TABLE OF CONTENTS REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS


TRANSPORTAION & COMMUNICATION
ARCHITECTURAL
OFFICE OF THE BUILDING OFFICIAL
A-1 - PERSPECTIVE
- SITE DEVELOPMENT PLAN
- SUBDIVISION PLAN
- VICINITY MAP

A-2 - GROUND FLOOR PLAN DISTRICT / CITY / MUNICIPALITY


- SECOND FLOOR PLAN
- ROOF PLAN
- FRONT ELEVATION

K
- REAR ELEVATION
- RIGHT SIDE ELEVATION

E A-3 - LEFT SIDE ELEVATION


- SECTION THRU "A"

N - SECTION THRU "B"


- SCHEDULE OF DOORS

N - SCHEDULE OF WINDOWS

E
D
0
100

100
0
NORTH

Y
00

LAND USE & ZONING


100

0
900

155
0

00
100

1350
0
0
400

T. STRUCTURAL
8

402
AC

5
RR
0 TE
100
6' 7

100

400
0

0
E
6
S-1 - FOUNDATION PLAN

100
0
E N

I
0
100
I

5'
- SECOND FLOOR BEAM FRAMING PLAN
- ROOF BEAM FRAMING PLAN
L

- STRUCTURAL DETAILS
F

947
5

114
Y
O
5

75
T
O
00
100
G R 00
120 R

LO
E
4
F P

S-2 - ROOF FRAMING PLAN


O
E1
- STRUCTURAL DETAILS
LINE & GRADE
R

100
0
0
100 2'

T
P 3
E
D1

D C1
2 S-3 - SCHEDULE OF BEAMS

33
C - GENERAL NOTES
B

6 A 1

ELECTRICAL
- GROUND FLOOR LIGHTING LAYOUT

SITE DEVELOPMENT PLAN E-1 - SECOND FLOOR LIGHTING LAYOUT


- GROUND FLOOR POWER LAYOUT

E-2 - SECOND FLOOR POWER LAYOUT


- GROUND FLOOR CCTV & INTERCOM SYSTEM LAYOUT
-
-
SECOND FLOOR CCTV & INTERCOM SYSTEM LAYOUT
BOARD PANEL DETAIL
ARCHITECTURAL
- POWER FEEDER SINGLE LINE DIAGRAM

E-3 - SCHEDULE OF LOADS


- GENERAL NOTES AND SPECIFICATIONS & LEGENDS

PERSPECTIVE
PLUMBING

P-1 - GROUND FLOOR PLUMBING LAYOUT


- SECOND FLOOR PLUMBING LAYOUT
- GROUND FLOOR WATER SUPPLY LAYOUT
- PLUMBING DETAILS
STRUCTURAL
P-2 - SECOND FLOOR WATER SUPPLY LAYOUT
- PLUMBING LAYOUT ISOMETRIC
- WATER SUPPLY LAYOUT ISOMETRIC
- DETAIL OF AREA DRAIN / CATCH BASIN

P-3 - SPECIFICATIONS
- GENERAL PLUMBING NOTES
- LEGENDS/ABBREVIATIONS

ELECTRICAL
G

SANITARY

SUBDIVISION PLAN
VICINITY MAP

MECHANICAL MECHANICAL
CIVIL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:
PERSPECTIVE
SITE DEVELOPMENT PLAN A-1
PROPOSED TWO STOREY RESIDENTIAL BUILDING SUBDIVISION PLAN
VICINITY MAP 1 13
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : ARCHITECTURAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
A B C D E F A B C D E F A B C D E F
15000 C1 D1 E1 C1 D1 E1
10000 12000
2500 2500 5000
3000 2000 1500 2500 4000 2000
1000 10000 1000
P R O P E R T Y L I N E R O O F L I N E R O O F L I N E

1000

1000
1 1

1700
LAV LAV
CLOSET CLOSET
D7 D7

5000
1' 1'
2 2

5000
BEDROOM BEDROOM
1 2

3300
D8 D8

1 D6 LAV D7
A
D6

11475

9475
DRIVER'S MAID'S LAUNDRY
2000

ROOM ROOM
3 3
T&B AREA
DN
D6
2

2425

13500
15500
3500
D12
DINING T&B
3000

AREA KITCHEN 4 4

3500
A D8
OFFICE

2000
D8 D11
3 D6
D10
POWDER
ROOM D5 4' 4'
22000

1000
2500

BAR WALK-IN
MASTER
CLOSET 1000
14000

UP

5000
BEDROOM

3500

4000

4000
4075
D9
4
D3
D4 LANAI 5 TERRACE 5 TERRACE

4025
D3

5' 5'
4700

1000
TV 6 6

3200
ROOM
1000 5000 4000 1000 9000 1000
LIVING
D1
ROOM 9000 4000 10000

5 B
D2 D2

7
1800

1800
B
4000

6 2 SECOND FLOOR PLAN 3 ROOF PLAN


A 02 SCALE: 1:100 METERS
A 02 SCALE: 1:100 METERS
3500 2000 3500

9000
3000

1 GROUND FLOOR PLAN


A 02 SCALE: 1:100 METERS

A B C D E F F E D C B A 7 6 5 4 3 2

108
2608
2500

2500
2608

2500

3000

3000
3000

1000
1000

6000
6000

3000

3000
3000

4 FRONT ELEVATION 5 REAR ELEVATION 6 RIGHT SIDE ELEVATION


A 02 SCALE: 1:100 METERS A 02 SCALE: 1:100 METERS
A 02 SCALE: 1:100 METERS

CIVIL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


GROUND FLOOR PLAN
SECOND FLOOR PLAN A-2
PROPOSED TWO STOREY RESIDENTIAL BUILDING ROOF PLAN
FRONT ELEVATION 2 13
PRC REG. NO. : PTR NO. : Location: REAR ELEVATION
T. I. N. : ISS. ON : RIGHT SIDE ELEVATION ARCHITECTURAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
2 3 4 5 6 7

1750 1700 1900


950 950 1000 750
875 875 850 850 700

2608

2100

2100

2100

2100

2100

2100
3000 PANEL DOOR GLASS SLIDING DOOR GLASS SLIDING DOOR SLIDING PANEL DOOR PVC DOOR FLASH DOOR
ON 2" x 5" JAMB ON ALUMINUM JAMB ON ALUMINUM JAMB ON 2" x 5" JAMB ON 2" x 5" JAMB ON 2" x 5" JAMB
COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/
ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES
3000

1 SET 2 SETS 1 SET 1 SET 1 SET 4 SETS

2 LEFT SIDE ELEVATION


A 03 SCALE: 1:100 METERS 1700
1600 1200
600 800 850 850 1200 800 800 600 600

B C D E F

2100

2100

2100

2100

2100

2100
2608

2500
SEE TRUSS DETAILS PVC DOOR FLASH DOOR GLASS SLIDING DOOR FLASH DOOR GLASS SLIDING DOOR GLASS SLIDING DOOR
ON 2" x 5" JAMB ON 2" x 5" JAMB ON ALUMINUM JAMB ON 2" x 5" JAMB ON ALUMINUM JAMB ON ALUMINUM JAMB
COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/ COMPLETE W/
ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES
3 SETS 4 SETS 1 SET 1 SET 1 SET 1 SET
3000

BEDROOM
T&B

6000
1600
DINING 1030
BAR
3000

600
AREA 800
500

300

300

400
400
1000
1200

1200
1 SECTION THRU "A"

1800
1700
A 03 SCALE: 1:100 METERS

1100
900

900
1 1 1 1 1
2 3 4 5 6 7 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON
SLIDING WINDOW WITH SLIDING WINDOW WITH SLIDING WINDOW WITH AWNING WINDOW WITH AWNING WINDOW WITH
COMPLETE ACCESSORIES COMPLETE ACCESSORIES COMPLETE ACCESSORIES COMPLETE ACCESSORIES COMPLETE ACCESSORIES
4 SETS 1 SET 2 SETS 1 SET 1 SET

2000
2608

SEE TRUSS DETAILS 1000 1000


2800
800 200 800 200 800 800

300

400
500
1200
3000

1700
1600
HALLWAY BEDROOM
BEDROOM

900
1 1 1
4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON 4" THK CLEAR GLASS ON
MAID'S
3000

KITCHEN SLIDING WINDOW WITH AWNING WINDOW WITH SLIDING WINDOW WITH
ROOM
COMPLETE ACCESSORIES COMPLETE ACCESSORIES COMPLETE ACCESSORIES
HALLWAY
3 SETS 1 SET 3 SETS

2 SECTION THRU "B" SCHEDULE OF DOORS & WINDOWS


SCALE: 1:100 METERS

CIVIL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


LEFT SIDE ELEVATION
SECTION THRU "A" A-3
PROPOSED TWO STOREY RESIDENTIAL BUILDING SECTION THRU "B"
SCHEDULE OF DOORS AND WINDOWS 3 13
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : ARCHITECTURAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
A B C D E F A B C D E F A B C D E F
15000 C1 D1 E1 C1 D1 E1
10000
2500 2500 5000
2500 2500 5000
3000 2000 1500 2500 4000

P R O P E R T Y L I N E
R O O F L I N E

WF WF WF WF WF
PC
C4F4 C4F4 C4F4 C4F4 C4F4 C4F4 1 1
B1 B1 B2 RB1 RB1

1700
WF
S2

1700
WF

B1
B1

B5
S2 S2 S2

B1
B5
5000
1' 1'
C4F4 C4F4 2 2
B1 B1

5000

RB1

5000
RB3
RB1
C1F1 C1F1

3300
S2 S2
C1F1 C1F1 S2

3300
B1
B5

B4
B1
FTB FTB
1

WF
WF

FTB
B1 B2

FTB
2000

FTB 3

FTB
WF
3

B3
C1F1 C1F1 C1F1

WF
C4F4 C4F4 DN
RB1 RB2
2 S2

B1
2425

RB1
2425
FTB FTB

RB3
B1

3500

RB1
S2

3500
B1
FTB
WF

FTB

WF
3000

4 4

3500
100MM THICK SLAB ON FILL
RB1 RB3
C1F1 C1F1 WITH 10MMØ TEMP. BARS C1F1 S2 PC

B3
C4F4 C4F4

2000

RB1
2000
@ 300MM O.C. B.W.
WF C2F2 S1 B2

B3
B3
3 RB1
WF
4' 4'
WF

B4 PC B4
FTB

RB3
22000

WF

FTB
S2
2500

B2
WF

B1
WF
S2

B1
C2F2 C5F3 S1
14000

RB2
UP

5000

5000
B5

WF

3500

RB1
C4F4 C4F4

4075
4

RB1
4075
FTB

B2
B1 B1 B1
C1F1 C1F1 C2F2 C1F1 5 S2
5
WF S1 S1

CB
S1

CB

CB
CB
C3F3
B4 PC B6 PC B6 PC RB1
RB1

WF
5'

B3
5'

B3

B3

B3
WF
4700

FTB

6 B5 B5 6
C4F4

FTB

3200
WF

1000 5000 4000


1000 5000 4000
C1F1 C5F3
100MM THICK SLAB ON FILL
C1F1
WF

100MM THICK SLAB ON FILL


C5F3 WITH 10MMØ TEMP. BARS 4000 9000
4000 9000
@ 300MM O.C. B.W.
WITH 10MMØ TEMP. BARS
@ 300MM O.C. B.W.
5
WF
FTB FTB FTB
C3F3 2 SECOND FLOOR BEAM FRAMING PLAN 3 ROOF BEAM FRAMING PLAN
FTB
FTB
1800

1800
C3F3 C3F3 C3F3 C3F3
C4F4 S 01 SCALE: 1:100 METERS S 01 SCALE: 1:100 METERS
6 FTB FTB FTB
3500 2000 3500
l
WF

10mm DIA. LATERAL TIES W/


WF

9000 #16 G.I. TIE WIRES


3000

C4F4 C4F4 C4F4 C4F4 C4F4 C4F4


WF WF WF

600
1 FOUNDATION PLAN LEVEL C-1 C-2 C-3 C-4 C-5 PC
S 01 SCALE: 1:100 METERS
FTB

FTB

1500

200
400

300
400

300
200
300
200 200
200
T

SCHEDULE OF FOOTINGS BOTTOM OF FTG

16mm DIA. BARS B.W.


SECTION (SEE SCHEDULE OF
MARK REINFORCEMENTS
(mm) W L FOOTINGS)

400

400
400
L T

F1 1200 1200 0.30 6 - 16mm DIA. BARS B.W.


200 200 200
F2 1400 1400 0.30 8 - 16mm DIA. BARS B.W.

F3 1000 1000 0.30 5 - 16mm DIA. BARS B.W.


W

F4 1000 1000 0.30 5 - 16mm DIA. BARS B.W.


5
S 01 SCALE: N.T.S.

4
S 01 SCALE: N.T.S.

CIVIL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


FOUNDATION PLAN
SECOND FLOOR BEAM FRAMING PLAN S-1
PROPOSED TWO STOREY RESIDENTIAL BUILDING MR. JOHN AND NYMPHA VAN DER FLAES ROOF BEAM FRAMING PLAN
DETAIL OF COLUMN -FOOTING 4 13
PRC REG. NO. : PTR NO. : Location: SCHEDULE OF COLUMNS
T. I. N. : ISS. ON : STRUCTURAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
PROVIDE 10 MM DIA. STIRRUPS,FOR SHORT SPAN
A B C D E F 2 @ 50MM, 2 @ 75MM,2 @ 100MM
C1 D1 E1 TYPICAL Beam 2 @150MM, REST @ 200MM FROM FACE OF
2" x 5" x 1.5 mm THK NOTE:
2500 2500 5000 C-PURLINS COLUMN
PURLINS
SPACED 300mm O.C. VERIFY ALL ACTUAL
SLOPE AND DIMENSION
2 - 1.5" x 1.5" x 14"
ANGULAR BAR 2 - 2" x 2" x 14" ALL STEEL PLATE CONNECTION
1 WEB MEMBERS ANGULAR BAR
PROVIDE 10 MM DIA. STIRRUPS,FOR 6.0 METER SPAN
SHALL BE FULL WELD ALL

2608
TOP & BOT. CHORD
16 mmØ HOOK
EXTENDED FROM
AROUND 2 @ 50MM, 5 @ 75MM, 5 @ 100MM
COLUMN
5 @150MM,REST @ 200MM FROM FACE OF
COLUMN

100
1'
5537

2 -2

HT

HT-1
HT

4737
- 2
338 600 1200 1200 1200 1200 525 1200 1200 1200 1200 600 338
12000

2" x 5" x 1.5 mm THK


C-PURLINS
T-1 2" x 5" x 1.5 mm THK
2 - 1.5" x 1.5" x 14" SPACED @ 300mm O.C. C-PURLINS
ANGULAR BAR SPACED @ 300 mm. O.C. 2 - 1.5" x 1.5" x 14"
WEB MEMBERS ANGULAR BAR
T-1 2 - 2" x 2" x 14" WEB MEMBERS
1
3 2 - 2" x 2" x 4"

2708
ANGULAR BAR
ANGULAR BAR

2708
TOP & BOT. CHORD
TOP & BOT. CHORD

100

100
1200 1200 1200 1200 738

4263
-2 5538
631 1200 1200 1200 1200 1200 1200
HT
HT-1
5538

4 3
7831

T-
H HT-2
2" x 5" x 1.5 mm THK
2" x 5" x 1.5 mm THK
HT-4 C-PURLINS C-PURLINS
4' SPACED @ 300 mm O.C. SPACED @ 300mm O.C.
1
2 - 1.5" x 1.5" x 4" 2 - 1.5" x 1.5" x 14"
ANGULAR BAR ANGULAR BAR
2 - 2" x 2" x 14"
WEB MEMBERS WEB MEMBERS 2 - 2" x 2" x 14"
ANGULAR BAR

2600
ANGULAR BAR

2600
TOP & BOT. CHORD

4500
TOP & BOT. CHORD
- 3
HT

HT
-3
HT-4

100
4025

100
295 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 500
7495 5300

5' HT-3 HT-4 PROVIDE 10 MM DIA. STIRRUPS,FOR SHORT SPAN


6 2 @ 50MM, 2 @ 75MM,2 @ 100MM
2 @150MM, REST @ 200MM FROM FACE OF
5300 5300
COLUMN
4000 9000 See Wall Detail
STEEL TRUSS DETAILS WF

1 ROOF FRAMING PLAN PROVIDE 10 MM DIA. STIRRUPS,FOR 6.0 METER SPAN


S 02 SCALE: 1:100 METERS
2 @ 50MM, 5 @ 75MM, 5 @ 100MM
5 @150MM,REST @ 200MM FROM FACE OF
COLUMN
TYPICAL WF

150 MM THK. CHB WALL 150 100


WITH 12Ø @ 400 O.C. 150 See WF Detail TYPICAL FOOTING, COLUMN AND
VERT.BARS & 12Ø @ 600
100 MM THK. CHB WALL
LEGEND:
O.C. HOR. BARS (TYP.)
WITH 10Ø @400 O.C. BEAM AND WALL FOOTING
TYPICAL FOOTING
50 mm F.F.L.
VERT. & 10Ø @ 600 O.C. 100 MM CONCRETE SLAB ON FILL
VERIFY

77.79MM

(TYP.)
HOR. BARS (TYP.)
5 1/8"
600 (min) VARIES VER.

100MM THICK SLAB ON FILL WITH


CONNECTION DETAILED SECTION
400(MM)

DOWEL BARS TO MATCH DOWEL BARS TO MATCH 12Ø @300 O.C.


10MM Ø @ 300 MM O.C. B.W. 5
VARIES
(MIN)

(min)
480

CHB VERTICAL BARS CHB VERTICAL BARS 1742


480

3-12Ø CONT. BARS


5-12Ø BARS AS SHOWN
S 02 SCALE: NTS
300(MM)

F.F.L.
200

2-10MMØ
200

CONT. BARS
12Ø @ 300 O.C. MIDDLE 10MM DIA. TEMP. BARS 10MM DIA. TOP BARS @ 100MM
100

600 200
2-16MMØ
@ 300MM O.C. O.C. (SHORT SPAN END SUPPORT)
CONT. BARS
100 200 100 TOP & BOT. L/5 L/4
EXTERIOR WF FTB SUPPORTED CHB WALL
INTERIOR WF 50MM THICK GRAVEL FILL DISCONTINUOUS CONTINUOUS

COMPACTED SOIL

100
3 WALL FOOTING DETAILS 4 DETAIL OF SLAB ON FILL
S 02 SCALE: NTS S 02 SCALE: NTS BEAM
10MM DIA. TEMP. BARS
@ 300MM O.C.
10MM DIA. BOTTOM
BARS @ 100MM O.C.
L/7 L/6
(MID OF SHORT SPAN)

S-1
6 RC SLABS ONE-WAY REINFORCED
S 02 SCALE: NTS

CIVIL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


ROOF FRAMING PLAN
STEEL TRUSS DETAIL S-2
PROPOSED TWO STOREY RESIDENTIAL BUILDING WALL FOOTING DETAILS
DETAIL OF SLAB ON FILL 5 3
PRC REG. NO. : PTR NO. : Location: CONNECTION DETAILED SECTION
T. I. N. : ISS. ON : RC SLABS ONE-WAY REINFORCED STRUCTURAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
)
(W

L
4

)
4

W
4

(W
AN

W
SP
AN
LO LO
SP

NG O RT NG
T

S
R

SP SH PA
O
SH

AN N(
(L) L)
4

W
W
4

SECOND

L
4
FLOOR

300
SB
150

GROUND
FLOOR

250

250
200

800

300
2 DETAILED SECTION OF STAIRCASE
DETAIL OF ONE-WAY SLAB (S-1) DETAIL OF TWO-WAY SLAB (S-2) S 05 SCALE: NTS

12mm DIA. SAG RODS WEB MEMBERS


1 DETAIL OF SLABS (PLAIN ROUND BAR)
WITH DOUBLE NUTS
LC - 2"x5"x1.5mm THK
INTERMEDIATE PURLIN
6mm

S 03 SCALE: NTS

3
L - 2"x2"x16 "
CLIP ANGLE FULLY
BOTTOM CHORD
WELDED TO TOP CHORD

TOP CHORD MEMBER TYPICAL WEB MEMBERS


TYPICAL PURLIN TO BOTTOM CHORD LC - 100x50x15x2mm
INTERMEDIATE
SPACED

10mm
(PLAIN
(1
@ 0.60m

LINEØROUND
PER
PURLINS

SAGBAY)
RODS
O.C.

BAR)
"2LB -TO
TOP
4
1 3"

"2LB -TO
BOTTOM
4
1
CHORD
xB 3" x MEMBERS

3" xB 3"CHORD
x MEMBERS
"3122L
AUXILLIARY
6B
x -1TO

"2LB -TO
WEB
4
1
1 B MEMBERS

2"MEMBERS
xB 2" x

CANTILEVER L1 L2 TOP CHORD


16mm DIA. TIE ROD
L1 / 4 L1 / 4 L2 / 4 L2 / 4 (PLAIN ROUND BAR)
BAR "C" EXTRA TOP BAR "C" EXTRA TOP WIDTH
BAR "A" CONT. TOP B
BAR "E" STIFF. BARS 12mm DIA. SAG ROD
TOP BARS (WITH DOUBLE NUTS) TOP CHORD
STIRRUPS
D

DEPTH
STIFF. BARS
D
6mm
BAR "D" EXTRA BOT. BAR "D" EXTRA BOT.
BAR "B" CONT. BOT. BAR "B" CONT. BOT. BOT. BARS WEB MEMBERS
L1 / 5 L1 / 5 L2 / 5 L2 / 5

SPACING OF STIRRUPS SPACING OF STIRRUPS


EXT. SUPP. EXT. SPAN INT. SUPP. INT. SPAN INT. SUPP. WEB MEMBERS

TYPICAL WEB MEMBERS


TYPICAL RIDGE PURLIN
3 TYP. RC BEAM ELEVATION TO TOP CHORD
S 03 SCALE: NTS

4 CONNECTION DETAILS
S 03 SCALE: NTS

CIVIL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


DETAIL OF SLABS
DETAILED SECTION OF STAIRCASE S-3
PROPOSED TWO STOREY RESIDENTIAL BUILDING TYP. R.C. BEAM ELEVATIONS
CONNECTION DETAILS 6 13
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : STRUCTURAL
ISS. AT : INDANG, CAVITE CADD BY: LER DATE: JULY 2015 PROJECT No.:
SCHEDULE OF BEAMS GENERAL NOTES
SPACING OF SPACING OF GENERAL:
SECTION END - SECT REBARS MID - SECT REBARS 6. UNLESS OTHERWISE NOTED IN PLANS OR SPECIFICATIONS, CAMBER ALL BEAMS AND
STIRRUPS STIRRUPS A. MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE
GIRDERS AT LEAST 62 mm FOR EVERY 3.00m OF SPAN EXCEPT CANTILEVERS FOR WHICH
FOLLOWING BUILDING CODE. THE CAMBERS SHALL BE AS NOTED IN THE PLANS OR ORDERED THE DESIGNER, BUT IN
1. AC I 318-11
3 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B. 2. A1SC 2011 NO CASE LESS THAN 6.7mm. FOR EVERY 3.00M OF FREE SPAN.
A = < 2 > METERS

B-1 10 DIA. MM STIRRUPS 3. NSCP 2010


300

300
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B. B,C,D 2 @ 50 MM

2 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
2 @ 75 MM
2 @ 100MM
B. ALL DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES UNLESS CONCRETE HOLLOW BLOCKS:
REST @ 200 MM O.C. OTHERWISE INDICATED REINFORCEMENT AS TABULATED BELOW SHALL BE PROVIDED UNLESS OTHERWISE
200 200
C. FOR ALL OTHER REQUIREMENTS, REFER TO ARCHITECTURAL, SANITARY, ELECTRICAL
AND MECHANICAL WORKING DRAWINGS. SPECIFIED IN THE PLAN
B= 3 METERS
5 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
10 DIA. MM STIRRUPS
2 @ 50 MM FOOTINGS: CONCRETE HOLLOW BLOCKS REINFORCEMENT
3 @ 75 MM
1. FOOTINGS ARE DESIGNED ON NATURAL GRADE LINE WITH A MIN. BEARING CAPACITY
300

300
B-2
2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
D,E 3 @100 MM BLOCK REINFORCEMENT NOTES
REST @ 200 MM O.C. OF 144 KPa.
3 - 16 MM Ø D.R.B. 5 - 16 MM Ø D.R.B.
2. NO FOOTING SHALL REST ON FILL. THK. HORIZONTAL VERTICAL
200 200
C = 4 METERS 3 MINIMUM CONCRETE PROTECTION FOR REBARS SHALL BE 0.076m. CLEAR FOR
10 DIA. MM STIRRUPS CONCRETE DEPOSITED AGAINST THE GROUND AND 0.05m. CLEAR FOR CONCRETE DEPOSITED
2 @ 50 MM AGAINST THE FORM WORK.
FREE-END 4 @ 75 MM
4 @ 100 MM
3 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.
REST @ 200 MM O.C. CONCRETE MIXES & PLACINGS :
300

300

2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
B-3 A,B,C,D 1. UNLESS OTHERWISE SPECIFIED, THE MINIMUM 28 DAYS CYLINDER COMPRESSIVE
2 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B. D = 5 METERS STRENGTH ARE AS FOLLOWS.
200 200
10 DIA. MM STIRRUPS
2 @ 50 MM
FOOTINGS & BEAMS ON GRADE---------------------------------------21.0 MPa
CONCRETE SLABS:
5 @ 75 MM
5 @ 100 MM COLUMNS------------------------------------------------------------------21.0 MPa 1. ALL REINFORCEMENT SHALL BE 0.019m CLEAR MINIMUM FROM TOP AND BOTTOM OF SLAB.
REST @ 200 MM O.C. SLAB, BEAMS & GIRDERS-----------------------------------------------21.0 MPa 2. FOR TWO- WAY SLAB BARS ALONG SHORTER SPAN SHALL BE PLACED BELOW THOSE ALONG
FREE-END PARTITIONS, PARAPET & SHEAR WALL-------------------------------21.0 MPa THE LONGER SPAN .AT CENTER AND OVER THE LONGER SPAN BARS NEAR THE SUPPORT
5 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B. BEDDED SLABS, CATCH BASINS & SIDE WALK----------------------17.5 MPa UNLESS OTHERWISE INDICATED OR SHOWN IN DETAILS THE SPACING OF THE BARS AT THE
E = < 5 > METERS
B-4 C,D 10 DIA. MM STIRRUPS COLUMN STRIPS CAN BE APPROXIMATELY 1-1/3 OF THE MIDDLE STRIPS BUT IN NO CASE
300

300

2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
7 @ 50 MM 2. ALL CONCRETE MUST BE DEPOSITED, VIBRATED AND CURED IN ACCORDANCE WITH
ACT STANDARD 318-89. GREATER THAN 2-1/3 TIMES THE SLAB THICK.
7 @ 75 MM
3 - 16 MM Ø D.R.B. 5 - 16 MM Ø D.R.B.
7 @ 100 MM 3. STRIPPING FORMS AND SHORES SHALL BE AS FOLLOWS 3. UNLESS OTHERWISE SHOWN IN DETAIL FOR ONE WAY SLAB, REINFORCING BARS SHALL BE
200 200 REST @ 200 MM O.C. BEND, EXTENDED OR CUT AS FOLLOWS. NO CASE LESS THAN 6.7mm. FOR EVERY 3.00M.
FOUNDATIONS I DAY OF FREE SPAN.
COLUMNS & WALLS 3 DAYS
FREE-END FREE-END BEAMS & GIRDER 21 DAYS
B,C,D SLABS 17 DAYS
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.

B-5 4. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION RE-HANDLING
300

300

2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
OR FLOWING, PLACING- SHALL BE DONE PREFERABLY WITH BUGGIES BUCKETS OR WHEEL
3 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B. BARROWS. NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS
200 200 TO BUGGIES, WHEELBARROWS, OR BUCKETS IN WHICH CASE THEY SHALL NOT EXCEED 600m IN
AGGREGATE LENGTH, NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF
VIBRATOR - UNLESS AUTHORIZE IN WRITING BY THE DESIGNERS AND ONLY FOR USUAL
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.
CONDITIONS WHERE VIBRATOR IS EXTREMELY DIFFICULT TO ACCOMPLISH.
RB-1
300

300

2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
B,C,D
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.

200 200 BEAMS & GIRDERS:


EXTERIOR SPAN INTERIOR SPAN INTERIOR SPAN CANTILEVER
1. CAMBERS ALL BEAMS AND GIRDERS AT LEAST 62mm. FOR EVERY 3.00 m.
3 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B. OF SPAN.
2. FOR TWO OR MORE LAYERS OF REINFORCING BARS, USED SEPARATOR SPACED AT 0.914 M.
RB-2
300

300

2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B. O.C AND IN NO CASE SHALL BE LESS THAN TWO (2) SEPARATORS.
D,E 3. NO SPLICE SHALL BE PERMITTED ON BEAMS AND GIRDERS WHERE CRITICAL BENDING STRESSES
2 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
OCCUR TENSION SPLICE SUPERMITTED SHALL BE 48 DIAMETER FOR PLAIN BARS AND 24 MILD STEEL REINFORCEMENT:
200 200 DIAMETER FOR DEFORMED BARS, COMPRESSION SPLICE SHALL BE 40 DIA. FOR PLAIN BARS 1. ALL MILD STEEL REINFORCEMENT SHALL CONFORM TO ASTM A-15-62-21 AND DEFORMATIONS
FOR PLAIN BARS AND 20 DIA. FOR DEFORMED BARS LAP SPLICES SHALL BE WIRED
FREE-END TOGETHER SPLICE TOP BARS AT MID SPAN BOTTOM BARS AT SUPPORT BENT BARS TO A REVISIONS.
3 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B. AT BEND POINTS IN SUPERSTRUCTURE WELDED SPLICES SHALL BE DEVELOPED 2. DEVELOPMENT LENGTH FOR ALL BARS SHALL BE A MINIMUM OF 40 BARS DIA. UNLESS
INTENSION AT LEAST 125 Ø OF THE SPECIFIED YIELD STRENGTH OF THE BAR NOT OTHERWISE SPECIFIED.
RB-3
300

300

2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
D,E MORE THAN 50 % OF THE BARS AT ANY ONE SECTION SHALL BE PERMITTED
2 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
TO BE SPLICED.
4. IF BEAM REINFORCING BARS END IN A WALL THE CLEAR DISTANCE FROM THE BAR TO 12 ; Fy= 225 MPa
200 200
THE FURTHER FACE OF THE WALL SHALL NOT BE LESS THAN 0.051m EMBEDMENT STRUCTURAL STEEL: 16 ; Fy= 275 MPa
LENGTH SHALL BE 40. DIA FOR TENSION AND 20 DIA. COMPRESSION BARS.
3 - 16 MM Ø D.R.B. 3 - 16 MM Ø D.R.B.
5. MINIMUM CONCRETE PROTECTION REINFORCING BARS OR SHAPE SHALL BE AS SHOWN 1. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A-36 Fy= 36,000 PSI
2. WELDING SHALL CONFORM TQ AWS STANDARDS .
CB
300

300

2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B.
D,E 3. FABRICATOR SHALL SUBMIT SH0P DRAWINGS FOR APPROVAL BY THE ENGINEER
2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B. AND THE OWNER PRIOR TO FABRICATION.
200 200

2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.
300

300

FTB 2 - 10 MM Ø D.R.B. 2 - 10 MM Ø D.R.B. A,B,C,D


2 - 16 MM Ø D.R.B. 2 - 16 MM Ø D.R.B.

200 200

CIVIL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


SCHEDULE OF BEAMS
GENERAL NOTES S-4
PROPOSED TWO STOREY RESIDENTIAL BUILDING
7 13
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : STRUCTURAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
A B C D E F A B C D E F A B C D E F
C1 D1 E1

R O O F L I N E
3 12

1 1 1
S1
LAV
S1 S1 EF EF
LAV

1700
LAV LAV
EF S1
2000

2000
S1
5
1' 6
2 2 2
S2 10

5000
3300
3000

3000
S2 S2

3500

3500
S2
9
7
3 3 S2W S1 3
POWDER LPP POWDER
ROOM DN ROOM
EF
S1

2425

2500
2500

BAR BAR

3500

14000
14000

UP UP

3500
3500
S2W S1 T&B
S2
4 S1
Sc
S2 4 4
c c LPP1 8 4
11
S1

2000
S1
S2 S2
S1
S1 S1
Sa a a 4' a
4700

4700
b b a a
Sa
S1

3200

3200
5000
4075
a S1
a S2 Sab a a 8
5 1 S2 S2 S S1 5 Sa 5
2 a
S1 a a

1800

1800
1800

1800

5'
6 6 6
3500 2000 3500 1000 5000 4000 3500 2000 3500

9000 4000 9000 9000


3000

3000
2 SECOND FLOOR LIGHTING LAYOUT
E 01 SCALE: 1:100 METERS

1 GROUND FLOOR LIGHTING LAYOUT 1 GROUND FLOOR POWER LAYOUT


E 01 SCALE: 1:100 METERS E 02 SCALE: 1:100 METERS

ELECTRICAL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


GROUND FLOOR LIGHTING LAYOUT
SECOND FLOOR LIGHTING LAYOUT E-1
PROPOSED TWO STOREY RESIDENTIAL BUILDING GROUND FLOOR POWER LAYOUT
8 13
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : ELECTRICAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
A B C D E F A B C D E F A B C D E F
C1 D1 E1 C1 D1 E1

R O O F L I N E R O O F L I N E

1 21 22 1 LAV
INTERCOM
1

1700
LAV LAV

1700
LAV LAV

2000
1' INTERCOM
1'
2 2 2

5000

5000
3300

3300
3000

3500
19 14 18

3 17 3 3
POWDER
DN ROOM
DN
2425

2500

2425
INTERCOM
BAR

3500

3500
14000
UP

3500
T&B T&B
4 4 4
LPP1
INTERCOM
20 CCTV &
OFFICE OFFICE
2000

2000
INTERCOM
16 INTERCOM
CONTROL &
MONITOR
4' 4'

4700
INTERCOM
13
WALK-IN WALK-IN

3200
MASTER MASTER
CLOSET CLOSET

5000

5000
BEDROOM BEDROOM
4075

4075
5 15 5 5

1800

1800
5' 5'
6 6 6
1000 5000 4000 3500 2000 3500 1000 5000 4000

4000 9000 9000

3000
4000 9000

2 SECOND FLOOR POWER LAYOUT SECOND FLOOR CCTV &


E 02 SCALE: 1:100 METERS
GROUND FLOOR CCTV & 2 INTERCOM SYSTEM LAYOUT
E 03 SCALE: 1:100 METERS
1 INTERCOM SYSTEM LAYOUT
E 03 SCALE: 1:100 METERS
32 mm DIA. ENTRANCE CAP

M LPP1 2 - 50 mm ² THHN + 1 - 8.0 mm ² THW


( ground wire ) IN 50 mm Ø IMC

1 " DIA., 3 WIRE, 230V, MECO


175 AT,300AF
SUPPLY
50 mm DIA. COND. CLAMP
15AT 15AT
12mm DIA. OVAL EYE 2 - 50.0 mm ² THHN + 1 - 8.0 mm ² THW L.O. 01 02 L.O.
( ground wire ) IN 50 mm Ø IMC PANEL 15AT 20AT
L.O. 03 04 C.O.
"LPP1" 20AT 30AT
C.O. 05 06 C.O.
175AT, 40AT 30AT
KWH METER 300 AF, 08 RACU OUTLET
M 240 V,
ELECTRIC RANGE 07
30AT 30AT
2P CB RACU OUTLET 09 10 REFRIGERATOR
15AT 15AT
CONCRETE PEDESTAL
L.O. 11 12 L.O.
OUTDOOR BREAKER 30AT 30AT
175 AT, 300 AF, 240 V, 2P CB C.O. 13 14 C.O.
2 - 50.0 mm THHN
1 - 8.0 mm THW 30AT 30AT
in 50 mm DIA. IMC RACU OUTLET 15 16 RACU OUTLET
FIRST FLOOR 30AT 30AT
WATER HEATER 17 18 RACU OUTLET
30AT 30AT
RACU OUTLET 19 20 RACU OUTLET
30AT 30AT
WATER HEATER 21 22 WATER HEATER
15AT 15AT
SPARE 23 24 SPARE
PROVIDE STUBOUT PROVIDE STUBOUT

POWER FEEDER SINGLE LINE DIAGRAM BOARD PANEL DETAILS


GROUND

ELECTRICAL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


SECOND FLOOR POWER LAYOUT
GROUND FLOOR CCTV & INTERCOM LAYOUT E-2
PROPOSED TWO STOREY RESIDENTIAL BUILDING SECOND FLOOR CCTV & INTERCOM LAYOUT
POWER FEEDER SINGLE LINE DIAGRAM 9 13
PRC REG. NO. : PTR NO. : Location: BOARD PANEL DETAILS
T. I. N. : ISS. ON : ELECTRICAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
GENERAL NOTES AND SPECIFICATIONS
1. ALL WORKS HEREIN SHALL COMPLY WITH THE PROVISION OF THE LATEST EDITION
OF THE PHILIPPINE ELECTRICAL CODE WITH THE RULES AND REGULATION OF THE
L0CAL AUTHORITIES CONCERNED IN THE ENFORCEMENT OF ELECTRICAL LAWS AND
ORDINANCE AND WITH THE RULES AND REGULATION OF MERALCO.

2. THE SERVICE ENTANCE SHALL BE THREE PHASE, FOUR WIRE, 13.4 KV, 60 HZ.

3. ALL MATERIALS AND EQUIPMENT TO BE USED SHALL BE NEW AND APPROVED TYPES
OF THE LOCATION AND PURPOSE.

4. ALL BRANCH CIRCUIT SHALL BE INSTALLED AS INDICATED IN THE PLANS, INDIVIDUAL


BRANCH CIRCUIT, HOMERUNS SHALL NOT BE COMBINED IN THE SAME RACEWAY.

5. MOUNTING HEIGHT FOR LIGHT SWITHES AND BUTTON SHOULD BE 1.4 METERS
ABOVE FLOOR LEVEL.

6. MOUNTING HEIGHT FOR CONVENIENCE OUTLETS SHOULD BE 0.30 METERS


ABOVE FLOOR LEVEL.

7. MINIMUM SIZE OF CONDUCTORS SHALL BE 3.5 MM² COPPER WIRE, THW.

8. ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION


OF A LICENSED ELECTRICAL ENGINEER OR MASTER ELECTRICIAN.

LEGENDS
CIRCUIT HOMERUN

LPP
PANEL BOARD M KILOWATT HOUR METER

AIR CIRCUIT BREAKER


SERVICE ENTRANCE
SWITCH SINGLE GANG, 15A, 300V, SINGLE POLE,
S1 WITH MOUNTING STRAP AND DEVICE PLATE COVER.
CONVENIENCE OUTLET
S2 SWITCH TWO GANG, 15A, 300V, SINGLE POLE,
WITH MOUNTING STRAP AND DEVICE PLATE COVER.
A.C.U.
AIRCONDITIONING UNIT

CCTV
INTERCOM

ELECTRICAL ENGINEER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


SCHEDULE OF LOADS
GENERAL NOTES AND SPECIFICATIONS E-3
PROPOSED TWO STOREY RESIDENTIAL BUILDING LEGENDS
1013
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : ELECTRICAL
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
A B C D E F A B C D E F A B C D E F
C1 D1 E1

R O O F L I N E

10
100 MMØ DP/SP 100 MMØ DP/SP 100 MMØ DP/SP WR
1 1 1 1/2"Ø CWL 1/2"Ø CWL

50

0M
CO

MM

50

50

50


10

50

50
SS SS
CB 50LAV CO CB CB

0M
Ø

MM

MM

MM
LAV

MM

SP

MM
MM

DP


100 MMØ DP/SP

Ø
50 Ø D

Ø
DP

DP

DP
DP

DP
MM P

SP

1/2"Ø CWL
FD FD

100 MMØ DP/SP


Ø
FD DP

1700
FD

1/2"Ø CWL
LAV LAV FD WC

1/2"Ø CWL
2000
2000
10 WC WC
0M

SP
WC

DP
FD SHO
LAV
1'

Ø
MM
100 MMØ DP/SP 100 MMØ DP/SP LAV
2 CO
2 2 1/2"Ø CWL

50
100 MMØ DP/SP
CB CB

5000
DP
SEPTIC MM
Ø
50
TANK
FD SINK DP
Ø
MM

100 MMØ DP/SP


3300
50

3000

1/2"Ø CWL
3000

DP
Ø USE 12" Ø PIPE CWL

100 MMØ DP/SP


MM

100 MMØ DP/SP

3500
3500
50 FOR ALL FIXTURES
SINK

CB
3 LAV 3 DP 100 MMØ DP/SP
3
DP CO DP MØ

1/2"Ø CWL
50 POWDER Ø M POWDER
Ø MM 50
MM ROOM MM DN ROOM

1/2"Ø CWL
Ø 50 50
10 DP FD FD
0M
MØ LAV DP FD DP LAV
Ø Ø
SP WC FD MM MM

2425

2500
2500

CO BAR 50 CO
FD
50
BAR
150 MMØ DP/SP

3500

14000
14000

UP UP
DP

3500
3500
CB T&B 50
M

4 4 4

50 MMØ DP
FD 1/2"Ø CWL
LAV DP
Ø
MM

10
50 HB

0M
WC


OFFICE

2000
CO CO

SP
CB
CB 4' FD

4700
4700

FD
150 MMØ DP/SP

WALK-IN

3200
3200
MASTER
CLOSET

5000

1/2"Ø CWL
BEDROOM

4075
CB
5 5 5

1800

1800
1800

1800
FD
FD
CB
5'
CB
6 6 6
150 MMØ DP/SP

CB CB

1/2"Ø CWL
3500 2000 3500 1000 5000 4000 3500 2000 3500

9000 4000 9000 9000

3000
3000

HB

GV
2 SECOND FLOOR PLUMBING LAYOUT WM

TAP TO THE NEAREST P 01 SCALE: 1:100 METERS TAP TO THE


TAP TO THE NEAREST SEWERAGE/CANAL NEAREST SOURCE
SEWERAGE/CANAL OF WATER SUPPLY

1 GROUND FLOOR PLUMBING LAYOUT 1 GROUND FLOOR WATER SUPPLY LAYOUT


P 01 SCALE: 1:100 METERS 3000 P 02 SCALE: 1:100 METERS
2700

150 1650 150 600 150

150mm thick CHB Wall

150mm thick CHB Wall


150mm thick CHB Wall

ELBOW 50mm dia.


1500

150mm thick CHB Wall


1200

GATE VALVE 50mm dia. .05 0.20 .05


FLAT BAR
GRATING COVER WATER CLOSET
WATER METER 50mm dia. (REFER TO ARCH'L)

COUPLING BOLT & NUTS FESEAL GUM


PLAN
UNION PATENTE TOILET FLR. FIN. PART OF WATER CLOSET

TEE 50mm dia.


75

FESEAL GUM
TEST FAUCET
FLOOR FLANGE (BRASS/PVC) FLOOR FLANGE
REDUCER/BUSHING
1725

1500

100mm dia. DRAIN PIPE


1200

50mm dia. PIPE BOR PLUS PIPE


150mm THICK CHB
WITH 10mm DIA. HORIZONTAL BARS

FLOOR DRAIN DETAIL


EVERY 3 LAYERS;
AND 10mm DIA. VERTICAL BARS
AT 600mm O.C.
50mm THICK SAND BEDDING BOR PLUS PIPE
75

TO SUPPLY
75

COMPACT EARTH
SECTION DETAIL OF WATER CLOSET CONNECTION
3 WATER METER DETAIL DETAILS OF SEPTIC TANK
P 02 SCALE NTS SCALE NTS

MASTER PLUMBER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


GROUND FLOOR PLUMBING LAYOUT
SECOND FLOOR PLUMBING LAYOUT P-1
PROPOSED TWO STOREY RESIDENTIAL BUILDING GROUND FLOOR WATER SUPPLY LAYOUT
PLUMBING DETAILS 1113
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : PLUMBING
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
DS 1 A
A B C D E F
C1 D1 E1 2 1'
170
B
R O O F L I N E 0
SH
R O
O
O 3 WH
C
DS
F 330 1/2" WR C1
1 1/2"Ø CWL 1/2"Ø CWL 1/2"Ø CWL DS

L
0
1/2"
D
WH WH Ø CW
I
SHO SHO
N 4 WC
LF

1700 WC LAV LAV E WC


R D1
WC
USE 21" Ø PIPE CWL USE 21" Ø PIPE CWL
WC
5
242 LA
V
O E
FOR ALL FIXTURES FOR ALL FIXTURES 1/2"
Ø CW
O

1' 4' US
FO
R EA
L F
200 2 "1
Ø
LL PIP L E1
2 DS
DS
0 FIX E
TU CW
RE L
I
N
5

1/2"Ø CWL
S

5000
DS
E
US
FO
RE2 "1 Ø
AL P
1/2"
Ø CW
LF
WH
SH
O F
L F IP
6 5' 407 IXTE C
3300

5 UR WL LA
DN ES V
WC
OF SH
OW
DS
FIC H

DS
E SH
O

3 1/2"Ø CWL

BE MAS Ø CW
L 1/2"
Ø CW
L
1/2"
Ø CW
L

1/2"
DN
WH
DR TE
OO R
500
SHO 0
400 0
SHO
M WC T&
2425

DS
100
0
B F

1/2"Ø CWL
USE 12" Ø PIPE CWL F L

3500
CW

1/2"Ø CWL
FOR ALL FIXTURES DS Ø
1/2"
LA
W V

T&B CL AL
OS K-I
350
4
0
500 0
LAV ET N
WC

OFFICE 1 A
2000

0
DS 900

2 1'
0
400
0
500

4' 170
B
0

WALK-IN 3 C 1 A
MASTER
CLOSET
330 SS C1
D

5000
0
BEDROOM

50 MMØ
2

100 MMØ
4 FD
4075

DP

50 MMØ
100
D1

50 MMØ
WC FD MM 200
Ø DP R

SP
242 LA /SP E 0

DP
5 V O

DP
5 O US
FO
REA1
C
4' F 3 2"
Ø
LL PIP
200 L E1 300 FIX E
TU CW 1/2 W
" R
0
100
I
N
0 RE L
S
L
1/2"
Ø CW
D
5' 5 M MØ
DP
/SP
E
F 4 1/2"
Ø CW L
F
FD SH
O L
E

50 MMØ
250
6 6 5'
140 0 1/2"
Ø CW LA
V

100 MMØ
407

50 MMØ
00
5 100 WC
LA MM
DN V FD

DP
Ø DP
1/2"

50 MMØ
DP
/SP HB Ø CW

SP
FD WC F
1000 5000 4000 OF FD CO
L

DP
FD
FIC Ø CW
L

4000 9000 E CO 5 470 1/2"


Ø CW 1/2"
P
ROOWD
F
0 L
OM ER L

SECOND FLOOR WATER SUPPLY LAYOUT Ø CW


50 MMØ DP
FD 1/2"
2 BE MAS /SP 6 L F
FD 50 MMØ DP Ø CW
DR TE Ø DP
MMFD
100 M MØ
DP
3/4"
P 02 SCALE: 1:100 METERS 0
400
FD
OO R CO
50 MMØ
DP
100
0
500
180 LA
T& /SP

100 MMØ
V
M
0
WC
UP 1/2"
B
0
100 US
FO
Ø CW

B C D E F FD 50 MMØ DP R EA

SP
1
2" L
Ø
L LL PIP
300 HB Ø CW FIX E F
50 MMØ DP 3/4" TU CW
D1 E1
0
C1 W
CL AL
LA
V
50 MMØ DP
RE L
S

OS K-I CO
0 350
12000 500 WM GV SIN L
BA CW
0 K
ET N
Ø
1/2"
OF NEARTAP R F
1000 10000 1000 WA EST TO
TE SO THE
R O O F L I N E R S UR LA
V L
0 UP CE Ø CW
900 PLY 1/2" 350
DS DS DS 0
1000

1000

500 0
0
400
0 350
1
350
0
0
200 00
90

1' 1 A 320
2 0
350 0

2
200 B 180
0
0

3 C
300
S CB SS
TAEPT D
0
/SP
NK IC MM
Ø DP
100
11475

4
9475

DS DS
CB
3
WATER SUPPLY LAYOUT ISOMETRIC
100 LA
E

50 MMØ
250 V
140 M CO
2

50 MMØ
MØ FD
/SP
00 0
DP

100 MM
/SP DP
/SP MØ

DP
DP 0M
/SP MØ

DP
Ø DP M FD WC10

Ø SP
150
MM 100
P 02 SCALE: 1:100 METERS
LA

50 MMØ
Ø DP V 100
5 MM CO
100 MMØ
13500

15500

470 MM
150 FD PO Ø DP
F
0 RO WD /SP
CB
DP
WC OM ER
/SP
SP

Ø DP

4 6 15 0M
M
100 VARIES(300 MIN) 100
LA
V 50
180 50 MMØ DP 50

50
0 DP

100
Ø 100
MM UP MM
150 Ø DP CB
CB /SP

50
/SP

100
Ø DP
MM
300

VARIES (300 MIN)


0 150 FD 50 MMØ DP CO
CB SIN
K
4' 50 MMØ

VARIES
DP
Ø DP
MM 50 MMØ DP
150
BA

VARIES (300 MIN)


T
SEAP TO
1000

DS
WE T R CB
/SP
RA HE CB FD 50 MMØ DP Ø DP
DS DS GE N LA MM
/CA EAR V 100
NA ES 50 MMØ DP 350
1000 L T CO 0

100

50
Ø DP
0
350 MM
150
CB
50 50

100
CB
5
350
0
VARIES (300 MIN)
4025

0 100 100
200 00
90
M Ø DP
150M

5' 0
350
320
0 PLAN SECTION
CB
1000

6
DS DS DS

DETAIL OF AREA DRAIN/


180
0
1000 9000 1000 M Ø DP
15 0M

10000
T
SEAP TO
WE T
CATCH BASIN
RA HE
2 AREA DRAIN LAYOUT GE NE
/CA AR
NA ES
L T
2 PLUMBING LAYOUT ISOMETRIC
P 02 SCALE: 1:100 METERS P 02 SCALE: 1:100 METERS

MASTER PLUMBER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


SECOND FLOOR WATER SUPPLY LAYOUT
AREA DRAIN LAYOUT
P-2
PROPOSED TWO STOREY RESIDENTIAL BUILDING PLUMBING LAYOUT ISOMETRIC
WATER SUPPLY LAYOUT ISOMETRIC 1213
PRC REG. NO. : PTR NO. : Location: DETAIL OF AREA DRAIN/CATCH BASIN
T. I. N. : ISS. ON : PLUMBING
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.:
GENERAL NOTES
1. ALL PLUMBING INCLUDED HEREIN SHALL BE EXECUTED
IN ACCORDANCE WITH THE PROVISION OF THE PHILIPPINES
FIN. FLOOR FINISH PLUMBING CODE AND THE RULES AND REGULATIONS OF THE
WATER PROOFING
MEMBRANE
(BY OTHERS)
50MM DIA. VENT PIPE

SANITARY TEE
CITY CONCERN.
COUNTER SUNK FLOOR
CLEANOUT "METMA"
THREADED MODEL M-335-B

ESCUTCHEON FINISH FLOOR LEVEL

TUBULAR OUTLET
2. COORDINATE THE DRAWINGS WITH OTHER RELATED
TAIL PIECE OF DRAIN
DRAWINGS AND SPECIFICATIONS. THE ENGINEER SHALL
SLIP JOINT NUTS

FLOOR DRAIN BODY


SLIP JOINT WASHER
BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND
SECTION A
THEREIN.
PIPE SIZE SCHEDULE OF DIMENSIONS SLIP JOINT NUTS

PIPE DIMENSIONS IN MM. SLIP JOINT WASHER SECTION


TRAP BODY
SIZE
IN 'A'

50
C

38.10
D

101.60
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS.
75 38.10 127.00 ANY RELOCATIONS REQUIRED FOR PROPER EXECUTION OF
100 40.00 152.40

PLAN 150 50.80 177.80


SLIP JOINT WASHER

FINISH FLOOR LEVEL


TRADES SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT.
CLEAN OUT CAP

BOR PLUS COUPLING


METALS OR APPROVED EQUIVALENT 90 DEGREE BOR PLUS

TOILET FLOOR FINISHED


ELBOW
90 DEGREE BOR PLUS
COUNTER SUNK FLOOR
CLEANOUT "METMA"
TURN BUCKLE
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE
ACTUAL DEPTH AND INVERT ELEVATIONS OF ALL EXISTING
ELBOW MODEL M-335-B
HANGER ROD

BOR PLUS PIPE

WIRE MESH
(vent thru roof)
NO-HUB COUPLING
line of joint BOR PLUS-PVC)
SEWER AND DRAINAGE AS VERIFIED BY THE CONTRACTOR.
PIPE CLAMP
LATERAL/BRANCH
SECTION SOIL PIPE (SP)

BOR PLUS PIPE

5. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN


PIPE CLAMP
from system 1% MINIMUM UNLESS OTHERWISE SPECIFIED.
DETAIL OF PVC TO G.I 10 CLEAN OUT DETAILS
5 DETAIL OF FLOOR DRAIN CONNECTION @ VTR
P 02 SCALE NTS
6
P 02 NTS
P 02 SCALE NTS
6. SIZES OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN
SCALE
ACCORDANCE WITH THE MANUFACTURING INSTRUCTIONS.
CAP
7. THE CONTRACTORE SHALL VERIFY ALL EXISTING UTILITIES
AT SITE AND COORDINATE THE WORKS WITH THE EXISTING
1/2"Ø CAP PLUG DRAINAGE EFFLUENT LINE AND WATER CONNECTION LINE.
AIR CHAMBER

AIRCAPPED
CHAMBER CONCRETE SLAB

ABBREVIATIONS:
0.30

1/8"Ø FLEX. SUPPLY PIPE


EXPANSION SHIELD OR
ANGLE VALVE BULLET AND DRIVE PIN WC WATER CLOSET FD FLOOR DRAIN
HANGER ROD 3/8"0 FOR 2"0 - 6"0 PIPE,
1/2" x 3/8" BUSHING BIGGER PIPE SIZE - USE 1/2"0 ROD LAV LAVATORY SD SHOWER DRAIN
PEAR HANGER GALVANIZED IRON
1/2" Ø TEE
TEE
TO FIXTURE
GAUGE 20 x 1 1/4" WIDTH SHO SHOWER MH MANHOLE
PIPE PREFERABLY @ 1.5 m UNSUPPORTED
AD AREA DRAIN CWL COLD WATER LINE
9 DETAIL OF PIPE HANGER SS SLOP SINK VSTR VENT STACK THRU ROOF
AIR CHAMBER DETAIL P 02 NOT TO SCALE
EC END CAP
DETAIL OF AIR VS VENT STACK
8 CAPPED CHAMBER ST SEPTIC TANK
SP SOIL PIPE
NOT SCALE
P 02
BV BALL VALVE
CV CHECK VALVE
F FAUCET
CO CLEAN OUT

MASTER PLUMBER: PROJECT: OWNER: REMARKS: SHEET CONTENT: SHEET NO.:


PLUMBING DETAILS
GENERAL NOTES P-3
PROPOSED TWO STOREY RESIDENTIAL BUILDING ABBREVIATIONS
1313
PRC REG. NO. : PTR NO. : Location:
T. I. N. : ISS. ON : PLUMBING
ISS. AT : CADD BY: LER DATE: JULY 2015 PROJECT No.: