimate load of bolts system)

C= 1.37 (ratio of P /R u )
P u.max = 151.13 kN (maximum factored load; parallel to y-axis)