Professional Documents
Culture Documents
Flap Barrier User Manual
Flap Barrier User Manual
Flap Barrier
www.esslsecurity.com
【Preface】
Thank you for choosing flap /slide barrier and swing gate,This is a product
with high technology, so please read this manual carefully before operation.
All rights to improve and perfect our products are reserved. We can’t
promise this manual is in full accord with the product you receive, but we will
check and revise the manual at regular interval. No further notification will be
2
CONTENTS
3
1 Product introduction
1.1 Brief introduction
The flap /slide barrier and swing gate is a kind of 2-way speed access
control equipment designed for places with high class security requirements. It is
face recognition and other identification devices,It realizes the intelligent and
shaft.
1. Motor
2. Position sensor
3. Induction plate
4. Bearing
5. Transmission shaft.
6. Swing arm
7. Barrier
Flap core
4
1. Motor
2. Position sensor
3. Induction plate
4. Core
Swing core
The electric control system consists of access control system, control board,
infrared sensor, direction indicator, position sensor, motor, power supply, battery
and so on.
NO Name Function
3 Infrared sensor Detect the passage of people in the lane, Anti pinch
5
Detects and controls the opening and closing position
5 Position sensor
of the gate
1) Turn on the power, wait for the end of the self-examination ; the system
2) After swipe legal card or QR code and fingerprint, Access control device
3) The main board receives open signal, control indicator to green, motor
4) After the passenger passing through the passage in accordance with the
direction indicator mark, the infrared sensor detects the complete process of the
passenger passing through the passage, and issues signal continuously to the
main controller board, until the passenger passes through the passage
completely.
5) After the passenger passes through the passage completely, the main
sound/light alarm signal will be given from main board. The alarm signal will
not be cancelled until the passenger retreats from the passage and the passing is
6
only allowed after reading again the effective card
Standard signal input port, can be connected with most of the access
The turnstile has automatic reset function, if people swipe the authorized
card, but don’t pass through within the settled time, it need to swipe card
Pinch protection;
Self diagnostic and alarm function for convenient maintenance and use
7
Motor Brush DC motor 30W
Communication RS485
2 Equipment Installations
2.1 Installation notes
The gates must be correctly arranged in order, and the left and right gates
facilities;
Please check all wires has been properly connected before power on;
8
2.2 Equipment Installation
1) Tool preparations
Impact drill(including
4 8 Cable Tester
D16 and D14 drills)
4)Put the turnstile in order and alignment .We have mark on the turnstile
for the multichannel, please install the turnstile in order, such as A1-A2-A3-A4
9
10
5) Mark the fixing position of expansion bolts according to fixing plate on
6) Move turnstile and drill hole by impact drill, fix Expansion screws
8)Confirm the lane lines, dig line pipe diameter into the appropriate PVC
line pipe, each lane will AC220V power line RVV3*1.5mm and 3pcs CAT 5 cable
for connect main machine , 1 PCS network cable for access control system (if
install other control system according to the actual situation of laying related field
the wire)
11
9) Move each machine to the corresponding mounting position and point to
11) Check each gate alignment, all lane are completed debugging and
2.3 Connection
cable.such as 1--1,2--2(N1--CON1,N2--CON2)
12
13
(A1)single core (A2)double core (A3)double core (A4)single core
Connect the mater machie power adapter to 220V and connect the protective
ground wire.
Access control device send open signal to control board , gate will open
immediately ,The relay time of access control device must be set to 0-1 seconds.
Enter SW Exit SW
Main board
mark:
SW1---NO
Gnd-----COM
Access control device SW2----NO
Gnd-----COM
NC NO COM NC NO COM
1)Check wire:Check whether the connection wire of the gate and the power
line are properly connected before power on. If there is any abnormality on the
2)Function test:After power on the machine will open- close, and open
14
-close, this process is machine self-check, after the sound from buzzer means
3)The control board will give alarm if stand in the lane without swipe
card ;if no response when infrared sensor be block, please check if the
receive sensor is no bright when no blocked .If the red led of receive sensor is
always bright ,that means the sensors no shoot well ,please adjust to aligned.
4)The relay time of access control device must be set to 0-1 seconds.
5)When the valid card is swiped, the indicator light turn green,If the
indicator indicates incorrect or turn off and alarm immediately when go into
first sensor, This means that the signal connection is opposite, exchange the open
impact sound, etc; Confirm motor is no idle; the indicator light is correct and the
If it tests well before installation, then fixed it; before you install and maintain
The product must be earthed, and an earth leakage breaker is necessary on the
power supply;
The depth of buried PVC tube should be greater than 60mm, and the exposed
height above the ground should be greater than 50mm. The exit mouth should
If you use the turnstile outdoor, it need to add a 100-200mm cement platform
for the turnstile to do damp proof, also need to add a canopy to protect the
Please keep the control button or remote control far away from the children;
Please don’t use the turnstile under the thunder and lightning condition to get
16
Main board
18
3.3 Parameter instruction
Description: the factory has been set up parameters, please do not modify, if
you need to modify the parameters, please proceed under technical guidance.
19
一、1. Description
1) The display screen is refers to the main control board of 3 LED display
from left to right. Four buttons: up and down for switch, ENT for sub-menu, ESC
for previous menu. Long press "ENT " 3 seconds unlock into the menu.Select
advanced parameters, and long press "ENT + Down " 3 seconds unlock into the
menu.
2.Menu setting
Item Explain
1. Parameters
1.1 Counter Display pass through count
Set Gate Mode(NO, NC and card, free or reject) of enter and exit
1.NC both Rej 2 .NC both free 3.NC both card (default)
4 NC Card Free 5 .NC Card Rej 6. NC Free card
1.2 Gate Mode
7.NC Free Rej 8.NC Rej Free 9.NC Rej Card
10.NO Both Free 11.NO Both Card
12.NO Card Free 13.NO Free Card
1.3 PassTimeout Set maximum waiting time 10-255, unit 0.1s, (default 5seconds)
Set Scan Card With Memory Mode
1.4 Memory
0 two-way disable(default),1. enter allow,2. exit allow,3. two-way allow
Set Can Scan Card After Entry Lane,Please do not modify
1.5 ReadIn Lane
1. disable (default), 2. allow
1.6 Open Delay Set Authorized Open Door Delay 0-255, unit 0.1s, (default 0)
1.7 CLS. Delay Set Close Door Delay After Passage Finish0-255, unit0.1s, (default 0)
1.8 Motor1 SPD. Set master Motor basic speed 1-100
1.9 Motor2 SPD. Set vice motor basic speed 1-100
1.10 Pass End Set IR Check passage end position 1. exit (default), 1 safety
1.11 Intrude Set Set Intrude Alarm Mode 1.no alarm, 2 .alarm (default), 3. alarm and close
Set Passage From Reverse Alarm Mode
1.12 Reverse Set.
1 no alarm, 2. alarm, 3 alarm and close (default),
Set Tail-Gating Alarm Mode 1 no alarm, 2. alarm, 3 alarm and close
1.13 Tail-Gating
(default),
1.14 Adv. Param.
20
.1 EN_O_SPD.1 Set Motor 1 Speed when Open Door for Entry
.2 EN_C_SPD.1 Set Motor 2 Speed when Open Door for Entry
.3 EX_O_SPD.1 Set Motor 1 Speed when Close Door for Entry
.4 EX_C_SPD.1 Set Motor 2 Speed when Close Door for Entry
.5 EN_O_SPD.2 Set Motor 1 Speed when Open Door for Exit
.6 EN_C_SPD.2 Set Motor 2 Speed when Open Door for Exit
.7 EX_O_SPD.2 Set Motor 1 Speed when Close Door for Exit
.8 EX_C_SPD.2 Set Motor 2 Speed when Close Door for Exit
.9 Save Fact. Save the current parameter to factory default
Set add relay use for passed counter
.10 Relay Mode
1. disable,(default),2.Enter allow, 3.Exit allow ,4. both ballow
Set automatic report gate status when on change 1 disable (default), 2
.11 Auto Report
allow
.12 NO Direction Set the normally open the gate opening direction , the default enter
Set the normally open the gate opening direction when Power failure , the
.13 Power Lost
default enter
.14 Barriers signal or double machine work 1 double (default) , 2 signal
.15 IR Speed Set IR Sensor Sensitivity(1-100) 0-100(default 100)
.15 IR Type Set infrared sensor type 1 PNP (default), 2 NPN
.16 IR Logic Set Use Local IR Sensor Logic
.17 Motor Pro. Set the motor over current protection threshold, the default 2.5A
.18 Self Check Set use self check when power on, disabled by default
.19 LED Mode Set LED indicator default parameter 1 Static LED,2 Square LED
.20 Set DevType Set Controller Device Type 1 Tripod 2 Flap gate, 3 Swing gate
2. System Set
2.1 Language Set Menu Display Language
2.2 Device Type Display Controller Device Type
2.3 Version Display hardware and firmware version information
2.4 Set Address Set Device Logic Address
2.5 RS485 Baud Set the baud rate of the RS485
2.6 Reset Reset all setting to factory default.
2.7 Restart Restart controller
3. Factory Test
3.1 Cycle Test Open and close door cycle test
3.2 Input Check Check input interface status
3.3 Output Test Output interface test
21
4 Trouble shooting and maintenance
4.1 Trouble shooting
123456789
Control board
ESC ENT
The box of control is buckle type ,It can open the upper cover of the buckle
Answer:Change pass mode two way free to two way card in the menu.
Fault 2: swipe into the first sensor, Gate give alarm and close immediately?
Answer:This means that the signal connection is opposite, exchange the open
Answer:Take the other indicator or control board from other lane and check it
and use the millimeter to check whether the connection between the master
22
machine and the vice machine is continuous ;3)Measure whether M1 or M2 has
voltage output when restarting the power supply;4)Check fuse in the board.
off the power and use the millimeter to check whether the connection between the
off the power and use the millimeter to check whether the connection between the
master machine and the vice machine is continuous.3)Check the vice board
Answer:1)Check whether the POS Sensor connect wires are loose;2)Turn off the
power and use the millimeter to check whether the connection between the
master machine and the vice machine is continuous.3)Check the vice board
Fault 9: swing the side of the pendulum rod can only open 90 degrees, or
Answer:1) check the abnormal barrier and the normal one whether there is
any difference between the fixed angles and whether the pendulum rod is struck
or not 2)Check the iron sheet of core whether is loose, if loose readjust it.
Fault 10: The swing gate move slowly or shake or give big noisy?
Answer:Check core
23
4.2 Maintenance
1. Maintenance Content:
* Keep the turnstile housing and card reader panels of turnstile gates clean;
* Check the connectors and wiring points to ensure the reliability of the
connection.
2 Maintenance Methods:
1. Cleaning: Check the housing and card reader panels of the gate, and remove the
2. Rust removal and Lubrication: Check the movement of the flap /slide gate and
swing gate, remove rust with sand paper and spread with anti-rust oil if corroded;
3. Screws fastening: Check the connection of the various moving parts, fasten the
screws where they are loose to avoid causing fault for long-running;
4. Circuit board cleaning: Cut off the power, and wipe dust of the board by using
a clean brush;
5. Lines Checking: Check the connecting lines and solder reinforcement if they
daily maintenance, please do not feel free to disassemble it. If a fault occurs while
running, Please notify our service departments or the authorized service agencies
improper operation.
Guarantee Instruction
Our company products are guaranteed for one year, from date of sale,
● During the warranty period, all faults caused by the product itself can be
maintained for free. Please carry the filled warranty card and the purchase invoice
to the authorized service centers across the country or return the machine to our
● Over the period of free maintenance, faults or damages can be maintained with
additional charge.
etc.) ;
Note: The warranty card and purchase invoice are used as warranty certificates
to maintain the machine. Please reserve them carefully. Lose won’t repair.
25
User Data Card
User Address
Machine
Model
Seller Address
Sell Date
Maintenance Records
26
#24, Shambavi Building, 23rd Main, Marenahalli, JP Nagar 2nd Phase, Bengaluru - 560078
Phone : 91-8026090500 | Email : sales@esslsecurity.com