CYLINDER HEAD QG

Inspection (Cont’d)
CAMSHAFT END PLAY NJEM0019S06
1. Install camshaft in cylinder head. Refer to EM-45.
2. Measure camshaft end play.
Camshaft end play:
Standard
0.115 - 0.188 mm (0.0045 - 0.0074 in)
Limit
0.20 mm (0.0079 in)
3. If limit is exceeded, replace camshaft and remeasure end play.
SEM918F + If limit is still exceeded after replacing camshaft, replace
cylinder head.

CAMSHAFT SPROCKET RUNOUT NJEM0019S07


1. Install sprocket on camshaft.
2. Measure camshaft sprocket runout.
Runout (Total indicator reading):
Limit 0.15 mm (0.0059 in)
3. If it exceeds the limit, replace camshaft sprocket.

SEM919F

VALVE GUIDE CLEARANCE NJEM0019S08


1. Measure valve deflection as shown in figure. (Valve and valve
guide wear the most in this direction.)
Valve deflection limit (Dial gauge reading):
Intake & Exhaust
0.2 mm (0.008 in)

SEM345D

2. If it exceeds the limit, check valve to valve guide clearance.


a. Measure valve stem diameter and valve guide inner diameter.
b. Calculate valve to valve guide clearance.
Valve to valve guide clearance = valve guide inner diam-
eter − valve stem diameter.
c. Check that clearance is within specification.