(nominal strength determined by bolt shear strength; vertical load only) units: kN & mm
legends:
Bolt grade: A325M-X (choose: A307M; A325M-N; A325M-X; A490M-N; or A490M-X) known parameter
F nv = 469 MPa given value for kN - mm units
db = 20 mm iterated value
2
Ab = 314.16 mm iteration checking
fRn = 110.5 kN (nominal shear strength of 1 bolt) results
C= 1.37 (ratio of P /R u )