Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Vietnam Nisshin Technomic

Contract Job Code 0-8850-20-0000


VIETNAM NISSHIN
TECHNOMIC PHASE 2 Project Doc. No. C-000-1344-104
PROJECT Rev. 0 Page 1 of 7

Document Class 2

FAN STATIC PRESSURE


CALCULATION FOR FIRE SMOKE
EXHAUST SYSTEM

Rev. Date Description Prepared by Checked by Approved by


0 4-Mar-22 Issued for information N.Thuat E.Yamamoto N.Tamura
Project Doc. No.
VIETNAM NISSHIN FAN STATIC PRESSURE C-000-1344-104
TECHNOMIC CALCULATION FOR FIRE SMOKE
PHASE 2 PROJECT EXHAUST SYSTEM Rev. A Page 2 of 7

REVISION HISTORY
Rev. Section Page Description

HOLD List
No. Section Page Description
1 SCOPE
This is Excel Document Template

2 REFERENCE DOCUMENT
The following documents shall be referred to where required.
Document Number Document Title

3 DEFINITIONS & ABBREVIATIONS


3.1 Definitions
The following definitions shall be applied for this project.
Project Vietnam Nisshin Technomic Phase 2 Project
Owner Vietnam Nisshin Technomic Co.,Ltd
JGC Corporation and JGC Vietnam who undertakes the Engineering,
Contractor
Procurement and Construction (EPC) activity for the Project.
Awarded Bidder who is selected and employed by Purchaser to supply
Vendor
the designated Equipment / Material.
Subcontractor Engineering or Construction Subcontractor.

3.2 Abbreviations
The following definitions shall be applied for this project.
YOC Yokohama Operation Office
HOC Hanoi Operation Center
J-DMS JGC Document Management System
PROJECT NAME VIETNAM NISSHIN TECHNOMIC PHASE 2 Revision: 0
WORK CODE : Date:
TOPIC : PRESSURE CALCULATION FOR FIRE SMOKE EXHAUST SYSTEM Applied Standard:
DESIGNED BY : LÊ VĂN ĐẠT
CHECK BY : NGUYỄN THÀNH TRUNG
APPROVER : NGUYỄN THÀNH TRUNG

Chosse fan
Equipment Tag No SEF-01,2,3,4
Name Equipment Smoke Exhaust fan
Location 1F
Air Flow 80000 m3/h
Pressure 850 Pa

Pressure Caculation

Air Width a Hight b Area F Velocity Equivalent Length Duct pressure Local Summary of Velocity Pressure Section Total
Flow L (mm) (mm) (m2) V diameter L loss coefficient fitting loss pressure loss along pressure Pressure
Duct section (m3/h) (m/s) Dtd (mm) (m) R (Pa/m) Type of fitting ξ coefficient
  Pđ the way loss Pcb loss P
ξ (Pa) Pdd (Pa) (Pa)
(Pa)
PRESSURE LOSS BEFORE FAN

SH1-SH2 16000 1,000 800 0.800 5.56 888.89 7.00 0.36 SH 1.80 2.20 9.524 2.52 20.953 23

DAMPER 0.40

SH2-SH3 32000 1,000 800 0.800 11.11 888.89 6.80 1.31 TEE 2.23 2.23 38.028 8.91 84.802 94
SH3-SH4 48000 1,000 800 0.800 16.67 888.89 6.80 2.7 TEE 0.95 1.02 85.613 18.36 87.325 106
REDUCE 0.07
SH4-SH5 64000 1,400 800 1.120 15.87 1018.18 7.00 2.1 TEE 0.57 0.65 77.593 14.70 50.435 65
TRANSITION 0.08
SH5-FAN 80000 1,600 800 1.280 17.36 1066.67 31.50 2.32 TEE 0.38 2.73 92.847 73.08 253.472 327
ELBOW (4 NOS) 1.00
REDUCE 0.25
TRANSITION (2 NOS) 0.60
FAN INLET 0.50
PRESSURE LOSS AFTER FAN
80000 2,100 1,200 2.520 8.82 1250 3.00 2.6 FAN OUTLET 0.50 2.95 23.967 7.80 70.703 78.5
REDUCE 0.50
ELBOW 0.50
TRANSITION 0.45

INSECT SCREEN 1.00

∑P 693

Safety factor 1.2


Total pressure loss (round up) 850
PROJECT NAME VIETNAM NISSHIN TECHNOMIC PHASE 2 Revision: 0
WORK CODE : Date:
TOPIC : PRESSURE CALCULATION FOR FIRE SMOKE EXHAUST SYSTEM Applied Standard:
DESIGNED BY : LÊ VĂN ĐẠT
CHECK BY : NGUYỄN THÀNH TRUNG
APPROVER : NGUYỄN THÀNH TRUNG

Chosse fan
Equipment Tag No SEF-05
Name Equipment Smoke Exhaust fan
Location 1F
Air Flow 57000 m3/h
Pressure 900 Pa

Pressure Caculation

Duct section Air Width a Hight b Area F Velocity Equivalent Length Duct pressure Type of fitting Local Summary of Velocity Pressure Section Total
Flow L (mm) (mm) (m2) V diameter L loss coefficien fitting loss pressure loss along pressure Pressure
(m3/h) (m/s) Dtd (mm) (m) R (Pa/m) t ξ coefficient Pđ the way loss Pcb loss P
(Pa) Pdd (Pa) (Pa)
  (Pa)
ξ

PRESSURE LOSS BEFORE FAN

SH1-SH2 14250 1,500 300 0.450 8.8 500 9.00 1.7 SH 1.80 2.27 23.858 15.30 54.158 69
DAMPER 0.35
REDUCE 0.08
TRANSITION 0.04
SH2- TEE 28500 1,600 300 0.480 16.49 505.26 10.60 5.4 TEE 0.80 1.01 83.774 57.24 84.612 142
ELBOW 0.15
TRANSITION 0.06
TEE- FAN 57000 2,000 450 0.900 17.59 734.69 35.00 3.8 TEE 1.65 3.35 95.324 133.00 319.335 452
ELBOW (4 NOS) 0.80
FAN INLET 0.50
REDUCE 0.15
TRANSITION (2 NOS) 0.25
PRESSURE LOSS AFTER FAN
57000 1,600 1,000 1.600 9.9 1230.77 2.00 0.69 FAN OUTLET 0.50 2.65 30.195 1.38 80.017 81.4
REDUCE 0.30
TRANSITION 0.60
ELBOW (2 NOS) 0.25
INSECT SCREEN 1.00
∑P 745

Safety factor 1.2


Total pressure loss (round up) 900
PROJECT NAME VIETNAM NISSHIN TECHNOMIC PHASE 2 Revision: 0
WORK CODE : Date:
TOPIC : PRESSURE CALCULATION FOR FIRE SMOKE EXHAUST SYSTEM Applied Standard:
DESIGNED BY : LÊ VĂN ĐẠT
CHECK BY : NGUYỄN THÀNH TRUNG
APPROVER : NGUYỄN THÀNH TRUNG

Chosse fan
Equipment Tag No SEF-06
Name Equipment Smoke Exhaust fan
Location 1F
Air Flow 45000 m3/h
Pressure 800 Pa

Pressure Caculation

Air Width a Hight b Area F Velocity Equivalent Length Duct pressure Local Summary of Velocity Pressure Section Total
Flow L (mm) (mm) (m2) V diameter L loss coefficien fitting loss pressure loss along pressure Pressure
Duct section (m3/h) (m/s) Dtd (mm) (m) R (Pa/m) Type of fitting t ξ coefficient
  Pđ the way loss Pcb loss P
(Pa) Pdd (Pa) (Pa)
ξ
(Pa)
PRESSURE LOSS BEFORE FAN

SH1- TEE 11250 800 600 0.480 6.51 685.71 11.00 0.66 SH 1.80 3.00 13.057 7.26 39.171 46

DAMPER 0.40
REDUCE 0.15
TRANSITION 0.20
ELBOW 0.45
TEE- TEE 22500 1,200 600 0.720 8.68 800 11.00 0.93 TEE 0.80 2.97 23.212 10.23 68.94 79
ELBOW (2 NOS) 0.85
TRANSITION 0.80
VALVE 0.52
TEE- TEE 33750 1,400 600 0.840 11.16 840 0.50 1.39 TEE 0.95 0.95 38.371 0.70 36.452 37
TEE-FAN 45000 1,400 600 0.840 14.88 840 39.00 2.4 TEE 0.80 4.92 68.214 93.60 335.613 429
FAN INLET 0.50
VALVE 0.52
REDUCE 0.45
ELBOW (6 NOS) 1.85
TRANSITION (2 NOS) 0.80
PRESSURE LOSS AFTER FAN
45000 1,600 1,000 1.600 7.81 1250 1.00 0.45 FAN OUTLET 0.50 3.75 18.792 0.45 70.47 70.9
REDUCE 1.10
TRANSITION 0.65
ELBOW 0.50
INSECT SCREEN 1.00
∑P 663

Safety factor 1.2


Total pressure loss (round up) 800
PROJECT NAME VIETNAM NISSHIN TECHNOMIC PHASE 2 Revision: 0
WORK CODE : Date:
TOPIC : PRESSURE CALCULATION FOR FIRE SMOKE EXHAUST SYSTEM Applied Standard:
DESIGNED BY : LÊ VĂN ĐẠT
CHECK BY : NGUYỄN THÀNH TRUNG
APPROVER : NGUYỄN THÀNH TRUNG

Chosse fan
Equipment Tag No SEF-07
Name Equipment Smoke Exhaust fan
Location 1F
Air Flow 54000 m3/h
Pressure 1000 Pa

Pressure Caculation

Air Width a Hight b Area F Velocity Equivalent Length Duct pressure Local Summary of Velocity Pressure Section Total
Flow L (mm) (mm) (m2) V diameter L loss coefficien fitting loss pressure loss along pressure Pressure
Duct section (m3/h) (m/s) Dtd (mm) (m) R (Pa/m) Type of fitting t ξ coefficient
  Pđ the way loss Pcb loss P
ξ (Pa) Pdd (Pa) (Pa)
(Pa)
PRESSURE LOSS BEFORE FAN

SH- TEE 13500 1,000 500 0.500 7.5 666.67 10.50 0.89 SH 1.80 3.68 17.33 9.36 63.774 73
DAMPER 0.40
ELBOW (2NOS) 1.20
TEE 0.28
TEE- TEE 27000 1,200 600 0.720 10.42 800 12.00 1.30 TEE 2.00 2.38 33.451 15.60 79.613 95
ELBOW 0.26
REDUCE 0.12
TEE- TEE 54000 1,500 600 0.900 16.67 857.14 28.00 2.85 TEE 0.33 0.78 85.613 79.80 66.778 147
VALVE 0.20
ELBOW 0.25
TEE- FAN 54000 1,500 600 0.900 16.67 857.14 30.00 2.85 TEE 0.57 3.59 85.613 85.53 307.351 393
MOTOR DAMPER 0.52
FAN INLET 0.50
REDUCE 0.24
ELBOW (4 NOS) 1.60
TRANSITION 0.16
PRESSURE LOSS AFTER FAN
54000 1,600 1,000 1.600 9.38 1250 1.00 0.63 FAN OUTLET 0.50 3.75 27.107 0.63 101.651 102.3
TRANSITION 0.65
REDUCE 1.10
ELBOW (2 NOS) 0.50

INSECT SCREEN 1.00

∑P 810

Safety factor 1.2


Total pressure loss (round up) 1000