R1) In Table A-1 corresponds = Max spacing of 400 o/c for 38 x 235 joist.
Thus, 2x10 (38x235) @ 24 (600) is not the permitted spacing CANNOT BE USED @24”
R1) In Table A-1 corresponds = Max spacing of 400 o/c for 38 x 235 joist.
R: In Table A-1 corresponds = Max spacing is NOT ALLOWED for this span. It must be 5.28 m max.
R: In 9.23.14.7 states: Lumber subflooring shall be laid at an angle not less than 45° to the floor joists.
SO IT IS ALLOWED TO INSTALL IT 90° (right angle). Lumber is stronger in that direction.
SJL = 4.3m
1 column to the middle distance generates 2 equal spans, each one 6300 (6.3m)
R: W250 x 33 (Max. span 6300) – W250 x 39 CAN SATISFY THE LOADING CONDITIONS.
Using 3 columns, it generates 4 equally beam spans of 12.6/4 = 3.15 m (3.2 in Table 9.23.4.3 @ 600)
Construction Methods & Materials 1 – Assignment 1 - LMoran
- Commercial designation
- Joist size