Perspective: LOT 85-A-10

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

LOT 85-A-10 REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS AND


3 4 HIGHWAYS

N 87°, 55' E, 17.48 M OFFICE OF THE BUILDING OFFICIAL

ALABEL, SARANGANI PROVINCE

LAND USE & ZONING

LOT 85-A-16
N 00°, 23' W, 100.08 M LINE AND GRADE
N 00°, 23' E, 100.32 M
LOT 85-A-6

LOT 85-A-4

02 PERSPECTIVE ARCHITECTURAL
THE SITE A-1 A-1 SCALE NTS

R
LOT 85-A-15
THE SITE
O

R O A D
A

LOT 85-A-13
D

STRUCTURAL

ROAD TO BRGY. ALEGRIA


LOT 85-A-12

R O A D

LOT 85-A-10
LOT 85-A-9

ROAD TO SITIO PAIT

SANITARY
LOT 85-A-1
LOT 85-A-2
LOT 85-A-3
LOT 85-A-4
LOT 85-A-5
LOT 85-A-6
LOT 85-A-8

A B C D
SETBACK

1 LOADING DOCK
INGREDIENT
STORAGE
F I R E W A L L

FF2

FF2

PRODUCTION AREA
PROPOSED ONE-STOREY BAKERY
MANUFACTURING BUILDING FF2 LOT 85-A-7
PACKAGING AREA

2
FF4

R O A D
RELEASING ELECTRICAL
F I R E W A L L

RM.
FF2
OFFICE CR
FF2 WC
LAV
FF2
OFFICE LAV STOCK ROOM STAFF LOCKER
FF1
FF2 WC
RM.
3 STAFF CR FF2
SETBACK

FF4

03 LOCATION PLAN
A-1 A-1 SCALE 1:2500
2 S 87°, 08' W, 17.48
M 1
R O A D MECHANICAL

01 SITE DEVELOPMENT PLAN 03 VICINITY MAP


A-1 A-1 SCALE NTS
A-1 A-1 SCALE 1:500
SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C AR. CHARISSE ALEXIA S. DINOPOL-UAP
SITE DEVELOPMENT PLAN
PERSPECTIVE LOCATION A 01
Contact No. : 09661374892
ARCHITECT VICINITY MAP
Email Add: mcmiguelengineeringservices@gmail.com
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: 0047766 P.T.R. NO.: GS0580333A
SARANGANI PROVINCE
05
T.I.N. NO.: 705-292-344 DATE: 03/30/2023
LEGEND:

4" THK CHB WALL PARTITION

A B C D
6" THK CHB FIREWALL

4" THK REGULAR DRY WALL PARTITION

600MM X 600MM HOMOGENOUS


FF1 PORCELAIN FLOOR TILES

1 FF2 300MM X 600MM VITRIFIED CERAMIC


FLOOR TILES
LOADING DOCK
CONCRETE SMOOTH FINISH W/
INGREDIENT FF3 ANTIMICROBIAL PAINT COATING
STORAGE

F I R E W A L L
FF2
CONCRETE SMOOTH FINISH W/
FF4 ANTIMICROBIAL PAINT COATING

FF2

A PRODUCTION AREA
LEGEND:
FF2

PACKAGING AREA FF4


4" DOWNLIGHT w/ 18W CFL BULB

2
RECESSED LED RECTANGULAR LIGHT
36W 1200 X 300MM
RELEASING
F I R E W A L L

RM.
EMERGENCY LIGHT
FF2 E.L
OFFICE CR
FF2 WC
LAV
FF2
MH 500 X 500 MM MANHOLE
OFFICE LAV STOCK ROOM STAFF LOCKER
FF2 WC
RM.
FF1 FF2
3 STAFF CR EF EXHAUST FAN 6"

FF4
EF EXHAUST FAN 12"

4' X 8' X 9MM THK GYPSUM BOARD IN


CF1 LATEX PAINT SATIN FINISH

B GENERAL NOTES

01 GROUND FLOOR PLAN ALL ARCHITECTURAL PLANS SHALL PREVAIL OVER ALL
ENGINEERING PLANS WITH REGARDS TO DIMENSIONS,
A-2 A-2 SCALE 1:100 ANY DISCREPANCIES FOUND HEREIN SHALL BE
VERIFIED WITH THE ARCHITECT.

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C AR. CHARISSE ALEXIA S. DINOPOL-UAP LOCATION A 02
Contact No. : 09661374892
Email Add: mcmiguelengineeringservices@gmail.com ARCHITECT GROUND FLOOR PLAN
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: 0047766 P.T.R. NO.: GS0580333A
SARANGANI PROVINCE
05
T.I.N. NO.: 705-292-344 DATE: 03/30/2023
03 02 01 03 02 01

A B C D 3 2 1
APEX OF ROOF APEX OF ROOF
TOP OF ROOF TOP OF ROOF

TOP OF ROOF BEAM TOP OF ROOF BEAM

FIN. GROUND FLR. LINE FIN. GROUND FLR. LINE


NATURAL GRADE LINE NATURAL GRADE LINE

01 FRONT ELEVATION 02 RIGHT ELEVATION


A-3 A-3 SCALE 1:100 A-3 A-3 SCALE 1:100

01 02 03
01 02 03
1 2 3
D C B A
APEX OF ROOF
TOP OF ROOF
APEX OF ROOF
TOP OF ROOF

TOP OF ROOF BEAM

TOP OF ROOF BEAM

FIN. GROUND FLR. LINE


NATURAL GRADE LINE
FIN. GROUND FLR. LINE
NATURAL GRADE LINE
03 REAR ELEVATION 04 LEFT ELEVATION
A-3 A-3 SCALE 1:100 A-3 A-3 SCALE 1:100

D E S I G N A T I O N
MARK SPECIFICATION MARK SPECIFICATION

6" THK CHB FIREWALL w/ SMOOTH SKIMCOAT PLASTER


01 GA. 24 RIB-TYPE METAL ROOFING 03 IN SEMI-GLOSS LATEX PAINT FINISH

4" THK CHB w/ SMOOTH SKIMCOAT PLASTER


02 IN SEMI-GLOSS LATEX PAINT FINISH

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C AR. CHARISSE ALEXIA S. DINOPOL-UAP FRONT ELEVATION
LOCATION A 03
Contact No. : 09661374892 RIGHT ELEVATION
Email Add: mcmiguelengineeringservices@gmail.com ARCHITECT REAR ELEVATION NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: 0047766 P.T.R. NO.: GS0580333A LEFT ELEVATION
SARANGANI PROVINCE
05
T.I.N. NO.: 705-292-344 DATE: 03/30/2023
A B C D
APEX OF ROOF
A B C D
TOP OF ROOF

UTILITY SPACE UTILITY SPACE TOP OF ROOF BEAM


UTILITY SPACE

1
BUILDING LINE
RD

PACKAGING AREA PRODUCTION AREA

BUILDING LINE
FIN. GROUND FLR. LINE
NATURAL GRADE LINE

01 SECTION THRU-A
A-4 A-4 SCALE 1:100
SLOPE

2 RD
3 2 1
APEX OF ROOF
TOP OF ROOF

TOP OF ROOF BEAM


UTILITY SPACE UTILITY SPACE

3 BUILDING LINE
RD

OFFICE PRODUCTION AREA

FIN. GROUND FLR. LINE


NATURAL GRADE LINE

02 SECTION THRU-B 03 ROOF PLAN


A-4 A-4 SCALE 1:100 A-4 A-4 SCALE 1:100

D E S I G N A T I O N
MARK SPECIFICATION MARK SPECIFICATION

6" THK CHB FIREWALL w/ SMOOTH SKIMCOAT PLASTER


01 GA. 24 RIB-TYPE METAL ROOFING 03 IN SEMI-GLOSS LATEX PAINT FINISH

4" THK CHB w/ SMOOTH SKIMCOAT PLASTER


02 IN SEMI-GLOSS LATEX PAINT FINISH

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C AR. CHARISSE ALEXIA S. DINOPOL-UAP SECTION THRU-A LOCATION A 04
Contact No. : 09661374892
Email Add: mcmiguelengineeringservices@gmail.com ARCHITECT SECTION THRU-B
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: 0047766 P.T.R. NO.: GS0580333A ROOF PLAN
SARANGANI PROVINCE
05
T.I.N. NO.: 705-292-344 DATE: 03/30/2023
A B C D

1
MH EF

EF

E.L
EF EF
FINISH FLOOR LINE FINISH FLOOR LINE FINISH FLOOR LINE

D D D
01 02 03
E.L

E.L
PVC LOUVERED PANEL DOORS WITH SLITS ON 50MM x
SPECIFICATION HOLLOW CORE PANEL DOOR ON ORDINARY PLYWOOD SPECIFICATION SPECIFICATION GALVANIZED 0.6MM SHUTTER ROLL-UP DOOR
150MM DOOR JAMB

2 EF EF
LOCATION
OFFICE, STOCK ROOM, STAFF LOCKER, RELEASING ROOM
INGREDIENT STORAGE
LOCATION STAFF CR, OFFICE CR LOCATION INGREDIENT STORAGE

NO. OF SETS 8 SETS NO. OF SETS 2 SETS NO. OF SETS 1 SET

EF
F I R E W A L L

MH

EF
E.L

EF

3 FINISH FLOOR LINE FINISH FLOOR LINE FINISH FLOOR LINE FINISH FLOOR LINE

W W W W
01 02 03 04

6MM THK CLEAR GLASS ON


6MM THK CLEAR GLASS ON 6MM THK CLEAR GLASS ON POWDER COATED 6MM THK CLEAR GLASS ON POWDER COATED POWDER COATED
SPECIFICATION POWDER COATED ALUMINUM SPECIFICATION ALUMINUM AWNING WINDOW FRAME SPECIFICATION ALUMINUM AWNING WINDOW FRAME SPECIFICATION ALUMINUM AWNING
SLIDING WINDOW FRAME WINDOW FRAME

LOCATION OFFICE LOCATION PRODUCTION AREA, STAFF LOCKER ROOM LOCATION STOCK ROOM LOCATION OFFICE

NO. OF SETS 1 SET NO. OF SETS 4 SETS NO. OF SETS 1 SET NO. OF SETS 1 SET

01 REFLECTED CEILING PLAN


A-5 A-5 SCALE 1:100

02 SCHEDULE OF DOORS & WINDOWS


A-5 A-5 SCALE 1:100

D E S I G N A T I O N
MARK SPECIFICATION MARK SPECIFICATION

6" THK CHB FIREWALL w/ SMOOTH SKIMCOAT PLASTER


01 GA. 24 RIB-TYPE METAL ROOFING 03 IN SEMI-GLOSS LATEX PAINT FINISH

4" THK CHB w/ SMOOTH SKIMCOAT PLASTER


02 IN SEMI-GLOSS LATEX PAINT FINISH

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C AR. CHARISSE ALEXIA S. DINOPOL-UAP LOCATION A 05
Contact No. : 09661374892 REFLECTED CEILING PLAN
Email Add: mcmiguelengineeringservices@gmail.com ARCHITECT SCHEDULE OF DOORS & WINDOWS NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: 0047766 P.T.R. NO.: GS0580333A
SARANGANI PROVINCE
05
T.I.N. NO.: 705-292-344 DATE: 03/30/2023
400
A. GENERAL NOTES
CONSTRUCTION NOTES CONC. POST 400

400
1. IN THE INTERPRETATION OF THESE DRAWINGS INDICATED DIMENSIONS SHALL
GOVERN AND DISTANCES OR SIZES SHALL NOT BE SCALED FOR CONSTRUCTION
COT. L-SHAPED DOWEL BARS
PURPOSES. TO MATCH CHB HOR. BARS
2. THE CONTRACTOR SHALL COORDINATE WITH THE AR, CE, ME, SE, EE AND OTHER 7. THE REQUIRED LENGTH OF LAP FOR COMPRESSION SPLICES SHALL BE AS SHOWN IN TABLE 4. 2. REINFORCING BARS SHALL 25 mm MINIMUM CLEAR DISTANCE FROM WALL EXCEPT CONC. POST
FOR WALLS DEPOSITED AGAINST THE GROUND WHERE A MINIMUM OF 63 mm SHALL
UTILITIES AND EQUIPMENT PLANS FOR THE EXACT SIZE, NUMBER AND LOCATIONS TABLE - 4 LENGTH OF LAP COMPRESSION SPLICES (mm) BE PROVIDED AND FOR EXPOSED FACES OF FORMED WALLS WHERE THE MINIMUM
OF ALL SLEEVES OR OPENING THRU FLOOR SLABS, BEAMS AND WALLS AND ALSO SHALL BE 50 mm. CLEAR FOR BARS LARGER THAN 16 mm. AND 38 mm FOR 16 mm FOR SIZE AND SPACING
BAR SIZE fc = 28.0 fc = 34.5 fc = 21 BARS OR SMALLER. COT. L-SHAPED DOWEL
OF HOR. & VERT. BARS
DIMENSIONS. (mm) MPa (4000 psi) MPa (5000 psi) MPa (3000 psi) BARS TO MATCH CHB HOR. BARS
3. CARRY VERTICAL BARS AT LEAST 600 mm ABOVE FLOOR LEVEL TO PROVIDE FOR SEE SCHEDULE OF
3. ALL REINFORCED CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH THE 16 Ø 320 320 320 SPLICES WHEN NECESSARY. STOP AT 50 mm BELOW BETWEEN TOP OF THE SLAB OR CONCRETE HOLLOW

400
20 Ø 600 600 600 SOLID BAND WHERE THE WALLS END. HORIZONTAL AND VERTICAL BARS SHALL BE BLOCK REINF.
ACI-318-95 BUILDING CODE, AND ALL STRUCTURAL STEEL WORK SHALL BE DONE SPLICE BY LAPPING A DISTANCE EQUAL TO 40 DIAMETER AND WIRED SURELY WITH
25 Ø 750 750 750
IN ACCORDANCE WITH AISC SPECIFICATIONS (LATEST EDITION) IN SO FAR AS THEY 820
NO. 16 G.I. WIRE PROVIDED THAT SPLICES IN ADJACENT BARS ARE STAGGERED AT CHB WALL FOR SIZE AND SPACING
28 Ø 820 820 LEAST 1520 mm ON CENTER. (SEE FIGURE 3) OF HOR. & VERT. BARS
DO NOT CONFLICT WITH THE LOCAL BUILDING CODE REQUIREMENTS. 32 Ø 950 950 950 SEE SCHEDULE OF
36 Ø 1050 1050 1050 1520 mm CONCRETE HOLLOW
4. ALL SLABS, BEAMS, GIRDERS AND OTHER STRUCTURAL ELEMENTS WHICH ARE NOT
Min. BLOCK REINF.
INDICATED, DETAILED, DESIGNATED OR INADVERTENTLY OMITTED BUT ARE NECESSARY 8. CLEAR CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS :
1.) CONCRETE CAST AGAINST EARTH - 75 mm
TO BE COORDINATED WITH ARCHITECTURAL AND OTHER ALLIED ENGINEERING PLANS
2.) CONCRETE EXPOSED TO EARTH 400 mm
(SPLICE SPACING) a) CORNER WALL CHB WALL

(SPLICE SPACING)
AS WELL AS TO COMPLETE THE STRUCTURAL WORKS IN ACCORDANCE WITH THE 20 mm TO 36 mm BARS - 50 mm
INTENT OF THE PLANS AND SPECIFICATIONS SHALL BE BROUGHT UP DURING PRE-BIDS/ 16 mm BARS AND SMALLER - 40 mm
3.) CONCRETE NOT EXPOSED TO EARTH OR WEATHER
MEETINGS/HEGOTIATIONS. IT IS UNDERSTOOD THAT THE CONTRACTOR HAS PROVIDED
AND INCLUDED ALL THESE ITEMS IN THEIR BID.
SLABS, WALLS, AND JOINTS
BEAMS AND COLUMNS
- 20 mm
- 40 mm CHB WALL
b) INTERSECTION WALL

1520 mm
COT. L-SHAPED DOWEL
BARS TO MATCH CHB HOR. BARS
B. NOTES ON CONCRETE MIXES AND PLACING FIGURE 3
FOR SIZE AND SPACING
OF HOR. & VERT. BARS
1. UNLESS OTHERWISE INDICATED IN PLANS OR NOTED IN THE SPECIFICATIONS THE D. NOTES ON FOUNDATION SEE SCHEDULE OF
CONCRETE HOLLOW

600 mm
MINIMUM 28-DAYS CYLINDER COMPRESSIVE STRENGTH OF CONCRETE fC SHALL BE AS BLOCK REINF.
1. FOOTING ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 1200 PSF (57.5 KPa)
FOLLOWS : AT A MINIMUM DEPTH OF 2.0 METERS FROM THE NATURAL GRADE LINE, CIONTRACTOR SHALL
FLOOR LEVEL C) END WALL
1.1 FOUNDATION 21 MPa (3000 psi) REPORT IN WRITING TO THE STRUCTURAL ENGINEER ON THE ACTUAL SOIL CONDITIONS UNCOVERED
1.2 RETAINING WALLS 21 MPa (3000 psi) AND CONFIRM ACTUAL BEARING CAPACITY OF SOIL BEFORE DEPOSITING CONCRETE.
400 400
1.3 PEDESTAL, COLUMNS & RC WALLS 21 MPa (3000 psi) DOWEL DOWEL
2. NO FOOTING SHALL REST ON FILL FOOTINGS FOR CHB WALLS AND OTHER MINOR STRUCTURES
1.3.1 FOUNDATION TO ROOF BEAM 21 MPa (3000 psi) SHALL BE EMBEDDED AT LEAST 750 mm FROM THE NATURAL GRADE LEVEL.
1.4 FLOOR SLABS, BEAMS & GIRDERS 21 MPa (3000 psi) 3. PROVIDE TEMPORARY REMOVAL OF WATER FROM ANY SOURCE DURING CONSTRUCTION DEWATERING
1.5 PARAPET WALLS AND OTHER STRUCTURAL ELEMENTS 21 MPa (3000 psi) SHALL BE CAREFULLY AND PROPERLY REFORMED TO AVOID DISTURBING THE FOUNDATIONS AND SLAB
d) INTERSECTING R.C. COLUMN & WALL
1.6 PARTITIONS, CURTAIN WALLS, BEDDED SLABS, SIDEWALKS, BEARING SURFACES.
CURB, GUTTER & OTHER STRUCTURAL ELEMENTS 17.0 MPa (2500 psi) 4. CONTRACTOR SHALL DESIGN, INSTALL AND MONITOR EXCAVATIONS RETENTION SYSTEMS, AS REQUIRED
1.7 LEAN CONCRETE 10.0 MPa (1500 psi) FOR PROTECTION OF ADJACENT PROPERTIES AND PROVIDE ALL MEASURES AND PRECAUTIONS NECESSARY FIGURE 5. TYPICAL CONNECTION DETAILS OF
2. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGRGATIO, RE-HANDLING
CONCRETE MASONRY UNITS AT
TO MINIMIZE SETTLEMENT AND PREVENT DAMAGE TO ADJACENT EXISTING OR NEW CONSTRUCTION.
COLUMN AND / OR WALLS
OR FLOWING, PLACING SHALL BE DONE PREFERABLY WITH BUGGIES, BUCKETS OR WHEEL 5. PREPARE CONDITIONS OF CONCRETE SUPPLY AND PLACEMENT OF THE COMPLETE FOUNDATION FOR THE
BARROWS. NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS FULL THICKNESS AS A CONTINUOUS MONOLITHIC CASTING. VERTICAL BARS BENT IN
40d
40d
A U-FORM LIKE STIRRUPS
TO BUGGIES, WHEEL BARROWS OR BUCKETS, IN WHICH CASE THEY SHALL NOT EXCEED SIX 6. DO NOT BACKFILL AGAINST BASEMENT WALLS UNTIL GROUND FLOOR SLABS HAVE BEEN PLACED AND THE
THOUSAND (6000 mm) IN AGREGATE LENGTH. CONCRETE HAS ATTAINED THE REQUIRED STRENGTH.
3. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS UNLESS 7. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL ELEVATOR DETAILS. REFER TO ARCHITECTURAL,
AUTHORIZED IN WRITING BY THE STRUCTURAL ENGINEER AND ONLY FOR USUAL CONDITIONS MECHANICAL, PLUMBING AND OTHER TRADES FOR SUBSOIL DRAINAGE SYSTEM, MACHINERY, ANCHORS AND
2-20 Ø t => 250 mm
WHERE VIBRATION IS EXTREMELY DIFFICULT TO ACCOMPLISH. OTHER EMBEDDED ITEMS, DEPRESSIONS, FINISHES, DOWELS FOR MASONRY WALLS, CURBS, ETC. 2-16 Ø t => 152 mm
8. SEE TYPICAL DETAIL OF LIMITING SLOPE OF ADJACENT FOOTING AT DIFFERENT ELEVATION. UP TO 228

C. NOTES ON REINFORCING STEEL BARS (REFER TO FIGURE 2)


2-12 Ø t < 127 mm

DOWEL
1. ALL REINFORCING STEEL BARS SHALL BE NEW BILLET, HOT ROLLED, WELDABLE DEFORMED BARS

400
CONFORMING TO THE SPECIFICATIOND OF PNS 49: 1986 (ASTM 615) WHOSE GRADE IS SHOWN ON 150 100

TABLE 1.
40d
TABLE - 1 40d 2-12 Ø TOP BARS 1-12 Ø
3-12 Ø VERT. BARS
WALL THICKNES

250
40d

250

250

250
GRADE BAR DIAMETER 10 Ø STIRRUPS @ W/ 100 TIES @ 150 O.C.
1
GRADE 414 (fy = 60 ksi) 28 mm, 32 mm 100 O.C. 1-12 Ø (2 SET) ALTERNATELY
2 2-12 Ø BOT. BARS PLACED
GRADE 275 (fy = 40 ksi) 25 mm TO 16 mm
GRADE 230 (fy = 33 ksi) 10 mm, 12 mm FIGURE 2. DETAIL OF LIMITING SLOPE OF ADJACENT FOOTINGS SECTION 150
100
2. THE SUPPLEMENTARY REQUIREMENTS OF WELDABLE DEFORMED REINFORCING BARS SHALL BE
AS FOLLOWS : E. NOTES ON SLAB - ON - GRADE TYPICAL DETAIL OF 100 & 150 CHB
2.1 THE MAXIMUM YIELD STRENGTH OF WELDABLE BARS = 540 MPa (FOR GRADE 4). CONCRETE POSTS @ 3,000 mm O.C.
2.2 THE TENSILE STRENGTH SHALL NOT BE LESS THAN 1.25 TIMES THE ACTUAL YIELD THE SOIL SUBGRADE AND FILL LAYERS BELOW ALL SLABS ON GRADE, PAVING AND PIT SLABS SHALL G. NOTES ON MASONRY WALLS SECTION
STRENGTH BE MECHANICALLY COMPACTED IN LAYERS TO A MINIMUM OF 95 PERCENT OF THE MODIFIED PROCTOR
1. ALL MATTERS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE APPLICABLE
3. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS UNLESS DENSITY, PER ASTM D1557.
AUTHORIZED IN WRITING BY THE STRUCTURAL ENGINEER AND ONLY FOR USUAL CONDITIONS STANDARDS AND SPECIFICATIONS OF THE NATIONAL CONCRETE MASONRY ASSOCIATION 2 S-1
WHERE VIBRATION IS EXTREMELY DIFFICULT TO ACCOMPLISH. ALL SLABS-ON-GRADE SHALL BE PROVIDED WITH A MINIMUM OF 100 mm THK. COMPACTED CLEAN AND UNIFORM BUILDING CODE.
4. ALL REINFORCING BARS SHALL BE CLEANED THOROUGHLY OF ALL LOOSE RUST, SOIL OR OTHER COARSE SAND BED. 2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 GRADE N.
MATERIAL IMMEDIATELY PRIOR TO PLACING CONCRETE. 3. MORTAR AND GROUT FOR ALL REINFORCED MASONRY SHALL CONFORM TO ASTM 270-
5. THE REQUIRED LENGTH OF LAP FOR TENSION SPLICES IS BASED ON THE DEVELOPMENT LENGTH, Ld, UNLESS OTHERWISE NOTED, ALL BEDDED SLABS SHALL BE REINFORCED WITH 10 mm BARS AT 250 mm TYPE M AND SHALL HAVE A MINIMUM 28 DAYS STANDARD CYLINDER COMPRESSIVE OF
SHOWN IN THE TABLE 2 AND TABLE 3 FOR RC BEAMS AND GIRDERS, RESPECTIVELY AND ON THE O.C. EACHWAY AT THE CENTER OF SLAB. 21 MPa (3000 PSI).
FOLLOWING CLASSIFICATIONS : 4. ALL MASONRY WALLS SHALL BE REINFORCED ACCORDING TO THE FOLLOWING SCHEDULE
TENSION SPLICES CLASSIFICATION SPLICE LENGTH PLACE CONCRETE FOR ALL SLABS-ON-GRADE IN CHECKERBOARD FASHION BETWEEN CONSTRUCTION OF CONCRETE HOLLOW BLOCK REINFORCEMENT UNLESS OTHERWISE INDICATED IN THE PLANS.
CLASS A 1.0 Ld JOINTS IN AREAS NOT TO EXCEED 300 SQ. METERS WITH A MINIMUM OF 24 HOURS BETWEEN ADJACENT 5. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY FILLED WITH 10 Ø STIRRUPS

CLASS B 1.3 Ld AREAS OF PLACEMENT, CONSTRUCTION JOINTS SHALL NOT BE FARTHER APART THAN 8.00 METERS IN CONCRETE GROUT.
ANY DIRECTION. ALL SLABS-ON-GRADE SHALL BE SAW CUT ON EACHGRID LINE AND MID BAY LINE (IN 6. FOR TYPICAL CONNECTION DETAILS ON MASONRY UNITS. REFER TO FIGURES 5, 6 & 7
TABLE - 2 DEVELOPMENT LENGTH, Ld, in TENSION 1-16 Ø BARS
RESPECTIVELY.
BOTH DIRECTION) WITHIN 24 HOURS AFTER CASTING.
BAR SIZE fc = 28.0 MPa (4000 psi) fc = 34.5 MPa (5000 psi) fc = 21 MPa (3000 psi)
(mm) CHB WALL
DOOR JAMB

16 Ø
TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS
390 300 390 300 360 275
F. NOTES OF CONCRETE WALLS TABLE - 6

20 Ø 650 500 580 450 540 425 SCHEDULE OF CONCRETE HOLLOW BLOCK REINFORCEMENT
1. ALL WALLS SHALL BE REINFORCED ACCORDING TO THE FOLLOWING SCHEDULE OF WALL OPENING
25 Ø 1010 780 910 700 800 650 BLOCK
REINFORCEMENT NOTE
28 Ø 1270 980 1140 870 1050 835 REINFORCEMENT UNLESS OTHERWISE INDICATED IN THE PLANS. (REFER TO TABLE-5) THICKNESS
(mm) HORIZONTAL VERTICAL POURED CONCRETE
TABLE - 5 SCHEDULE OF WALL REINFORCEMENT A. MINIMUM LAP SPLICES - 30Ø
6. TOP BARS ARE HORIZONTAL BARS WITH AT LEAST 300 mm OF CONCRETE CAST BELOW IT. 100 10 Ø at 600 O.C. 10 mm at 400 O.C. B. PROVIDE 1-180 VERTICAL BAR @
CORNERS, INTERSECTION, END OF 1-16 Ø VERT. BARS
WALL VERTICAL WALLS AND EACH SIDE OF OPENING. CHB WALL
REINFORCEMENT
TABLE - 3 DEVELOPMENT LENGTH, Ld, in TENSION FOR R.C.
THICKNESS
(mm) HORIZONTAL VERTICAL
REMARKS SECTION
150 12 Ø at 600 O.C. 12 mm at 400 O.C.
C. WHERE CHB WALLS ADJOINCOLUMNS,
RC BEAMS & WALLS DOWEL WITH THE
SAME SIZE AS VERTICAL OR HORIZONTAL
REINFORCEMENT SHALL BE PROVIDED.
SECTION
GIRDERS (PRISMATIC & NON-PRISMATIC) HORIZONTAL BAR AT CENTER D. LINTEL SHALL BEAR AT LEAST 18 INCHES
100 10 mm at 250 O.C. 10 mm at 300 O.C. VERTICAL BARS STAGGERED OUTSIDE (400 mm) ON EACH SIDE OF MASONRY
200 12 Ø at 600 O.C. 10 mm at 400 O.C. WALL OPENING.

BAR SIZE fc = 28 MPa fc = 35 MPa fc = 21 MPa 125 10 mm at 200 O.C. 10 mm at 250 O.C. DITTO E. PROVIDE POST AND LINTEL BEAM @ 3000 O.C.

(mm) TOP BARS OTHER BARS TOP BARS OTHER BARS TOP BARS OTHER BARS 150 12 mm at 288 O.C. 12 mm at 250 O.C. DITTO
(mm) (mm) (mm) (mm) (mm) (mm) 175 20 mm at 250 O.C.E.F. 12 mm at 200 O.C.E.F. DITTO
BOTH FACES HORIZONTAL
16 Ø 390 390 390 390 360 275 200 10 mm at 288 O.C.E.F. 10 mm at 250 O.C.E.F. SHALL BE OUTSIDE
20 Ø 580 580 580 580 540 425 225 12 mm at 200 O.C.E.F. 12 mm at 228 O.C.E.F. DITTO
25 Ø 1010 1010 910 910 800 650 250 12 mm at 250 O.C.E.F. 12 mm at 300 O.C.E.F. DITTO
28 Ø
32 Ø
1270
1660
1270
1660
1140
1480
1140
1480
1050
1380
835
1250
275
300
12 mm at 228 O.C.E.F.
12 mm at 200 O.C.E.F.
12 mm at 250 O.C.E.F.
12 mm at 250 O.C.E.F.
DITTO
DITTO ELEVATION
36 Ø 2570 2570 2300 2300 2200 2200 350 12 mm at 180 O.C.E.F. 12 mm at 200 O.C.E.F. DITTO
400 16 mm at 330 O.C.E.F. 16 mm at 355 O.C.E.F. DITTO
NOTE : FOR BUNDLE BARS (3 BUNDLE) MULTIPLY ABOVE TABLE BY 1.3

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C CONSTRUCTION NOTES LOCATION S 01
Contact No. : 09661374892
Email Add: mcmiguelengineeringservices@gmail.com CIVIL ENGINEER
REG. NO.: P.T.R. NO.:
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES 05
T.I.N. NO.:
SARANGANI PROVINCE
DATE: 03/30/2023
CONSTRUCTION NOTES
MINIMUM STAGGERED LEGEND :
SPACING WHEN WELDED PROVIDE 12 Ø
SPLICES OR MECHANICAL EXTRA TIES @ 100 O.C. Sj = 100 mm O.C.
BEAM REINFORCING BARS BOTH TOP AND TERMINATING IN A WALL SHALL EXTEND CONNECTOR ARE USED Sb = 100 mm O.C.
AT THE MOST 50 mm FROM THE FACE OF THE WALL AND SHALL TERMNATE IN A (SEE COLUMN SCHEDULE FOR TIES)
CLASS B
STANDARD 90°. (APPLICABLE ONLY FOR Sj AND Sh)
TENSION SPLICE
H = 150 mm O.C.
5. WHEN A BEAM CROSSES A GIRDERS REST BEAM BARS ON TOP OF THE GIRDER BARS- WHEN USED LOCATE LAP (USE 12 mm Ø TIES)
PROVIDE ADDITIONAL TIES AS SHOWN IN FIGURE 14 WHEN BEAMS OF DIFFERENT TOP SPLICE NEAR MID HEIGHT Lv = PART OF COLUMN BETYOND
OF COLUMN BUT NOT CONFINEMENT REGION
ELEVATIONS CROSS A GIRDER.
INDICES INDICES H. NOTES ON CONCRETE SLABS CLOSER THAN MAX. COL. Lo = CONFINEMENT REGION

Sh/2

Lo
DIMENSION FROM FACE

Sh
3 - 16 Ø EXTRA BARS 1 - 25 Ø L/4 LOCATION OF 2810 TO JOINT
1. ALL SLABS REINFORCEMENTS SHALL HAVE A MINIMUM CLEAR DISTANCE OF 20 mm
PIPE SLEEVE SHOULD

Ll
TOP BARS FROM THE BOTTOM AND FROM THE TOP OF SLABS.
BE WITHIN THIS REGION

Sj
MINIMUM STAGGERED = MAXIMUM COLUMN
2. UNLESS OTHERWISE DETAILED, FOR CONTINUOUS SLABS WITH THE MAIN SPACING WHEN WELDED

Sh/2
1
DIMENSION BUT

Lo
6 SPLICES OR MECHANICAL NOT LESS THAN
REINFORCEMENT RUNNING IN ONE DIRECTION, REINFORCING BARS SHALL BE BENT UP,
CONNECTOR ARE USED

Sh
ONE-SIXTH CLEAR
EXTENDED OR CUT AS FOLLOWS :

600 SW
HEIGHT OF COLUMN
OR 450

MIN

H
1
L1/4 L1/3 L2/3 L2/3 L3/3 2/3 L4
6
12 Ø HANGER TIES Sw = SPACING INDICATED
BOTTOM BARS

Lv
EACH TOP BARS ON COLUMN SCHEDULE

MAX
90 DEG HOOK
GIRDER
L1/6 L1/5 L2/5 L2/5 L2/5 L3/5 Sh = ONE-FOURTH OF THE
MIN
L2 L3 L4 MINIMUM COLUMN DIMENSION

40 mm
Sh/2

Lo
FIGURE 14. EXTRA TIES FOR UNLEVELLED BEAMS NOMINAL MAXIMUM SIZE
USE Ø 20 mm BARS FOR BEAM
WIDTH OF 250 Ø mm OR THICKER
EXTERIOR SPAN INTERIOR SPAN INTERIOR SPAN BUT NOT MORE THAN 100 mm

(TYPICAL FOR 150 & SMALLER DROP ONLY) 200 mm Ø OF PIPE SLEEVE

Sh
(EACH FACE) BEAM WIDTH OF FIGURE 8.
200 mm OR LESS (EACH FACE)
6. LONGITUDINAL REINFORCEMENT OF GIRDERS, BOTH TOP AND BOTTOM, TERMINATED IN A

Sh
COLUMN SHALL BE EXTENDED TO THE FAR FACE OF THE CONFINED CONCRETE CORE OF THE 3. IF SLABS ARE REINFORCED BOTHWAY, BARS ALONG THE SHORTER SPAN BE PLACED Sj = Sh
COLUM AND TERMINATED BY A STANDARD 90° HOOK. BELOW THOSE ALONG THE LONG SPAN AT THE CENTER OF THE SLAB AND BE PLACED (REFER TO ITEM F)
FIGURE 17. TYPICAL PIPE SLEEVE DETAIL
7. GENERALLY, NO LAP SPLICE SHALL BE PERMITTED ON BEAMS AND GIRDERS AT POINTS WHERE BUNDLED COLUMN REINF.

H/2
OVER THE LONGER SPAN BARS ON AREAS NEAR THE SUPPORTS. THE SPACING OF THE CONSISTING OF PLANTED 40 mm COVER TO
CRITICAL BENDING STRESSES OCCUR. IN ADDITION, FOR GIRDERS, NO LAP SPLICE SHALL BE 1 COL.TIES TYPICAL
2) ONE-HALF (1
BARS AT THE COLUMN STRIPS SHALL BE APPROXIMATELY ONE AND REINF. CUT-OFF BUNDLED
LOCATED WITHIN THE JOINTS OR WITHIN A DISTANCE EQUAL TO TWICE THE MEMEBER DEPTH BAR REINF. AS SHOWN
FROM THE FACE OF THE JOINT. TIMES THAT IN THE MIDDLE STRIPS BUT IN NO CASE GREATER THAN TWO AND ONE-HALF COLUMN VERTICAL
1 REINFORCEMENT
8. PROVIDE LAP SPLICES IN GIRDERS WITH HOOP REINFORCEMENT OVER THE LENGTH OF THE (2) TIMES THE SLAB THICKNESS OR 450mm.
2
LAPPED BARS SPACED NO FARTHER THAN ONE - FOURTH THE NOMINAL DEPTH, OR 100 mm. 4. TEMPERATURE BARS FOR SLABS SHALL BE GENERALLY PLACED NEAR THE FACE IN TYPICAL TIED COLUMN DETAIL OF REINFORCEMENTS
9. WELDED SPLICES AND MECHANICAL CONNECTIONS MAY BE USED FOR SPLICING BEAMS AND TENSION AND SHALL NOT BE LESS THAN 0.0025 B. (SEE TABLE 7) BARS DETAIL OF TIED COLUMN AT TOP
GIRDERS PROVIDED THAT NO MORE THAN ALTERNATE BARS IN EACH LAYER OF LONGITUDINAL 5. UNLESS OTHERWISENOTED, DROP SLABS SHALL BE PROVIDED WITH ADDITIONAL

H
REINFORCEMENT AND SPLICES AT A SECTION AND THE CENTER TO CENTER DISTANCE BETWEEN REINFORCEMENT AT THE LOCATION OF DROPS AS SHOWN IN FIGURE 9.
SPLICES OF ADJACENT BARS IS AT LEAST 600 mm MEASURED ALONG THE AXIS OF THE MEMBER. FIGURE 12. TYPICAL SLICE & OFFSET DETAIL OF COLUMN BARS
6. PROVIDE EXTRA REINFORCEMENT FOR CORNER SLAB (TWO ADJACENT DISCONTINUOUS

H/2
10. UNLESS OTHERWISE DETAILED, TYPICAL BAR CUTTING DETAILS ARE AS SHOWN IN FIGURES
EDGES) AS SHOWN BELOW AND AT ENDS CORNERS OF SHEAR WALL (SEE FIGURE 10).
15 & 16 AND 10 OF THE NOTES ON REINFORCING STEEL BARS ON SHEET - 1.
11. SEE MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR ALL TABLE - 7
SUSPENDED AND EMBEDDED PIPING, CONDUITS, DUCTWORKS, EQUIPMENTS, ETC. SCHEDULE OF MINIMUM SLAB REINFORCEMENT
12. PIPE AND DUCT SLEEVES SHALL BE LOCATED WITHIN THE REGION BOUNDED BY ONE-FOURTH SLAB THICKNESS
SECTION MINIMUM TEMPERATURE BARS
OF CLEAR SPAN LENGTH FROM THE SUPPORTS. (SEE FIGURE 18) (mm)
13. SHEAR REINFORCEMENT SHALL BE IN THE FORM OF HOOPS IN REGIONS WHERE CONFINEMENT 100 10 mm Ø at 279 mm O.C. STAGGERED SPLICES
IS REQUIRED, SINGLE AND TWO-PIECE HOOPS SHALL BE AS DETAILED IN FIGURE 19. FOR COLUMN BARS

PIPE SLEEVE 114 10 mm Ø at 241 mm O.C.


STAGGERED SPLICES
127 10 mm Ø at 216 mm O.C. FOR COLUMN BARS
INDICES INDICES INDICES INDICES
INTERIOR GIRDER SUPPORT

L1 L2 L3 10db 8db 138 10 mm Ø at 190 mm O.C.


EXTERIOR SPAN 1ST INTERIOR SPAN INTERIOR SPAN
EXTENSION EXTENSION FINISH FLOOR LEVEL FINISH FLOOR LEVEL
150 10 mm Ø at 177 mm O.C.
0.25 L1 600 0.33 L1 0.33 L2 600 0.33 L2 0.33 L3 0.33 L3
6 6 6
1 in 6 OFFSET 1 in 6 OFFSET
5-10 mm BARS AT MAXIMUM
10 mm ADDITIONAL 200 O.C. (BOT. BARS) MAXIMUM
DETAIL - A DETAIL - B DETAIL - C TIES AT 150 mm O.C.
h

h
4-10 mm CONT.
600 600 600 600 600 600 150 DROP OF SLAB

0.20 L1 0.20 L1 0.20 L1 0.20 L1 0.20 L1 0.20 L1


(MAX) (MAX) (MAX)
B
(MAX) (MAX) (MAX) BEAM

t
L/5 L/5
FIGURE 15. TYPICAL BAR DETAILS FOR BEAMS 300mm
A A C C CLEAR SPAN L FIGURE 11. TYPICAL SLICE & OFFSET DETAIL OF COLUMN BARS
5-10 mm BARS AT
200 O.C. (TOP BARS)

INDICES INDICES INDICES FIGURE 9. DROP SLAB FIGURE 10. CORNER SLAB
L1 L1
J. NOTES ON BEAMS AND GIRDERS
FIGURE 18. SINGLE AND TWO-PIECE HOOPS
7. SEE MECHANICAL, PLUMBING, ELECTRICAL, AND FIRE PROTECTION DRAWINGS FOR ALL 1. UNLESS OTHERWISE NOTED IN PLANS OR SPECIFICATIOPNS, CAMBER ALL BEAMS AT
SUSPENDED AND EMBEDDED PIPING CONDUITS DUCTWORK EQUIPMENT ETC. LEAST 8mm FOR EVERY 450 mm OF SPAN EXCEPT FOR CANTILEVERS FOR WHICH THE
0.33 L1 0.33 L1 0.33 L2 0.33 L2
8. UNLESS OTHERWISE NOTED, EMBEDDED CONDUITS SHALL BE RUN GENERALLY AT MID-BAY CAMBER SHALL BE AS NOTED IN THE PLANS OR AS ORDERED BY THE STRUCTURAL
AND PARALLEL CONDUITS SHALL BE AT THREE DIAMETERS ON CENTER. CONDUIT SIZE ENGINEERS BUT IN NO CASE LESS THAN 19 mm FOR EVERY 300 mm OF FREE SPAN.
NOT EXCEED 1 2. IF THERE ARE TWO OR MORE LAYERS OF LONGITIDUNAL REINFORCING BARS IN A
4 OF THE SLAB THICKNESS AND SHALL BE LOCATED AT MID THICKNESS OF
h

THE SLAB. BEAM OR GIRDER, USE SEPARATORS OF A SIZE NOT LESS THAN 25 mm BARS SPACED
CLASS B
LINTEL BEAM (TYP.) ABOUT 900 mm ON CENTER IN NO CASE SHALL THERE BE LESS THAN TWO (2)
LOCATE AT MID-HEIGHT
50 mm TYP.

2h 0.60 0.60 2h 2h 0.60


TENSION
SPLICE
0.60 2h
OF EVERY CHB WALL 2 - 12 mm HOR. STR. I. NOTES ON COLUMNS SEPARATORS BETWEEN LAYER OF BARS.
3. LONGITIDUNAL REINFORCING BARS SHALL BE PLACED SYMMETRICALLY ABOUT THE
OR SPACE A MAXIMUM BARS WITH 6 mm TIES
0.20 L1 0.20 L2 0.20 L2 0.20 L2
OF 3000 mm O.C. AT 300 mm O.C. 1. WHERE COLUMNS CHANGE IN SIZE, VERTICAL REINFORCEMENTS SHALL BE OFFSET AT VERTICAL CENTER LINE OF THE BEAM OR GIRDER SECTION WHERE POSSIBLE WITH
MAXIMUM MAXIMUM MAXIMUM 2 - 12 Ø STR. BARS UPPER LAYER BARS PLACED DIRECTLY ABOVE THOSE IN THE BOTTOM LAYER.
A SLOPE NOT MORE THAN 1 in. 6. PROVIDE TRANSVERSE REINFORCEMENT AS PER ITEM
4. MINIMUM CONCRETE PROJECTION OR REINFORCEMENT BARS OR SHAPES SHALL BE
300

NO SPLICE REGION OF NO SPLICE REGION OF NO SPLICE 10 Ø TIES @ 300 mm O.C. E BELOW FOR JOINTS WITH BAR OFFSET (AS SHOWN IN FIGURE 11.)
EXTERIOR SPAN INTERIOR SPAN BEAM BLOCK AT 2. LAP SPLICES, WHEN REQUIRED, ARE PERMITTED ONLY WIHTIN THE CENTER OF TEH COLUMN AS SHOWN IN FIGURE 13.
EXTERIOR COLUMN SUPPORT INTERIOR COLUMN SUPPORT 2 - 12 Ø STR. BARS EVERY FOURTH COURSE LENGTH AND SHALL BE PROPORTIONED AS TENSION SPLICES, IN NO CASE SHALL THE LAP
SPLICE BE LOCATED CLOSER THAN A DISTANCE EQUAL TO THE MAXIMUM COLUMN DIMENSION 10 Ø TIES AT 150 O.C. 3-10 Ø TOP BARS
FROM THE FACE OF THE BEAM-COLUMN JOINT, PROVIDE EXTRA TRANSVERSE REINFORCEMENT
OF THE SAME SIZE AND ARRANGEMENT INDICATED IN THE COLUMN SCHEDULE SPACED AT MOST
ONE-FOURTH THE MINIMUM COLUMN SECTION DIMENSION THROUGHOUT THE LENGTH OF THE
FIGURE 16. TYPICAL BAR DETAILS FOR PRISMATIC GIRDERS DETAIL OF BLOCK & LINTEL BEAM SPLICE OR 100 mm. 38 mm CLEAR MIN.
3. FOR ALL TIED COLUMNS, PROVIDE TRANSVERSE REINFORCEMENT OF THE SAME SIZE AND 25 mm CLEAR MIN. FOR BEAM OR 19 mm
CLEAR MIN. FOR JOIST 3-10 Ø BOT. BARS
ARRANGEMENT INDICATED IN THE COLUMN SECTION SCHEDULE AND SPACED NO GREATER THAN
ONE-QUARTER THE MINIMUM COLUMN SECTION DIMENSION NOR 100 m, OVER A DISTANCE FROM 25 mm SEPARATORS
EACH JOINT FACE OF NOT LESS THAN THE LARGER OF THE MAXIMUM COLUMN SECTION DIMENSION, EACH AT 900 mm O.C. 50 mm CLEAR (MIN. FOR STEEL SHAPE BEAMS)

OR ONE-SXITH OF THE CLEAR HEIGHT OF THE COLUMN OR 450 mm.


4. UNLESSS OTHERWISE DETAILED, TYPICAL BAR DETAILS FOR TIED COLUMNS ARE AS SHOWN IN a. REINFORCED CONCRETE b. STRUCTURAL SHAPE
FIGURE 12.

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C CONSTRUCTION NOTES LOCATION S 02
Contact No. : 09661374892
Email Add: mcmiguelengineeringservices@gmail.com CIVIL ENGINEER
REG. NO.: P.T.R. NO.:
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES 05
T.I.N. NO.:
SARANGANI PROVINCE
DATE: 03/30/2023
A B C D

WF WF WF
1 FC-1 FC FC FC

100MM THK. CONC. FLOORING


WP W/ 10MM DIA. RSB @ 400MM
F I R E W A L L

ON CENTER BOTH WAYS

WP

WF
A WF

WP

2 FC-1 FC FC FC
WF
WP
F I R E W A L L

WF WF
WP
WF
WP
WF WF WF
WF
WP

WF WF
3
WF WF

FC-1 FC FC FC

01 FOUNDATION PLAN
B S-1 S SCALE 1:100

BEAM DETAILS

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services FOUNDATION PLAN
MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C
BEAM SCHEDULE
FOOTING SCHEDULE LOCATION S 03
Contact No. : 09661374892
CIVIL ENGINEER BEAM DETAILS
Email Add: mcmiguelengineeringservices@gmail.com
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
COLUMN SCHEDULE
SARANGANI PROVINCE
05
T.I.N. NO.: DATE: 03/30/2023
4-12mm Ø main bars w/ 4-12mm Ø main bars w/
10mm Ø ties sp. 0.15m o.c 10mm Ø ties sp. 0.15m o.c
LINTEL BEAM LINTEL BEAM

100 MM THK. CHB 150 MM THK. CHB

FFL

12mm Ø RSB sp. @ 0.40m O.C, B.W 12mm Ø hor. bars sp.
@ 3rd Layerof CHB and 12mm
Ø vert. bars sp. @ 0.40m o.c

FFL n.g.l

3-12mm Ø Continuous
#10MM DIA. @ 5-50, 5-100, 5-150 REST @ 200 bars w/ 12mm Ø C-ties sp.
GRAVEL BASE @ 0.250m O.C

B1-T16-@220

EL. 0.000
WALL FOOTING-3
BOF GRAVEL BASE

GRAVEL FILL
WALL FOOTING-1

B1-T16-@220 10mm Ø bars sp.


@ 180mm Both Ways 4-12mm Ø main bars w/
10mm Ø ties sp. 0.15m o.c
LINTEL BEAM

B2-T16-@220 100 MM THK. CHB

12mm Ø hor. bars sp.


@ 3rd Layerof CHB and 12mm
Ø vert. bars sp. @ 0.40m o.c

25000

FFL

0 THK PCC

150 MM THK. CHB GRAVEL BASE

COLUMN FOOTING DET.


TYP. CONC. LEDGE DET.
WALL FOOTING-2
SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C
COLUMN FOOTING DETAIL
WALL FOOTING DETAIL LOCATION S 04
Contact No. : 09661374892
CIVIL ENGINEER CONCRETE LEDGE DETAIL
Email Add: mcmiguelengineeringservices@gmail.com
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
05
T.I.N. NO.: DATE: 03/30/2023
A B C D

2" x 4" x 1.5mm thk. C-Purlins sp. @ 0.80m o.c


1
TRUSS
RD

BRACING

BRACING
F I R E W A L L
2"x6"x2mm Bracing

BUILDING LINE
12mm dia. sag rod

TRUSS
2 RD

F I R E W A L L
1.5mm thk. plain sht. side flashing

BRACING

BRACING
2" x 4" x 1.5mm thk C-PURLINS
sp. @ 0.80m o.c
TRUSS
3 RD
2" x 6" x 3mm thk Channel Bar
FULL TRUSS
1.5mm thk. Rib Type ROOF FRAMING PLAN
Roof
COLUMN

COLUMN

COLUMN
COLUMN

GUTTER

TRUSS DETAILS
SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C
TRUSS DETAIL
LOCATION S 05
Contact No. : 09661374892 ROOF FRAMING PLAN
Email Add: mcmiguelengineeringservices@gmail.com CIVIL ENGINEER
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
05
T.I.N. NO.: DATE: 03/30/2023
L E G E N D
2.80 MARK SPECIFICATION

WATER
1.20 0.60 0.60 WC
CLOSET

LAV LAVATORY
10 mm Ø BARS SP@
.20M O.C. FLOOR
FD
DRAIN
75mm THK POURED
CONCRETE MANHOLE COVER CLEAN
CO
w/ 8mm Ø PULL BAR. 49.79 49.79
OUT

0.55
DS DOWNSPOUT
INLET
RISER

0.90
1.10

0.50
R
PIPE

CATCH
INLET MH MH MH CB
BASIN

0.55
VENT
4 " THK CHB VTR THRU
150mm Ø REINF ROOF
OUTLET
CONCRETE 150mm Ø REINF
CHECK
PIPE LINE CONCRETE PIPE LINE VALVE
10 mm Ø CV
OUTLET
DEF. BARS
GATE
P L A N 0.45 0.50 GV VALVE

S E C T I O N 0.30 0.20 M WATER


METER
1.50 0.40 0.40
100mm Ø PVC PIPE INLET
PLAN P PUMP

WATER
WATER SUPPLY TANK
2.80
TANK
CAP.1500 L
STAINLESS STEEL CYLINDRICAL WATER STORAGE TANK
BSTR SERIES 2000 LITERS CAPACITY BY BESTANK

02 CATCH BASIN DETAILS SANITARY LINE

P-1 P-1 SCALE 1:15 MTS 1.20 0.60 0.60 2" Ø PVC PIPE - FOR FIXTURES

0.10 COLD WATER LINE


25MM Ø PPR WATERLINE - BRANCHES/RISER
20MM Ø PPR WATERLINE - FIXTURES

MANHOLE MANHOLE MANHOLE

0.30
AIRSPACE AIRSPACE AIRSPACE

GENERAL NOTES AND SPECIFICATION : INLET OUTLET

1.40
1.20
ALL SANITARY INSTALLATION AS INDICATED HEREIN SHALL BE DONE IN ACCORDANCE TO DIGESTIVE CHAMBER LEACHING CHAMBER LEACHING CHAMBER

1.00
THE PROVISION OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES.

MATERIALS USED IN THE INSTALLATION SHALL BE OF APPROVED BRAND FREE FROM


ANY DEFECTS AND PASSED THE QUALITY SET FORTH BY THE BUREAU OF THE 0.05% SLOPE 0.05% SLOPE
0.05% SLOPE
PHILIPPINE STANDARDS.

ALL PLUMBING WORKS AND/OR INSTALLATION SHALL BE DONE UNDER THE


CLOSE SUPERVISION OF A DULY LICENSED SANITARY ENGINEER OR A MASTER PLUMBER. S E C T I O N
01 SEPTIC VAULT DETAILS
P-2 P-2 SCALE 1:30 MTS

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C
CATCH BASIN DETAILS
LOCATION P 01
Contact No. : 09661374892 SEPTIC VAULT DETAILS
Email Add: mcmiguelengineeringservices@gmail.com MASTER PLUMBER
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
04
T.I.N. NO.: DATE: 03/30/2023
FROM WATER TANK
WATER SOURCE

A B C GV

M
D A B C D
CV

1 1

2 2

WC
WC

4" Ø PvC PIPE S-1000


LAV

CO
VTR

LAV
WC
WC

3 3

01 WATER SUPPLY LAYOUT


A-2 A-2 SCALE 1:100

TO MAIN SEWER LINE

01 SEWER LINE LAYOUT


A-2 A-2 SCALE 1:100

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C
WATER SUPPLY LAYOUT
LOCATION P 02
Contact No. : 09661374892 SEWER LINE LAYOUT
Email Add: mcmiguelengineeringservices@gmail.com MASTER PLUMBER
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
04
T.I.N. NO.: DATE: 03/30/2023
NK
TA E
R RC
A TEOU
WR S

A B C D OM TE
FR WA
GV M
CV

1
3" Ø PvC PIPE S-1000
CB
RD
SINK SINK

6" Ø PvC PIPE S-1000


WC

V
LA
WC
V
LA

2 SINK

SINK
RD
CB
SIN
K

K
SIN

6" Ø PvC PIPE S-1000


4" Ø PvC PIPE S-1000

LAV
01 ISOMETRIC WATER SUPPLY LAYOUT
LAV
A-2 A-2 SCALE 1:100

3 3" Ø PvC PIPE S-1000 RD


CB

TO MAIN SEWER LINE VTR

01 DRAINAGE LINE LAYOUT


A-2 A-2 SCALE 1:100

WC
CO

WC

NE
LI
ER
W
SE
01 ISOMETRIC SEWER LINE LAYOUT M
AI
N
A-2 A-2 SCALE 1:100
TO

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C
DRAINAGE LINE LAYOUT
ISOMETRIC WATER SUPPLY LAYOUT LOCATION P 03
Contact No. : 09661374892
MASTER PLUMBER ISOMETRIC SEWER LINE LAYOUT
Email Add: mcmiguelengineeringservices@gmail.com
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
04
T.I.N. NO.: DATE: 03/30/2023
CB

RD

K
SIN
K
SIN

CB

RD
K
SIN
K
SIN

CB

RD

NE
LI
ER
W
SE
N
AI
M
LA
V
TO
V
LA

K
SIN
K
SIN

01 ISOMETRIC DRAINAGE LINE LAYOUT


A-2 A-2 SCALE 1:100

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C ISOMETRIC DRAINAGE LINE LAYOUT LOCATION P 04
Contact No. : 09661374892
Email Add: mcmiguelengineeringservices@gmail.com MASTER PLUMBER
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
04
T.I.N. NO.: DATE: 03/30/2023
GENERAL NOTES AND SPECIFICATION : EF EXHAUST FAN 6" LEGEND:
ALL ELECTRICAL INSTALLATION SHALL BE DONE IN ACCORDANCE WITH THE RULES AND REGULATION
OF THE IMPLEMENTING AGENCY AND THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE . EF EXHAUST FAN 12" 4" DOWNLIGHT w/ 18W CFL BULB
ALL MATERIALS AND EQUIPMENTS SHALL BE NEW AND OF THE APPROVED TYPE FOR
BOTH LOCATION AND PURPOSE. 4' X 8' X 9MM THK GYPSUM BOARD IN
CF1 RECESSED LED RECTANGULAR LIGHT
LATEX PAINT SATIN FINISH 36W 1200 X 300MM
ALL ELECTRICAL WIRING SHALL BE INSTALLED IN uPVC IF RUN EMBEDDED IN
CONCRETE, MASONRY BLOCKS. WIRING RUN BET. CEILING AND ABOVE ROOF AND BET. ROOF DOUBLE
GENERAL NOTES EMERGENCY LIGHT
WALL WOODEN PARTITIONS SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING. E.L

ALL ELECTRICAL WORKS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF ALL ARCHITECTURAL PLANS SHALL PREVAIL OVER ALL
A DULY LICENSED ELECTRICAL ENGINEER OR MASTER ELECTRICIAN. ENGINEERING PLANS WITH REGARDS TO DIMENSIONS,
ANY DISCREPANCIES FOUND HEREIN SHALL BE MH 500 X 500 MM MANHOLE
THE MINIMUM CONDUCTOR WIRE TO BE USED SHALL BE 2.0 SQ. MM AND 3.5 SQ MM. FOR LIGTHING OUTLET AND SMALL VERIFIED WITH THE ARCHITECT.
APPLIANCE LOAD CIRCUIT RESPECTIVELY.

A B C D A B C D

1 EF EF
1 C
HO

R
A
NGE H
O
RO
.D

S 4
S
S
S FE
R
S
EF EF 5
C
HO

EF 2 C
O
S S C
O
EF
C
E
O
L

C
HO
C
E
O
L
EF EF 1

C
O C
E
O
L

2 EF
2
C
O
5
EF
F I R E W A L L

C
O
3
1
PB PB
S LO
LO C
O C
O C
O
LO S
3 C
O C
O
LO S EF

2
4 C
E
O
L
EF
LO LO
S ACU 6
LO LO
LO S

3 3
S S
S

LO LO
LO

01 LIGHTING LAYOUT PLAN 01 POWER LAYOUT PLAN


A-2 A-2 SCALE 1:100 A-2 A-2 SCALE 1:100

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C
LIGHTING LAYOUT PLAN
LOCATION E 01
Contact No. : 09661374892 POWER LAYOUT PLAN
Email Add: mcmiguelengineeringservices@gmail.com PROFESSIONAL ELECTRICAL ENGINEER
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
03
T.I.N. NO.: DATE: 03/30/2023
NOTES & SPECIFICATIONS PANEL BOARD SHALL BE FLUSH-TYPE & MUST BE INSTALLED LEGEND
1500 mm ABOVE FINISHED FLOOR LINE
MARK DESCRIPTION
ALL ELECTRICAL WORKS & INSTALLATION TO BE UNDERTAKEN
HEREIN SHALL CONFORM WITH THE LATEST EDITION OF THE TUMBLER SWITCHES & CONVENIENCE OUTLETS SHALL BE FLUSH-TYPE LIGHT OUTLET
LO
PHILIPPINE ELECTRICAL CODE, THE NATIONAL ELECTRICAL & MUST BE MOUNTED 1300 mm AND 300 mm ABOVE FINISHED FLOOR LINE,
CODE, RULES & EDUCATIONS OF THE INFORCING AUTHORITY RESPECTIVELY.
UNLESS OTHERWISE SPECIFIED, THE SMALLEST WIRE & PIPE
TO BE USED SHALL BE 3.5 sq. mm & 20mm Ø,RESPECTIVELY. ALL ELECTRICAL MATERIALS & DEVICES TO BE USED HEREIN MUST FLOOD LIGHT
BE BRAND NEW APPROVED TYPE FOR LOCATION & PURPOSE. FL

GARDEN LIGHT
THE SERVICE ENTRANCE SHALL BE SINGLE-PHASE, TWO-WIRE GL

230 VOLTS, 60 CYCLES PER SECOND SYSTEM. ALL WORKS AND INSTALLATION SHALL BE DONE OR LAID UNDER CLOSE CHANDELIER
CHL
SUPERVISION OF A DULY LICENSED ELECTRICAL ENGINEER. 28 WATTS, T5
THE CONDUIT RUN IN THE PLAN ARE SCHEMATIC, ACTUAL T5

RUN SHALL BE DETERMINED IN THE FIELD AND SHALL BE (PVC) PIPE T TRACK LIGHT

USE = 15 KVA DISTRIBUTION


EMERGENCY LIGHT OUTLET
SCHEDULE OF LOADS: TRANSFORMER
OIL EMMERSED, DOUBLE TOGGLE SWITCH ( NOTE: LETTERS
S
BUSHING, 7620/230V, 1Ø, DENOTES NUMBER OF GANGS)

10KAIC, % Z = 2%
220 Vac S3w 3WAY SWITCH ( WITH DIMMER)
LPPB-CH -(LIGHTING POWER PANEL BOARD) Source
CKT.NO. LOAD DESCRIPTION NO. OUTLET VOLTS WATTS PHASE AMPERE CB RATING SIZE OF WIRE SIZE OF CONDUCTOR LENGTH VD % VD CONVENIENCE OUTLET
LOAD C
O
L.O. C.O. AT POLE SQ.MM. THHN MM. DIAMETER
(M)
1 L.O 11 220 1100 5.00 15 2P 2 - 2.0 20 uPvC 18 1.037 0.4712 2-22.0mm² THW CU. WIRE COUNTER HEIGHT
2 L.O 9 220 900 4.09 15 2P 2 - 2.0 20 uPvC 18 0.967 0.439 C
HO CONVENIENCE OUTLET
INSIDE 32MM Ø RSC PIPE
3 L.O 10 220 1000 4.54 15 2P 2 - 2.0 20 uPvC 18 0.76 0.345 WEATHER PROOF SPECIAL
4 L.O 7 220 700 3.18 15 2P 2 - 2.0 20 uPvC 18 0.483 0.219
125 A
WP OUTLET
5 L.O 6 220 600 2.72 15 2P 2 - 2.0 20 uPvC 18 0.898 0.408
2-8.0mm² THW CU. WIRE
6 Convenience Outlet 5 220 900 4.09 20 2P 2 - 3.5 20 uPvC 18 0.403 0.183 AIR CONDITIONING OUTLET
7 Convenience Outlet 6 220 1080 4.90 20 2P 2 - 3.5 20 uPvC 18 0.564 0.256
INSIDE 20MM Ø RSC PIPE ACU
8 Convenience Outlet 7 220 1260 5.72 20 2P 2 - 3.5 20 uPvC 18
75 A WASHING MACHINE OUTLET
9 Range 1 220 1500 6.81 20 2P 2 - 5.5 20 uPvC 18 0.402 0.183 WM
10 Ref. 1 220 1000 4.54 20 2P 2 - 5.5 20 uPvC 18 0.268 0.122
11 ACU 1 220 2300 10.45 20 2P 2 - 5.5 20 uPvC 18 0.402 0.183 PANEL BOARD
12 SPARE 220 20 2P
15 A 15 A PB
PB-00
Total Connected Load 12,340 56.04 100 2P 2 - 22.0 38 uPvC C1 C2 CIRCUIT HOME RUN
00
15 A 15 A
CIRCUIT LINE
C3 C4
Computation: 15 A 15 A ACU AIR CONDITION UNIT
IT 12,340 x 80% DF
= 44.87 A C5
220 C6
USE = 2 - 22.0mm² THHN COPPER WIRE 20 A 20 A EF EXHAUST FAN
1 - 8.0 TW COPPER WIRE
USE = 100 A ACB 250 VOLTS C7 C8
IN = 50mm Ø RSC PIPE WH WATER HEATER TANK
20 A 20 A
C9 C10 P WATER HEATER PUMP

20 A SPARE
M KILOWATT METER
C11 C12
TELEPHONE OUTLET
T

CABLE TV OUTLET
CATV

GROUND-FAULT CIRCUIT
G
F
CI INTERRUPTER

E
C
B ENCLOSED CIRCUIT BREAKER

RISER DIAGRAM

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C
NOTES & SPECIFICATION
SCHEDULE OF LOADS LOCATION E 02
Contact No. : 09661374892
PROFESSIONAL ELECTRICAL ENGINEER RISER DIAGRAM
Email Add: mcmiguelengineeringservices@gmail.com
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
03
T.I.N. NO.: DATE: 03/30/2023
C1: C8: MAIN CONDUCTOR AND PROTECTION
Z 2.0mm² = ( 3.1 + j 0.058 )(18)
Z 3.5mm² = ( 2.0 + j 0.068 )(18) I T = 44.87 A
305
305
= 0.118 + j 0.00401 USE = 2 - 22.0mm² THW COPPER WIRE
= 0.183 + j 0.00342
= 0.118 < 1.947 1 - 8.0 THW COPPER WIRE
= 0.183 < 1.072 USE = 100 A ACB 220 VOLTS
VD = 4.90 (0.118) = 0.5782 V
VD = 5.0 (0.183) = 0.915 V IN = 50mm Ø RSC PIPE
% VD = 0.5782 V / 220 V x 100% = 0.263 %
% VD = 0.915 V / 220 V x 100% = 0.416 %

C2: C7: TRANSFORMER REQUIREMENTS: USE = 15 KVA


Z 2.0mm² = ( 3.1 + j 0.058 )(18)
305
Z 3.5mm² = ( 2.0 + j 0.068 )(18)
305
KVA = V (I)
1000
VS DISTRIBUTION
TRANSFORMER
= 0.118 + j 0.00401 KVA = 220V(56.04 A) 220V, % Z = 2%
= 0.183 + j 0.00342
= 0.118 < 1.947 1000
= 0.183 < 1.072
VD = 5.72 (0.118) = 0.675 V = 12.33 KVA
VD = 4.09 (0.183) = 0.75 V
% VD = 0.675 V / 220 V x 100% = 0.307 % USE = 15 KVA DISTRIBUTION TRANSFORMER OIL
% VD = 0.75 V / 220 V x 100% = 0.340 %
EMMERSED, DOUBLE
C3: C9: BUSHING, 7620/220V, 1Ø, 10KAIC, % Z = 2%

Z 2.0mm² = ( 3.1 + j 0.058 )(18) Z 5.5mm² = ( 1.2 + j 0.050 )(18)


305 2-22.0mm² THW CU. WIRE
305
= 0.183 + j 0.00342 = 0.071 + j 0.00295 MAIN FEEDER VOLTAGE DROP CALCULATION:
= 0.183 < 1.072 = 0.071 < 2.386
VD = 4.54 (0.183) = 0.831 V VD = 6.81 (0.071) = 0.484 V ZL = 0.0335 < 8.802
% VD = 0.831 V / 220 V x 100% = 0.378 % % VD = 0.484 V / 220 V x 100% = 0.220 % D = 20.0 m ; L = 32.6 m 20.0 M

C4:
Z 2.0mm² = ( 3.1 + j 0.058 )(18)
C10: Z 22.0mm² @ 75° CI

305 Z 5.5mm² = ( 1.2 + j 0.050 )(18) Z 22.0mm² = ( 0.31 + j 0.048 )(32.6)


= 0.183 + j 0.00342 305 305
= 0.183 < 1.072 = 0.071 + j 0.00295 = 0.0335 + j 0.00609
VD = 3.18 (0.183) = 0.582 V = 0.071 < 2.386 = 0.0335 < 8.802
% VD = 0.582 V / 220 V x 100% = 0.265 % VD = 4.54 (0.071) = 0.322V
% VD = 0.322 V / 220 V x 100% = 0.147 %
C5: TRANSFORMER FULL LOAD CURRENT:
Z 2.0mm² = ( 3.1 + j 0.058 )(18)
C11: IT = 56.04 A
305 Z 5.5mm² = ( 1.2 + j 0.050 )(18) VD = IZ
= 0.183 + j 0.00342
= 0.183 < 1.072
305
= 0.071 + j 0.00295 VD = 56.04 (0.0335) = 1.90 V VR
VD = 2.72 (0.183) = 0.498 V = 0.071 < 2.386 % VD = 1.90 V / 220 V x 100% = 0.85 %

% VD = 0.498 V / 220 V x 100% = 0.226 % VD = 10.45 (0.071) = 0.742V VR = 220V - 1.90V = 218.10 V IF
% VD = 0.742 V / 220 V x 100% = 0.337 %
C6:
FAULT CURRENT CALCULATION :
Z 3.5mm² = ( 2.0 + j 0.068 )(18)
305 Z TOTAL = TRANSF. % Z + %VD
= 0.118 + j 0.00401
= 2 % + 0.85 % = 2.85 %
= 0.118 < 1.947
IF = 220 V / 0.0285
VD = 4.10 (0.118) = 0.4838 V 1000
% VD = 0.4838 V / 220 V x 100% = 0.220 %
IF = 7.720 KVA

SHEET CONTENT PROJECT TITLE OWNER REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 SHEET NO.

PROPOSED ONE-STOREY BAKERY


MCMiguel Engineering Services MANUFACTURING BUILDING
-CONTRACTOR'S -DESIGNER'S -ENGINEER'S
Address: Blk. 15, Lot 55, Lumina Homes, Conel Road, San Isidro, G.S.C VOLTAGE DROP COMPUTATION LOCATION E 03
Contact No. : 09661374892
Email Add: mcmiguelengineeringservices@gmail.com PROFESSIONAL ELECTRICAL ENGINEER
NEW BOHOL, MARIBULAN, ALABEL, RECHEL T. GONZALES
REG. NO.: P.T.R. NO.:
SARANGANI PROVINCE
03
T.I.N. NO.: DATE: 03/30/2023

You might also like