SEL-311C: Transmission Protection System
SEL-311C: Transmission Protection System
SEL-311C: Transmission Protection System
1
ADDITIONAL FUNCTIONS
85
BRM RIO DFR HMI LGC LOC PMU BRM Breaker Wear Monitor
Line LDE Load Encroachment
LOC Fault Locator
52PB SBM SER SBM Station Battery Monitor
16SEC 1
Copper or Fiber-Optic
*Optional Feature
1 1 1 3 1 or 2*
2
KEY FEATURES
PROVIDE UNIVERSAL TRANSMISSION LINE PROTECTION WITH
ADVANCED PROTECTION, AUTOMATION, AND CONTROL.
3
PRODUCT OVERVIEW
FRONT PANEL
4
Optional field-configurable, programmable operator
pushbuttons with user-configurable labels.
Optional programmable
front-panel LEDs for Optional independent SafeLock® trip/close
custom alarms. pushbuttons with high-visibility indication.
5
PRODUCT OVERVIEW
REAR PANEL
High-current interrupting
output contacts. Optional expanded I/O.
6
IRIG-B input for Optional EIA-485 or
precise timing. fiber-optic serial port.
Advanced SELogic®
control equations.
7
APPLICATIONS
HIGH-SPEED BREAKER FAILURE PROTECTION Open-Phase Detection
Standard-Speed Elements
1.75 1.75
1.5 1.5
1.25 1.25
1 1
0.75 0.75
0.5 0.5
0% 20% 40% 60% 80% 0% 20% 40% 60% 80%
Fault Location in Percent of Set Reach Fault Location in Percent of Set Reach
Single-Phase-to-Ground Faults
8
COMPLETE FAULT AND LOAD COVERAGE Line Angle
X1
Secure Protection Under High Loads M4P
Lenticular Characteristic
Prevent operation of the phase-distance elements under high- (Shown for Comparison)
unique feature permits load to enter a predefined area of the Shaded region shows
area where 3-phase
mho elements are
phase-distance characteristic without causing a trip. M2P
blocked.
F
Improve Coverage PLA
M1P
PLA
R
Implement quadrilateral phase and ground distance elements Reverse Forward
Load Load
for improved fault and arc resistance coverage and reach- Region Region
NLA
NLAR F
Load-Encroachment Characteristic
Compensate for System Conditions Phase and Ground Mho Distance Characteristics
The reach for each of the eight ground-distance elements can
be individually set. The ground-distance elements include two X Axis
zero-sequence compensation factor settings (k01, k0) to accu-
rately calculate ground fault impedance.
Zone 4
Zone 2
Zone 1
R Axis
Zone 3 (Reversed)
Negative-Sequence
Directional Element
9
ACCESSIBILITY
WEB SERVER
Access basic SEL-311C information on a standard Ethernet
network with the built-in web server. View relay status,
Sequential Events Recorder (SER) data, metering information,
and settings through easy access within a local network.
Also, conduct your firmware upgrades remotely through the
Ethernet connection. Web server access requires a relay
password and is limited to read-only viewing of information.
10
MIRRORED BITS COMMUNICATIONS SEL RELAY 1 SEL RELAY 2
T T
TMB1 TMB1
Mirrored Bits communications technology provides bidirec- R R
A TMB2 TMB2 A
tional digital communications between devices. Use Mirrored N N
S S
Bits communications to transmit/receive information between M M
upstream relays and downstream recloser controls to enhance I TMB8 TMB8 I
T T
coordination and achieve faster tripping for downstream faults.
R RMB1 RMB1 R
Patented Mirrored Bits communications is simple, powerful, E
RMB2 RMB2
E
C C
field-proven technology. E E
I I
V V
E RMB8 RMB8 E
FLEXIBLE COMMUNICATIONS
Communications Protocols Communications Media
Mirrored Bits Communications DNP3 Serial Ethernet 10/100BASE-T
IEEE C37.118 Synchrophasors DNP3 IP Ethernet 100BASE-FX*
IEC 61850 GOOSE* Web Server EIA-232 Serial
IEC 61850 MMS* Simple Network Time Protocol (SNTP) EIA-485 Serial*
Parallel Redundancy Protocol (PRP)* FTP
Modbus TCP SEL Fast Messages USB Type B*
Modbus RTU ASCII Fiber-Optic Serial Port*
Telnet IRIG-B
*Optional Feature
11
MAKING ELECTRIC POWER SAFER,
MORE RELIABLE, AND MORE ECONOMICAL