Professional Documents
Culture Documents
Timber Joist
Timber Joist
Timber Joist
0.0
mm 1550
A 1 B
1.056
1.1
mm 1550
A 1 B
0.0
-2.725
-2.7
mm 1550
A 1 B
Applied loading
Beam loads
D Permanent self weight of beam 1
SD Permanent full UDL 0.638 kN/m
Live Live full UDL 1.800 kN/m
Load combinations
Load combination 1 Support A Permanent 1.20
Live 1.50
Span 1 Permanent 1.20
Live 1.50
Support B Permanent 1.20
Live 1.50
Analysis results
Maximum moment; Mmax = 1.056 kNm; Mmin = 0.000 kNm
Design moment; M = max(abs(Mmax),abs(Mmin)) = 1.056 kNm
Project Job Ref.
ENGINEERED DESIGNS FNPF MERCURY HOUSE - FLOOR ASSESSMENT 4781
Section Sheet no./rev.
FLOOR JOIST 2
Calc. by Date Chk'd by Date App'd by Date
SAP 9/20/2022 VK
45
50
Modification factors
Duration of load factor for strength - Table 2.3; k1 = 0.80
Moisture condition factor - cl.2.4.2.3; k4 = 1.00
Temperature factor - cl.2.4.3; k6 = 1.00
Length and position of bearing factor - Table 2.6; k7 = 1.00
Strength sharing factor - Table 2.7; k9 = 1.00
Temporary design action ratio; r = 1.00
Project Job Ref.
ENGINEERED DESIGNS FNPF MERCURY HOUSE - FLOOR ASSESSMENT 4781
Section Sheet no./rev.
FLOOR JOIST 3
Calc. by Date Chk'd by Date App'd by Date
SAP 9/20/2022 VK