36 Dlplus

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Introducing the Introducing the

36DL PLUS 36DL PLUS


The New Wave in Ultrasonic Thickness Gaging The New Wave in Ultrasonic Thickness Gaging

Standard Measurement Mode: Manual Gain Adjust: File Structures:


Time interval from a precision delay after Allows the gain to be manually increased or Data can be stored in 8 standard or custom
the excitation pulse to the first echo. decreased in 1dB steps. application-specific file structures.
Thru-Paint Echo-to-Echo Mode: Automatic Probe Recognition: Reports:
Time interval between two successive The 36DL PLUS automatically adjusts internal On-gage reporting of: Summary with
backwall echoes for elimination of paint or parameters and corrects for V-path. statistics, Min/Max with locations, and
coating using dual or single element Zero Compensation Mode: File Comparison. On-screen comparison
transducers. Manual Mode or Automatic Mode. of current and previous readings.
Provides zero offset compensation for
Thickness Measurement Range: temperature variations in the transducer Interface Program:
0.020 - 20 inches (0.5 - 500mm). material, and for transducer wear. 16-bit or 32-bit Windows Interface Program
Material Velocity Range: Alarm Mode: compatible with Windows 3.x, 95 and NT.
0.0300 - 0.5511 inch/µS. Programmable Hi-Low Alarm setpoints with
(0.762-13.999mm/µS). audible and visual indicators. DISPLAY
Battery: Display:
6V Rechargeable NiCad battery pack, INTERNAL DATALOGGER Liquid Crystal Display with Electroluminescent
or field-replaceable alkaline AA batteries. Datalogger and RS-232: backlight. Contrast keypad adjustable.
Display area 4.0 x 3.39 inch (102 x 86mm).
Fast-Charger: The 36DL PLUS identifies, stores, recalls,
Two-hour Fast Charger with universal voltage. clears, and transmits thickness readings, Backlight:
waveform images, and gage setup Backlit electroluminescent display with
Receiver Bandwidth: information via the RS-232 Serial Port. Power Save feature.
1-15MHz (-3dB). Baud Rate, Word Length, Stop Bits, and Zoom Mode:
Resolution: Parity are adjustable from the keypad.
Expands the horizontal span of the waveform
0.001" (0.01mm) STANDARD. Maximum # of Stored Values: to the minimum range associated with each
0.01" (0.1mm) LOW. Selectable from keypad. Up to 95,000 thickness readings and/or 4000 transducer and automatically centers the
Operating Temperature: waveforms, or combination of both. measured echo.
-10°C to +50°C (-5°to 112°F). Stored Data Documentation: Freeze Mode:
Keypad: Each saved thickness reading or waveform is Measurement adjustments on frozen
fully documented with measurement status A-Scan for post-processing of information.
Sealed color-coded keypad with tactile and flags and a setup number which identifies
audible feedback. Rectification:
parameters such as velocity, transducer gain, etc.
Size: RF, half wave positive or negative, and full wave.
Location Codes:
9.375 x 5.45 x 1.5" (238 x 138 x 38mm). Waveform Display Range Control:
8-character file name plus 16-character
Weight: alphanumeric location code input. Multiple The horizontal span of the waveform is set
Comments per location. at selected intervals depending on transducer
2.1 lbs. (0.95Kg). frequency.
Case: Extended Blanking:
Water-resistant, gasketed Lexan case An adjustable blanking zone prevents selected
with sealed connectors. echoes or noise from being measured.
Min/Max Mode:
Works in conjunction with FAST Mode for NDT Division
rapid location of minimum or maximum 221 Crescent Street
thickness reading and associated waveform. Waltham, MA 02154 USA
MinFinder: ISO 9001 Certified
(617) 899-2719
Display visually assists in locating the held Reg. No. Q1 95 11 24107
Minimum reading.
Toll Free USA (800) 225-8330
Fax (617) 899-1552
Auto Sensitivity Gain Optimization:
e-mail: ndt@panametrics.com *All specifications are subject to change without notice.
Allows the normal measurement sensitivity @ Panametrics, Inc. 5/97. Windows is a registered trademark
to be automatically increased or decreased of Microsoft Corporation. Lexan is a registered trademark
depending on the transducer and material http:// www.panametrics.com of General Electric Corporation.

noise level.
The Panametrics 36DL PLUS... Step up to the next level
innovative, powerful, easy-to-use of ultrasonic thickness gaging!
With the introduction of the new 36DL PLUS you will have a thickness gage Powerful Standard New, Flexible File-Based
that increases your inspection performance and makes data management an Measurement Features Datalogger
easy and flexible task. ❖ Thru-Paint Echo-to-Echo Measurements ❖ Up to 95,000 thickness readings and/or
with dual and single element transducers 4000 waveforms, all fully documented,
❖ Wide Thickness Range from 0.020 to 20 can be stored, recalled, and transmitted
The 36DL PLUS is the result of Panametrics' many years of accumulated knowledge inches (0.5 to 500mm) ❖ Data can be stored in 8 standard or
and experience designing ultrasonic testing equipment. We carefully listened to ❖ Fast Minimum Capture Mode custom application-specific file structures
suggestions and comments from the thousands of customers who bought the ❖ Exclusive MinFinder bar visually assists ❖ 8-character file name plus 16-character

26DL PLUS, a gage considered the industry standard since its introduction in 1991. in locating the held Minimum thickness alphanumeric location code input
❖ RF, half wave positive or negative, and ❖ On-gage reporting of: Summary with
Several ideas were implemented with the goal of making the 36DL PLUS even better statistics, Min/Max with locations, and
full wave rectification
than its highly regarded predecessor. See for yourself why the 36DL PLUS Ultrasonic ❖ Measurement adjustments on frozen
File Comparison
Thickness Gage is today's most powerful, versatile and easy-to-use tool for measuring A-Scan for post-processing of information ❖ Multiple Comments per location

remaining wall thickness. This new PLUS can step up the productivity of anyone ❖ On-screen comparison of current versus
All-in-One, High-Resolution previous readings
who needs accurate, handheld inspection of pipes, tanks,
or other critical areas subject to corrosion or erosion. Backlit Display
❖ Both A-Scan waveform and thickness New WinPLUS 16-bit or 32-bit
reading in one large Liquid Crystal Display Windows® Interface Program
❖ Unsurpassed A-Scan resolution ensures ❖ Fully compatible, bi-directional data transfer
precise waveform trace between 26DL PLUS and 36DL PLUS
Familiar user operation
❖ Large, bold thickness readout ❖ Import/export of 26DL PLUS format
Anyone familiar with the 26DL PLUS will data files
be comfortable using the new 36DL PLUS. ❖ Bright LCD with adjustable contrast for
various lighting conditions ❖ Project-based environment for better
Both units have a similar operational look
❖ Electroluminescent backlight with Power
file management
and feel, and it will take just a short time
to learn the 36DL PLUS's many new and Save feature ❖ Advanced ODBC database compatibility

enhanced features. ❖ Selectable Filled or Outline waveform trace ❖ Enhanced OLE features
❖ Compatible with Windows 3.x, 95, and NT ®
Data compatibility Intuitive Operation with
Historical inspection data, including data On-Screen Messages Superior, Field-rugged Design
from the 26DL Plus, can be transferred from ❖ Instant text messages guide users when ❖ Ergonomic designed case with hand
your computer to the 36DL Plus, and vica changing parameters strap provides well-balanced,
versa. Current readings and historical data one-hand operation
❖ On-screen programmable clock with date
can be compared on-screen. ❖ Water-resistant, gasketed case with
and time stamp
❖ Color-coded groupings of strategically
sealed connectors keeps out moisture,
Transducer compatibility located keys dust, and couplant
The 36DL PLUS is compatible with the ❖ Durable Lexan ®‚ case withstands the
❖ Direct-access keypad minimizes
same transducers that you have used with time-consuming slewing rigors of heavy field use
all other Panametrics' 26 series gages. ❖ Operator interchangeable Nicad
In addition, Automatic Probe recognition or AA alkaline batteries
provides maximum performance with ❖ Two-hour Fast Charger with
each selected transducer. universal voltage

You might also like