Trouble Shooting
Information No. TSI050712
GB

You are kindly requested to replace the following parts on machines equipped with Harvard-
Filter AN 279994002 :

1. Gauge AN 462833, instead of gauge AN 402845; the red indication for filter change
Is now 4 bar.

2. Pressure Limiting Valve (PLV) AN 413501, instead of PLV AN 286940007; now 5 bar
instead of 7 bar; the actual 7 bar PLV can be set to 5 bar by mounting a new spring (AN
065480005/red-yellow).

Please see therefore extract of diagram KS 445751 A.

TSI050712_GB.doc
(53 KB)

Machines produced starting of 07/2005, will be equipped with the new version.

Please check the filters within the next 3 up to 6 months and adjust the pressure setting.