Two Storey Residential PLANS
Two Storey Residential PLANS
K
- REAR ELEVATION
- RIGHT SIDE ELEVATION
N - SCHEDULE OF WINDOWS
E
D
0
100
100
0
NORTH
Y
00
0
900
155
0
00
100
1350
0
0
400
T. STRUCTURAL
8
402
AC
5
RR
0 TE
100
6' 7
100
400
0
0
E
6
S-1 - FOUNDATION PLAN
100
0
E N
I
0
100
I
5'
- SECOND FLOOR BEAM FRAMING PLAN
- ROOF BEAM FRAMING PLAN
L
- STRUCTURAL DETAILS
F
947
5
114
Y
O
5
75
T
O
00
100
G R 00
120 R
LO
E
4
F P
100
0
0
100 2'
T
P 3
E
D1
D C1
2 S-3 - SCHEDULE OF BEAMS
33
C - GENERAL NOTES
B
6 A 1
ELECTRICAL
- GROUND FLOOR LIGHTING LAYOUT
PERSPECTIVE
PLUMBING
P-3 - SPECIFICATIONS
- GENERAL PLUMBING NOTES
- LEGENDS/ABBREVIATIONS
ELECTRICAL
G
SANITARY
SUBDIVISION PLAN
VICINITY MAP
MECHANICAL MECHANICAL
CIVIL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:
PERSPECTIVE
SITE DEVELOPMENT PLAN A-1
PROPOSED TWO STOREY RESIDENTIAL BUILDING SUBDIVISION PLAN
VICINITY MAP 1 13
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : ARCHITECTURAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
A B C D E F A B C D E F A B C D E F
15000 C1 D1 E1 C1 D1 E1
10000 12000
2500 2500 5000
3000 2000 1500 2500 4000 2000
1000 10000 1000
P R O P E R T Y L I N E R O O F L I N E R O O F L I N E
1000
1000
1 1
1700
LAV LAV
CLOSET CLOSET
D7 D7
5000
1' 1'
2 2
5000
BEDROOM BEDROOM
1 2
3300
D8 D8
1 D6 LAV D7
A
D6
11475
9475
DRIVER'S MAID'S LAUNDRY
2000
ROOM ROOM
3 3
T&B AREA
DN
D6
2
2425
13500
15500
3500
D12
DINING T&B
3000
AREA KITCHEN 4 4
3500
A D8
OFFICE
2000
D8 D11
3 D6
D10
POWDER
ROOM D5 4' 4'
22000
1000
2500
BAR WALK-IN
MASTER
CLOSET 1000
14000
UP
5000
BEDROOM
3500
4000
4000
4075
D9
4
D3
D4 LANAI 5 TERRACE 5 TERRACE
4025
D3
5' 5'
4700
1000
TV 6 6
3200
ROOM
1000 5000 4000 1000 9000 1000
LIVING
D1
ROOM 9000 4000 10000
5 B
D2 D2
7
1800
1800
B
4000
9000
3000
A B C D E F F E D C B A 7 6 5 4 3 2
108
2608
2500
2500
2608
2500
3000
3000
3000
1000
1000
6000
6000
3000
3000
3000
2608
2100
2100
2100
2100
2100
2100
3000 PANEL DOOR GLASS SLIDING DOOR GLASS SLIDING DOOR SLIDING PANEL DOOR PVC DOOR FLASH DOOR
ON 2" x 5" JAMB ON ALUMINUM JAMB ON ALUMINUM JAMB ON 2" x 5" JAMB ON 2" x 5" JAMB ON 2" x 5" JAMB
COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/
ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES
3000
B C D E F
2100
2100
2100
2100
2100
2100
2608
2500
SEE TRUSS DETAILS PVC DOOR FLASH DOOR GLASS SLIDING DOOR FLASH DOOR GLASS SLIDING DOOR GLASS SLIDING DOOR
ON 2" x 5" JAMB ON 2" x 5" JAMB ON ALUMINUM JAMB ON 2" x 5" JAMB ON ALUMINUM JAMB ON ALUMINUM JAMB
COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/
ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES
3 SETS 4 SETS 1 SET 1 SET 1 SET 1 SET
3000
BEDROOM
T&B
6000
1600
DINING 1030
BAR
3000
600
AREA 800
500
300
300
400
400
1000
1200
1200
1 SECTION THRU "A"
1800
1700
A 03 SCALE: 1:100 METERS
1100
900
900
1 1 1 1 1
2 3 4 5 6 7 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON
SLIDING WINDOW WITH SLIDING WINDOW WITH SLIDING WINDOW WITH AWNING WINDOW WITH AWNING WINDOW WITH
COMPLETE ACCESSORIES COMPLETE ACCESSORIES COMPLETE ACCESSORIES COMPLETE ACCESSORIES COMPLETE ACCESSORIES
4 SETS 1 SET 2 SETS 1 SET 1 SET
2000
2608
300
400
500
1200
3000
1700
1600
HALLWAY BEDROOM
BEDROOM
900
1 1 1
4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON
MAID'S
3000
KITCHEN SLIDING WINDOW WITH AWNING WINDOW WITH SLIDING WINDOW WITH
ROOM
COMPLETE ACCESSORIES COMPLETE ACCESSORIES COMPLETE ACCESSORIES
HALLWAY
3 SETS 1 SET 3 SETS
P R O P E R T Y L I N E
R O O F L I N E
WF WF WF WF WF
PC
C4F4 C4F4 C4F4 C4F4 C4F4 C4F4 1 1
B1 B1 B2 RB1 RB1
1700
WF
S2
1700
WF
B1
B1
B5
S2 S2 S2
B1
B5
5000
1' 1'
C4F4 C4F4 2 2
B1 B1
5000
RB1
5000
RB3
RB1
C1F1 C1F1
3300
S2 S2
C1F1 C1F1 S2
3300
B1
B5
B4
B1
FTB FTB
1
WF
WF
FTB
B1 B2
FTB
2000
FTB 3
FTB
WF
3
B3
C1F1 C1F1 C1F1
WF
C4F4 C4F4 DN
RB1 RB2
2 S2
B1
2425
RB1
2425
FTB FTB
RB3
B1
3500
RB1
S2
3500
B1
FTB
WF
FTB
WF
3000
4 4
3500
100MM THICK SLAB ON FILL
RB1 RB3
C1F1 C1F1 WITH 10MMØ TEMP. BARS C1F1 S2 PC
B3
C4F4 C4F4
2000
RB1
2000
@ 300MM O.C. B.W.
WF C2F2 S1 B2
B3
B3
3 RB1
WF
4' 4'
WF
B4 PC B4
FTB
RB3
22000
WF
FTB
S2
2500
B2
WF
B1
WF
S2
B1
C2F2 C5F3 S1
14000
RB2
UP
5000
5000
B5
WF
3500
RB1
C4F4 C4F4
4075
4
RB1
4075
FTB
B2
B1 B1 B1
C1F1 C1F1 C2F2 C1F1 5 S2
5
WF S1 S1
CB
S1
CB
CB
CB
C3F3
B4 PC B6 PC B6 PC RB1
RB1
WF
5'
B3
5'
B3
B3
B3
WF
4700
FTB
6 B5 B5 6
C4F4
FTB
3200
WF
1800
C3F3 C3F3 C3F3 C3F3
C4F4 S 01 SCALE: 1:100 METERS S 01 SCALE: 1:100 METERS
6 FTB FTB FTB
3500 2000 3500
l
WF
600
1 FOUNDATION PLAN LEVEL C-1 C-2 C-3 C-4 C-5 PC
S 01 SCALE: 1:100 METERS
FTB
FTB
1500
200
400
300
400
300
200
300
200 200
200
T
400
400
400
L T
4
S 01 SCALE: N.T.S.
2608
TOP & BOT. CHORD
16 mmØ HOOK
EXTENDED FROM
AROUND 2 @ 50MM, 5 @ 75MM, 5 @ 100MM
COLUMN
5 @150MM,REST @ 200MM FROM FACE OF
COLUMN
100
1'
5537
2 -2
HT
HT-1
HT
4737
- 2
338 600 1200 1200 1200 1200 525 1200 1200 1200 1200 600 338
12000
2708
ANGULAR BAR
ANGULAR BAR
2708
TOP & BOT. CHORD
TOP & BOT. CHORD
100
100
1200 1200 1200 1200 738
4263
-2 5538
631 1200 1200 1200 1200 1200 1200
HT
HT-1
5538
4 3
7831
T-
H HT-2
2" x 5" x 1.5 mm THK
2" x 5" x 1.5 mm THK
HT-4 C-PURLINS C-PURLINS
4' SPACED @ 300 mm O.C. SPACED @ 300mm O.C.
1
2 - 1.5" x 1.5" x 4" 2 - 1.5" x 1.5" x 14"
ANGULAR BAR ANGULAR BAR
2 - 2" x 2" x 14"
WEB MEMBERS WEB MEMBERS 2 - 2" x 2" x 14"
ANGULAR BAR
2600
ANGULAR BAR
2600
TOP & BOT. CHORD
4500
TOP & BOT. CHORD
- 3
HT
HT
-3
HT-4
100
4025
100
295 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 500
7495 5300
77.79MM
(TYP.)
HOR. BARS (TYP.)
5 1/8"
600 (min) VARIES VER.
(min)
480
F.F.L.
200
2-10MMØ
200
CONT. BARS
12Ø @ 300 O.C. MIDDLE 10MM DIA. TEMP. BARS 10MM DIA. TOP BARS @ 100MM
100
600 200
2-16MMØ
@ 300MM O.C. O.C. (SHORT SPAN END SUPPORT)
CONT. BARS
100 200 100 TOP & BOT. L/5 L/4
EXTERIOR WF FTB SUPPORTED CHB WALL
INTERIOR WF 50MM THICK GRAVEL FILL DISCONTINUOUS CONTINUOUS
COMPACTED SOIL
100
3 WALL FOOTING DETAILS 4 DETAIL OF SLAB ON FILL
S 02 SCALE: NTS S 02 SCALE: NTS BEAM
10MM DIA. TEMP. BARS
@ 300MM O.C.
10MM DIA. BOTTOM
BARS @ 100MM O.C.
L/7 L/6
(MID OF SHORT SPAN)
S-1
6 RC SLABS ONE-WAY REINFORCED
S 02 SCALE: NTS
L
4
)
4
W
4
(W
AN
W
SP
AN
LO LO
SP
NG O RT NG
T
S
R
SP SH PA
O
SH
AN N(
(L) L)
4
W
W
4
SECOND
L
4
FLOOR
300
SB
150
GROUND
FLOOR
250
250
200
800
300
2 DETAILED SECTION OF STAIRCASE
DETAIL OF ONE-WAY SLAB (S-1) DETAIL OF TWO-WAY SLAB (S-2) S 05 SCALE: NTS
S 03 SCALE: NTS
3
L - 2"x2"x16 "
CLIP ANGLE FULLY
BOTTOM CHORD
WELDED TO TOP CHORD
10mm
(PLAIN
(1
@ 0.60m
LINEØROUND
PER
PURLINS
SAGBAY)
RODS
O.C.
BAR)
"2LB -TO
TOP
4
1 3"
"2LB -TO
BOTTOM
4
1
CHORD
xB 3" x MEMBERS
3" xB 3"CHORD
x MEMBERS
"3122L
AUXILLIARY
6B
x -1TO
"2LB -TO
WEB
4
1
1 B MEMBERS
2"MEMBERS
xB 2" x
DEPTH
STIFF. BARS
D
6mm
BAR "D" EXTRA BOT. BAR "D" EXTRA BOT.
BAR "B" CONT. BOT. BAR "B" CONT. BOT. BOT. BARS WEB MEMBERS
L1 / 5 L1 / 5 L2 / 5 L2 / 5
4 CONNECTION DETAILS
S 03 SCALE: NTS
300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B. B,C,D 2 @ 50 MM
2 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
2 @ 75 MM
2 @ 100MM
B. ALL DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES UNLESS CONCRETE HOLLOW BLOCKS:
REST @ 200 MM O.C. OTHERWISE INDICATED REINFORCEMENT AS TABULATED BELOW SHALL BE PROVIDED UNLESS OTHERWISE
200 200
C. FOR ALL OTHER REQUIREMENTS, REFER TO ARCHITECTURAL, SANITARY, ELECTRICAL
AND MECHANICAL WORKING DRAWINGS. SPECIFIED IN THE PLAN
B= 3 METERS
5 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
10 DIA. MM STIRRUPS
2 @ 50 MM FOOTINGS: CONCRETE HOLLOW BLOCKS REINFORCEMENT
3 @ 75 MM
1. FOOTINGS ARE DESIGNED ON NATURAL GRADE LINE WITH A MIN. BEARING CAPACITY
300
300
B-2
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
D,E 3 @100 MM BLOCK REINFORCEMENT NOTES
REST @ 200 MM O.C. OF 144 KPa.
3 - 16 MM Ø D.R.B. 5 - 16 MM Ø D.R.B.
2. NO FOOTING SHALL REST ON FILL. THK. HORIZONTAL VERTICAL
200 200
C = 4 METERS 3 MINIMUM CONCRETE PROTECTION FOR REBARS SHALL BE 0.076m. CLEAR FOR
10 DIA. MM STIRRUPS CONCRETE DEPOSITED AGAINST THE GROUND AND 0.05m. CLEAR FOR CONCRETE DEPOSITED
2 @ 50 MM AGAINST THE FORM WORK.
FREE-END 4 @ 75 MM
4 @ 100 MM
3 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.
REST @ 200 MM O.C. CONCRETE MIXES & PLACINGS :
300
300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
B-3 A,B,C,D 1. UNLESS OTHERWISE SPECIFIED, THE MINIMUM 28 DAYS CYLINDER COMPRESSIVE
2 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B. D = 5 METERS STRENGTH ARE AS FOLLOWS.
200 200
10 DIA. MM STIRRUPS
2 @ 50 MM
FOOTINGS & BEAMS ON GRADE---------------------------------------21.0 MPa
CONCRETE SLABS:
5 @ 75 MM
5 @ 100 MM COLUMNS------------------------------------------------------------------21.0 MPa 1. ALL REINFORCEMENT SHALL BE 0.019m CLEAR MINIMUM FROM TOP AND BOTTOM OF SLAB.
REST @ 200 MM O.C. SLAB, BEAMS & GIRDERS-----------------------------------------------21.0 MPa 2. FOR TWO- WAY SLAB BARS ALONG SHORTER SPAN SHALL BE PLACED BELOW THOSE ALONG
FREE-END PARTITIONS, PARAPET & SHEAR WALL-------------------------------21.0 MPa THE LONGER SPAN .AT CENTER AND OVER THE LONGER SPAN BARS NEAR THE SUPPORT
5 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B. BEDDED SLABS, CATCH BASINS & SIDE WALK----------------------17.5 MPa UNLESS OTHERWISE INDICATED OR SHOWN IN DETAILS THE SPACING OF THE BARS AT THE
E = < 5 > METERS
B-4 C,D 10 DIA. MM STIRRUPS COLUMN STRIPS CAN BE APPROXIMATELY 1-1/3 OF THE MIDDLE STRIPS BUT IN NO CASE
300
300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
7 @ 50 MM 2. ALL CONCRETE MUST BE DEPOSITED, VIBRATED AND CURED IN ACCORDANCE WITH
ACT STANDARD 318-89. GREATER THAN 2-1/3 TIMES THE SLAB THICK.
7 @ 75 MM
3 - 16 MM Ø D.R.B. 5 - 16 MM Ø D.R.B.
7 @ 100 MM 3. STRIPPING FORMS AND SHORES SHALL BE AS FOLLOWS 3. UNLESS OTHERWISE SHOWN IN DETAIL FOR ONE WAY SLAB, REINFORCING BARS SHALL BE
200 200 REST @ 200 MM O.C. BEND, EXTENDED OR CUT AS FOLLOWS. NO CASE LESS THAN 6.7mm. FOR EVERY 3.00M.
FOUNDATIONS I DAY OF FREE SPAN.
COLUMNS & WALLS 3 DAYS
FREE-END FREE-END BEAMS & GIRDER 21 DAYS
B,C,D SLABS 17 DAYS
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.
B-5 4. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION RE-HANDLING
300
300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
OR FLOWING, PLACING- SHALL BE DONE PREFERABLY WITH BUGGIES BUCKETS OR WHEEL
3 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B. BARROWS. NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS
200 200 TO BUGGIES, WHEELBARROWS, OR BUCKETS IN WHICH CASE THEY SHALL NOT EXCEED 600m IN
AGGREGATE LENGTH, NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF
VIBRATOR - UNLESS AUTHORIZE IN WRITING BY THE DESIGNERS AND ONLY FOR USUAL
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.
CONDITIONS WHERE VIBRATOR IS EXTREMELY DIFFICULT TO ACCOMPLISH.
RB-1
300
300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
B,C,D
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.
300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B. O.C AND IN NO CASE SHALL BE LESS THAN TWO (2) SEPARATORS.
D,E 3. NO SPLICE SHALL BE PERMITTED ON BEAMS AND GIRDERS WHERE CRITICAL BENDING STRESSES
2 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
OCCUR TENSION SPLICE SUPERMITTED SHALL BE 48 DIAMETER FOR PLAIN BARS AND 24 MILD STEEL REINFORCEMENT:
200 200 DIAMETER FOR DEFORMED BARS, COMPRESSION SPLICE SHALL BE 40 DIA. FOR PLAIN BARS 1. ALL MILD STEEL REINFORCEMENT SHALL CONFORM TO ASTM A-15-62-21 AND DEFORMATIONS
FOR PLAIN BARS AND 20 DIA. FOR DEFORMED BARS LAP SPLICES SHALL BE WIRED
FREE-END TOGETHER SPLICE TOP BARS AT MID SPAN BOTTOM BARS AT SUPPORT BENT BARS TO A REVISIONS.
3 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B. AT BEND POINTS IN SUPERSTRUCTURE WELDED SPLICES SHALL BE DEVELOPED 2. DEVELOPMENT LENGTH FOR ALL BARS SHALL BE A MINIMUM OF 40 BARS DIA. UNLESS
INTENSION AT LEAST 125 Ø OF THE SPECIFIED YIELD STRENGTH OF THE BAR NOT OTHERWISE SPECIFIED.
RB-3
300
300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
D,E MORE THAN 50 % OF THE BARS AT ANY ONE SECTION SHALL BE PERMITTED
2 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
TO BE SPLICED.
4. IF BEAM REINFORCING BARS END IN A WALL THE CLEAR DISTANCE FROM THE BAR TO 12 ; Fy= 225 MPa
200 200
THE FURTHER FACE OF THE WALL SHALL NOT BE LESS THAN 0.051m EMBEDMENT STRUCTURAL STEEL: 16 ; Fy= 275 MPa
LENGTH SHALL BE 40. DIA FOR TENSION AND 20 DIA. COMPRESSION BARS.
3 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
5. MINIMUM CONCRETE PROTECTION REINFORCING BARS OR SHAPE SHALL BE AS SHOWN 1. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A-36 Fy= 36,000 PSI
2. WELDING SHALL CONFORM TQ AWS STANDARDS .
CB
300
300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
D,E 3. FABRICATOR SHALL SUBMIT SH0P DRAWINGS FOR APPROVAL BY THE ENGINEER
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B. AND THE OWNER PRIOR TO FABRICATION.
200 200
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.
300
300
200 200
R O O F L I N E
3 12
1 1 1
S1
LAV
S1 S1 EF EF
LAV
1700
LAV LAV
EF S1
2000
2000
S1
5
1' 6
2 2 2
S2 10
5000
3300
3000
3000
S2 S2
3500
3500
S2
9
7
3 3 S2W S1 3
POWDER LPP POWDER
ROOM DN ROOM
EF
S1
2425
2500
2500
BAR BAR
3500
14000
14000
UP UP
3500
3500
S2W S1 T&B
S2
4 S1
Sc
S2 4 4
c c LPP1 8 4
11
S1
2000
S1
S2 S2
S1
S1 S1
Sa a a 4' a
4700
4700
b b a a
Sa
S1
3200
3200
5000
4075
a S1
a S2 Sab a a 8
5 1 S2 S2 S S1 5 Sa 5
2 a
S1 a a
1800
1800
1800
1800
5'
6 6 6
3500 2000 3500 1000 5000 4000 3500 2000 3500
3000
2 SECOND FLOOR LIGHTING LAYOUT
E 01 SCALE: 1:100 METERS
R O O F L I N E R O O F L I N E
1 21 22 1 LAV
INTERCOM
1
1700
LAV LAV
1700
LAV LAV
2000
1' INTERCOM
1'
2 2 2
5000
5000
3300
3300
3000
3500
19 14 18
3 17 3 3
POWDER
DN ROOM
DN
2425
2500
2425
INTERCOM
BAR
3500
3500
14000
UP
3500
T&B T&B
4 4 4
LPP1
INTERCOM
20 CCTV &
OFFICE OFFICE
2000
2000
INTERCOM
16 INTERCOM
CONTROL &
MONITOR
4' 4'
4700
INTERCOM
13
WALK-IN WALK-IN
3200
MASTER MASTER
CLOSET CLOSET
5000
5000
BEDROOM BEDROOM
4075
4075
5 15 5 5
1800
1800
5' 5'
6 6 6
1000 5000 4000 3500 2000 3500 1000 5000 4000
3000
4000 9000
2. THE SERVICE ENTANCE SHALL BE THREE PHASE, FOUR WIRE, 13.4 KV, 60 HZ.
3. ALL MATERIALS AND EQUIPMENT TO BE USED SHALL BE NEW AND APPROVED TYPES
OF THE LOCATION AND PURPOSE.
5. MOUNTING HEIGHT FOR LIGHT SWITHES AND BUTTON SHOULD BE 1.4 METERS
ABOVE FLOOR LEVEL.
LEGENDS
CIRCUIT HOMERUN
LPP
PANEL BOARD M KILOWATT HOUR METER
CCTV
INTERCOM
R O O F L I N E
10
100 MMØ DP/SP 100 MMØ DP/SP 100 MMØ DP/SP WR
1 1 1 1/2"Ø CWL 1/2"Ø CWL
50
0M
CO
MM
50
50
50
MØ
10
50
50
SS SS
CB 50LAV CO CB CB
0M
Ø
MM
MM
MM
LAV
MM
SP
MM
MM
DP
MØ
100 MMØ DP/SP
Ø
50 Ø D
Ø
DP
DP
DP
DP
DP
MM P
SP
1/2"Ø CWL
FD FD
1700
FD
1/2"Ø CWL
LAV LAV FD WC
1/2"Ø CWL
2000
2000
10 WC WC
0M
MØ
SP
WC
DP
FD SHO
LAV
1'
Ø
MM
100 MMØ DP/SP 100 MMØ DP/SP LAV
2 CO
2 2 1/2"Ø CWL
50
100 MMØ DP/SP
CB CB
5000
DP
SEPTIC MM
Ø
50
TANK
FD SINK DP
Ø
MM
3000
1/2"Ø CWL
3000
DP
Ø USE 12" Ø PIPE CWL
3500
3500
50 FOR ALL FIXTURES
SINK
CB
3 LAV 3 DP 100 MMØ DP/SP
3
DP CO DP MØ
1/2"Ø CWL
50 POWDER Ø M POWDER
Ø MM 50
MM ROOM MM DN ROOM
1/2"Ø CWL
Ø 50 50
10 DP FD FD
0M
MØ LAV DP FD DP LAV
Ø Ø
SP WC FD MM MM
2425
2500
2500
CO BAR 50 CO
FD
50
BAR
150 MMØ DP/SP
3500
14000
14000
UP UP
DP
MØ
3500
3500
CB T&B 50
M
4 4 4
50 MMØ DP
FD 1/2"Ø CWL
LAV DP
Ø
MM
10
50 HB
0M
WC
MØ
OFFICE
2000
CO CO
SP
CB
CB 4' FD
4700
4700
FD
150 MMØ DP/SP
WALK-IN
3200
3200
MASTER
CLOSET
5000
1/2"Ø CWL
BEDROOM
4075
CB
5 5 5
1800
1800
1800
1800
FD
FD
CB
5'
CB
6 6 6
150 MMØ DP/SP
CB CB
1/2"Ø CWL
3500 2000 3500 1000 5000 4000 3500 2000 3500
3000
3000
HB
GV
2 SECOND FLOOR PLUMBING LAYOUT WM
FESEAL GUM
TEST FAUCET
FLOOR FLANGE (BRASS/PVC) FLOOR FLANGE
REDUCER/BUSHING
1725
1500
TO SUPPLY
75
COMPACT EARTH
SECTION DETAIL OF WATER CLOSET CONNECTION
3 WATER METER DETAIL DETAILS OF SEPTIC TANK
P 02 SCALE NTS SCALE NTS
L
0
1/2"
D
WH WH Ø CW
I
SHO SHO
N 4 WC
LF
1' 4' US
FO
R EA
L F
200 2 "1
Ø
LL PIP L E1
2 DS
DS
0 FIX E
TU CW
RE L
I
N
5
1/2"Ø CWL
S
5000
DS
E
US
FO
RE2 "1 Ø
AL P
1/2"
Ø CW
LF
WH
SH
O F
L F IP
6 5' 407 IXTE C
3300
5 UR WL LA
DN ES V
WC
OF SH
OW
DS
FIC H
DS
E SH
O
3 1/2"Ø CWL
BE MAS Ø CW
L 1/2"
Ø CW
L
1/2"
Ø CW
L
1/2"
DN
WH
DR TE
OO R
500
SHO 0
400 0
SHO
M WC T&
2425
DS
100
0
B F
1/2"Ø CWL
USE 12" Ø PIPE CWL F L
3500
CW
1/2"Ø CWL
FOR ALL FIXTURES DS Ø
1/2"
LA
W V
T&B CL AL
OS K-I
350
4
0
500 0
LAV ET N
WC
OFFICE 1 A
2000
0
DS 900
2 1'
0
400
0
500
4' 170
B
0
WALK-IN 3 C 1 A
MASTER
CLOSET
330 SS C1
D
5000
0
BEDROOM
50 MMØ
2
100 MMØ
4 FD
4075
DP
50 MMØ
100
D1
50 MMØ
WC FD MM 200
Ø DP R
SP
242 LA /SP E 0
DP
5 V O
DP
5 O US
FO
REA1
C
4' F 3 2"
Ø
LL PIP
200 L E1 300 FIX E
TU CW 1/2 W
" R
0
100
I
N
0 RE L
S
L
1/2"
Ø CW
D
5' 5 M MØ
DP
/SP
E
F 4 1/2"
Ø CW L
F
FD SH
O L
E
50 MMØ
250
6 6 5'
140 0 1/2"
Ø CW LA
V
100 MMØ
407
50 MMØ
00
5 100 WC
LA MM
DN V FD
DP
Ø DP
1/2"
50 MMØ
DP
/SP HB Ø CW
SP
FD WC F
1000 5000 4000 OF FD CO
L
DP
FD
FIC Ø CW
L
100 MMØ
V
M
0
WC
UP 1/2"
B
0
100 US
FO
Ø CW
B C D E F FD 50 MMØ DP R EA
SP
1
2" L
Ø
L LL PIP
300 HB Ø CW FIX E F
50 MMØ DP 3/4" TU CW
D1 E1
0
C1 W
CL AL
LA
V
50 MMØ DP
RE L
S
OS K-I CO
0 350
12000 500 WM GV SIN L
BA CW
0 K
ET N
Ø
1/2"
OF NEARTAP R F
1000 10000 1000 WA EST TO
TE SO THE
R O O F L I N E R S UR LA
V L
0 UP CE Ø CW
900 PLY 1/2" 350
DS DS DS 0
1000
1000
500 0
0
400
0 350
1
350
0
0
200 00
90
1' 1 A 320
2 0
350 0
2
200 B 180
0
0
3 C
300
S CB SS
TAEPT D
0
/SP
NK IC MM
Ø DP
100
11475
4
9475
DS DS
CB
3
WATER SUPPLY LAYOUT ISOMETRIC
100 LA
E
50 MMØ
250 V
140 M CO
2
50 MMØ
MØ FD
/SP
00 0
DP
100 MM
/SP DP
/SP MØ
DP
DP 0M
/SP MØ
DP
Ø DP M FD WC10
Ø SP
150
MM 100
P 02 SCALE: 1:100 METERS
LA
50 MMØ
Ø DP V 100
5 MM CO
100 MMØ
13500
15500
470 MM
150 FD PO Ø DP
F
0 RO WD /SP
CB
DP
WC OM ER
/SP
SP
Ø DP
4 6 15 0M
M
100 VARIES(300 MIN) 100
LA
V 50
180 50 MMØ DP 50
50
0 DP
100
Ø 100
MM UP MM
150 Ø DP CB
CB /SP
50
/SP
100
Ø DP
MM
300
VARIES
DP
Ø DP
MM 50 MMØ DP
150
BA
DS
WE T R CB
/SP
RA HE CB FD 50 MMØ DP Ø DP
DS DS GE N LA MM
/CA EAR V 100
NA ES 50 MMØ DP 350
1000 L T CO 0
100
50
Ø DP
0
350 MM
150
CB
50 50
100
CB
5
350
0
VARIES (300 MIN)
4025
0 100 100
200 00
90
M Ø DP
150M
5' 0
350
320
0 PLAN SECTION
CB
1000
6
DS DS DS
10000
T
SEAP TO
WE T
CATCH BASIN
RA HE
2 AREA DRAIN LAYOUT GE NE
/CA AR
NA ES
L T
2 PLUMBING LAYOUT ISOMETRIC
P 02 SCALE: 1:100 METERS P 02 SCALE: 1:100 METERS
SANITARY TEE
CITY CONCERN.
COUNTER SUNK FLOOR
CLEANOUT "METMA"
THREADED MODEL M-335-B
TUBULAR OUTLET
2. COORDINATE THE DRAWINGS WITH OTHER RELATED
TAIL PIECE OF DRAIN
DRAWINGS AND SPECIFICATIONS. THE ENGINEER SHALL
SLIP JOINT NUTS
50
C
38.10
D
101.60
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS.
75 38.10 127.00 ANY RELOCATIONS REQUIRED FOR PROPER EXECUTION OF
100 40.00 152.40
WIRE MESH
(vent thru roof)
NO-HUB COUPLING
line of joint BOR PLUS-PVC)
SEWER AND DRAINAGE AS VERIFIED BY THE CONTRACTOR.
PIPE CLAMP
LATERAL/BRANCH
SECTION SOIL PIPE (SP)
AIRCAPPED
CHAMBER CONCRETE SLAB
ABBREVIATIONS:
0.30