PT PETROLAB SERVICES

Independent Laboratory OIL ANALYSIS REPORT


Pisangan Lama III no.28 Pisangan Timur - Jakarta Timur 13230 No. 03095/NEO/UO/II/23
Telp +62 21 2968 8694; Fax +62 21 2968 8693; petrolab@cbn.net.id;www.petrolab.co.id

Company Name : PT. PENTA PRIMA SEJATI Unit Model : GENIE Z80/60 Oil Matrix : GEN HDO 32
To Customer : PT. AVER ASIA INDONESIA Unit Number : 6017 U Serial Number :
Address : Jl. Raya TSS B1 B/81 I, Jakarta Component : NOT GIVEN Make/Brand :
Location : NOT GIVEN Component Matrix : HD M Request Order :

Test Detail Overall Analysis Result:


Lab Number OJ02997/UO/23
Sampling Date 2023-03-17
Received Date 2023-03-24
Report Date 2023-03-30
Hours on Oil 8426
Hours on Unit 7926
Lube Oil Name RANDO HD 32 Attention
Oil Change Attention Urgent
Physical Test Unit Method Test Value Min | Max Min | Max
Kin Visc at 40oC (*) cSt ASTM D445-21 32.83 28.8 | 35.2 27.2 | 38.4
o
Kin Visc at 100 C (*) cSt ASTM D445-21 | |
ASTM D2270-10
Visccosity Index -
(Reapproved 2016)
TBN mg KOH/g ASTM D2896-21
TAN mg KOH/g ASTM D974-21 0.37 0.8 1
Contaminant
Natrium (Na) ppm ASTM D5185-18 1 50 70
Silicon (Si) ppm ASTM D5185-18 1 30 45
Fuel Dilution *) %v ASTM E2412-10 0
Water Content *) %v ASTM E2412-10 0 0.1 0.2
Glycol *) %v ASTM E2412-10 0 2 3
Wear Metal
Iron (Fe) ppm ASTM D5185-18 4 20 30
Copper (Cu) ppm ASTM D5185-18 4 30 50
Alumunium (Al) ppm ASTM D5185-18 <1 15 20
Chromium (Cr) ppm ASTM D5185-18 1 10 15
Nickel (Ni) ppm ASTM D5185-18 <1
Tin (Sn) ppm ASTM D5185-18 <1
Lead (Pb) ppm ASTM D5185-18 1 10 15
PQ Index *) - ASTM D8184-18e1 1 16 26
FTIR Warning Limit
Soot Abs/01mm ASTM E2412-10 (R18) < 0.02
Oxidation Abs/01mm ASTM E2412-10 (R18) 0.24 / B 0.2 0.4
Nitration Abs/01mm ASTM E2412-10 (R18) < 0.02 0.2 0.4
Sulfation Abs/01mm ASTM E2412-10 (R18) 0.1 0.2 0.4

Source of Abnormality
Oksidasi di atas normal, kemungkinan akibat aging atau new oil reference pada uji FTIR tidak sesuai.
Action to be Taken
Hindari overheat/overload. Mohon mengirimkan sample new oil agar hasil FTIR lebih akurat. Resampling 1.000 jam berikutnya.
Manager Teknis

Endriastuti

(*) Berdasarkan ISO VG Grade dan SAE Viscocity Grade


*) Tidak Termasuk Ruang Lingkup Akreditasi
Catatan : Data analisa hanya berlaku untuk sample yang diuji di laboratorium PT. Petrolab Services
Pengaduan tidak dilayani setelah 30 hari dari tanggal report di terbitkan
Report tidak boleh digandakan tanpa persetujuan tertulis dari laboratorium.
Notes : N=Normal, B=Attention, C=Urgent, D=Severe
Page 1 of 1 RK/7.8/02