Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

NOTES

1. This drawing is copyright


2. Do not scale off this drawing
3. All levels and dimensions to be checked on
A B C D E F G H I site before any building work commences

BIODIGESTER TO 100Ø 100Ø 100Ø 4. Any discrepancies to be reported to the


SPECIALIST DETAIL FWMH FWMH FWMH FWMH office of the consultant
5. All work to be strictly in accordance to
100Ø with the standard specifications and notes
6. This drawing is to be read in conjunction
75Ø mm RWPD with specifications & other relevant drawings
PV GT

FWMH
1 100Ø mm SVP 100Ø 100Ø
1 7. Walls below 200mm thick to be reinforced
with hoop iron at every alternate course
8. Drain pipes passing under tarmac,
PV driveways, and buildings to be encased in
YARD 150mm thick concrete sorround

LAUNDRY
100Ø mm SVP
50Ø GT 9. All reinforced concrete work to

WORKTOP
2 GT 2 Structural Engineer's drawings

IRONING
FT
SD 10. All sanitary works to the entire
75Ø mm SVP
STAIRCASE

W
satisfaction of MoH
PV 40Ø
40Ø
BATH 100Ø
11. All roads, storm water drainage & foul

GUEST Sewerage to Civil Engineer's drawings

DR
10

high level cabinet 11 9


BEDROOM
3 8
3
KITCHEN
12
SHELVES 7
PV

RG
13
6
PV 14

4 15 5
4
4

PANTRY
SHELVES
16
3

SLANTING SHELVES
17 PV

F
2
WADROBE

COFFEE

FWMH
18
1 GT
5

high level cabinet


32Ø 5

AREA
BAR
high level
75Ø mm

cabinet
FT
40Ø PIPE CAST 100Ø
IN SLAB
PV WC PV
6 6
PV
FWMH

100Ø mm SVP
REVISIONS
7 7
100Ø

DINING
GT PD
LOUNGE
32Ø
8 8
PV PROJECT

PROPOSED RESIDENTIAL HOUSE IN

OUTDOOR CLIENT
75Ø mm RWPD
DINING
9 PV 9
PV

PORCH ARCHITECT

10 10
SERVICES ENGINEERS

A B C D E F G H I DRG.TITLE

MECHANICAL SERVICES
DRAINAGE LAYOUT
GROUND FLOOR
DATE; SCALE
SEPT' 2022 N. T. S.
DRAWN BY CHECKED BY
E.A EA
DRG.No.

2206-BEATRICE-P&D-001- (REV0)
GROUND FLOOR PLAN LAYOUT
NOTES

A B C D E F G H I 1. This drawing is copyright


2. Do not scale off this drawing
3. All levels and dimensions to be checked on
site before any building work commences
4. Any discrepancies to be reported to the
office of the consultant

PV 5. All work to be strictly in accordance to

1 40Ø RM
25Ø PIPE FA 1 with the standard specifications and notes
6. This drawing is to be read in conjunction
with specifications & other relevant drawings
PV
YARD 7. Walls below 200mm thick to be reinforced

LAUNDRY
with hoop iron at every alternate course
8. Drain pipes passing under tarmac,

WORKTOP
2 2

IRONING
25Ø PIPE FA driveways, and buildings to be encased in
150mm thick concrete sorround
STAIRCASE

W
PV 25Ø PIPE FA 9. All reinforced concrete work to
BATH Structural Engineer's drawings

GUEST 10. All sanitary works to the entire

DR
10 satisfaction of MoH
high level cabinet 11 9
BEDROOM 11. All roads, storm water drainage & foul
3 UNDERSINK WATER 8
3 Sewerage to Civil Engineer's drawings
KITCHEN
12
SHELVES
HEATER 7
PV

RG
13
6
PV 14

4 15 5
4
4

PANTRY
SHELVES
16
3
PV

SLANTING SHELVES
17

F
2
WADROBE

COFFEE
18
1
5 5

high level cabinet


25Ø PIPE FA

AREA
BAR
high level
20Ø

cabinet
20Ø

PV WC PV
6 6
PV
7 7
REVISIONS

DINING
LOUNGE
8
SUBMERSIBLE PUMPS
20Ø PIPE FA
8
TO SPECS PV

PROJECT

OUTDOOR PROPOSED RESIDENTIAL HOUSE IN


DINING
9 PV 9 CLIENT
PV

15M³ CLEAN PORCH


UNDERGROUND
10
WATER TANK 10 ARCHITECT

25Ø PIPE CONNECTION


FROM CITY COUNCIL
M
WATER METER IN A B C D E F G H I SERVICES ENGINEERS

CHAMBER TO DETAIL

DRG.TITLE

MECHANICAL SERVICES
PLUMBING LAYOUT
GROUND FLOOR
DATE; SCALE

GROUND FLOOR PLAN LAYOUT DRAWN BY


SEPT' 2022
CHECKED BY
N. T. S.
E.A EA
DRG.No.

2206-BEATRICE-P&D-002- (REV0)
NOTES

A B C D E F G H I 1. This drawing is copyright


2. Do not scale off this drawing
3. All levels and dimensions to be checked on
100Ø mm BOXED TO site before any building work commences
ARCHITECT'S DETAIL 4. Any discrepancies to be reported to the
office of the consultant
75Ø mm RWPD
100Ø mm SVP
PV 5. All work to be strictly in accordance to
with the standard specifications and notes
1 1 6. This drawing is to be read in conjunction
with specifications & other relevant drawings
FD
FT 50Ø PIPE CAST 7. Walls below 200mm thick to be reinforced
IN SLAB BALCONY 100Ø mm SVP
with hoop iron at every alternate course

CROAK 8. Drain pipes passing under tarmac,


2 40Ø PIPE CAST
IN SLAB SD SD 2 driveways, and buildings to be encased in
150mm thick concrete sorround
PV 75Ø mm SVP CROAK
PD
PV STAIRCASE 50Ø PIPE CAST
9. All reinforced concrete work to
32Ø 100Ø mm BOXED TO Structural Engineer's drawings
IN SLAB
PD
ARCHITECT'S DETAIL
BEDROOM 2 10. All sanitary works to the entire
satisfaction of MoH
10
9
11. All roads, storm water drainage & foul
11 Sewerage to Civil Engineer's drawings

WARDROBE
40Ø
3 12 8
PV
3
FAMILY 7

BEDROOM 1
13
6

4 ROOM 14
15 5
4
16 4
3
17
2 PV
Decorative partition
18
1
WARDROBE
5 Shelves
32Ø 75Ø mm SVP
5
PV 40Ø PIPE CAST PV
IN SLAB LOW LEVEL CABINET &
6 SHELVES 6
PV
100Ø mm SVP
FT PD PV
7 32Ø
7
REVISIONS
MASTER
BATH
50Ø PIPE CAST
IN SLAB PV WIC
SD

DRESSING
8
PV PV
MASTER 8
BEDROOM PROJECT

PROPOSED RESIDENTIAL HOUSE IN

75Ø mm RWPD
CLIENT

9 9
PV FD

MASTER
BALCONY ARCHITECT

10 10

SERVICES ENGINEERS

A B C D E F G H I
DRG.TITLE

MECHANICAL SERVICES
DRAINAGE LAYOUT
FIRST FLOOR
DATE; SCALE
SEPT' 2022 N. T. S.
DRAWN BY CHECKED BY
E.A EA
DRG.No.

UPPER FLOOR PLAN LAYOUT 2206-BEATRICE-P&D-003- (REV0)


A B C D E F G H I NOTES

1. This drawing is copyright


2. Do not scale off this drawing
32Ø PIPE FA 3. All levels and dimensions to be checked on
25Ø PIPE TB site before any building work commences
4. Any discrepancies to be reported to the
PV office of the consultant
1 40Ø RM 1 5. All work to be strictly in accordance to
25Ø with the standard specifications and notes
32Ø PIPE FA 6. This drawing is to be read in conjunction
25Ø PIPE TB
20Ø
BALCONY 32Ø PIPE FA
with specifications & other relevant drawings

20Ø CROAK 25Ø PIPE TB


7. Walls below 200mm thick to be reinforced
with hoop iron at every alternate course
2 20Ø 2 8. Drain pipes passing under tarmac,
PV
STAIRCASE CROAK
driveways, and buildings to be encased in
PV 150mm thick concrete sorround

20Ø 9. All reinforced concrete work to


BEDROOM 2 Structural Engineer's drawings
10 10. All sanitary works to the entire
11 9 satisfaction of MoH

WARDROBE
3 12 8
PV
3 11. All roads, storm water drainage & foul

BEDROOM 1 FAMILY 13 7
6
Sewerage to Civil Engineer's drawings

4 ROOM 14
15 5
4
16 4
3
17
2 PV
Decorative partition
18
1
WARDROBE
5 Shelves
25Ø PIPE FA 5
PV PV
LOW LEVEL CABINET &
6 25Ø SHELVES 6
PV PV
7 20Ø 7
MASTER
25Ø BATH REVISIONS

PV WIC

DRESSING
20Ø PIPE TB
8 32Ø PIPE FA PV PV
MASTER 8
BEDROOM
PROJECT

PROPOSED RESIDENTIAL HOUSE IN

9 9 CLIENT
PV
MASTER
BALCONY
10 10 ARCHITECT

A B C D E F G H I SERVICES ENGINEERS

DRG.TITLE

MECHANICAL SERVICES
PLUMBING LAYOUT
FIRST FLOOR
DATE; SCALE
SEPT' 2022 N. T. S.
UPPER FLOOR PLAN LAYOUT DRAWN BY
E.A
CHECKED BY
EA
DRG.No.

2206-BEATRICE-P&D-004- (REV0)
A B C D E F G H I NOTES

1. This drawing is copyright


2. Do not scale off this drawing
3. All levels and dimensions to be checked on
site before any building work commences
4. Any discrepancies to be reported to the
office of the consultant
PV
1 40Ø PD 1 5. All work to be strictly in accordance to
with the standard specifications and notes
6. This drawing is to be read in conjunction
50Ø PIPE CAST with specifications & other relevant drawings
IN SLAB 100Ø mm SVP 7. Walls below 200mm thick to be reinforced
PV with hoop iron at every alternate course
2 PV 2

OUTDOOR
8. Drain pipes passing under tarmac,

KITCHEN
driveways, and buildings to be encased in
BARBECUE AREA STAIRCASE
75Ø mm SVP FT 150mm thick concrete sorround
9. All reinforced concrete work to
Structural Engineer's drawings
WC 10. All sanitary works to the entire
50Ø PIPE CAST satisfaction of MoH
IN SLAB
3 3 11. All roads, storm water drainage & foul
Sewerage to Civil Engineer's drawings

PV
4 PV 4
PD

32Ø

5 PV
5

6 6

7 7
REVISIONS

PERGOLA AREA

8 8

PROJECT

PROPOSED RESIDENTIAL HOUSE IN

CLIENT

9 9

ARCHITECT

10 10

SERVICES ENGINEERS

A B C D E F G H I
DRG.TITLE

MECHANICAL SERVICES
DRAINAGE LAYOUT
TERRACE FLOOR
DATE; SCALE
SEPT' 2022 N. T. S.
DRAWN BY CHECKED BY
E.A EA

ROOF TOP LAYOUT DRG.No.

2206-BEATRICE-P&D-005- (REV0)
NOTES
A B C D E F G H I
1. This drawing is copyright
2. Do not scale off this drawing
3. All levels and dimensions to be checked on
site before any building work commences
32Ø PIPE TB 4. Any discrepancies to be reported to the
32Ø PIPE DROP office of the consultant
5. All work to be strictly in accordance to
PV
1 40Ø RM
20Ø
1 with the standard specifications and notes
6. This drawing is to be read in conjunction
with specifications & other relevant drawings
32Ø PIPE TB 7. Walls below 200mm thick to be reinforced
with hoop iron at every alternate course
PV 8. Drain pipes passing under tarmac,
2 PV 20Ø 2 driveways, and buildings to be encased in

OUTDOOR
KITCHEN
150mm thick concrete sorround
BARBECUE AREA PRESSURIZATION PUMP
STAIRCASE
32Ø PIPE TB 9. All reinforced concrete work to
50Ø Structural Engineer's drawings
20Ø
WC 10. All sanitary works to the entire
satisfaction of MoH
11. All roads, storm water drainage & foul

3 3 Sewerage to Civil Engineer's drawings

PV
4 PV 4

2No.1000LITRES PVC ROOF WATER


5 TANK ON BEARERS TO SE DETAILS
PV( 1270mm DIA x 960mm H)
25Ø PIPE TB 5

32Ø PIPE TB
6 6

7 7
REVISIONS

PERGOLA AREA

8 8

PROJECT

PROPOSED RESIDENTIAL HOUSE IN

CLIENT

9 9

ARCHITECT

10 10

SERVICES ENGINEERS

A B C D E F G H I
DRG.TITLE

MECHANICAL SERVICES
PLUMBING LAYOUT
TERRACE FLOOR
DATE; SCALE
SEPT' 2022 N. T. S.
DRAWN BY CHECKED BY
E.A EA

ROOF TOP LAYOUT DRG.No.

2206-BEATRICE-P&D-006- (REV0)