Birch-King Flow Direction
Birch-King Flow Direction
50% Grade
Concrete Bridge Rail Transition, Concrete Bridge Modified Guardrail Transition, EXISTING STRUCTURE
Type TFC (Typ.) Railing, Type FC Type TGB (Typ.)
To be Removed. Twin 114" Diameter Multi-Plate Pipes
Under Fill. Bridge Roadway Width 21'-0", No Skew.
Gravel Roadway
1.5 1.5
1 1
14" Dia. Pipe Piles, 0.250" Driven to
200 Kips Nominal Driving Resistance
(Typ. Bent No. 1 & No. 4)
West East
End End
14" Dia. Pipe Piles, 0.250" with
18" Revetment Riprap
Driven to 260 Kips Nominal Driving
over Geotextiles
Resistance (Typ. Bent No. 2 & No. 3)
Span A Span B Span C
1'-6"
Dead Load increased 35 psf for Future Wearing Surface.
Design Strengths
Concrete Bridge Rail 2'-6" (Typ.) 2'-6" (Typ.) To be in Accordance with AASHTO LRFD Bridge Design Specifications, 6th
Transition, Type TFC Edition, 2013, and its Subsequent Iterims.
6" Pavement (Typical all four corners) 20'-6" RCBA (Typ)
Ledge (Typ.) Reinforcing Steel (Grade 60) fy = 60,000 psi
1'-6"
Asphalt Taper Limits to
be Determined on Site The Present Structure Shall be Removed in its Entirety to Facilitate Placing
Flow Direction
(Typ.) Modified Guardrail Terminal of the New Structure.
Birch-King
System, W-Beam Curved, Type 3
(Typical all four corners) Horizontal and Vertical Alignment Based on Field Survey Completed by R.L.
McCoy.
Bent No. 1 Bent No. 2 Bent No. 3 Bent No. 4 Limits of Asphalt Taper and Field Entrance Reconstruction to be Determined
N 5,094.814 N 5,080,867 N 5,063.201 N 5,049.254 on Site.
E 4,979.310 E 4,996.967 E 5,019.331 E 5,036.987
Elev. 103.28 Elev. 102.72 Elev. 102.01 Elev. 101.44
PROPOSED PLAN
Scale: 1/8" = 1'-0"
CONTROL POINTS
31'-0" Out to Out Coping POINT N E Z
Limits of Surface
Seal (Typ.)
Structure
Profile Grade
2% Slope 2% Slope
CONTINUOUS REINFORCED CONCRETE SLAB
3 SPANS: 22'-6"; 28'-6"; 22'-6"
28'-0" CLEAR ROADWAY WIDTH; NO SKEW
1'-4"
CR 150S OVER BIRCH-KING
6" (Typ.) 3/4" Half Round
Drop Bead (Typ.)
PROPOSED SECTION
Scale: 3/8" = 1'-0"
4'-0" 4'-0"
1'-0"
1'-6"
Geotextiles 18" Revetment Riprap
Top of Pile
Flow Flow
Thrie Beam Terminal W-Thrie Beam
Line Line
Connector Transition Section
2'-0" Min.
10'-0"
Plain Concrete
Scale: 1/2" = 1'-0"
L i mi t s o
f Mo
Bottom of Pile dif
i ed
Cu
SECTION A-A rv
ed
Scale: 3/4" = 1'-0"
W
-B
ea
m
Gu
ar d
ra i
1'-2"
l Te
A Class "A" Concrete '-6"
R8
rmi na l System
14" Dia. Epoxy
Coated Steel Pile.
See Section A-A for 6 - #6 Bars (Equal Spacing)
Epoxy Coating Limits. See Section A-A for
Cl. Reinforcement Limits
2"
2 1/2" Cl.
404E #7E x 20'-6" 402E
#5e Threaded Tie #8E x 12'-9" 801E #5E x 16'-9" 602E Support Bar
801E #4E x 14'-6" #4E x 14'-0"
Bar Assembly 405E @ 8" O.C. @ 2'-8" O.C.
1'-2"
1'-4"
3'-8" Lap (Min.)
3'-10" Min.
1'-6" Min.
1" Cl.
403E 402E
3" 2 Eq. Spa.
2'-8" Min.
#5E x 16'-9"
2'-6" Min.
#9E's 701E #6E x 15'-9" #7E x 32'-3" #7E x 20'-0"
402E #9E's
@ 8" O.C.
2" Cl. (Typ)
401E
14" Dia. SEC
Piles
14" Dia. SEC Piles
1'-3" 1'-3"
2'-6" 4'-3"
31'-0"
2 Spa.
1'-6" 5 Spaces @ 12" O.C. 1'-6" @ 12" O.C. 3"
Bent No. 1 Elev. = 103.28 (Typ.) 11" = 5'-0" (Typ.) 11" (Typ.) = 2'-0" (Typ.)
4 - 801E Bent No. 4 Elev. = 101.44 Bent No. 1 Elev. = 102.97
(See Section) Bent No. 4 Elev. = 101.13
30 - 404E
Embed. (Typ)
30'-6"
1'-0" Pile
10"
3'-10"
30 - 401E & 403E 11" 11"
30 - 402E 25'-0"
701E 801E
#7E x 25'-10" #8E x 32'-4"
7 - #9E x 30'-6"
(See Section)
10 5/8"
6 Eq. Spaces = 14'-0"
12"
4 - 14" Dia. SEC Pile
31'-0"
2 Spa. @ 20" 28" 28" 6"
1'-6" 3 Spaces @ 12" O.C. 1'-6" 11" O.C. = 3" 8"
(Typ.) 11" = 3'-0" (Typ.) 11" (Typ.) 1'-10" (Typ.) 6" 10 5/8"
Bent No. 2 Elev. = 102.72
4 - 801E (See Bent No. 3 Elev. = 102.01 Bent No. 2 Elev. = 102.41
26" 2'-6"
Section) Bent No. 3 Elev. = 101.70
404E 405E 406E
30 - 402E #4E x 3'-0" #4E x 8'-2" #4E x 7'-10"
2'-10"
30 - 405E
8" 8"
30 - 402E
8"
40"
Embed. (Typ)
40"
1'-0" Pile
6 - #9E x 30'-6" 28" 26"
(See Section) 8"
26"
5 - 14" Dia. SEC Pile
401E 402E 403E
#4E x 9'-2" #4E x 3'-6" #4E x 4'-8"
2'-10" 4 Spaces @ 6'-4" = 25'-4" 2'-10"
3"
#7E 64 20'-6"
9"
#7E 30 20'-0"
15 Spaces @ 12" O.C. = 15'-0" (701E or #7E) 3" 3" 15 Spaces @ 12" O.C. = 15'-0" (#4E or #7E)
99 - 406E (Space Total #7 Epoxy Coated Bars 9,397#
w/Transverse Bars,
2'-11"
9" 14 Spaces @ 12" O.C. = 14'-0" (#6E or #7E) 9" 9"
#4E 64 14'-6"
Min.
Lap
9"
#4E 32 14'-0"
Total #4 Epoxy Coated Bars 3,378#
SHOWING
BOTTOM BARS
CONCRETE
Concrete, Class C, Superstructure 141.3 CYS
MISCELLANEOUS
113 - #5E x 16'-9" Threaded Tie Bar Assembly, Epoxy
32 EA
Coated, #5E
Surface Seal 5,815 SFT
Structural Backfill - Type 4 13 CYS
9"
3"
3'-8" Min.
8 - #5e x 6'-0" 16 - 701E 15 - #6E x 15'-9" 15 - #7E x 20'-0" 16 - #7E x 32'-3" 15 - #6E x 15'-9" 16 - 701E 8 - #5e x 6'-0"
Lap (Typ.)
Threaded Tie-Bar Threaded Tie-Bar
Assembly 1'-10" 4'-11" 4'-3" 4'-3" 4'-11" 1'-10" Assembly
3'-0" 3'-0"
FLOOR DETAILS
Scale: 1/4" = 1'-0"
31'-0" Out to Out Coping
THREADED TIE BAR ASSEMBLY,
9" 14 Spaces @ 12" O.C. = 14'-0" (#8E) 9" 9" 14 Spaces @ 12" O.C. = 14'-0" (#8E) 9" EPOXY COATED, #5E
Scale: N.T.S.
3" 15 Spaces @ 12" O.C. = 15'-0" (#4E or #7E) 3" 3" 15 Spaces @ 12" O.C. = 15'-0" (#4E or #7E) 3"
2 1/2" Cl.
406E @ 8" O.C. #8E x 12'-9" #5E x 16'-9" Structure #5E x 16'-9" #8E x 12'-9" 406E @ 8" O.C.
@ 8" O.C. @ 8" O.C.
0.048 In.
0.025 In.
Profile Grade
0.048 In.
0.025 In.
0.047 In.
0.055 In.
0.083 In.
0.055 In.
2% Slope 2% Slope
1'-4"
1" Cl.
Bent No. 1 Bent No. 2 Bent No. 3 Bent No. 4
1/4 Pt. 1/2 Pt. 1/4 Pt. 1/4 Pt. 1/2 Pt. 1/4 Pt. 1/4 Pt. 1/2 Pt. 1/4 Pt. #5E x 16'-9" 602E @ 2'-8" O.C. 602E @ 2'-8" O.C. #5E x 16'-9"
701E or #7E 701E or #7E
@ 8" O.C. Alternate Every Other Alternate Every Other @ 8" O.C.
22'-6" 28'-6" 22'-6" Bar #6E or #7E #6E or #7E Bar
3" 15 Spaces @ 12" O.C. = 15'-0" (701E or #7E) 3" 3" 15 Spaces @ 12" O.C. = 15'-0" (701E or #7E) 3"
DEAD LOAD DEFLECTION DIAGRAM
9" 14 Spaces @ 12" O.C. = 14'-0" (#6E or #7E) 9" 9" 14 Spaces @ 12" O.C. = 14'-0" (#6E or #7E) 9"
TYPICAL SECTION
Scale: 1/2" = 1'-0"