Indian Standard
SAFETY OF HOUSEHOLD AND SIMILAR
ELECTRICAL APPLIANCES
PART 2 PARTICULAR REQUIREMENTS
UDC 641.539
@ BIS 1994
FOREWORD
This Indian Standard was adopted by the Bureau of Indian Standards, after the draft finalized by
the Electrical Appliances Sectional Committee had been approved by the Electrotechnical
Division Council.
This standard specifies general and the safety requirements. The composite standard specifying the
requirement of safety and performance requirements are covered under IS 11676-1986 Specifica-
tion of microwave ovens for household and similar purposes.
This standard is to be read in conjunction with IS 302-I ( 1979 ) Safety of household and similar
electrical appliances : Part 1 General requirement’. For the sake of convenience, the clauses of
this standard correspond to those of 1s 302-l ( 1979 ) instead of reproducing full text of each
clause, clauses of IS 302-l ( 1979 ) which are applicable ( which means that relevant provisions of
the clause apply ) or not applicable and the subclause or portions thereof which are not applicable
are indicated as under:
a) In the case of a clause where it is applicable or not applicable, the wording used is ‘This
clause of 1s 302-I ( 1979 ) is applicable/not applicable’.
b) In case of a subclause or part thereof ‘not applicable’ wherever a subclause of IS 302-l
( 1979 ) is to be replaced by a new text it has been indicated as under:
‘Replacement’ - followed by the new text.
Any addition to the existing provisions of a subclause of IS 302-l ( 1979 ) has been indicated as
under:
‘Addition’ - followed by the text of the additional matter.
Clauses/tables which are additional to those of IS 302-l ( 1979 ) are numbered starting from 101
and additional subclauses are numbered with the main clause number followed by 101,102, etc,
for exemple 2.101.
Should however any deviations exist between IS 302-l ( 1979 ) and this standard, the provisions
of the latter shall apply.
While preparing this standard assistance has been derived from IEC Publication 335-2-25 ( 1988 )
‘Safety of household and similar electrical appliances : Part 2 Particular requirements for micro-
wave oven’ and IEC Publication 335-l ( 1976 ) ‘Safety of household and similar electrical
appliances’.
For the purpose of deciding whether a particular requirement of this standard is complied with,
the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded
off in accordance with IS 2 : 1960 ‘Rules for rounding off numerical values ( revised >‘. The
number of significant places retained in the rounded off value should be the same as that of the
specified value in this standard.
The Indian Standards which are necessary adjuncts to this standard are given in Annex BB.
AMENDMENT NO. 1 APRIL 2002
TO
IS 302-2-25 : 1994 SAFETY OF HOUSEHOLD AND
SIMILAR ELECTRICAL APPLIANCES
PART 2 PARTICULAR REQUIREMENTS
Section 25 Microwave Ovens
(Page 14, clause 101.1, lines 2 and 3) — Substitute 'a sample' for 'two
samples of the same type and rating'.
(Page 14, clause 101.1.1, line 1) - Substitute 'Sample' for 'Both samples'.
(ETD 32)
Reprography unit, BIS, New Delhi, India
IS 302-2-25 : 1994
Indian Standard
SAFETYOF HOUSEHOLD ANDSIMILAR
ELECTRICAL APPLIANCES
PART 2 PARTICULAR REQUIREMENTS
1 SCOPE 2 TERMINOLOGY
This clause of IS 302-l ( 1979 ) is applicable This clause of IS 302-l ( 1979) is applicable
except as follows: except as follows.
1.1 Replacemeat 2.6 Replacement
This standard covers the general and safety Rated frequency refers to input frequency.
requirements of appliances for heating food and
beverages using microwaves with or without 2.30 Replacement
additional forms of heating. The microwave Normal load denotes that the appliance is opera-
oven should be operating at a voltage not ted with a potable water load of initially
exceeding 253 V ac, single phase 50 Hz and ( 1 000 f 50 ) g in a cylindrical borosilicate
under *ISM bands of ( 91.5 or 50 ) MHz or glass vessel having a maximum material thick-
( 2 450 & 50 > MHz. ness of 3 mm and an outside diameter of
*ISM frequency bands are electroAmxgnetic freque- approximately 190 mm. The load is placed at
ncies established by International Treaty for the centre of the shelf. The initial temperature
Industrial, Scientific atld M:dical Purposes. of the water is 27 f 2°C.
1
IS 302-2-25 : 1994
2.107 Magnetron denotes a type of vaccum tube 4.3 This clause is applicable except as follows:
used to generate microwaves.
The test is carried out in the following order of
2.108 Stirrer denotes a device which changes the clauses and subclauses given below:
the microwave relationship between the load
in the cavity and the microwave generator by
32.1, 32.102 to 32.104, 7 to IO, 11 with 32.101,
mechanical, electrical or magnetic means. 13 to 17,20, 21.1 to 21.4, 18,19 except 19.106,
Examples of such devices are a rotating shelf, 22 to 31, 21.101 to 21.105and 19.106.
a moving secondary antenna or a metal
propeller. 4.101 Addition
Unless otherwise specified, microwave ovens are
2.109 Microwave transparency denotes the
tested as motor operated appliance.
property of a material having negligible absorp-
tion and reflection of microwaves. 4.102 Class IH temperature sensing probes are
The relative permittivity of a microwave not subjected to the tests, except that of 22.116.
transparent material is less than 7 and the loss
factor is less 0.015. 5 RATING
2.110 Interlock denotes a safety device or This clause of IS 302-I ( 1979 ) is applicable.
system, which prevents a particular situation
unless specified conditions exist.
6 CLASSIFICATION
An example of an interlock is a switch which
prevents the operation of the magnetron unless This clause of IS 302-l ( 1979 ) is applicable.
the cavity door is closed.
7 MARKlNG
2.111 Primary door safety interlock denotes an
interlo.ck provided with a supervision device This clause of IS 302-l ( 1979 ) is applicable
which in case of failure of the interlock except as follows.
prevents further operation of microwave oven
until the interlock is repaired or replaced. 7.1 Addition
2.112 Temperature sensing probe : Device which a) The word ‘Microwave .4ppliance’.
is inserted into the food to measure temperature
and which is the detachable component of a b) Rated microwave frequency in megahertz
control incorporated in a microwave oven. as per ISM band. This frequency shall be
the centre frequency of ISM band.
2.113 Steaming function : Process which supple-
ments microwave cooking by steam which is
generated at approximately atmospheric pres- c) Rated power output in watts.
sure.
d) Any cover giving access to the parts of,
3 GENERAL REQUIREMENTS at a voltage exceeding 250 V and if they
are likely to be removed by the user shail
3.1 Replacement be marked with the words ‘WARNING
This clause of IS 302-l ( 1979 1 is applicable HIGH VOLTAGE’.
except as follows:
If the access covers are likely to be remo-
In general, compliance is checked by carrying ved by the user in order to make simple
out the relevant tests as specified in 4.3 of this adjustments and if thereby live parts are
standard. rendered accessible. A permanent warning
notice shall be fixed to the appliance
4 GENERAL NOTES ON TESTS stating the substance of the following:
This clause of IS 302-l ( 1979 ) is applicable
except as follows. ‘Remove plug or disconnect from mains
before removing covers’.
4.2 Addition
An additional sample may be required for the If the removal of any covers allows micro-
test of 19.106. wave leakage exceeding the limit specified
as per 32.1 the following marking should
Six samples of the interlock are required for the be made on the cover warning in clearly
test of 18.101. legib!e lettering at least 3 mm high:
IS 302-2-25:1994
WARNING CA UT10N
MICROWAVE ENERGY MICROWAVE RADIATION
DO NOT REMOVE THIS COVER
DO NOT BECOME EXPOSED TO RADIA-
7.2 Replacement TION FROM MICROWAVE GENERATOR,
The rated input of heating elements providing a IF IT IS IMPROPERLY USED OR CONNEC-
browning function shall be marked either on TED. ALL ELECTRICAL CONNECTIONS,
each element or on rating plate. WAVEGUIDES, DOOR AND GASKETS
MUST BE SECURE, NEVER OPERATE THE
7.3 Not applicable. DEVICE WITHOUT, A MICROWAVE
ENERGY ABSORBING LOAD WITHtN IT.
7.5 Add the following in the list of symbols
MHz . . . . . . . . . . . . Mega hertz 8 PROTECTION AGAINST’ ELECTRIC
SHOCK
g . . . . . . . . . . . . Grams
7.8This clause of IS 302-I ( 1979 ) is not This clause of IS 302-l ( 1979 ) is applicable
applicable. except as follows.
7.12 Addition 8.2 Not applicable.
A microwave cooking appliance shall be provi- S 3 Not applicable
ded with a user instruction manual that warns ’
the user against reasonable, foreseable uses or 8.4 Not applicable.
misuses of the product thereby reducing the risk
of fire, electric shock, injury to persons and 9 STARTING OF MOTOR OPERATED
exposure to excessive microwave emission. These APPLIANCES
instructions shall include the methods for clea- This clause of IS 302-I ( 1979 ) is applicable.
ning door seals, cavity adjacent parts. A warning
shall be included stating that if these areas are 10 INPUT AND CURRENT
damaged the ovens must not be operated until
it has been repaired by a qualified service This clause of IS 302-I ( 1979 ) is applicable
person. The instruction sheet shall warn the except as follows.
user that it is hazardous for anyone other than Additional subcIause
a qualified service person trained by the manu-
facturer to service or repair the oven. 10.101 Heating elements providing browning
function shall comply with the tolerances speci_
The instruction sheet shall include the following tied for heating appliances.
matter ‘Before use, the user should check the
utensils are suitable for use in microwave ovens. 11 TEMPERATURE RISE
Furthermore, instruction sheets for microwave This clause of IS 302-l ( 1979 ) is applicable
ovens shall warn the user about possible hazards except as follows.
caused by delayed eruptive boiling of liquids.
11.2 Addition
The instruction sheet shall state the minimum
height of the free space necessary above the Microwave ovens are located for test as speci-
top surface of the oven. fied for heating appliances.
The instruction sheet for microwave ovens 11.4 Addition
provided with a socket for a temperature sensing
probe shall include the substance of the For microwave cooking appliances, the input
following: voltage shall be the same as for motor operated
appliances.
Only note the temperature sensing probe recom-
mended for this microwave oven. 11.7 Replacement
Additional Subclauses Microwave oven is operated according
7.101 Instruction for servicing shall clearly to 11.7.1.
identify all parts which are liable to be removed
when the appliance is serviced and which gives Microwave ovens incoporating components
access to potentials above 250 volts to earth or intended to be energized prior to heating the
which may cause undue microwave exposure. load ( stand-by condition ) are tested in this
mode until steady conditions are established,
Instruction for servicing shall clearly and legi- followed immediately by the test according
bly contain the following text: to 11.7.1.
3
IS 302-2-25: 1994
11.7.1 Microwave oirens are operated at full The microwave generator is switched on through-
power under normal load for consecutive out the test with its control set according to
periods. Each operating period is separated by the manufacturers instructions for roasting
a minute rest period with the door open, during meat. If instructions are not provided, the
which time the water load is replaced. microwave power setting is at 50 percent or at
the lowest microwave power setting above 50
The total time of operating period is 90 min. percent that can be selected.
The time of each operating period is determined
by the formula: If evaporation reduces the water load to
t = 9 000/P 500 g it is replenished with boiling water to
approximately 1 000 g. During the replenish-
where ment the door is opened for not longer than
t is the time in minutes, and 10 s.
P is the microwave power output in watts 11.7.6 Microwave oven incorporating automatic
rounded off to the nearest hundred watt. programmes are operated with a water load
as specified in 2.30 and with the most
The microwave power output is determined unfavourable programme that can be selected in
according to Annex AA. accordance with the manufacturers’ instruction.
If necessary the programme is repeated so that
11.7.2 Microwave ovens incorporating a brow- the load test time for appliances with micro-
ning function that can only be energized sequen- wave heating only is not less than 90 minutes
tially to microwave power are further operated and for appliances incorporating conventional
immediately after the test specified in 11.7.1 heating means the total time is not less than
after removal of water load. The browning 60 minutes.
function with its control set at maximum for
a period of 10 minutes or for a longer time, if If evaporation reduces the water load to
specified by the manufacturer. 500 g it is replenished with boiling water to
4
IS 302-2-25 : 1994
approximately 1 000 g. During the replenish- A quantity equal to 500 g of water containing
ment the door is opened for not longer than 10 approximately 1 percent NaCl is poured steadily
seconds. over the shelf over a period of 1 minute.
11.7.7 Microwave ovens incorporating a stea- However, the appliance is provided with a shelf
ming function that can only be operated sequen- or other receptacle intended for collecting spi-
tially to microwave power are initially operated lled liquid, the receptacle is filled with the
under the conditions specified in 11.7.1 but for saline solution and further quantity equal to
a period of 30 min. The water load is then 500 ml is then added over a period of 1 minute.
removed and the steaming function operated Immediately after this treatment, the appliance
for the maximum period allowed by any timer shall withstand an electric strength test as
controlling the steaming function or until the specified in 16.4 and inspection shall show
appliance switches off automatically. that water which may have entered the
11.7.8 Microwave ovens incorporating a stea- appliance does not impair compliance with
ming function that can be operated simultaneo- this standard; in particular, there shall be no
usly with microwave power are operated under trace of water on insulation which could result
normal load with the steaming function switched in a reduction of creepage distances and
on. clearances below the values specified in 29.1.
The microwave oven is operated for the maxi- The appliance is allowed to stand in normal
mum period allowed by anv timer for simul- test-room atmosphere for 24 h before being
taneous operation or until the appliance is subjected to the test of 15.4.
switched of’i automatically.
The microwave generator is switched on with Appliances provided with a steaming function
its power control set according to the manufac- are also subjected to the following test:
turer’s instructions. If instructions are not The water container is completely filled with
provided, the microwave power setting is at water containing approximately 1 percent NaCl
50 percent or the lowest microwave power and a further quantity equal to 15 percent of
setting above 50 percent that can be selected. the capacity of the container or 0.5 1, whichever
12 OPERATION UNDER OVERLOAD CON- is greater, is poured in steadily over a period of
DITIONS OF APPLIANCES WITH HEATING 1 min.
ELEMENTS Additional Subclause
This clause of IS 302-l ( 1979 ) is not appli- 15.101 Temperature sensing probes shall be
cable. constructed so that the insulation is not affec-
13 ELECTRICAL INSULATION AND ted by water.
LEAKAGE CURRENT AT OPERATING
TEMPERATURE Compliance is checked by the following test
which is performed outside the microwave
This clause of TS 302-l ( 1979 ) is applicable.
oven:
14 RADIO AND TELEVISION INTERFE-
RENCE SUPPRESSION The probe is compIetely immersed in water
containing approximately 1 percent NaCl and
This clause of IS 302-l ( 1979 ) is applicable. having a temperature of 27°C f 5°C. The water
15 MOISTURE RESISTANCE is heated to the boiling point in approximately
15 min. The probe is then removed from the
This clause of IS 302-l ( 1979 ) is applicable boiling water and immediately immersed in
except as follows. water having a temperature of 27°C f 5°C for
15.3 Replacement 30 min.
Appliances shall be so constructed that spillage This procedure is carried out five times, after
of liquid does not affect the electrical insulation. which the probe is removed from the water.
Compliance is checked by the following test: All traces of liquid are removed from the sur-
face by wiping with a soft cloth.
Appliances provided with an appliance inlet are
fitted with an appropriate connector and flexible The probe shall then withstand the test of 16.2.
cable for cord, appliances with type-X attach- 16 INSIJLATION RESISTANCE AND ELEC-
ment are fitted with the lightest permissible type TRIC STRENGTH ( After Humidity Treatment )
flexible cable or cord of the smallest cross-
sectional area specified in 26.2 and other This clause of IS 302-l ( 1979 ) is applicable
appliances are tested as delivered. except as follows.
5
1$302-2-25 : 1994
Heating elements are tested as specified for This clause of IS : 302-l ( 1979 ) is applicable
heating appliances. Appliances are additionally except as follows.
checked by the test of sub-clause. 17.1 Addition
Additional Subclause The tests are not applied to the main power
16.101 A voltage is applied for 1 min between: transformer and its associated circuits which
a) The primary and secondary windings of are checked during the test of 19 of IS 302-l
power transformers; ( 1979).
b) The secondary circuit and the body after 18 ENDIJRANCE
any component connected to earth has This clause of IS 302-I ( 1979 ) is applicable,
been disconnected. except as follows.
The voltage is ac except for dc circuits for
18.1 Replacement
which dc voltage is applied.
Instead of the test specification, the following
The value of voltage is twice the maximum
shall apply:
working voltage plus 750 V but with a minimum
of 1 250 V. Compliance is checked by the test of 18.101. In
The maximum working voltage for a composite addition, for motors, compliance is checked by
( dc plus ac ) voltage is equal to 0.707 multiplied the tests of 18.2, 18.5 and 18.6.
by the composite peak value. 18.101 Addition
During the test there shall be no flashover or It may be necessary to make special connec-
breakdown that will give rise to a fire or shock tions so that only the motors are operated.
hazard.
Additional Subclauses
The magnetron is not connected during the test.
A meter having a maximum impedance of 18.1OI InterIocks other than those subjected to
30 MQ is used for measuring secondarycircuit the test of 18.102 are subj-cted to the follow-
voltage. ing tests which ace mlde on 6 samples at the
16.102 Power transformer shall have adequate rate not exceeding 6 cycles per min.
internal insulation. Interlocks likely to be operated during normal
Compliance is checked by the following test: use are subjected to 50 000 cycles of operation.
A sinusoidal voltage is applied to the primary Interlocks likely to be operated during user
terminals of the power transformer such that maintenance are subjected to 5 000 cycles of
twice the working voltage is induced in the operation.
secondary winding. The tests are carried out with the interlock
The frequency of the applied voltage is increa- controlling its normal electric load.
sed above rated frequency so as to avoid exces-
sive excitation current, the duration of the test After the tests, interlocks shall show no damage
being, impairing their future use.
a) 60 s for frequencies up to twice the rated 18.102 The door system of microwave ovens,
frequency; including hinges, microwave seals and other
b) 120 times the rated frequency divided associated parts, shall be constructed as to
by the test frequency with a minimum withstand wear that may be expected in normal
of 15 s for frequencies above twice the use.
rated frequency. Compliance is checked by subjecting the door
In each case, a maximum of one-third of the test system to a total of I 00 000 cycles of operation.
voltage is initially applied after which it is The doer system is subjected to 10 000 cycles
increased rapidly. while the appliance is supplied at the rated input
At the end of the test, the voltage is reduced and containing an appropriate microwave absor-
rapidly to less than one-third of the test voltage bing load, and to 10000 cycles of operation
before switching off. with the power switched off.
During the test, there shall be no flash over or The device for opening the door is attached to
breakdown between windings or between adja- the door handle or applied to the normal opera-
cent turns of the same winding. ting area.
6
IS 302-2-25 : 1994
7
IS 302-2-25:1994
9
IS 302-2-25 : 1994
The dowel is then positioned so that it is placed It shall not be possible to operate the interlock
centrally within the door hinge and the test during the test.
carried out yet again. 22.104 The primary safety interlock shall be so
designed that undue microwave leakage is
After these tests, microwave leakage is measured prevented.
under the conditions of 32.1 and shall not
exceed 10 mW/cmg. Compliance is checked by the following test.
10
1s 302-2-25 : 1994
All door interlocks except the primary door The door seals are coated with cooking oil. If
safety interlock are made inoperative and the the door seal is of open choke type, the trough
test of 32.103 is carried out. is filled with cooking oil.
22.105 Failure of primary door safety interlock Oven is then subjected to the test of 32.1.
shall cause the oven to become inoperable.
22.110 Microwave oven shall not give rise to
Compliance is checked by the following test:
undue microwave leakage if thin material is
The interlock is made inoperative and the oven introduced between the door and its mating
is operated with the door closed. An attempt is surface.
then made to gain access to the cavity in the
normal way. Either it shall not be possible to Compliance is checked by closing the door on
open the door or the microwave generator shall a strip of paper having a width of ( 60 f 5 )
shut down and become inoperable. mm and a thickness of ( 0.15 & 0.05 ) mm. The
paper is placed in ten different positions in the
If an internal fuse in the circuit supplying the seal between the door and its mating surface
microwave ruptures, the following test is carried and the test of 32.1 is carried out each time.
out:
22.111 If the ovens for building-in are vented,
The fuse is replaced and the oven is connected they shall be vented through the front unless
to a supply source having a prospective short- provision is made for venting through the duct.
circuit capacity of 1.5 kA. The interlock is
made inoperative and the access to the cavity is Compliance is checked by inspection.
gained as before. The test is carried out three 22.112 Interlocks operated by detachable parts
times. The internal fuse shall rupture each time. shall be guarded so that accidental tripping is
This test is carried out three more times, except prevented.
that an impedance of ( 0.4 + jO.25 ) ohm is
inserted in series between the supply source and Compliance is checked by inspection and by the
the oven. The internal fuse shall rupture each manual test.
time.
22.113 The interlock and the door system shall
During these tests, the shorting switch shall be designed to prevent undue microwave leakage
not fail in the open position. when the door corners are subjected to mechani-
cal distortion.
22.106 The failure of any single electrical and
mechanical component which affects the opera- Compliance is checked by the following test:
tion of a door interlock shall not cause any
other door interlock to become inoperative. Doors are cIosed and a pulling force is applied
perpendicular to the surface of the door to
Compliance is checked by inspection and by the each corner in turn to expect that for hinged
tests of component faults. doors the corners close to the hinge are not
tested. If the door is latching, the maximum
22.107 The interlock system shall not allow operation of the manual opening device permit-
operation of the microwave generator with the ting microwave generation is also applied.
door open due to single fault such as failure of
basic insulation to earth. The force is slowly increased until the micro-
wave generation is turned off or to a maximum
Compliance is checked by inspection of the of 40 N. During the test the microwave leakage
circuit diagram, of the oven and by tests of is measured under the conditions of 32.1 and
relevant faults. shall not exceed 10 mW/cme.
22.108 Oven vent shall be designed that any Immediately after removing the force, the
moisture or grease discharged through them microwave leakage is measured again and shall
cannot affect the creepage distances and the not exceed 5 mW/cme.
clearances between bare live parts and other
parts of the appliance. 22.114 It shall not be possible to remove the
cavity door of a microwave oven without the
Compliance is checked by inspection. aid of the tool unless the microwave generator
22.109 Microwave oven shall not give rise to cannot operate without the door being properly
undue microwave leakage in the event of re-installed.
cooking oil contaminating the door seals.
Compliance is checked by inspection and by
Compliance is checked as follows. manual test.
11
IS 302-2-25 : 1994
22.115 Microwave ovens with temperature sen- earthing contact and having a rated current not
sing probes shall be constructed so that the exceeding 16 A. Both poles of such socket out-
probe is not damaged and that undue microwave lets shall be protected by means of fuses or
leakage does not occur if the probe or its cord miniature circuit-breakers incorporated in
is trapped by the oven door. the oven and placed behind a non-detachable
cover, except that, for ovens having a rated
Compliance is checked by the following test: current not exceeding 16 A, the poles of the
The load specified in 32.1 is placed in the oven socket-outlet need not be protected, and that,
and the probe connected as in normal use, the for ovens intended to be permanently connec-
sensing part or cord being allowed to rest in ted to a fixed wiring only, the pole intended to
the most unfavourable position likely to occur. be connected to the neutral conductor shall not
The door is then closed against the sensing part be protected.
or cord with a force of 90 N for 5 s. The force Compliance is checked by inspection.
is applied to the door in the most unfavourable
place. The force is then released and if the oven 24.102 The microwave ovens shall incorporate
can be operated the microwave leakage is a time control device.
measured in accordance with 32.1 and shall not
exceed 100 W/m*. 25 SUPPLY CONNECTIONS AND EXTER-
NAL FLEXIBLE CABLES AND CORDS
After the test the probe shall comply with 8.1,
15.101 and 29.1 and the microwave oven shall 25.6 Addition
comply with 32.1. The length of the power supply cord external
22.116 ‘Appliances incorporating a steaming to the appliance shall be not less than 2.05 m
function shall be constructed so that the steam when supplied without a plug and not less than
generator is switched off when the cavity door 2.0 m when supplied with a plug.
is opened.
This clause of IS 302-I ( 1979 ) is applicable
Compliance is checked by inspection. except as follows.
22.117 Appliances incorporating a steaming 25.19 Addition
function shall be constructed so that the
discharge of water from the water container For temperature sensing probes the total number
does not affect the electrical insulation. of flexings is 5 000. Probes with circular section
cords are turned 90” after 2 500 flexings.
Compliance is checked by inspection and by
manual test. 26 TERMINALS FOR EXTERNAL
CONDUCTORS
23 INTERNAL WIRING
This clause of IS 302-l ( 1979 ) is applicable.
This clause of IS 302-l ( 1979 ) is applicable.
24 COMPONENTS 27 PROVISION FOR EARTHING
This clause of IS 302-I ( 1979 ) is applicable This clause of IS 302-l ( 1979 ) is applicable.
except as follows.
28 SCREWS AND CONNECTIONS
Addition
This clause of IS 302-l ( 1979 ) is applicable.
24.2 However, a shorting switch intended to
cause the rupture of an internal fuse in the 29 CREEPAGE DISTANCES AND
circuit supplying the microwave generator can CLEARANCES
be fitted if it is necessary to use a tool for the
replacement. Furthermore, the fuse rating shall This clause of IS 302-l ( 1979 ) is applicable
not exceed the lowest value of the fuse in the except as follows.
supply line in which the appliance can be
operated. 29.1 Addition
12
IS 302-2-25 : 1994
metal parts not less than those stated in the following table.
Voltage ( Peak Value ) Clearance Creepage
V mm Distance
mm
For circuits with voltages greater than 4 000 V Compliance is checked by measuring the energy
peak value, creepage distances and clearances flux density of microwave leakage at any point
between the live parts of different polarity and 5 cm or more from the external surface of the
between live parts and accessible metal parts appliance. It shall not exceed 5 mW/cm2.
are additianally checked by applying a voltage, The energy flux density of microwave leakage is
for 1 min, determined by the following formula: determmed by measuring the microwave power
v = 2 u + 750 density by means of an instrumeut which rea-
ches 90 percent of its steady-state reading in
where V is rhe test voltage and U is working 2 s to 3 s when subjected to a stepped input
voltage. signal.
There shall be no flashover or breakdown. Unless otherwise specified, the measurements
are made with the microwave oven supplied at
The creepage distances and the clearances speci- rated voltage and with the microwave power
fied do not apply across a spark gap or similar control set at the maximum. A load of ( 275 f
device which is necessary for the correct 15 ) g of potable water having an initial tem-
functioning of the oven. perature of ( 27 f 2 )“C contained in a micro-
wave transparent thin-wall vessel having an
30 RESISTANCE TO HEAT FIRE AND inside diameter of approximately 85 mm, is
TRACKING placed at the centre of the shelf. The instrument
antenna is moved over the external surface of
This clause of IS 302-l ( 1979 ) is applicable.
the oven to locate the points of maximum
31 RESISTANCE TO RUSTING
leakage, particular attention being given to the
door and its seals.
This clause of IS 302-I ( 1979 ) is applicable.
If the temperature of the load affects the results,
the measurement is repeated with a fresh load.
32 RADIATION HAZARDS
Additional Clauses
This clause of IS 302-l ( 1979 ) is applicable
except as follows. 32.101 Temperature resulting from the operation
of conventional heating means shall not give
32.1 Addition rise to undue microwave leakage.
Microwave ovens shall be so designed that Compliance is checked by test of 32.1 immedi-
excessive microwave leakage is prevented. ately after the relevant test of 11.
13
IS 302-2-25 : 1994
32.102 The removable or detachable parts shall NOTE - Additional samples may be required for
not give rise to undue microwave leakage. the test of 19.106 ( see also 4.2 ).
The oven is then subjected to the test of 32.1, Table 101 Schedule of Type Tests
the vessel being placed on the horizontal sur- ( Clause 101.1 )
face as close as possible to the centre of the
cavity. SI No. Tests Clause
Refer&&e
32.103 Microwave ovens shall be constructed i) Protection against electric shock
such that any position of the cavity door does ii) Starting of motor operated appliances
iii) Input
not give rise to undue microwave leakage. iv) Temperature-rise
Y) O;Jeration under overload conditions
Compliance is checked as follows: “1) Electrical insulation and leakag-
current at operating temperature
The door is held in any position that can be vii) Radio and television interference
suppression
obtained during the door opening sequence. viii) Moisture resistance
This sequence is performed using small incre- ix) Insulation resistal-ce and electric
ments. strength ( after humidity treatment )
x) Overload protection
During the test the oven shall comply with 32.1. xi) Endurance ( Under consideration )
xii) Abnormal operation
xiii) Stability and mechanical hazards
32.104 Appliances shall be constructed such that xiv) Mechanical strength
there is no access to the cavity through the xv) Construction
viewing screen. xvi) Tr,terDal wiring
xvii) Components
Compliance is checked by inspection and by xviii) Cord grip and cord guard
xix) Terminals for exter::al conductors
the following test: Provision for earthing
xx)
xxi) Screws and connections
A straight steel rod having a diameter of 1 mm xxii) Creepage distances and clearances
xxiii) Resistance to heat, time and tracking
and a blunt end is pressed perpendicularly xxiv) Resistance to rusting
against the viewing screen with a force of 2 N. XXV) Radiation hazards
The rod shall not enter the cavity.
101 TESTS 101.2 Acceptance Tests
101.1 Type Tests The fo!lowing shall constitute the acceptance
tests:
The tests specified in Table 101 shall constitute
the type tests and shall be carried out on two Tests Clause
samples of the same type and rating selected Reference
preferably at random from a regular production a) Protection against. electric shock
lot. Before commencement of the tests, the b) Input 1:
samples shall be visually examined and inspected C) Temperature-rise 11
for obvious visual defects in respect of com- d) Electrical insulation and leakage 13
ponents, parts and their assembly, construction, current at operating temperature
mechanical hazards, marking, provision, of e) MGture resistance 15
suitable terminals for supply connections, f) Insulation resistance and electric 16
earthing and the effectiveness of screws and strength ( after humidity treat-
connections. The external surface finish shall ment )
be even and free from finishing defects. g) Provision for earthing 27
14
'IS302-Z-25
:1994
15
IS 302-2-25: 1994
ANNEX A
TABLES OF TYPE TESTS
This Annex A of IS 302-l ( 1979 ) is replaced as follows:
The tests are conducted in the order of the clauses as given under 4.3 of this standard.
ANNEX B
SAMPLING PROCEDURE FOR ACCEPTANCE TESTS
This Annex B of IS 302-I ( 1979 ) is applicable.
ANNEX C
ELECTRONIC CIRCUITS
This Annex C of IS 302-l ( 1979 ) is applicable except as follows:
Magnetron and its power supply circuit is not applicable under this test.
ANNEX D
MEASUREMENT OF TEMPERATURE WITH THERMOMETER
This Annex D of IS 302-l ( 1979 ) is applicable.
ANNEX E
ALTERNATIVE TESTS FOR PROTECTED MOTOR UNITS
This Annex E of IS 302-I ( 1979 ) is applicable.
ANNEX F
IMPACT TEST APPARATUS
This Annex F of IS 302-l ( 1979 ) is applicable.
ANNEX G
THERMAL CONTROLS AND OVERLOAD RELEASES
This Annex G of IS 302-l ( 1979 j is applicable.
ANNEX H
MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES
This Annex H of IS 302-l ( 1979 ) is applicable.
ANNEX J
TEST FOR FIRE-RESISTING PROPERTIES
This Annex J of IS 302-l ( 1979 ) is applicable.
ANNEX K
BNF JET TEST FOR DETERMINATION OF THICKNESS OF COPPER AND
NICKEL PLATING
This Annex K of IS 302-l ( 1979 ) is not applicable.
16
IS 302-2-25:1994
ANNEX L
APPROXIMATE MEASUREMENT OF THICKNESS OF CHROMIUM
ON NICKEL, STEEL AND COPPER
This Annex L of IS 302-l ( 1979 ) is not applicable.
ANNEX AA
( Clause 11.7.1 )
DETERMINATION OF MEASUREMENT OF MICROWAVE POWER OUTPUT
Microwave power output measurement is made The microwave power output P in watts is
with the microwave oven supplied at its rated calculated from the following formula:
voltage and operated at its maximum microwave
power setting with a load of ( 1 000 f 5 ) g of P = 4 187 ( kT)/t
potable water. t is measured while the microwave generator is
The water is contained in a cylindrical borosi- operating at full power. Magnetron filament
licate glass vessel having a maximum thickness heat-up time is not included.
of 3 mm and an outside diameter of approxi-
mately 190 mm. The water is stirred to equalize temperature
throughout the vessel, prior to measuring the
The oven and the empty vessel are at ambient final water temperature.
temperature prior to the start of the test.
The initial temperature of the water is ( 27 f Stirring devices and measuring instruments are
2 )“C. It is measured immediately before the selected in order to minimize addition or
water is added to the vessel. After addition of removal of heat.
the water to the vessel, the load is immediately
placed on the centre of the shelf which is in the Operating time is measured while the microwave
lowest position and the microwave power swit- generator is operating at full power. Magnetron
ched on. heat-up time is not included.
The time i for the temperature of the water to The water is stirred to equalize temperature
rise by a value kT of (27 f 2 ) “C is measured, throughout the vessel, prior to measuring the
where t is the time in seconds and kT is the final temperature.
temperature rise. The initial and final water
temperatures are selected so that the maximum Stirring devices and measuring instruments are
difference between the final water temperature selected such that no addition or removal of
and the ambient temperature is 5°C. heat is possible while making the measurement.
ANNEX BB
( Foreword )
IS No. Title IS No. Title
302-l ( 1979 ) Safety of household and 4159 : 1983 Mineral filled sheathed heating
similar electrical appliances : elements (first revision )
Part 1 General requirements
( fifth revision )
17
Borean of Indian Standards
BIS is a statutory institution established under the Bureau of Zndian Standards Act, 1986 to
promote harmonious development of the activities of stadardization, marking and quality
certification of goods and attending to connected matters in the country.
Copyright
BIS has the copyright of all its publications. No part of these publications may be reproduced
in any form without the prior permission in writing of BIS. This does not preclude the free USC,
in the course of implementing the standard, of necessary details, such as symbols and sixes, type
or grade designations. Enquiries relating to copyright be addressed to the Director
( Publications ), BIS.
This Indian Standard has been developed from Dot : No. ETD 32 ( 3714 ).