GRACE TECHNIC PT. Doc.-No.: FR-7.5.

1-05

JL. MULAWARMAN RT.28 NO.999,BALIKPAPAN - EAST KALIMANTAN - 76115 Rev.: D


Phone : 0542 - 760185, 7581791 ( HUNTING ), Fax : 0542 - 760144
E-mail : info@grace-technic.com Date : 20/09/2016

I N S P E C T I O N R E P O R T
Incoming Insp.
Component Name : FRONT ARM & ROD STEERING Cust. Job No. :
Outgoing Insp.
Part Number : IRF No. : GT / QCT - IRF - / 10 - 2022

Customer: TRAKINDO JOF No. : Add. Job: Yes No

Visual Inspection Magnetic Particle Inspection Hardness Test


Type of Inspection & Test :
Dimensional Penetrant Test Inspection Roughness Test

WI-QP-01_Visual Insp. WI-QP-03_MT Insp. WI-QP-06_Hardness Test


References Procedure:
WI-QP-02_Dimentional Insp. WI-QP-04_PT Insp. WI-QP-07_Roughness Test

Machining Plating Chrome


Type of Job Process : Welding Metal Spray Other (explain)

MAKE NEW RE-SHAFT PIN

Incoming Inspection:
Inspection Points Result of Inspection
Area of Inspection FRONT ARM
REPAIR HOLE PIN ( LINE BORING ) : MAKE NEW (SHAFT PIN) :
1. Ø 75 mm x L 220 ( Qty 2 Ea ) 1. Ø 75 mm x L 220 ( Qty 2 Ea )
2. Ø 90 mm x L 260 ( Qty 2 Ea ) 2. Ø 90 mm x L 260 ( Qty 2 Ea )
3. Ø 90 mm x L 350 ( Qty 2 Ea ) 3. Ø 90 mm x L 350 ( Qty 2 Ea )
4. Ø 70 mm x L 300 ( Qty 2 Ea ) 4. Ø 70 mm x L 300 ( Qty 2 Ea )
5. Ø 120 mm x L 370 ( Qty 2 Ea ) 5. Ø 120 mm x L 370 ( Qty 2 Ea )

SEE ANNEX
ROD STEERING
REPAIR HOLE PIN ( LINE BORING ) : MAKE NEW (SHAFT PIN) :
1. Ø 90 mm x L 360 ( Qty 2 Ea ) 1. Ø 90 mm x L 360 ( Qty 2 Ea )
2. Ø 50 mm x L 200 ( Qty 4 Ea ) 2. Ø 50 mm x L 200 ( Qty 4 Ea )
3. Ø 125 mm x L 250 ( Qty 1 Ea ) 3. Ø 125 mm x L 250 ( Qty 1 Ea )
4. Ø 80 mm x L 220 ( Qty 1 Ea ) 4. Ø 80 mm x L 220 ( Qty 1 Ea )

IMTE used & Unique # Visual Inspection pass fail


- Dimensional Inspection pass fail
Finding Discontinuities NDT Inspection pass fail
DEFECT Specification Standard for Reference :

AS PER PHOTO

Repair Process (if applicable): applicable not appliicable


Inspection Points Result of Inspection
Area of Inspection

Finding Discontinuities Visual Inspection pass fail


Dimensional Inspection pass fail
NDT Inspection pass fail

Post Repair / Outgoing Inspection: pass fail


Inspection Points Result of Inspection
Finding Discontinuities

Acceptance Criteria Visual Inspection pass fail


AS PER DRAWING Dimensional Inspection pass fail

NDT Inspection pass fail

General Remarks:
Incoming Inspection: Post Repair/Outgoing Inspection:
Inspected by : Knowledged by : Inspected by : Knowledged by :

Date : 25-Oct-22 Date : 25-Oct-22 Date : Date :


Inspector : Agus Setiawan Leader : Agus Setiawan Inspector : Leader :
Lvl II NDT Cert. No : Lvl II NDT Cert. No : Lvl II NDT Cert. No : Lvl II NDT Cert. No
- :
Doc.-No.: FR-7.5.1-05
GRACE TECHNIC PT.
JL. MULAWARMAN RT.28 NO.999,BALIKPAPAN - EAST KALIMANTAN - 76115 Rev.: C
Phone : 0542 - 760185, 7581791 ( HUNTING ), Fax : 0542 - 760144
E-mail : info@grace-technic.com Date : 21-Jan-16

A N N E X R E P O R T
BEFORE REPAIR