Download as pdf or txt
Download as pdf or txt
You are on page 1of 27

USER MANUAL

Flap Barrier

www.esslsecurity.com
【Preface】

Thank you for choosing flap /slide barrier and swing gate,This is a product

with high technology, so please read this manual carefully before operation.

Please keep this manual for future reference.

Only trained professionals who understand electric and mechanical risk of

product are qualified to install and operate gate system so as to avoid

unnecessary dangers caused by misoperation.

All rights to improve and perfect our products are reserved. We can’t

promise this manual is in full accord with the product you receive, but we will

check and revise the manual at regular interval. No further notification will be

sent in the case of any modifications to the manual.

2
CONTENTS

1 Product introduction .......................... 4

1.1 Brief introduction ........................ 4

1.2 Product structure and principle ........... 4

1.3 Function Features ......................... 7

1.4 Technical parameters ...................... 7

2 Equipment Installation ........................ 8

2.1 Installation notes ........................ 8

2.2 Equipment Installation .................... 9

2.3 Connection ............................... 12

2.4 Debugging instruction .................... 14

2.5 Use notes ................................ 15

3 Control Board and parameter instruction ....... 16

3.1 Control Board instruction ................ 16

3.2 Wiring diagram ........................... 18

3.3 parameter instruction .................... 19

4 Trouble shooting and maintenance .............. 22

4.1 Trouble shooting ......................... 22

4.2 maintenance .............................. 24

3
1 Product introduction
1.1 Brief introduction

The flap /slide barrier and swing gate is a kind of 2-way speed access

control equipment designed for places with high class security requirements. It is

easy to combine IC access control, ID access control, code reader, fingerprint,

face recognition and other identification devices,It realizes the intelligent and

efficient management of passage.

1.2 Product structure and principle

The structure of the product is mainly composed of mechanical system and

electric control system.

The mechanical system is composed of cabinet and core mechanism. The

cabinet is equipped with indicator, infrared sensor and other device.

The core mechanism is composed of motor, position sensor, transmission,

shaft.

1. Motor

2. Position sensor

3. Induction plate

4. Bearing

5. Transmission shaft.

6. Swing arm

7. Barrier
Flap core

4
1. Motor

2. Position sensor

3. Induction plate

4. Core

Swing core

The electric control system consists of access control system, control board,

infrared sensor, direction indicator, position sensor, motor, power supply, battery

and so on.

NO Name Function

IC/ID card access control, fingerprint, face


Access control recognition, code reader, access control device send
1
device delay signal to the turnstile board door signal. Remote
control or button to open the door(select the configuration)

The control center of the system, when receiving the

access control device delay signal, it control motor

running so that the gate opened, the direction


Main board
2 indicator light turns green, while receiving core
(control)
position sensor, infrared sensor, and judging and

processing logic of these signals, keep the gate

components of intelligent coordination work

3 Infrared sensor Detect the passage of people in the lane, Anti pinch

4 Indicator Display the current channel status

5
Detects and controls the opening and closing position
5 Position sensor
of the gate

6 Motor Drive the barrier moving

7 Power Supply power supply to control board

The gate will keep open the door automatically when


8 12V battery
power failure

System Operation Principle

1) Turn on the power, wait for the end of the self-examination ; the system

enters into work mode;

2) After swipe legal card or QR code and fingerprint, Access control device

send opening signal to main board.

3) The main board receives open signal, control indicator to green, motor

acts to open the barrier.

4) After the passenger passing through the passage in accordance with the

direction indicator mark, the infrared sensor detects the complete process of the

passenger passing through the passage, and issues signal continuously to the

main controller board, until the passenger passes through the passage

completely.

5) After the passenger passes through the passage completely, the main

controller board delivers a signal to the counter, which will increase 1

automatically, ending the passing process.

6) If the passenger forgets to swipe card when go into the passage,

sound/light alarm signal will be given from main board. The alarm signal will

not be cancelled until the passenger retreats from the passage and the passing is
6
only allowed after reading again the effective card

1.3 Function Features

 Varied pass mode can be chosen flexibly;

 Standard signal input port, can be connected with most of the access

control board, fingerprint device and scanner other equipment;

 The turnstile has automatic reset function, if people swipe the authorized

card, but don’t pass through within the settled time, it need to swipe card

again for entry;

 Card-reading Recording function: single-directional or bi-directional

access can be set by the users

 Automatic opening after emergency fire signal input

 Pinch protection;

 Anti-tailgating control technology

 Automatic detection, diagnosis and alarm, sound and light alarm,

including trespassing alarm, anti-pinch alarm and anti-tailgating alarm.

 High light LED indicator , displaying passing status.

 Self diagnostic and alarm function for convenient maintenance and use

 Gate will automatically open when power failure(connect 12V battery)

1.4 Technical parameter

Housing Material 304 stainless steel

Power AC220±10% V、50HZ

Working voltage DC 24V

7
Motor Brush DC motor 30W

Working temperature -20 ℃ - 60 ℃

Work environment ≦90%, no condensation

Passive signals (relay signals, dry


Open signal
contact signals,)

Communication RS485

Pass rate ≦35 person/min

Flap gate 550mm


Passage width
Swing gate 600--900mm

2 Equipment Installations
2.1 Installation notes

 Please read this manual carefully before install it;

 The gates must be correctly arranged in order, and the left and right gates

of each lane should be aligned;

 If the equipment is used outdoors, equipment should be installed at the

establishment of 100-200mm high cement platform, so as to prevent

moisture, and install ceilings and other sunscreen, rain protection

facilities;

 Protective earth wire must be connected;

 Please confirm each RJ45 cable straight through;

 Please check all wires has been properly connected before power on;

 Please test all function before using.

8
2.2 Equipment Installation

1) Tool preparations

Screw driver and other common


1 A set of hexagon spanner 5
wiring tool

2 Cross screwdriver 6mm 6 Millimeter

3 Open spanner 17-19mm 7 M12x100 Expansion screws 8pcs

Impact drill(including
4 8 Cable Tester
D16 and D14 drills)

2) Ensure the installation location and the system composition ,prepare to

install after carrying out the system planning;

3) Make well of installation of equipment foundation base.

4)Put the turnstile in order and alignment .We have mark on the turnstile

for the multichannel, please install the turnstile in order, such as A1-A2-A3-A4

on one side a1-a2-a3-a4 on the other side.

9
10
5) Mark the fixing position of expansion bolts according to fixing plate on

the bottom of each turnstile.

6) Move turnstile and drill hole by impact drill, fix Expansion screws

7) Tighten the expansion screw after the functional test is completed

Fit expansion screws

8)Confirm the lane lines, dig line pipe diameter into the appropriate PVC

line pipe, each lane will AC220V power line RVV3*1.5mm and 3pcs CAT 5 cable

for connect main machine , 1 PCS network cable for access control system (if

install other control system according to the actual situation of laying related field

the wire)

11
9) Move each machine to the corresponding mounting position and point to

the expansion bolt position;

10) Check again;

11) Check each gate alignment, all lane are completed debugging and

function test, then tighten the nut.

2.3 Connection

1)Connect Cable between the master and the vice machine

The main board is connected directly to the auxiliary board by a network

cable.such as 1--1,2--2(N1--CON1,N2--CON2)

Refer to the following picture.

12
13
(A1)single core (A2)double core (A3)double core (A4)single core

Main board Auxiliary board

Infrared sensor receiver Infrared sensor receiver

Credit card panel

2) Connecting AC220V power input

Connect the mater machie power adapter to 220V and connect the protective

ground wire.

3)Access control device connect

Access control device send open signal to control board , gate will open

immediately ,The relay time of access control device must be set to 0-1 seconds.

Enter SW Exit SW

SW1 Gnd SW2 Gnd

Main board
mark:

SW1---NO
Gnd-----COM
Access control device SW2----NO
Gnd-----COM
NC NO COM NC NO COM

2.4 Debugging instruction

1)Check wire:Check whether the connection wire of the gate and the power

line are properly connected before power on. If there is any abnormality on the

power supply process, check the connection wires firstly;

2)Function test:After power on the machine will open- close, and open
14
-close, this process is machine self-check, after the sound from buzzer means

finish self-check. Don’t stand in the lane in the process of self-check;

3)The control board will give alarm if stand in the lane without swipe

card ;if no response when infrared sensor be block, please check if the

infrared sensors are aligned,Under normal circumstances, the red led of

receive sensor is no bright when no blocked .If the red led of receive sensor is

always bright ,that means the sensors no shoot well ,please adjust to aligned.

4)The relay time of access control device must be set to 0-1 seconds.

5)When the valid card is swiped, the indicator light turn green,If the

indicator indicates incorrect or turn off and alarm immediately when go into

first sensor, This means that the signal connection is opposite, exchange the open

signal connect terminal of SW1 Gnd to SW2 Gnd

6)Check and test carefully, running smoothly, no abnormal condition, no

impact sound, etc; Confirm motor is no idle; the indicator light is correct and the

infrared pinch function is normal before putting into use.

2.5 Notice of use

 If it tests well before installation, then fixed it; before you install and maintain

it, please cut off the power;

 The product must be earthed, and an earth leakage breaker is necessary on the

power supply;

 The depth of buried PVC tube should be greater than 60mm, and the exposed

height above the ground should be greater than 50mm. The exit mouth should

be bending back to avoid water dipping inside the tube;

 Don’t change the inside wire of the turnstile casually;


15
 Please don’t open the turnstile when it is under the working status;

 In installation, please make each door of the lane are in alignment;

 If you use the turnstile outdoor, it need to add a 100-200mm cement platform

for the turnstile to do damp proof, also need to add a canopy to protect the

turnstile from sun and rain;

 Please keep the control button or remote control far away from the children;

 Please don’t use the turnstile under the thunder and lightning condition to get

rid of damage to the equipment.

3 Board and parameter instruction


3.1 Board instruction

16
Main board

The connect board


Port Instruction mark
1 +24V Connect to 24V DC power
(1) PWR INPUT 24VDC power supply
2 GND supply
3 BAT+ Connect the 12V battery,
(2) BAT INPUT 12V battery input port Auto normally open when
4 GND
power off.
5 +12V Output for indicator of
(3) Entry 6 GND master machine Connect to indicator of
Indicator1 7 D1 D1 for enter direction master machine
8 D2 D2 for exit direction
(4) Man 9 Man Short for normally open ,
Normally open input
Gnd 10 Gnd Close immediately when
Fire alarm input
Sec 11 Sec cancel
12 SW1 Connect to access device
(5) Auto SW1 Enter open signal input
13 Gnd NO-SW1 COM-Gnd
14 SW2 Connect to access device
(6) Auto SW2 Exit open signal input
15 Gnd NO-SW1 COM-Gnd
17
16 A+
(7) COM1(485) RS485 communication Protocol docking
17 B-
18 R Negative of LED red
19 G Negative of LED green
(8) RGB LED Connect to LED bar
20 B Negative of LED blue
21 +12V +12V for LED bar
22 1-1 left sensor Connect to position sensor
23 1-2 Close sensor of core in the master
(9) POS Sensor1 24 1-3 Right sensor machine, flap /slide gate
25 +12V only use two sensor(open
12V output for sensor
26 GND and close)
27 IR1 Enter infrared sensor
Control board alarm when
28 IR2 Pinch infrared sensor
(10) IR sensor be block
29 IR3 Exit infrared sensor
Sensor
30 +12V
12V output for infrared
31 GND
32 D2 Output for indicator of
(11) N1 33 D1 master machine Connect to indicator of
Entry 34 GND D1 for enter direction master machine
Indicator 2 35 +12V D2 for exit direction
36 2-1 left sensor Connect to position sensor
37 2-2 Close sensor of core in the master
38 2-3 Right sensor machine, flap /slide gate
POS Sensor2 39 +12V only use two sensor(open
12V output for sensor
40 GND and close)
41 C1
42 C2
Reader reserve a place
43 C3
44 C4
(12) N2
45 R Negative of LED red
46 G Negative of LED green
Connect to LED bar
47 B Negative of LED blue
48 +12V +12V for LED bar
(13) M1 49 GND Motor output for mater Connect to motor of master
output 50 +24V machie machine
(14) M2 51 GND Connect to motor of vice
Motor output for vice machie
output 52 +24V machine

3.2 Wiring diagram

Flap/Slide gate wiring diagram

18
3.3 Parameter instruction

Description: the factory has been set up parameters, please do not modify, if

you need to modify the parameters, please proceed under technical guidance.

19
一、1. Description

1) The display screen is refers to the main control board of 3 LED display

from left to right. Four buttons: up and down for switch, ENT for sub-menu, ESC

for previous menu. Long press "ENT " 3 seconds unlock into the menu.Select

advanced parameters, and long press "ENT + Down " 3 seconds unlock into the

menu.

2.Menu setting
Item Explain
1. Parameters
1.1 Counter Display pass through count
Set Gate Mode(NO, NC and card, free or reject) of enter and exit
1.NC both Rej 2 .NC both free 3.NC both card (default)
4 NC Card Free 5 .NC Card Rej 6. NC Free card
1.2 Gate Mode
7.NC Free Rej 8.NC Rej Free 9.NC Rej Card
10.NO Both Free 11.NO Both Card
12.NO Card Free 13.NO Free Card
1.3 PassTimeout Set maximum waiting time 10-255, unit 0.1s, (default 5seconds)
Set Scan Card With Memory Mode
1.4 Memory
0 two-way disable(default),1. enter allow,2. exit allow,3. two-way allow
Set Can Scan Card After Entry Lane,Please do not modify
1.5 ReadIn Lane
1. disable (default), 2. allow
1.6 Open Delay Set Authorized Open Door Delay 0-255, unit 0.1s, (default 0)
1.7 CLS. Delay Set Close Door Delay After Passage Finish0-255, unit0.1s, (default 0)
1.8 Motor1 SPD. Set master Motor basic speed 1-100
1.9 Motor2 SPD. Set vice motor basic speed 1-100
1.10 Pass End Set IR Check passage end position 1. exit (default), 1 safety
1.11 Intrude Set Set Intrude Alarm Mode 1.no alarm, 2 .alarm (default), 3. alarm and close
Set Passage From Reverse Alarm Mode
1.12 Reverse Set.
1 no alarm, 2. alarm, 3 alarm and close (default),
Set Tail-Gating Alarm Mode 1 no alarm, 2. alarm, 3 alarm and close
1.13 Tail-Gating
(default),
1.14 Adv. Param.
20
.1 EN_O_SPD.1 Set Motor 1 Speed when Open Door for Entry
.2 EN_C_SPD.1 Set Motor 2 Speed when Open Door for Entry
.3 EX_O_SPD.1 Set Motor 1 Speed when Close Door for Entry
.4 EX_C_SPD.1 Set Motor 2 Speed when Close Door for Entry
.5 EN_O_SPD.2 Set Motor 1 Speed when Open Door for Exit
.6 EN_C_SPD.2 Set Motor 2 Speed when Open Door for Exit
.7 EX_O_SPD.2 Set Motor 1 Speed when Close Door for Exit
.8 EX_C_SPD.2 Set Motor 2 Speed when Close Door for Exit
.9 Save Fact. Save the current parameter to factory default
Set add relay use for passed counter
.10 Relay Mode
1. disable,(default),2.Enter allow, 3.Exit allow ,4. both ballow
Set automatic report gate status when on change 1 disable (default), 2
.11 Auto Report
allow
.12 NO Direction Set the normally open the gate opening direction , the default enter
Set the normally open the gate opening direction when Power failure , the
.13 Power Lost
default enter
.14 Barriers signal or double machine work 1 double (default) , 2 signal
.15 IR Speed Set IR Sensor Sensitivity(1-100) 0-100(default 100)
.15 IR Type Set infrared sensor type 1 PNP (default), 2 NPN
.16 IR Logic Set Use Local IR Sensor Logic
.17 Motor Pro. Set the motor over current protection threshold, the default 2.5A
.18 Self Check Set use self check when power on, disabled by default
.19 LED Mode Set LED indicator default parameter 1 Static LED,2 Square LED
.20 Set DevType Set Controller Device Type 1 Tripod 2 Flap gate, 3 Swing gate
2. System Set
2.1 Language Set Menu Display Language
2.2 Device Type Display Controller Device Type
2.3 Version Display hardware and firmware version information
2.4 Set Address Set Device Logic Address
2.5 RS485 Baud Set the baud rate of the RS485
2.6 Reset Reset all setting to factory default.
2.7 Restart Restart controller
3. Factory Test
3.1 Cycle Test Open and close door cycle test
3.2 Input Check Check input interface status
3.3 Output Test Output interface test

21
4 Trouble shooting and maintenance
4.1 Trouble shooting

123456789
Control board

ESC ENT

The box of control is buckle type ,It can open the upper cover of the buckle

from the side.

Fault 1: Gate automatically open when people in to first sensor?

Answer:Change pass mode two way free to two way card in the menu.

Fault 2: swipe into the first sensor, Gate give alarm and close immediately?

Answer:This means that the signal connection is opposite, exchange the open

signal connect terminal of SW1 Gnd to SW2 Gnd.

Fault 3: indicator light is not bright?

Answer:Take the other indicator or control board from other lane and check it

Fault 4: is there an indicator that shows the wrong direction?

Answer:Exchange the connect wire of indicator D1 to D2.

Fault 5: One side of the wing door does not work?

Answer:1)Check whether the connection wires is loose;2)Turn off the power

and use the millimeter to check whether the connection between the master
22
machine and the vice machine is continuous ;3)Measure whether M1 or M2 has

voltage output when restarting the power supply;4)Check fuse in the board.

Fault 6: open and close obvious non synchronization?

Answer:1)Check whether the POS Sensor connect wires are loose;2)Turn

off the power and use the millimeter to check whether the connection between the

master machine and the vice machine is continuous.

Fault 7: Motor idling?

Answer:1)Check whether the POS Sensor connect wires are loose;2)Turn

off the power and use the millimeter to check whether the connection between the

master machine and the vice machine is continuous.3)Check the vice board

12VGND for voltage output

Fault 8: there is one side of barrier is not closed?

Answer:1)Check whether the POS Sensor connect wires are loose;2)Turn off the

power and use the millimeter to check whether the connection between the

master machine and the vice machine is continuous.3)Check the vice board

12VGND for voltage output

Fault 9: swing the side of the pendulum rod can only open 90 degrees, or

open the side of the pendulum rod hit the box?

Answer:1) check the abnormal barrier and the normal one whether there is

any difference between the fixed angles and whether the pendulum rod is struck

or not 2)Check the iron sheet of core whether is loose, if loose readjust it.

Fault 10: The swing gate move slowly or shake or give big noisy?

Answer:Check core

23
4.2 Maintenance

Swing /falp barrier gates require regular maintenance by professionals and

daily cleaning to ensure long-term stability and extended equipment life.

1. Maintenance Content:

* Keep the turnstile housing and card reader panels of turnstile gates clean;

* Fasten and lubricate the internal movement structure;

* Check the dust of the driver board and make it cleans.

* Check the connectors and wiring points to ensure the reliability of the

connection.

2 Maintenance Methods:

1. Cleaning: Check the housing and card reader panels of the gate, and remove the

dust and other dirt to make them clean;

2. Rust removal and Lubrication: Check the movement of the flap /slide gate and

swing gate, remove rust with sand paper and spread with anti-rust oil if corroded;

3. Screws fastening: Check the connection of the various moving parts, fasten the

screws where they are loose to avoid causing fault for long-running;

4. Circuit board cleaning: Cut off the power, and wipe dust of the board by using

a clean brush;

5. Lines Checking: Check the connecting lines and solder reinforcement if they

are loose off.

Note: This product is the strong professional technical equipment. In addition to

daily maintenance, please do not feel free to disassemble it. If a fault occurs while

running, Please notify our service departments or the authorized service agencies

promptly to have it maintained. Do not disassemble it at random to avoid


24
damaging the internal structure or even damaging your interests because of your

improper operation.

Guarantee Instruction

Our company products are guaranteed for one year, from date of sale,

providing free maintenance based on not being damaged by any man-made.

● During the warranty period, all faults caused by the product itself can be

maintained for free. Please carry the filled warranty card and the purchase invoice

to the authorized service centers across the country or return the machine to our

company for free repair.

● Within the period of free maintenance, faults or damages caused by man-made

or natural disasters can be maintained with additional charge.

● Over the period of free maintenance, faults or damages can be maintained with

additional charge.

The following conditions are not under warranty:

● Damages caused by abnormal operation, man-made or natural disasters;

● Damages after disassembling any portion of the machine (lines, components

etc.) ;

● Damages caused by wrong guide of non-professional technicians;

● Damages caused by adding other functions with unauthorized modification or

installation with other equipment.

Note: The warranty card and purchase invoice are used as warranty certificates

to maintain the machine. Please reserve them carefully. Lose won’t repair.

25
User Data Card

User Name User Contact Postcode

User Address

Machine

Model

Seller Unit Seller Contact Postcode

Seller Address

Sell Date

Maintenance Records

Maintenance Fault Description Maintenance Maintenance Maintenance Unit

Date Method Man Seal

26
#24, Shambavi Building, 23rd Main, Marenahalli, JP Nagar 2nd Phase, Bengaluru - 560078
Phone : 91-8026090500 | Email : sales@esslsecurity.com
www.esslsecurity.com