Professional Documents
Culture Documents
Product: WK Series Industrial Burners
Product: WK Series Industrial Burners
2
60 Years of reliability
For more than six decades, Weishaupt WK-series burners have Experienced employees and the high
Weishaupt burners have proven been designed especially for industrial proportion of in-house production allow
themselves on a wide variety of use. The modular design of the burners Weishaupt to meet its own demands
heat generators and process plant. and their very large capacity range – for the highest levels of quality.
Their success results from 1,000 to 109,000 MBH – means they
Weishaupt’s relentless demand for are ideally suited to a broad spectrum High quality is reflected by Weishaupt’s
high-quality materials and work- of special applications. ISO 9001-2015 certification, which
manship, and from uncompromi- covers the development, production,
sing quality control standards. All Weishaupt burners are manufactu- sales and servicing of burners and con-
red at the company’s main plant in trol panels.
Weishaupt continually establishes new Schwendi in southwestern Germany.
benchmarks with its well-engineered Not only does this extremely modern Weishaupt offers individualized soluti-
products, facilitated by the ever-con- production facility serve as a beacon of ons for the supply of fuel and the con-
stant efforts of its own in-house safety, precision and cleanliness, it also trol of burners and boilers. Of course,
Research and Development Centre. allows for a rapid response when its product range also covers an array
assembling small, medium and large- of modern instrumentation and control
size burners. equipment, including fully comprehensi-
ve solutions for complex building auto-
mation projects.
Cover
Burner housing
WK burners can adapt to various installations – even under the toughest conditions
Modular design principle Insulated burner housing Heat recovery through the use of
Weishaupt WK industrial burners are Internal thermal insulation reduces the preheated combustion air
designed according to the modular prin- surface temperature on the housing In industrial processes, high medium
ciple, which means that the fan, pump and also ensures noise reduction. temperatures result in very high exhaust
station and preheating station are arran- (WK 40/50 optional with cold air) gas temperatures. A large amount of
ged separately from the burner. This con- energy can be recovered from these hot
cept offers great flexibility for adapting to exhaust gases via a heat exchanger in
a wide variety of applications and moun- the stack. With possible combustion air
ting situations. temperatures of up to 480F (250°C), the
combustion efficiency can be improve by
up to 10%.
4
Acessibility Nozzle head and sliding sleeve Dedicated ignition position
The control compartments of the WK WK80 burners are equipped with nozz- The W-FM combustion managers offer
burners are generously dimensioned. le head and sliding sleeve which modu- parameters for dedicated ignition posi-
Structure and cable routing are clear late according to the firing rate. They tion. This makes it possible to achieve
and allow the best accessibility for are driven by a dedicated actuator. safe ignition behavior even under the
maintenance work. A cover hood that Flame stability and mixing energy most varied of conditions.
can be rotated by 90° ensures optimal remain optimal over the entire control
ventilation and cooling of the compo- range. Controlled shutdown from low fire
nents during heavy oil operation. The controlled shutdown of the burners
Nozzle head shut-off device only takes place at low fire position.
Serviceability At burner shutdown or when changing This avoids pressure surges in the gas
For easier handling of the mixing head over from oil to gas operation, safety line and in the combustion chamber.
assembly, a rail system with a service shutoff devices in the nozzle head shut
position has been developed in larger off the oil flow directly in the nozzle
burner unit, which significantly simpli- orifice, preventing the escape of any oil.
fies removal and installation.
Actuator
for nozzle lance and sliding sleeve
Nozzle lance (cooled)
5
Digital combustion management:
Precise, simple, and reliable
Flexible communication options capacity range. This reduces flue gas
The integrated interface enables all losses and saves fuel.
necessary data and functions to be
relayed to a master control system via, Variable frequency drive reduces electri-
for example Modbus RTU, Modbus cal consumption and facilitates a soft
TCP/IP, BacNet, etc (gateway or proto- start of the combustion air fan. The use
col converter might be required). of VFD also reduces noise emissions by
a considerable amount.
Measures for saving energy and increa-
sing safety and reliability O2 trim saves fuel through a continual
and extremely efficient optimization of
Electronic fuel air ratio control with the the combustion air. Different O2 probes
W-FM 100 and 200 combustion mana- are available, providing suitable solutions
gers facilitates the extremely precise, for almost all fuels in applications with
hysteresis-free setting of the burner. flue-gas temperatures below 570F
The burner can be adjusted for ideal (300°C)..
combustion figures throughout its entire
Setting via the ABE control and display unit
l Optional l Standard
6
O2 probe
Temperature sensor
Blower
M fan
motor
Status 1 (1)
17.92 mA 10,4 A 5,6 kW
Speed 43,5 Hz
87.0 %
sensor Auto Fern Betrieb
Status Quick
Menu
Main
Menu
Alarm
Log O2-Module
Ca
ck
nc
Ba
el
Info
On OK
Pulse input for oil and gas meters
Warn.
Alarm
Up to 6 actuators for:
– Gas supply Display and
– Air supply
Variable frequency
operating unit
– Oil supply So l l we r t
I s t we r t
80 . 0 °C
78 . 5 °C
Le i s t ung 64 . 8 %
– Sliding sleeve (air) F l a mm e 98 . 5 %
info esc
– FGR damper
drive
IEC 127-2/V
L
PE
N
L
L
L
(CPI)
min.
max.
L
PE
N
L
L
L
L
ION
FSV/QRI
PE
N
L
Power QRI
QRB
L
N
G0
G
LT
LINE
12VAC
1
1
OIL
GAS
V1
PV
SV
V2
V1
V1
FLAME 5
PE 4
/ -
X7-01
V2
OIL
-20°C to + 60°C
V3 0
- 4°F to +140°F
PE FCC: part 15, Class B
X7-03
GAS
Start
-
X6-01
IEC 127-2/V
1P
F1/T6,3
PE
/ -
X6-03
S 1312120025
SV
ACS 450
OIL
(START)
FLANGE
SAFETY
RESET
IGNITION
VOLTAGE
MOTOR
ALARM
LOOP
L
1
1
LINE
ON/OFF
software
3
2
GAS
max
min
OIL
INT
PE
PE
PE
PE
PE
N
N
L
L
L
L
L
X5-01 X5-02 X5-03 X4-01 X4-02 X4-03 X3-01 X3-02 X3-03 X3-04
Combustion manager
W-FM 200
mbar
2,5
50
5 P
A2
50A2P r
45
10
W mba
50 r r.
.LG LGW ÷ mba
Ausf Typ 2,5 g.N
15
40
400
–Re
eich x =
Ber pma GWe 128
–DV 9 35
20
DIN 80.0
30 25
Temp/ pres- Air pressure Gas pressure Oil pressure Gas SSOV Oil valve
sure sensor switch switch switch
7
Powerful Industrial burners
with modular design
Combustion-air
Parallel operation Air preheater fan
Air
deflector Burner
8
Gas valve train and accessories
Oil-supply accessories
A one-stop solution for reliability (illustration shows burners with some European components)
9
The right mixing assembly for every application
Mixing head version Flame geometry Burner model Sliding sleeve Fuel
#6 heavy oil
Service friendly design: The flame tube and mixing head in stan- Length Diameter
Natural gas
#2 light oil
dard length can be removed from the burner side. On larger burner
Propane
such as WK80, the mixing head can be moved backwards on a
integrated railing.
WK 40 ● ● ● ●
ZM(H) WK 50/1 ● ● ● ●
Mixing head for oil, gas and WK 50/2 ● ● ● ●
dual fuel burners. For applica-
tion without specific NOx
WK 70/1 – – ● ●
requirements. WK 70/3 – – ● ●
WK 80/3 – – ● ●
ZM(H) - NR
Mixing head for gas and dual WK 50/1 ● ● ● ●
fuel burners. NOx reduction on WK 50/2 ● ● ● ●
gas side compared to ZM ver-
WK 70/1 ● ● ● ●
sion.
WK 70/3 ● ● ● ●
WK 80/3 ● ● ● ●
ZM(H) - LN
LowNOx Mixing head for gas
burners. WK 40 – ● – – –
WK 70 – ● – – –
In comparison to 1LN version
further reduction of NOx emis-
sions..
ZM(H) - 1LN
LowNOx Mixing head for gas
and dual fuel burners. WK 50/1 – ● ● ● –
WK 50/2 – ● ● ● –
For applications with slight WK 70 – ● ● ● –
NOx requirements on oil and
gas operations.
ZM(H) - 3LN
WK 40 ● ● ● –
LowNOx Mixing head for oil,
gas and dual fuel burners. WK 50/1 ● ● ● –
WK 50/2 ● ● ● –
For applications with lowNOx WK 70 ● ● ● –
requirements on oil and gas WK 80/1 ● ● ● –
operations. ● ●
WK 80/2 ● –
1)
Minimum requirements of combustion chamber need to be consulted with Weishaupt
10
Mixing head version Flame geometry Burner model Sliding sleeve Fuel
#6 heavy oil
Length Diameter
Natural gas
#2 light oil
Propane
ZM(H) - 4LN
LowNOx mixing head for gas WK 70/1 ● – – –
burner with FGR. WK 70/2 ● – – –
WK 80/1 ● – – –
Lowest NOx-Emission in
WK 80/2 ● – – –
cpmparison to all other versi-
ons.
ZM(H) - 1SF
Swirl mixing head for oil, gas
and dual fuel burners. WK 50/2 ● – ● ●
WK 70/1 ● – ● ●
Swirl mixing head for extreme- WK 80/3 ● – ● ●
ly short combustion chamber,
typcally on watertube boiler.
ZM(H) - VSF
Swirl mixing head for gas bur-
ners.
11
Overview of capacities
Oil burners
Version Standard
WKL and WKMS #2 light and #6 heavy oil burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
Version 3LN
WKL #2 light oil burners (based on WKGL)
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
WK 40/2-A ZMH-3LN #2 oil 1,230 – 7,100 / 7,500 Min. high fire 3,100 / 3,100
12
12
Version 1SF
WKL and WKMS #2 light and #6 heavy oil burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
WK 50/2-A ZM(H)-1SF #2 oil 3,840– 16,380 / 20,480 Min. high fire 13,650/ 11,000
#6 oil 5,800– 16,380 / 20,480
The burner capacity with combustion air temperature between 104F/40°C and
212F/100°C and between 104F/40°C and 480F/250°C can be interpolated.
13
Overview of capacities
Gas burners
Version Standard
WKG natural gas and propane burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
Version NR
WKG natural gas and propane burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
14
14
Version LN
WKG natural gas burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
Version 1LN
WKG natural gas and propane burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
The burner capacity with combustion air temperature between 104F/40°C and
212F/100°C and between 104F/40°C and 480F/250°C can be interpolated.
Version ZM: Combustion air temperatures up to 40 °C See the planning and installation handbook for fan selection and arrangement,
Version ZMH: Combustion air temperatures up to 250 °C gas valve trains, special equipment, technical data, and dimensions.
15
Overview of capacities
Gas burners
Version 3LN multiflam®
WKG natural gas and propane burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
16
16
Version 1SF
WKG natural gas burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
WK 50/2-A ZM(H)-1SF Nat. gas 2,730 –16,380/ 20,475 Min. high fire 13,700 / 11,000
Version 3SF
WKG natural gas burner
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
Version VSF
WKG natural gas and propane burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
The burner capacity with combustion air temperature between 104F/40°C and
212F/100°C and between 104F/40°C and 480F/250°C can be interpolated.
Version ZM: Combustion air temperatures up to 40 °C See the planning and installation handbook for fan selection and arrangement,
Version ZMH: Combustion air temperatures up to 250 °C gas valve trains, special equipment, technical data, and dimensions.
17
Overview of capacities
Dual-fuel burners
Version Standard
WKGL and WKGMS dual-fuel burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
18
18
Version NR
WKGL and WKGMS dual-fuel burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
The burner capacity with combustion air temperature between 104F/40°C and
212F/100°C and between 104F/40°C and 480F/250°C can be interpolated.
19
Overview of capacities
Dual-fuel burners
Version 1LN
WKGL dual-fuel burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
20
Version 1SF
WKGL and WKGMS dual-fuel burners
Burner Version Fuel Rating MBH
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000
ZMH / ZM
The burner capacity with combustion air temperature between 104F/40°C and
212F/100°C and between 104F/40°C and 480F/250°C can be interpolated.
21
Fuel systems
Oil/ Gas burners
Oil burners
WKL40 - 80 WKMS40/50
3 6 8 3 4 10 6 8
P P
2
60V
60V
110V
60V 60V
P M P M
M M
9 7 12 11 9 5 7 12 11
1a 14 1a 14
WKMS 70/80
3 4 10 6 8 1 Oil pump
1a External pump station with pressure regulator
2 Oil preheater
P 3 Strainer
2 4 Temperature sensor in supply
5 Temperature sensor in return
60V
6 Low-pressure switch
110V 7 High-pressure switch
60V 8 Solenoid valve in supply (installed in the direction of flow)
P M 9 Solenoid valve in return (installed against the direction of flow)
10 Bypass solenoid valve (normally open)
11 Solenoid valve assembly
11a Nozzle head with secondary nozzles
M 11b Nozzle head with primary nozzle
9 7 12 5 11 12 Oil regulator
13 Pressure regulating valve
14 Filter
1a 14
22
Oil burners
P P
M M
9 9 7 12 11a 9 9 7 12 11a
1a 14 1a 14
Gas burners
1 Ball valve
1b 2b 4b 1a Ball valve
1b Ball valve on pilot gas train
2 Gas pressure regulator
7 2b Pilot gas pressure regulator
3 Low gas pressure switch
4 2 main gas SSOVs and 1 N/O vent valve
4b 2 pilot gas SSOVs and 1 N/O vent valve
5 High gas pressure switch
P 5a High gas pressure switch
6 Gas butterfly valve
7 Burner
P P
1 2 3 4 5 1a 6 5a
* The above shows typical gas train configuration only. The actual gas train configuration
shipped with burner might differ depending on applicable codes/ regulation and application.
23
Flame monitoring
for the most demanding safety requirements
Flame monitoring plays a crucial
role when it comes to safety.
Flame scanner The optimal choice of flame monitoring
QRA73
system does not only have to consider
the type of burner and the type of fuel
to be combusted, but also the operatio-
Flame monitor nal aspects of the system and the con-
CFC3..
ditions inside the combustion chamber.
Amplitude
VLoad
electronic module
Frequency
24
Weishaupt Flame Control W-FC
The W-FC (Weishaupt Flame Control)
flame monitoring system is a reliable
monitoring system which satisfies
the most demanding requirements
and can also be used for continuous
operation.
W-FC 4.0 is for plant with multiple W-FC 5.0 can be used for plant with
burners firing from the same direction multiple burners firing from different
into a single combustion chamber. directions into a single combustion
The W-FC assembly utilizes flame chamber and for process plant with
frequency to distinguish each flame various flame sources. The W-FC sys-
separately The CFC3... flame sensor tem monitors each flame separately via
works in conjunction with the QRA73 a load-dependent flame relay. This gua-
flame sensor on the W-FM 100 or W- rantees a distinction of flames originate
FM 200 combustion manager. from various sources. The CFC3... flame
sensor works in parallel with the QRA73
Note: If a turndown in excess of 4:1 flame sensor on the W-FM 200 combus-
or single-burner operation is required, tion manager.
the W-FC 5.0 should be used instead.
For classical unison firing into a For firing into a combustion For plant with various flame sour-
combustion chamber, with a chamber from ces, such as incinerator, process
maximum turndown of 4:1 opposing directions and firing of plant, etc.
multiple burners
25
Emissions reduction:
The multiflam® principle - version 3LN
The multiflam® Flame shows efficient combustion Primary and secondary flames with internal circulation
26
Ignition pilot line
Ignition electrodes
Flame tube
27
WK burner in hot air version up to 480F (250°C)
Efficiency increase up to 10 percent
Cooling fan
Air pre-heater
4 3
2
5
1 Q
Combustion air
fan
28
Nitrogen oxides reduction with multiflam® burner
in hot air version up to 480F (250°C)
NR
3LN
4LN
Cooling air for actuator and flame sensor
New in the multiflam® and 4LN NOx emission values of WK burners in hot air version
Comparison: NR and multiflam® 3LN without flue gas recirculation vs 4LN (with FGR)
burners is the use in the hot air
sector.
Combustion efficiency improvement by air pre-heating
Heat generators with very high medium
temperatures can extract less heat 480F
Combustion air preheating [F/ °C]
Efficiency Efficiency
with without
air preheating ηF + 5.5 % air preheating
29
4LN mixing head on WK series burner – further development of the 3LN multiflam® mixing head
30
Ultra LowNOx values in high capacity:
WK burner in 4LN version
Weishaupt 4LN gas burners are an Weishaupt systems with flue gas Service work, easy as usual.
innovative development to meet the recirculation do not require an addi- The system components of the flue gas
worldwide stringent NOx require- tional fan to supply exhaust gas/ flue recirculation only affect the blower.
ments. gas to the burner. The burner remains unchanged and so
New in this development is the general The combustion air fan takes over the does the handling during commissioning
integration of an external exhaust gas intake of the exhaust gas. The mixing and maintenance. This saves time and
recirculation. The burner's mixing head box creates a negative pressure that costs.
assembly is based on the well-known allows the exhaust gas to flow into the
multiflam® technology and is specially blower through the exhaust pipe. The
optimized for operation with flue gas control unit of the combustion manager
recirculation. takes care of the optimal quantity dosing
Test bench and practical values prove with the help of a control damper.
that with this technology the NOx
requirements of 15 ppm (natural gas)
can be satisfied under specified condi-
tions.
M
Flue gas line Insulation Isolation device
L
PE
N
L
L
L
min.
max.
(CPI)
L
PE
N
L
L
L
L
ION
FSV/QRI
PE
N
L
Power QRI
QRB
L
N
G0
G
LT
LINE
12VAC
1
1
OIL
Compensator
GAS
V1
PV
SV
V2
V1
V1
FLAME
FGR function
PE
/ -
X7-01
V2
OIL
-20°C to + 60°C
V3
- 4°F to +140°F
PE FCC: part 15, Class B
X7-03
GAS
Mixingbox
OXYGEN CONTROL Sauerstoffregler
PE
/ -
X6-02
IEC 127-2/V
1P
F1/T6,3
PE
/ -
X6-03
S 1312120025
SV
OIL
(START)
FLANGE
SAFETY
RESET
IGNITION
VOLTAGE
MOTOR
ALARM
LOOP
L
1
1
LINE
ON/OFF
1
3
2
GAS
max
min
OIL
INT
PE
PE
PE
PE
PE
N
N
L
L
L
L
L
FGR temp sensor X5-01 X5-02 X5-03 X4-01 X4-02 X4-03 X3-01 X3-02 X3-03 X3-04
Principle construction of WK burner with mixing box and flue gas recirculation
31
Weishaupt flue gas recirculation system:
Combustion blower fan with mixing box
Weishaupt mixing box Advantages: Variable speed drive
The mixing box is fabricated in coope- Mixing box is an integral part of com- Also for project equipped with variable
ration with blower manufacturer. It is bustion blower fan speed drive, as standard Weishaupt
attached directly to the combustion air Installation time on site is substantial- provides speed sensor for the combus-
blower and forms a compact assembly ly reduced due to integral design tion blower fan’s motor. This ensures
with fixed dimensions. It consists of a correct rotational direction and conti-
housing with attached air damper sucti- nous fan speed monitoring.
on control and provision to mount FGR
damper.
Speed sensor
Example of combustion blower fan with mixing box Motor with speed sensor
The pictures show example of combustion blower fan with mixing box in European version for reference only
32
Flexible compensator Mixing box damper for
suction control
Actuator
Actuator coupling
FGR damper
Temperature
sensor
Mixing box
h3
G 3/4“
DN h1 h2
2.4“
(60) ZM-..
l2
l1
l6
optional textile
compensator l4 l5
l9 l10
l7
l8 Version ZMH
h3
l11 4.7“
ZMH-..
(120)
Ø3.5“
l12 (90)
l13 l14
Weishaupt reserves the right to make any changes as necessary for further product development
34
Installation at heat exchanger
The void must be filled with flexible high temperature insulati-
l15 on material (e.g.: cerafelt, fiber wool, etc.)
60°-9
90°
Service-friendly flame head assembly:
The flame head in the standard length can be (de) mounted on all burner
types through the service opening on the burner housing.
1)
Flame tube extension is available as an option
d1 d 2 d3
l16
WK.. 50/1 NR / 1LN 11.4 (290) 15.0 (380) 15.4 (390) 12.1 (307) ≥ 0
9.6“ (245)
7.1“ (180)
WKG(L) 50/1 3LN 11.7 (296) 15.0 (380) 15.4 (390) 15.0 (380) ≥ 2 (50)
10.6“ (270)
7.9“ (200)
WK.. 50/2 NR 13.8 (350) 15.0 (380) 15.4 (390) 13.3 (337) ≥ 0
WKG(L) 50/2 1LN 13.8 (350) 15.0 (380) 15.4 (390) 17.8 (452) ≥ 0
WKL(MS) 50/1 11.4 (290) 15.0 (380) 15.4 (390) 13.3 (337) ≥ 0
M12 M12
WKL(MS) 50/2 13.8 (350) 15.0 (380) 15.4 (390) 15.4 (392) ≥ 0
WKG(L) 50/2 3LN 13.5 (344) 15.0 (380) 15.4 (390) 19.7 (501) ≥ 2 (50)
WK.. 50/2 1SF 13.8 (350) 15.0 (380) 15.4 (390) 13.3 (337) ≥ 0
Ø11.4“ (290) Ø15.4“ (390)
WK.. 70/1 NR 15.7 (400) 20.4 (518) 20.9 (530) 13.7 (347) ≥ 0 Ø12.6“ (320) - (LN)
WK.. 70/3 NR 18.9 (480) 20.4 (518) 20.9 (530) 18.2 (462) ≥ 0
WK 40 WK 50
WKG 70/1 LN 16.0 (406) 20.4 (518) 20.9 (530) 18.0 (457) ≥ 0
WKG(L) 70/1 1LN 16.0 (406) 20.4 (518) 20.9 (530) 17.3 (439) ≥ 0
WKG(L) 70/2 LN / 1LN 18.9 (480) 20.4 (518) 20.9 (530) 18.8 (477) ≥ 0
WKG(L) 70/0 3LN 16.1 (409) 20.4 (518) 20.9 (530) 18.6 (472) ≥ 2.4(60)
Ø28.9“ (735) Ø34.4“ (875)
WKG(L) 70/1 3LN / 4LN 17.5 (444) 20.4 (518) 20.9 (530) 18.7 (475) ≥ 2.4(60) Ø30.3“ (770)
WKG(L) 70/3 3LN / 4LN 18.9 (480) 20.4 (518) 20.9 (530) 18.7 (475) ≥ 2.4(60)
WK.. 70/1 1SF 15.7 (400) 20.4 (518) 20.9 (530) 13.7 (347) ≥ 0
°
°
30
30
WK.. 70/2 1SF 18.9 (480) 20.4 (518) 20.9 (530) 14.3 (362) ≥ 0
3 0°
3 0°
WKL(MS) 70/1 15.7 (400) 20.4 (518) 20.9 (530) 16.4 (417) ≥ 0
WKL(MS) 70/2 18.9 (480) 20.4 (518) 20.9 (530) 16.6 (422) ≥ 0
30°
3 0°
WK.. 80/3 NR 23.2 (590) 23.2 (590) 25.2 (640) 19.7 (500) ≥ 0
M16 ° M16 °
WKG(L) 80/1 3LN / 4LN 21.3 (540) 22.0 (558) 25.2 (640) 20.1 (510) ≥ 2.8 (70) 30 30
WKG(L) 80/2 3LN / 4LN 21.3 (540) 22.0 (558) 25.2 (640) 20.1 (510) ≥ 2.8 (70)
WK.. 80/3 1SF 23.6 (600) 23.6 (600) 25.2 (640) 18.9 (480) ≥ 0
Ø20.9“ (530) Ø25.2“ (640)
WKG 80/4 VSF 23.2 (590) 23.2 (590) 25.2 (640) 19.7 (500) ≥ 0 Ø25.6“ (650) - (3SF)
WKG 80/5 VSF 23.2 (590) 23.2 (590) 25.2 (640) 19.7 (500) ≥ 0
WKG 80/6 3SF 24.3 (618) 24.3 (618) 25.2 (640) 19.7 (500) ≥ 0 WK 70 WK 80
35
Options, mounting possibilities and
weight in an overview
Vertical Weishaupt burners (based Vertical version
on ZMH burners) are specially
designed for use with systems with
vertical construction such as steam
boilers, thermal oil heaters and
various heat exchangers for pro-
cess application.
Option
Option
Expanded Option (with accessories)
36
Burner weights7) in lbs and (kg)
WKG WKL WKMS WKGL WKGMS
WK.. 40 264 308 3) / 275 5) 363 3,4) / 286 5,6) 330 3) / 297 5) 374 3,4) / 308 5,6)
(120) (140) 3) / (125) 5) (165) 3,4) / (130) 5,6) (150) 3) / (135) 5) (170) 3,4) / (140) 5,6)
WK.. 50 363 352 363 363 374
(165) (160) (165) (165) (170)
WK.. 70 638 638 660 682 704
(290) (290) (300) (310) (320)
WK.. 80 968 924 946 1012 1034
(440) (420) (430) (460) (470)
3) mounted oil pump 4) mounted oil pre-heater 5) separate oil pump 6) separate oil pre-heater. 7) Weights are approximate only
37
That is not an Imagination. Continuous research
and development at Weishaupt ensure environ-
mental friendly and efficient burners.
That is Reliability.
38
Developing improvement.
Weishaupt recognizes the signs of
time and researches perpetually to
get more efficient and environmen-
tal friendly burner systems.
39
Weishaupt Corporation Weishaupt America Inc. Weishaupt America Inc.
2925 Argentia Road 2587 Millenium Drive, Unit A 1320 Ellsworth Industrial Blvd.
Mississauga, ON L5N 8G6, Canada Elgin, IL 60124, USA Atlanta, GA 30318, USA
Ph: (905) 564 0946 Ph: (847) 531 5800 Ph: (404) 968-2935
Fax: (905) 564 0949 Fax: (847) 531 5855 Fax: (404) 968-2966
www.weishaupt-corp.com www.weishaupt-america.com www.weishaupt-america.com