BQJVPA

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Vertical mixed flow pumps 800−BQJV

Application Informatory performance data


Pumps of Series 800−BQJV provided with the discharge branch Pump rated capacity ........................................ Qn 1,220 I.s.−1
of diameter 800 mm is the one of mixed flow pumps Series of Pump rated specific energy ............................. Yn 82 J.kg −1
vertical workmanship with progressive constructional features. Pump speed .................................................... n 590 min −1
That workmanship may cope with peak parameters and operat− Density of a pumped liquid ............................. 1,000 kg.m−3
ing demands in fields of conventional and nuclear power indu− Discharge branch diameter ............................. DN 800 mm
stries, metallurgy, industry, water management and agriculture. Pump weight without a drive
In general, that pump is intended for pumping cooling water in with face−to−face dimension of 3,950 mm ...... m 6,000 kg
thermal power stations and nuclear ones and technological pro− Face−to−face dimension may be modified according to a pump−
cesses of some industrial branches, further, for re−pumping ing station arrangement.
surface river water in irrigation and drainage services, as well as
Pump regulation range through adjusted positions of the pre−
for pumping potable and service water in water supply plants
fixed diffuser vanes changes may be ensured from 0.7 to 1.15 Qn.
up to temperature 50 °C and max. acidity 6 pH.
Pump 800−BQJV is advantageous for its continuous control of
specific energy and the pump capacity that may be realized
within operation with slight turning of pre−fixed vanes being
mounted in front of an impeller entry. Pump control within its
operation allows its continuous running in optimum conditions.
Pump efficiency has increased as well as economy of operation
within various operational modes due to different performance
parameters.

Construction
Pump 800−BQJV is of vertical single−stage type, with a mixed
flow impeller.
Pump rotor consists of an open mixed flow impeller mounted
on the shaft cylindrical end and locked with a nut. Rotor is
supported on two bearings. Lower bearing with rubber lining is
lubricated with a pumped liquid, upper thrust rolling−contact
bearing is oil−lubricated. In journal bearing and in a seal there
the shaft is protected with replaceable sleeves.
Pump stator consists of a suction bell, pre−fixed diffuser, suc−
tion reducer, diffuser and branch elbow. Branch elbow is situat−
ed under the pump suspension bed plate. In the suspension
bed plate there is the seal space accessible through two holes
being provided in the jacket.
Pre−fixed diffuser − it is an equipment modifying flow of a pump−
ed liquid even before its entry into the impeller. With the pre−
fixed diffuser vanes reasonable adjusting there flow direction
of a liquid streaming to the impeller may be changed and thus
specific energy value and a pumped liquid through−flow chan−
ge is ensured even within the pump operation.
Regulating mechanism is controlled by an electrical servomo−
tor of „MODACT“ type. Regulating force is transmitted through
a motion screw and a regulating ring with the aid of a lever
mechanism onto the pre−fixed diffuser vanes. Regulating devi−
ce is equipped with limit switches and quick−break ones al−
lowing remote control.
Vertical mixed flow pumps 800−BQJV

Pump dimensions

560

915
355
800

1870x1300
DN 800; PN 6

640

2020
MIN. 900

3950
600

840
410
250 430

∅1125
550

Informatory selection chart


Y [J.kg−1] n= 590 min−1
150

100

50 +40°

−50°

0
500 600 700 800 900 1000 1100 1200 1300 1400 1500
Q [I.s−1]

You might also like