Professional Documents
Culture Documents
SUBMERSIBLE SEWAGE PUMP - (KSB) - Rev.0
SUBMERSIBLE SEWAGE PUMP - (KSB) - Rev.0
al S
Subm
mitt
tal
Prog
gram:
: 07
Proj
ject:
: Shuura Hotel
H l Cen
ntral
l #1
Pack
kage:
: Conncret
te Pa
ackag
ge
RSG-CN-TMP-0007
7
Prog
gram:
: XX
Proj
ject:
: XXXXX
Pack
kage:
:
Mate
erial
Docu
ument Numbe
er
Revi
ision
Revi
ision Date
`
Disc
ciplin
ne
Subm
mittin
ng
Cont
tracto
or
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.00,
R Oct. 01,2022 Page | 1
CLASSSIFICATION: INTERNAL & SSENSITIVE
MEP - Vendor List
TRS-QL-FRM-0008
Code
Description Supplier
Reference
Fosters Insulation KIMMCO Kooltherm
PHE-126 Vapour Barriers Childers (USA) Isover Belgium
(USA) (Kuwait) Insulation UK
Mason
Carpenter and Hira Walraven
PHE-127 Hangers and Supports for Piping and Equipment Industries Hilti (USA) Weicco (India) Index (EU) Solver (Germany) Fischer
Paterson (UK) (UAE/Netherland)
(USA)
AEROFOAM
PHE-129 Acoustic Lagging ARMAFLEX (KSA) K-Flex (Italy) Kinetics (UK) KIMMCO (Kuwait)
(KSA)
J R Smith
PHE-130 Floor Drain Hepworth (UK) Zurn (USA) Wade (UK) ACO (UAE) Saudi Cast (KSA) Terrain (Polypipe)
(USA)
J R Smith
PHE-131 Floor Clean Out Hepworth (UK) Zurn (USA) Wade (UK) ACO (UAE) Saudi Cast (KSA) Terrain (Polypipe)
(USA)
J R Smith
PHE-132 Balcony Drain Hepworth (UK) Zurn (USA) Wade (UK) ACO (UAE) Saudi Cast (KSA) Terrain (Polypipe)
(USA)
J R Smith
PHE-133 Shower Drain Hepworth (UK) Zurn (USA) Wade (UK) ACO (UAE) Saudi Cast (KSA) Terrain (Polypipe)
(USA)
J R Smith
PHE-134 Parking Drain Hepworth (UK) Zurn (USA) Wade (UK) ACO (UAE) Saudi Cast (KSA)
(USA)
J R Smith
PHE-135 Ablution Channel Grating Hepworth (UK) Zurn (USA) Wade (UK) ACO (UAE) Saudi Cast (KSA)
(USA)
J R Smith
PHE-136 Channel Drain Hepworth (UK) Zurn (USA) Wade (UK) ACO (UAE) Saudi Cast (KSA)
(USA)
J R Smith
PHE-137 Funnel Drain Hepworth (UK) Zurn (USA) Wade (UK) ACO (UAE) Saudi Cast (KSA)
(USA)
XYLEM
Grundfos EBARA
PHE-138 Sewage Sump Pumps (Soil) Lowara & KSB SPP (UK) Armstrong (USA)
(Denmark) (Italy)
Flygt (Italy)
J R Smith
PHE-139 Grease Interceptor Zurn (USA) Watts (USA) Wade (UK) Kessel (Germany) ACO (UAE) MIFAB (USA)
(USA)
J R Smith
PHE-140 Sand Interceptor Zurn (USA) Watts (USA) Wade (UK) ACO (UAE)
(USA)
Crane Fluid
PHE-146 Hose Bibs Hattersley (UK) Nibco (USA) Pegler (UK) Watts (UK) Tyne
Systems (UK)
XYLEM
Grundfos EBARA Lowara &
PHE-147 Domestic Water Pumps Sets KSB SPP (UK) Armstrong (USA)
(Denmark) (Italy) Flygt
(Italy)
McDonnell Miller Davis Controls Magnetrol Invensys
PHE-148 Water Level Indicator Gems (USA)
USA (Canada) (UK) (USA)/Schneider
Crane Fluid
PHE-149 Float Valves Hattersley (UK) Nibco (USA) Pegler (UK) Tyne
Systems (UK)
Pentair Purelab
PHE-152 Water Features Filtration Fittings & Accessories Marlo (USA)
(USA/EU) (Canada)
Peerless Pentair
PHE-153 Water Features Circulation Pumps KSB Purelab (Canada)
(Canada) (USA/EU)
METITO
PHE-154 Automatic Chemical Treatment System VEOLIA (UK) Culligan (UAE) Water bird (UAE) Corodex (KSA)
(KSA)
Megatron
PHE-155 Disinfection System Jentech (UK) Xylem Corodex (KSA) Hanovia (UK)
(USA)
30
MEP - Vendor List (TRS-QL-FRM-0008)
Revision 21, Date 01 Dec. 2022
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
Material
M S
SUBMER
RSIBLE
E SEWA
AGE PU
UMP
Document
D Number R
R07-HC
C1C20-
-SBG-M
MAT-PL
L-
Revision
R 0
00
Revision
R Date 1
11/04/
/2023
Disciplin
D ne M
Mechan
nical
Submittin
S ng Contr
ractor M
MEAC
Revision H
History
Rev. Da
ate Dettails of Revisio
on Prepared By Reviewe
ed By Approve
ed By
00 11/04
4/2023 Issu
ued for Approval Shadi Masri
M Md. Khurram Ashraf Nader A.. Moniem Omer
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 2
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
TABLE O
OF CONT
TENTS
1 PRODU
UCT INFOR
RMATION ................................................................................................................ 8
2 STATEMENT OF COMPLIANC
C CE .......................................................................................................... 9
3 SCOPE
E OF WORKS
S .......................................................................................................................... 10
4 SPECIF
FICATION COMPLIANC
C CE CHECK LIST
L .................................................................................. 11
5 TECHN
NICAL DATA
A SHEET................................................................................................................ 30
6 SAMPL
LE (LIST / PHOTOS)
P .............................................................................................................. 48
7 REPORTS ................................................................................................................................ 49
TEST R
8 LEED C
COMPLIANC
CE & CERTIIFICATES ............................................................................................ 57
9 COUNT
TRY OF ORIIGIN – CON
NFIRMATIO
ON LETTER ..................
. ...................................................... 58
10 PRODU
UCT AUTHO
ORITY APPR
ROVAL ................................................................................................. 60
11 DRAFT TY ......................................................................................................................... 70
T WARRANT
OUS PROJE
13 PREVIO VALS .................................................................................................. 74
ECT APPROV
E LICENSE............................................................................................................................... 81
14 TRADE
FACTURER CONFIRMA
15 MANUF ATION OF THE
T LOCAL AGENT ............................................................ 83
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 3
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
Com
mpalince
Sl
Des
scription Not Not Re
emarks
No Provided
Prrovided App
plicable
1 State
ement of Complaince ☒ ☐ ☐
2 Scop
pe of Works ☒ ☐ ☐
3 Speccification Comp
plaince Check List ☒ ☐ ☐
4 Tech
hnical Data She
eet ☒ ☐ ☐
5 Test Reports ☒ ☐ ☐
6 LEED
D Complaince ☐ ☐ ☒
7 Coun
ntry of Origin ☒ ☐ ☐
8 Authority Appovalss ☒ ☐ ☐
9 Draftt Warranty ☒ ☐ ☐
10 Reco
ommended Spa
are Parts ☐ ☐ ☒
11 Trade
e Licence ☒ ☐ ☐
12 Proje
ect Refrences ☒ ☐ ☐
13 Previious revision comment
c trackker ☐ ☐ ☒
Above checklilist is the minim
mum requirem
ment, subject to th Employer and
t review by the a or Assitan
nts.
P
Prepared By Reviw
wed By A
Approved By
Name S
Shadi Masri Md. Khu
uram Ashraf N
Nader A. Mon
niem Omer
Contractor
Designation S
Sales Manag
ger QA/QC Manager
M
R
Representativ
ve
Sign
Date 1
11/04/2023
3 11/04/2
2023 11/04/2023
Stamp
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 4
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
PREVIO
P OUS RE
EVISIO
ON CO
OMMEN
NTS AN
ND CON
NTRAC
CTOR
RESPO
R NSE
Progr
ram: XX
Proje
ect: XXXX
X
Packa
age:
Mater
rial
Docum
ment Number
N r
Revis
sion
Revis
sion Date
D
Disci
ipline
e
Submi
itting
g
Contr
ractor
r
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 5
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
For Revision
R 0 sub
bmission, note
e “ NOT APPLIC
CABLE” }
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 6
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
1 PR
RODUCT INFORM
MATION
[ Following ta
able to be populated as miniimum}
Sl
Desscription Value Rem
marks
No
Name: KSB
04 Man
nufacturer
A
Address: USA
Name: MEAC
05 Sup
pplier
Address: KSA
A
06 Cou
untry of Origin
n USA
07 RSP
P vendor List Compliance
C Yes or No
09 Req
quired Date on
n Site TBD
Man
nufacturing du
uration
10 TBD
(Ex- Factory)
Ship
pment duratio
on
11 TBD
(Ex-factory to Sitte)
12 Exp
pected Arrival on Site TBD
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.00.
R Oct. 01, 20
022 Page | 7
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
2 STA
ATEMENT
T OF COMPLIAN
NCE
[ Following statement of co
ompliance tem
mplate can be used
u by the Su
upplier / Manu
ufacturer and must be produced in their
Company lette er head signed
d and stamped by the Authorized represe
entative}
Stattement of Com
mpliance
Date: 06/04/2
2023
Program: 07
a Hotel Centra
Project: Shura al #1
Package: Con
ncrete Package
e
Subject: State
ement of Compliance for Ma
aterial “Subme
ersible Sewage
e Pumps”
horized represe
I, as the Auth entative from the Supplier/ Manufacturerr, acknowledge
e and certify the
t material su
ubmission covvered
under this doccument [Submmersible Sewage Pumps] is produced in accordance
a witth following.
☒ Co
ompliance witth Contract Sp
pecifications
☒ Co
ompliance witth Contract Drrawings
☐ Co
ompliance with Contractual Requirementss
☐ Co
ompliance with Authority Re
equirements
☐ Co
ompliance with LEED requirrements
Nam
me: Shadi Masrri
Signa
ature:
Stam
mp:
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 8
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
3 SCO
OPE OF WORKS
W
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 9
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
4 SPE
ECIFICAT
TION CO
OMPLIAN
NCE CHE
ECK LIST
T
[ Following sh
hall be part of this section
1.. Line by line
e compliance with
w specificattion requireme
ents
2.. Append the
e relevant spe
ecification secttions
3.. Justification
n by the Manu
ufacturer for any
a variance
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 10
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
Mott MacDonald | x 3
x
Sump Pumps
x | x | 19 April 2020
TABLE OF CONTENTS
SECTION 221429 SUMP PUMPS 2
PART 1 GENERAL 2
1.1 RELATED DOCUMENTS 2
1.2 SUMMARY 2
1.3 ACTION SUBMITTALS 2
1.4 CLOSEOUT SUBMITTALS 2
1.5 QUALITY ASSURANCE 2
1.6 DELIVERY, STORAGE, AND HANDLING 2
PART 2 PRODUCTS 2
2.1 SUBMERSIBLE SUMP PUMPS 2
PART 3 EXECUTION 4
3.1 EARTHWORK 4
3.2 EXAMINATION 4
3.3 FIELD QUALITY CONTROL 4
3.4 STARTUP SERVICE 5
3.5 ADJUSTING 5
3.6 DEMONSTRATION 5
PART 1 GENERAL
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
B. Related Section:
1. Section 221329 "Sanitary Sewerage Pumps" for effluent and sewage pumps.
A. Product Data: For each type of product indicated. Include construction details, material
descriptions, dimensions of individual components and profiles and Include rated
capacities, operating characteristics, electrical characteristics, and furnished specialties
and accessories.
A. Operation and Maintenance Data: For pumps and controls, to include in operation and
maintenance manuals.
A. Retain shipping flange protective covers and protective coatings during storage.
PART 2 PRODUCTS
2.1 SUBMERSIBLE SUMP PUMPS
A. The unit shall be provided complete with anti-corrosion coated receiver tank with two
submersible sewage pumps, one duty and one standby, all necessary controls including
rotary-contact level switches, control gear with mains operated alarm and volt-free contacts
for remote failure indicators. Control gear shall be arranged for automatic changeover
after each pumping sequence.
C. The pump design must allow an unrestricted free passage of fibres and particles up to 80
mm to pass through the pump.
D. A connection between the pump housing and the stator housing must be without the use of
bolts to ensure easy inspection and service of impeller and shaft seal.
E. The unit shall be damp and flood-proof suitable for placing in an unventilated area.
F. Each pump shall be suitable for pumping surface wastewater containing small solids and
be capable of operation with fluids at temperatures of up to 50 degree C and complete with
an automatic thermal cut-out to protect the pump at higher temperatures.
H. The pump must have a built-in thermal switch in motor windings along with a moisture
switch.
I. Motors shall be protected against damage from dry operation, over frequent starting and
jammed impeller.
1. Insulation class F (155°C)
2. Enclosure class IP68
3. The motor must be cooled without the use of any cooling liquid (liquid-less cooling).
This applies to pumps in both dry and submerged installations.
4. Power cable featuring wires for thermal motor protection in the motor windings.
J. Operation and control of duplicate drainage pump installations shall be as follows: -
1. The selected duty pump shall start on the liquid level rising to operate the 'Start Duty
Pump' control and shall stop on a fall in the liquid level operating the 'off' control.
2. The standby pump shall automatically operate in unison with the duty pump if the
liquid level rises to operate the 'Start Standby' control.
3. In the event of failure of the duty pump the standby pump shall operate when the liquid
level rises to operate the 'Start Standby' control.
4. At the end of each pumping cycle, the duty and standby pumps shall automatically
change over, i.e., the standby pump would become the lead duty pump for the
following pumping cycle and vice-versa.
5. The alarm system shall operate if the liquid level rises to operate the 'High Water
Alarm' control.
K. The pump set shall be complete with a local wall mounted starter/control/indication panel
comprising: -
M. Pump construction
i. Pump housing, motor top and Impeller should be Cast Iron. Impeller to be Vortex or
closed tube type
ii. The Vortex impeller in the pump must be self-cleaning with winglets for improved
hydraulic efficiency.
iii. Double mechanical cartridge shaft seal allowing rotation in either direction.
iv. Stainless steel cable plug filled with cast in sealing barrier to prevent moisture from
penetrating into the motor via the cable core M.M. Motors shall be provided in
accordance with the requirements of the 'Electrical Equipment' Section of this
Specification N.N. Voltage, phases and frequency of the electrical supply to each
pump are stated in the Technical Schedules.
PART 3 EXECUTION
3.1 EARTHWORK
3.2 EXAMINATION
A. Examine roughing-in for plumbing piping to verify actual locations of storm drainage piping
connections before sump pump installation.
D. Pumps and controls will be considered defective if they do not pass tests and inspections.
3.6 DEMONSTRATION
END OF SECTION
Specifications
Remark
Standard Supplier/
No. Clause
Specifications Reference Specifications Contractor
220576 PART1 GENERAL
1.1 RELATEDDOCUMENTS
DrawingsandgeneralprovisionsoftheContract,
includingGeneralandSupplementary
A - Noted
ConditionsandDivision01SpecificationSections,
applytothisSection.
1.2 SUMMARY
A SectionIncludes
1 Submersiblesumppumps.
B RelatedSection:
Section221329"SanitarySeweragePumps"for
1 - -
effluentandsewagepumps.
1.3 ACTIONSUBMITTALS
ProductData:Foreachtypeofproductindicated.
Includeconstructiondetails,materialdescriptions,
dimensionsofindividualcomponentsandprofiles
A andIncluderatedcapacities,operating - Comply
characteristics,electricalcharacteristics,and
furnishedspecialties
andaccessories.
WiringDiagrams:Forpower,signal,andcontrol
B - Comply
wiring.
1.4 CLOSEOUTSUBMITTALS
OperationandMaintenanceData:Forpumpsand
A controls,toincludeinoperationand
maintenancemanuals.
1.5 QUALITYASSURANCE
ElectricalComponents,Devices,andAccessories:
ListedandlabelledasdefinedinNFPA70,bya
A
qualifiedtestingagency,andmarkedforintended
locationandapplication.
ULCompliance:ComplywithUL778formotor
B
operatedwaterpumps.
1.6 DELIVERY,STORAGE,ANDHANDLING
MaterialCompliancewithProjectSpecifications
SubmittalTitle: SUBMERSIBLESEWAGEPUMP Revision 0
B Protectbearingsandcouplingsagainstdamage. - Comply
Complywithpumpmanufacturer'swrittenrigging
C - Comply
instructionsforhandling.
PART2 PRODUCTS
2.1 SUBMERSIBLESUMPPUMPS
Theunitshallbeprovidedcompletewithanti
corrosioncoatedreceivertankwithtwo
submersiblesewagepumps,onedutyandone Duplex submersible pumps (1 duty + 1
standby) with control panel in accordance
standby,allnecessarycontrolsincluding
with KSB standards including volt free
A rotarycontactlevelswitches,controlgearwith Comply tankiscontractorscope
contacts, float switches and changeover of
mainsoperatedalarmandvoltfreecontacts
sequence.
forremotefailureindicators.Controlgearshallbe (refer to wiring diagram for details)
arrangedforautomaticchangeover
aftereachpumpingsequence.
Thepumpmusthaveabuiltinthermalswitchin moisturesensoris
The pump has a built-in thermal switch in Comply as
H motorwindingsalongwithamoisture applicableforlarger
motor windings noted
switch. pumpswithhigherflow
Mainincomingsupplyelectricalisolatorinterlocked Comply as
i Main disconnect breaker
withpaneldoor. noted
M Pumpconstruction
Pumphousing,motortopandImpellershouldbe
i vortex impller Comply
CastIron.ImpellertobeVortexorclosedtubetype
MaterialCompliancewithProjectSpecifications
SubmittalTitle: SUBMERSIBLESEWAGEPUMP Revision 0
Stainlesssteelcableplugfilledwithcastinsealing
barriertopreventmoisturefrompenetratinginto
themotorviathecablecoreM.M.Motorsshallbe
Rubber-sheathed cable H07RN8-F 3x1²,
providedinaccordancewiththerequirementsof
iv which is Absolutely watertight. Comply
the'ElectricalEquipment'Sectionofthis
60Hz/1Ph/220V
SpecificationN.N.Voltage,phasesandfrequencyof
theelectricalsupplytoeachpumparestatedinthe
TechnicalSchedules.
PART3 EXECUTION
3.1 EARTHWORK
ExcavationandfillingarespecifiedinSection
A - Noted
312000"EarthMoving."
3.2 EXAMINATION
Examineroughinginforplumbingpipingtoverify
A actuallocationsofstormdrainagepiping - Comply
connectionsbeforesumppumpinstallation.
3.3 FIELDQUALITYCONTROL
Manufacturer'sFieldService:Engageafactory
authorizedservicerepresentativetoinspect,test,
A - Comply
andadjustcomponents,assemblies,andequipment
installations,includingconnections.
B Performtestsandinspections.
MaterialCompliancewithProjectSpecifications
SubmittalTitle: SUBMERSIBLESEWAGEPUMP Revision 0
C TestsandInspections:
1 Performeachvisualandmechanicalinspection. - Comply
LeakTest:Afterinstallation,chargesystemandtest
2 forleaks.Repairleaksandretest - Comply
untilnoleaksexist.
OperationalTest:Afterelectricalcircuitryhasbeen
3 energized,startunitstoconfirmproper - Comply
motorrotationandunitoperation.
Testandadjustcontrolsandsafeties.Replace
4 damagedandmalfunctioningcontrolsand - Comply
equipment.
Pumpsandcontrolswillbeconsidereddefectiveif
D - Comply
theydonotpasstestsandinspections.
E Preparetestandinspectionreports. - Comply
3.4 STARTUPSERVICE
Engageafactoryauthorizedservicerepresentative
A - Comply
toperformstartupservice.
Completeinstallationandstartupchecksaccording
1 - Comply
tomanufacturer'swritteninstructions.
3.5 ADJUSTING
Adjustpumpstofunctionsmoothlyandlubricateas
A - Comply
recommendedbymanufacturer.
B Adjustcontrolsetpoints. - Comply
MaterialCompliancewithProjectSpecifications
SubmittalTitle: SUBMERSIBLESEWAGEPUMP Revision 0
Engageafactoryauthorizedservicerepresentative
totrainOwner'smaintenance
A - Comply
personneltoadjust,operate,andmaintaincontrols
andpumps.
ENDOFSECTION
General Notes
1. All dimensions are in millimeters unless otherwise stated.
MM Response 06/03/2023:
This is an Early Draft of IFC package
1000 1400
1000
400
N0 06/03/2023 ISSUED FOR CONSTRUCTION TN
Rev. Date Reason For Issue Chk
CONSTRUCTION DOCUMENTS
Key Plan HW1
HC2
HW2
HC3
HW3
Program 4
Undergoing
Coordination
HC1
Makkah
HW4
N HE1
K&A Scope
Legend
1000
2070
AOR/EOR
1000
Design Consultant
Festival Tower
Dubai Festival City
Dubai, UAE
300
T +971 (0)4 206 9111
250
dubai@mottmac.com www.mottmac.com
Executive Architect/ AOR
Licence number - 1010348048
Signature/Design Architect
Client
Project
SHURA
PROGRAM 07
HOTEL CENTRAL 01
Drawing Title
AS TN FS
Project No Issue Date Scale at ISO A0
1000 1400
1000
400
00 15/05/2022 REVISED 100% DESIGN DEVELOPMENT TN
Rev. Date Reason For Issue Chk
HC2
HW2
HC3
HW3
Program 4
Undergoing
Coordination
HC1
Makkah
HW4
N HE1
K&A Scope
Legend
1000
2070
AOR/EOR
1000
Design Consultant
Festival Tower
Dubai Festival City
Dubai, UAE
300
T +971 (0)4 206 9111
250
dubai@mottmac.com www.mottmac.com
Executive Architect/ AOR
Licence number - 1010348048
Signature/Design Architect
Client
Project
SHURA
PROGRAM 07
HOTEL CENTRAL 01
Drawing Title
AS TN FS
Project No Issue Date Scale at ISO A0
5 TEC
CHNICAL
L DATA SHEET
S
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 11
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
NOTE: Actual Pump Dimensions and PIT Size shall be incorporated in the
upcoming shop drawing.
PART 3
System Summary
Electro-Mechanical Department
Waste Water Applications
System Summary
Pump Data
Installation Conditions
Pump Materials
Electrical Motor
Power Rating : 1.1 KW Synchronous Speed : 3600 RPM
Frequency : 60Hz Protection Degree : IP 68
Voltage 220V/3Ph 380V/3Ph 400V/3Ph 460V/3Ph 220V/1Ph
Pumps System
Control Panel
Notes
A
Control panel details are no more applicable
Datasheet
Electro-Mechanical Department
Compact data sheet
18
Driver, accessories
16 Motor speed 3500 rpm
Frequency 60 Hz
Rated voltage 230 V
14 Rated input P1 1.50 kW
Rated power P2 1.10 kW
Rated current 8.2 A
12
Cable length 10.00 m
Total developed head
10
Installation parts
Installation type Stationary with guide wire
8
Scope of supply Pump with installation parts
Installation depth 4.50 m
Material concept G
6
Installation part kit 39021023
ident-number
[m]
Duckfoot bend
4 Duckfoot bend size (DN2 / 1
DN3)
ø110.0
Size / Material DN 50/Grey cast iron
2 EN-GJL-250
0 1 [l/s] 2 3 4 5 6 7 8 9 Mounting type Composite anchor bolts
Flow
Claw Straight
Claw
Design Size DN 50
Design Close-coupled submersible Ident-number 39021016
Lifting chain / -rope Chain
Discharge nominal dia. DN 50
Material CrNiMo steel 1.4404
Shaft seal Single acting mechanical seal
Length / Max. load 5.00 m / 160 kg
Impeller type Free flow (vortex) impeller (F)
Ident-number 39024058
Impeller diameter Free 110.0 mm
passage size 45 mm
Materials G
Pump casing (101) Cast iron EN-GJL-200
Shaft (210) Chrome steel 1.4021+QT800
Impeller (230) Cast iron EN-GJL-200
Operating data
Requested flow rate 3.000 l/s
Requested developed head 7.00 m
Pumped medium Wastewater, municipal
untreated
Pumped medium details Not containing chemical and
mechanical substances which
affect the materials
Actual flow rate 3.879 l/s
Actual developed head 11.70 m
Operating pressure (for 1.72 bar.g
indicated duty conditions)
Design Single system 1 x 100 %
Installation plan
60 85
ø 10
50
15
20 12
12
79
128 148
1)
200 120
138 105
36 DN1 130
ø 10 60
ISO 7005 DN50 PN10-PN16
125
436 DIN 2501 DN50 PN10-PN16
ANSI 150 LBS 2"
400
125
12 12
120
98 80 100
270
185
100
1) Lowest switch-off point for automatic operation
Motor Connections
Motor manufacturer KSB Discharge nominal size DN2 DN 50 / Drawing
Motor size 1,1 Nominal size DN3 DN 50 / ASME
Motor power 1.10 kW Rated pressure disch. PN 6
Number of poles 2
Speed of rotation 3500 rpm
Weight net
Pump 23 kg
Total 23 kg
Connect pipes without stress or strain!
Our technology. Your success.
Pumps Valves Service
n n
Ama-Porter –
Submersible motor pump
Applications:
■■ umping all types of
P
waste water
■■ Disposal of sludges and
solids-laden fluids
More information:
www.ksb.com/products
Your contact:
Ama-Porter – Submersible motor pump
2 Safe connection
Plug-type connector, polarized to prevent incorrect
4
insertion.
2
3 Service-friendly
right down to details: wetted bolts made of stainless steel.
Easy to dismantle, even after years of operation.
5 Trouble-free operation
Clogging by coarse particles is prevented by
2539.024/03-EN / 07.14 / © KSB Aktiengesellschaft 2014 · Subject to technical modification without prior notice
5
■■ large passage (free-flow impeller “F”)
■■ by cutter with high mechanical resistance for waste
Suggested Suggested
water (cutter “S”) Ama-Porter installation Ama-Porter installation
incl. high water alarm with LevelControl Basic 2
14
12
10 Technical data
Ama-Porter Ama-Porter S
8
Capacity Up to 40 m3/h (11 l/s) Up to 17 m3/h (4.7 l/s)
6
Discharge head 16 m 21 m
4 503
502 1.5 kW with three-phase asynchronous motor
501 Motor
2 603 1.1 kW max. with single-phase a.c. motor
500 602
601
0 Temperature Up to +40 °C (+70 °C for short periods)
0 10 20 30 40 Q (m3/h)
0 2 4 6 8 10 12 Q (l/s) Automation options: LevelControl Basic 2
KSB Aktiengesellschaft
Johann-Klein-Straße 9
67227 Frankenthal (Germany)
www.ksb.com
PART 3
Wiring Diagram
Electro-Mechanical Department
Building Services Water & Wastewater
KSB�_.I
2nd Industrial City Salaheddin Road
PO Box56368 PO Box56368
Riyadh 11554, KSA Riyadh 11476, KSA
Tel.:(+96611)2652081 Tel.:(+96611)2277060
Fax: (+96611)2651972 Fax: (+96611)4734789
KSB Pumps Arabia Ltd. web: www.ksb.com
Client / Customer:
Project / Reference:
Sheet Contents:
(l(SB16]
DUPLEX SUBMERSIBLE PUMPS SET
I
ONE DUTY & ONE STANDBY
56 6
8
Riyadh11554,KSA
PO '" 3 2 x 1 .1 KW / 220V / 1 PH / 60HZ
Tel.:{+96611)26520 1
8
Fax: (+96611)2651972
KSB Pumps Arabia Ltd. web: www.ksb.com DOL STARTING METHOD
FOR APPROVAL STANDARD EQUIPMENT TYPE: IP54
j
Sales Order: Scale (A3) NTS Date Sheet No:
C9.c.
___ Drawn by SHB 28NOV19
E
Production Order: Checked by DHB 28NOV19
Approved by BSG 28NOV19 SHT. 01
CADFile: SP2-220DL-001.1 OKW + BMS Rev.: 00
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
6 SAM
MPLE (LIIST / PH
HOTOS)
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 12
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
7 TES
ST REPORTS
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 13
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
E
PL
M
SA
E
PL
M
SA
E
PL
M
SA
E
PL
M
SA
Certificate
Standard ISO 9001:2015
Certificate Registr. No. 01 100 187121/092
Organization:
2022-07-22
TÜV Rheinland Cert GmbH
Am Grauen Stein · 51105 Köln
www.tuv.com
10 EU Declaration of Conformity
10 EU Declaration of Conformity
Ama-Porter
Serial number range: S2001-S2452
▪ is in conformity with the provisions of the following Directives as amended from time to time:
– Pump set: 2006/42/EC Machinery Directive
– Electrical components8): 2011/65/EU Restriction of the use of certain hazardous substances in electrical and
electronic equipment (RoHS)
– 2014/30/EU: Electromagnetic Compatibility (EMC)
The manufacturer also declares that
▪ the following harmonised international standards have been applied:
– ISO 12100
– EN 809
– EN 60034-1, EN 60034-5/A1
– EN 60335-1/A1, EN 60335-2-41
Person authorised to compile the technical file:
Hugues Roland
Head of Design/Engineering
KSB S.A.S.
128, rue Carnot,
59320 Sequedin (France)
The EU Declaration of Conformity was issued in/on:
Frankenthal, 1 January 2020
Thomas Heng
Head of Product Development Series Pumps
KSB SE & Co. KGaA
Johann-Klein-Straße 9
67227 Frankenthal
8) Where applicable
52 of 56 Ama-Porter
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
8 LEED COMP
PLIANCE
E & CERT
TIFICAT
TES
N/A
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 14
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
9 COU
UNTRY OF
O ORIG
GIN – CO
ONFIRMA
ATION LETTER
L
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 15
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
10 PRO
ODUCT AUTHOR
A RITY APP
PROVAL
[ Following ce
ertificates / ap
pproval evidence to be proviide as applicab
ble
1.. GOSI (General Organizattion for Social Insurance) Certificate
2.. Saudization
n Certificate
3.. ZAKAT & Tax
T Certificate
4.. VAT Registtration Certificcate
5.. Saudi Conttractors Authority (SCA) Mem
mbership
6.. SAGIA (Sau
udi Arabian Ge
eneral Investm
ment Authorities) Certificate
e
7.. Civil Defense Approval, *if
* required
8.. Electricity & Water Autho
ority Approval, *if required
9.. Telecom Ne
etwork provider Approval, *if
* required
10
0. Proof of Ce
ertification/Listtings, as specified (eg. UL, FM , CE etc.)
11
1. SASO certiffication}
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 16
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
١٤٤٤/٠٨/٠٨ ﺍﻟﺘﺎﺭﻳﺦ
٢٨/٠٢/٢٠٢٣ ﺍﻟﻤﻮﺍﻓﻖ
ﺭﻣﺰ ﺍﻟﺸﻬﺎﺩﺓ ٥٢٨١٥٥٢٣
ﺷﻬﺎﺩﺓ
ﺍﻟﺮﻳﺎﺽ
ﺍﻟﺴﻌﻮﺩﻳﺔ
١٣٢٤٣٦٨٩ ﺭﻗﻢ ﺍﻹﺷﺘﺮﺍﻙ :
ﻣﺼﺪﺭﻩ : ﺭﻗﻢ ﺍﻟﺴﺠﻞ ﺍﻟﺘﺠﺎﺭﻱ١٠١٠٠٧١٧٠٦ :
ﻛﺘﺎﺑﺔ ﺭﻗﻤﺎ
ﺛﻤﺎﻧﻴﺔ ﻣﺸﺘﺮﻛﻴﻦ ٨ ﻋﺪﺩ ﺍﻟﻤﺸﺘﺮﻛﻴﻦ ﺍﻟﺴﻌﻮﺩﻳﻴﻦ
ﺗﺴﻌﺔ ﻭ ﺛﻼﺛﻮﻥ ﻣﺸﺘﺮﻛﺎ ٣٩ ﻋﺪﺩ ﺍﻟﻤﺸﺘﺮﻛﻴﻦ ﻏﻴﺮ ﺍﻟﺴﻌﻮﺩﻳﻴﻦ
ﺳﺒﻌﺔ ﻭ ﺍﺭﺑﻌﻮﻥ ﻣﺸﺘﺮﻛﺎ ٤٧ ﺍﻟﻤﺠﻤﻮﻉ
ﺗﺸﻬﺪ ﺍﻟﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ ﺑﺄﻥ ﺍﻟﻤﻨﺸﺄﺓ ﺍﻟﻤﺬﻛﻮﺭﺓ ﺃﻋﻼﻩ ﻗﺪ ﺃﻭﻓﺖ ﺑﺈﻟﺘﺰﺍﻣﺎﺗﻬﺎ ﺗﺠﺎﻩ ﺍﻟﻤﺆﺳﺴﺔ
ﻭﻓﻖ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻤﻘﺪﻣﺔ ﻣﻨﻬﺎ ﺣﺘﻰ ﺗﺎﺭﻳﺦ ﺇﺻﺪﺍﺭ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ،ﻭﺍﻟﺘﻲ ﺗﻢ ﻣﻨﺤﻬﺎ ﻟﺘﻘﺪﻳﻤﻬﺎ ﻷﻳﺔ ﺟﻬﺔ ﺗﻄﻠﺒﻬﺎ ،ﻭﻫﻲ
ﺻﺎﻟﺤﺔ ﻟﺠﻤﻴﻊ ﺍﻷﻏﺮﺍﺽ ﺍﻟﺘﻲ ﻧﺺ ﻋﻠﻴﻬﺎ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ ﻓﻲ ﺍﻟﻤﺎﺩﺓ ) (١٩/٦ﻣﻨﻪ.
ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﺳﺎﺭﻳﺔ ﺍﻟﻤﻔﻌﻮﻝ ﺣﺘﻰ ١٤٤٤/٠٩/٠٧ﻫـ.
ﻋﻦ ﻃﺮﻳﻖ ﺍﺳﺘﺨﺪﺍﻡ ﺃﻭ ﻳﻠﺰﻡ ﺍﻟﺘﺤﻘﻖ ﻣﻦ ﺻﺤﺔ ﻭﺻﻼﺣﻴﺔ ﺍﻟﺸﻬﺎﺩﺓ ﻋﺒﺮ ﺯﻳﺎﺭﺓ ﺍﻟﺮﺍﺑﻂ
ﺍﻟﺮﻣﺰ ﺍﻟﻤﻌﺮﻑ ﺍﻟﺘﺎﻟﻲ : ﺃﺩﻧﺎﻩ ﻓﻲ ﺍﻟﻤﻮﻗﻊ ﺍﻹﻟﻜﺘﺮﻭﻧﻲ ﻟﻠﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻹﺟﺘﻤﺎﻋﻴﺔ
www.gosi.gov.sa/vc
ﺗﻌﺪ ﻫﺬﻩ ﺍﻟﺸﻬﺎﺩﺓ ﻣﻦ ﺍﻟﻮﺛﺎﺋﻖ ﺍﻻﻟﻜﺘﺮﻭﻧﻴﺔ ﺍﻟﺤﻜﻮﻣﻴﺔ ﺍﻟﺮﺳﻤﻴﺔ ،ﻭﻳﺤﻈﺮ ﻗﻄﻌﻴﺎ ﺗﻘﻠﻴﺪﻫﺎ ﺃﻭ ﺇﺩﺧﺎﻝ ﺃﻱ ﺗﻌﺪﻳﻼﺕ ﻋﻠﻴﻬﺎ ﺳﻮﺍﺀ ﺑﺎﻹﺿﺎﻓﺔ ﺃﻭ ﺍﻟﺤﺬﻑ
ﺃﻭ ﺍﻟﺘﻐﻴﻴﺮ ﻓﻲ ﺑﻴﺎﻧﺎﺗﻬﺎ ﺃﻭ ﻏﻴﺮ ﺫﻟﻚ ﻣﻦ ﺍﻧﻮﺍﻉ ﺍﻟﺘﻌﺪﻳﻞ ،ﻭﺗﻌﺪ ﺍﻟﺸﻬﺎﺩﺓ ﻻﻏﻴﺔ ﺇﺫﺍ ﺷﺎﺑﻬﺎ ﺷﻲﺀ ﻣﻦ ﺫﻟﻚ ،ﻛﻤﺎ ﺗﻌﺮﺽ ﺻﺎﺣﺒﻬﺎ ﻟﻠﻤﻼﺣﻘﺔ ﺍﻟﻨﻈﺎﻣﻴﺔ
ﺃﻣﺎﻡ ﺍﻟﺠﻬﺎﺕ ﺍﻟﻤﺨﺘﺼﺔ ﺑﺎﻹﺿﺎﻓﺔ ﺇﻟﻰ ﻣﺎﻳﻔﺮﺿﻪ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ﻣﻦ ﻋﻘﻮﺑﺎﺕ ،ﻭﻻﻳﺠﻮﺯ ﺗﺪﺍﻭﻝ ﺍﻟﺸﻬﺎﺩﺓ ﺇﻻ ﻓﻲ ﺍﻷﻏﺮﺍﺽ ﺍﻟﺘﻲ
ﺃﺻﺪﺭﺕ ﻷﺟﻠﻬﺎ ﻭﻓﻘﺎ ﻷﺣﻜﺎﻡ ﻧﻈﺎﻡ ﺍﻟﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ،ﻭﺍﻟﻤﺆﺳﺴﺔ ﺍﻟﻌﺎﻣﺔ ﻟﻠﺘﺄﻣﻴﻨﺎﺕ ﺍﻻﺟﺘﻤﺎﻋﻴﺔ ﻏﻴﺮ ﻣﺴﺆﻭﻟﻪ ﻋﻦ ﺃﻱ ﺁﺛﺎﺭ ﺃﺧﺮﻯ ﻣﺘﺮﺗﺒﺔ
ﻗﺒﻞ ﺍﻟﻐﻴﺮ ﻋﻦ ﺍﻟﺸﻬﺎﺩﺓ ﻭﻏﻴﺮ ﻣﺴﺆﻭﻟﺔ ﻋﻦ ﺃﻱ ﻋﻤﻠﻴﺔ ﺗﺰﻭﻳﺮ ﺃﻭ ﺗﻌﺪﻳﻞ ﺗﺘﻢ ﻋﻠﻰ ﺍﻟﺒﻴﺎﻧﺎﺕ ﺍﻟﻮﺍﺭﺩﺓ ﻓﻴﻬﺎ .
100221051354666
ﺗﺸﻬﺪ اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺄن اﻟﻤﻜﻠﻒ أدﻧﺎه ﻣﺴﺠﻞ ﻓﻲ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ
ﺑﺘﺎرﻳﺦ 2017/08/22
Hereby, The General Authority of Zakat & Tax (GAZT) certifies that the taxpayer below is
VAT registered on 22/08/2017
ﻛﻤﻜﻠﻒ ﻣﺴﺠﻞ ﻓﻲ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ،ﻻ ﻳﺠﻮز ﻟﻚ ﺗﺤﺼﻴﻞ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ﻣﻦ ﻋﻤﻼﺋﻚ ﻗﺒﻞ ﺗﺎرﻳﺦ
ﻧﻔﺎذ اﻟﺘﺴﺠﻴﻞ ﺑﺎﻟﻀﺮﻳﺒﺔ .ﻓﻲ ﺣﺎل ﺗﺒﻴﻦ ﻏﻴﺮ ذﻟﻚ ،ﺳﺘﻘﻮم اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺘﻨﻔﻴﺬ اﻟﻐﺮاﻣﺎت اﻟﻤﺴﺘﺤﻘﺔ
100221051354666
ﻛﻤﻜﻠﻒ ﻣﺴﺠﻞ ﻓﻲ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ،ﻻ ﻳﺠﻮز ﻟﻚ ﺗﺤﺼﻴﻞ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ﻣﻦ ﻋﻤﻼﺋﻚ ﻗﺒﻞ ﺗﺎرﻳﺦ
ﻧﻔﺎذ اﻟﺘﺴﺠﻴﻞ ﺑﺎﻟﻀﺮﻳﺒﺔ .ﻓﻲ ﺣﺎل ﺗﺒﻴﻦ ﻏﻴﺮ ذﻟﻚ ،ﺳﺘﻘﻮم اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺘﻨﻔﻴﺬ اﻟﻐﺮاﻣﺎت اﻟﻤﺴﺘﺤﻘﺔ
100221051354666
ﻛﻤﻜﻠﻒ ﻣﺴﺠﻞ ﻓﻲ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ،ﻻ ﻳﺠﻮز ﻟﻚ ﺗﺤﺼﻴﻞ ﺿﺮﻳﺒﺔ اﻟﻘﻴﻤﺔ اﻟﻤﻀﺎﻓﺔ ﻣﻦ ﻋﻤﻼﺋﻚ ﻗﺒﻞ ﺗﺎرﻳﺦ
ﻧﻔﺎذ اﻟﺘﺴﺠﻴﻞ ﺑﺎﻟﻀﺮﻳﺒﺔ .ﻓﻲ ﺣﺎل ﺗﺒﻴﻦ ﻏﻴﺮ ذﻟﻚ ،ﺳﺘﻘﻮم اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺘﻨﻔﻴﺬ اﻟﻐﺮاﻣﺎت اﻟﻤﺴﺘﺤﻘﺔ
1020253841
ﺷﻬﺎدة
CERTIFICATE
ﺗﺸﻬﺪ اﻟﻬﻴﺌﺔ اﻟﻌﺎﻣﺔ ﻟﻠﺰﻛﺎة واﻟﺪﺧﻞ ﺑﺄن اﻟﻤﻜﻠﻒ /ﺷﺮﻛﺔ اﻟﺸﺮق اﻻوﺳﻂ ﻟﻠﺰراﻋﺔ
وﻗﺪ ﻣﻨﺢ ﻫﺬه اﻟﺸﻬﺎده ﻟﺘﻤﻜﻴﻨﻪ ﻣﻦ إﻧﻬﺎء ﺟﻤﻴﻊ ﻣﻌﺎﻣﻼﺗﻪ ﺑﻤﺎ ﻓﻲ ذﻟﻚ ﺻﺮف ﻣﺴﺘﺤﻘﺎﺗﻪ
اﻟﻨﻬﺎﺋﻴﺔ ﻋﻦ اﻟﻌﻘﻮد.
11 DRA
AFT WAR
RRANTY
Y
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 17
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
شــركــــة الشـــــــرق األوســـــــط للزراعـــــــــة
Middle East Agriculture Company
41953 الريــاض غرفــة تجاريــــــــة0505510151 ت. ريـال سعــودي س0.555.555 م رأس المــال.م.ش
Ltd. Co. Capital SR. 5,000,000 - C.R. 1010071706 C.C. No. 36904
PRELIMINARY WARRANTY
Middle East Agriculture Company, warranty the above mentioned products for a period of 18 months
from date of delivery or 12 months from date of testing and commissioning whichever comes first
against manufacturing defects under normal operating conditions.
Note: This "Preliminary Warranty" is intended to indicate the warranty terms of the proposed products prior to purchase and/or
delivery of the materials. The “Limited Warranty” Shall be requested from MEAC representative after purchasing and delivering
the materials
12 MAN
NUFACT
TURER RECOMM
R ENDED SPARE PARTS
P
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 18
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
7 Servicing/inspection
7.7.2 Recommended spare parts stock for 2 years' operation to DIN 24296
Table 17: Quantity of spare parts for recommended spare parts stock6)
Part No. Description Number of pumps (including stand-by pumps)
2 3 4 5 6 and 7 8 and 9 10 and
more
230 Impeller 1 1 2 2 3 4 50 %
321.01 Rolling element bearing, motor end 1 1 2 2 3 4 50 %
321.02 Rolling element bearing, pump end 1 1 2 2 3 4 50 %
420 Shaft seal ring, motor end 2 3 4 5 6 7 90 %
433.02 Mechanical seal, pump end 2 3 4 5 6 7 90 %
99-9 Set of sealing elements 4 6 8 8 9 10 100 %
42 of 54 Ama-Porter
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
13 PRE
EVIOUS PROJEC
CT APPRO
OVALS
a) Re
ed Sea Projectts
b) Otther Projects
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 19
1
CLASSSIFICATION: INTERNAL & SSENSITIVE
12/4/22, 8:11 AM Aconex
To
(15) Mr Kennith Maniego - Al Fayhaa Construction and Contracting (+14 more...)
Cc
(26) Mr Rhomel Carlos - Al Fayhaa Construction and Contracting (+25 more...)
Status N/A
DOCUMENT ATTACHMENTS
(1)
(0 selected)
R01-H14C06-AFC- Material Submittal - Additional Submersible Pumps for Oasis & Accepted with
00
MAT-PL-0058 Sunset Restaurant (KSB/MEAC) Comments
ATTRIBUTES
MESSAGE
The attached documents have completed the "R01H14 - [AFCC] Material Submittal - Additional Submersible Pumps for Oasis & Sunset
Restaurant (KSB/MEAC) (MEP BOH)" workflow with the following results :
https://ksa1.aconex.com/hub/index.html 1/3
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
14 TRA
ADE LICE
ENSE
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 20
2
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
15 MAN
NUFACT
TURER CO
ONFIRM
MATION OF THE LOCAL AGENT
A
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 21
2
CLASSSIFICATION: INTERNAL & SSENSITIVE
Materi
ial Sub
bmitta
al Temp
plate
RSG-CN-TM
MP-0007
16 PRO
OJECT REFERENCE LIST
T
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 22
2
CLASSSIFICATION: INTERNAL & SSENSITIVE
MEAC | COMPANY PROFILE 81
17 COM
MPANY PROFILE
P E
RSG-CN-TMP-0007
R FOR IN
NTERNAL USE ONLLY
Rev.
R 00, 01 Oct 2022 Page | 23
2
CLASSSIFICATION: INTERNAL & SSENSITIVE
MEAC
COMPANY PROFILE
MEAC | COMPANY PROFILE 2
About
Abunayyan Holding
MEAC | COMPANY PROFILE 3
Our Mission
Our Vision
Our Values
CONSTRUCTION
MEAC | COMPANY PROFILE 8
Timeline
Abdullah Abunayyan introduces
diesel-powered turbine pump to the
Kingdom.
Establishment of:
ECO
ATC
EEIC Saudi
AEC
Meter
UFC
KSB JCB
Saudi Pumps AcwaPower
Tumpane Arabia
1950 1952 1978 1983 1987 1990 1992 1993 1998 2002 2004 2005 2013 2014 2017
IICS
Abdullah MEAC
Abunayyan Saudi Berkefeld Limited is Citiscape Toray Membrane
Establishment established. (In 2001, becomes Middle East
Founded Water & Environment Technology
Saudi Company WETICO)
French
Company
Established (In 2009
became Arabian
Qudra)
MEAC | COMPANY PROFILE 9
01
ABOUT MEAC
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 10
A LEADING INTEGRATOR
AND PROVIDER OF
WATER MANAGEMENT
SOLUTIONS
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 12
MISSION
DRIVING Through:
SUSTAINABLE
• Quality and Reliable Products
• Optimized Operation Processes
• Value-Add Pre-Post Sales
GROWTH
Services
MOTIVATION AWARENESS
Competent, engaged, motivated Knowledge sharing & Education for
& committed staff doing business internal and external stake holders.
with passion.
M E AC
EXCELLENCE COMMITMENT
Efficient operations, high Integrity, Honesty, Reliability, Quality,
performance & advanced technology. Customer Success & Environment
protection.
MEAC | COMPANY PROFILE 15
GEOGRAPHY
6 26 MASTER
Branches Sub-Dealers Branch in Jebel Ali
Free Zone - UAE
MEAC | COMPANY PROFILE 16
02
OFFERINGS
& SERVICES
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 17
OFFERING
Products Supply
• Readily Available Products
• Distributed Warehouses and Inventory
• Multi Sales Outlets
• Authorized Dealers Network
MEAC | COMPANY PROFILE 20
03
STRATEGIC
PARTNERS
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 22
04
PRODUCTS
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 27
01
IRRIGATION
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 28
SPORTS FIELD • Soccer fields, Golf Courses, Polo Fields, Race Tracks
ROTORS • Use: Natural turf Irrigation and Cooling & Cleaning
synthetic turf
• Plastic and stainless steel pop-up riser
• Radius of through up to 50m. Operating pressure 4
Bar to 7 Bar
• Matched precipitation nozzles
• Brands: Hunter - USA
MEAC | COMPANY PROFILE 31
S
• Type: Regular, Modular and Decoder
• 4 – 99 stations
• VAC 120/230 V, 50/60 Hz and VDC 9-11 V
• Brands: Hunter - USA
MEAC | COMPANY PROFILE 34
02
AUTOMATION &
IRRIGATION
CENTRAL CONTROL
SOLUTIONS
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 40
MANAGEMENT & IRRIGATION • “Store and Forward” capabilities for almost unlimited coverage area
• Multi Communication Media: Radio, Fiber optic, Hardwire, GSM,
CENTRAL CONTROL GPRS and any combination
• Powerful radios for wireless communication
• 100% secured Seven Layers communication protocol
• Real time Supervisory, Command & Data Acquisition (SCADA)
• Open and Semi-Open Architecture
• Complete system engineering, design and technical operational
support
• Comprehensive water management significantly reduces water
budget, labor cost and energy consumption.
• Graphics applications and HMI capabilities (Human Machine
Interface)
• RTUs (Remote Terminal Units). Master and Slaves
• Modular I/Os (Inputs/Outputs) Weather based and water budgeting
irrigation scheduling
• Leak detection and water management programs
• Integrated instrumentation: Weather station, pressure sensors, level
sensors, flow sensors and flow meters
• 100% secured Seven Layers communication protocol
MEAC | COMPANY PROFILE 41
03
WATER PUMPS
FOR BUILDING
SERVICES
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 44
SEWAGE • Applications:
Commercial and Residential Applications
SUBMERSIBLE PUMPS
• Type:
Submersible
• Material:
Cast iron
• Range:
Flow up to 50 LPS (80 GPM) and Head up to 47M
• Brands:
1. KSB - Germany
2. Flygt - Sweeden
MEAC | COMPANY PROFILE 48
04
FIRE FIGHTING
PUMPS
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 50
05
POWER
GENERATION
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 52
06
HUMIDIFICATION
AND OUTDOOR
ADIABATIC
COOLING &
DUST CONTROL
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 54
07
PIPES,
FITTINGS AND
ACCESSORIES
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 56
08
LANDSCAPE
FURNITURE
AND SUPPLIES
WWW.MEAC.COM.SA
MEAC | COMPANY PROFILE 61
WASTE MANAGEMENT
Sineu Graff Jumbo®
65
MOBILE GARDENS
Sineu Graff
65
TREE GRILLES
Sineu Graff Customization
MEAC | COMPANY PROFILE 66
CATALOGUE PLAYGROUND
Galopin Qatar
68
CUSTOMIZED PLAYGROUND
Galopin Spain
69
INTEGRADO PLAYGROUNDS
Inter-Play
MEAC | COMPANY PROFILE 70
MOUV’ROC ® UNITS
Sineu Graff
MEAC | COMPANY PROFILE 72
SAFETY FLOORING
Playgrounds
MEAC | COMPANY PROFILE 74
MAJLIS OMAN
Lumascape Muscat
80
CONTACT US
WWW.MEAC.COM.SA