Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Loading Definition

Floor Item Loading

Roof floor Dead Load


Hollow core slab 3.3 kN/m2
Roof insulation 0.5 kN/m2
Water proofing Fnishes (0.1m thk.) 2.5 kN/m2
Services 0.25 kN/m2
Ceiling 0.1 kN/m2

Live Load 1.5 kN/m2


Snow Load 0.691 kN/m2
Wind Load
At center of building (point load) GL 2-5 61.2 kN
At edge of building (point load) GL 1 & 6 30.6 kN

2nd to 7th floor Dead Load


Hollow core slab 3.3 kN/m2
Finishes ( 0.075m thk.) 1.88 kN/m2
Partition 1 kN/m2
Services 0.25 kN/m2
Ceiling 0.1 kN/m2
Cladding 4 kN/m2

Live Load 3 kN/m2


Wind Load
At center of building (point load) GL 2-5 85.4 kN
At edge of building (point load) GL 1 & 6 42.7 kN

1st Floor Dead Load


Non-suspended floor

Load Combination
1 1.35Gk + 1.5w + 1.5 (0.7)QK + 1.5 (0.5)S
2 1.35Gk + 1.5S + 1.5(0.5) Wk + 1.5 (0.7) QK
3 1.35Gk + 1.5Qk + 1.5 (0.5) S + 1.5 (0.5) Wk

Support
Fixed support at all column

Member size
Column size 356x406x634 all other column
356x406x818 at centre column GL 3&4 (1st to 3rd level)
Beam size 686x254x170 at perimeter of building
Truss 350x16 SHS staggered truss
Incline member 324x16 CHS
Tie beam 169x10 CHS Tie beam at incline member

You might also like