1) Operating temperature range, see 2 outputs. Other input and outputs combination on demand. How to read our product code:
Case on all models in the table: 10TE Example PSC100A24
PSC100 = Family code
A = input voltage code A
24 = Output voltage 24 V
U1 + 4 U1 + 4
U1 + 6 U1 + 6
(S+) 8 (S+) 8
(S-) 10 (S-) 10
12 12
U1- U1-
U1- 14 U1- 14
16 U2+ 16
18 Common 0 18
20 U3- 20
Alarm 22 Alarm 22
NC 24 NC 24
Inhibit 26 Inhibit 26
DCin+ 28 DCin+ 28
DCin- 30 DCin- 30
32 32
Page 2
TWO AND THREE OUTPUTS 100 TO 150 W
FEATURES
• Master Outputs from 5 to 48 V • Convection cooled
• One auxiliary voltage 5 to 30 V • Low voltage alarm, open collector
• Second auxiliary voltage 5 to 15 V • Inhibit / Power Down input
• Operating temperature range • Conformal coating, Tropic
-25 to +55 °C. +70 °C with derating • Compatible AC input models.
• Fully encapsulated meets IP30 Please ask for PSC-AC datasheet.
Page 3
AUXILIARY OUTPUTS FEATURES
Master - Slave Under voltage logic alarm
The PSC-series uses a master slave configuration on the On DC-inputs a built in logic alarm changes to alarm state
auxiliary outputs. The main power circuit is regulated by if the converter output voltage drops 10 % below nomi-
the master output. The auxiliary circuits use step down nal output. The DC OK LED is also controlled by the alarm
regulators. The advantage is high efficiency in all parts circuit. The alarm has an open collector configuration.
and we can supply continuosly 1.2 A on each of the auxil- A voltage < 1 V is normal operating condition. In alarm
iary voltages. On special demand we can supply units with state the output can drive max 20 mA 60 V. The logic
higher continuous auxiliary voltage. The disadvantage is alarm works if a voltage is applied through a resistor on
that the master output need to take minimum 1/3 of the the collector output max voltage 60 V.
total load and do not supply any current if the master is For relay output, see option B.
unloaded.
H15
PIN
12, 14 0V, MASTER 0
UL-alarm
circuit 470 to12
22
ALARM
INHIBIT
26 +5 to 24V
30 -DCIN
Conformal coating
The PSC-series is conformally coated to withstand non-
If the input voltage range is limited to handle a specific condensing tropical environment Rh 95 %.
battery voltage the auxilliary continous current can be
increased to 2.5 A, please contact factory or your local
contact.
Page 4
OPTIONAL FEATURES
Overvoltage protection OVP-A Input diode for reverse voltage protection - K
The output voltage is limited to 15 % over nominal out- Parallel diode reverse protection is a standard feature.
put voltage. A SCR short-circuits the output. It is reset by K1. Reverse protection with a series diode on the input.
switching off the input or by an inhibit signal. The OVP The input voltage range is affected with 1 V higher start/
circuit is a standard feature on 5 V outputs, which triggers stop voltage. On A and B this option derates the output
at 6.2 V. power by the increased heat losses produced by such
diode. Contact factory for details.
Undervoltage alarm with relay -B K2. Addition of a glass fuse. Can not be used on higher
The logic alarm is replaced by inputs than 180 Vd.c.
a dual relay NO/NC (Normally 2.5 kVa.c. isolation Input/case -E1
Open) in alarm state. (Alarm On 24 and 48 inputs.
state = no input or low out-
put), see figure. 2.5 kVa.c. isolation Output/case -E2
The relay rating is 30 V 0.5 A Euro panel -L, 10, 12 or 14TE see figure 8
(a.c. & d.c.). Other ratings on
demand. Wall mounting panels -N, see figure 9 & 10
Includes H15 connector holder. The female
This option is only available on single output models. connector has to be added. To mount on a DIN
TS-35 rail, we can supply an optional DIN rail clips.
The cable rating is AWG16 or < 1.5 mm2. That makes it not usable for
A-input and 5 V outputs.
DIN-rail Clips
Page 5
GENERAL DATA / INPUT DATA OUTPUT DATA
LABEL VALUE LABEL VALUE
Design topology Push-Pull Source regulation 0.2 %
Switching frequency 50 kHz Load regulation (0 to 100 % load) master 0.2 %
Emission / Immunity See page 8 Cross regulation 25 to 100 % load step
Max. accepted input ripple on master 0.2 %
50-400 Hz 1 % of nominal voltage Secondary regulation 0 to 100 % 2%
Power consumption at no load 3 to 5 W Transient recovery time for load step 10 < 2 ms
to 100 % voltage deviation 3%
Reverse input voltage protection Parallel diode
Output ripple (50 kHz)1 10 mV p-p
Inrush current limit
Input ripple attenuation to output
A, B, CT input code No
(50 to 400 Hz) 150:1
C input code Optional NTC
Emission / Immunity See page 8
D, E input code Yes with NTC
Temperature coefficient 0.02 %/°C
Insulation See page 8
Min output adjustment range
Fire Protection EN 45545-2 HL 3 “Non listed product” adjustable with a 15 turn potentiometer 90 - 110 %
level 4.3.2 rule 1 and figure 1 < 100 g
Current limit, rectangular. 105 %
Dimensions See below
Remote sense Option S
Weight See below
Soft start Yes
Isolation output / case See page 8
d (TE) 10 12 Efficiency2 80 - 91 %
Weight incl. connector (kg) 1.2 1.3 Storage temperature range -40 to +85 °C
N-option for wall, chassis and N-option, fixed against external cooler. L-option 10TE, 12TE, 14TE
DIN rail mount The spacers hold the H15 connector
Page 6
104.4 mm
MECHANICAL DRAWING
104.4 mm
16 100 mm
100 mm
mm
7
20.5 mm 2TE
57 mm 2TE
48 mm 9TE
9TE
Figure 6. Front and connector side Figure 7. Front and connector side Figure 8. Front panel
of PSC100 of PSC150 3HE option L
6x4.2 mm
The PSC-family are built in a tubular aluminium extrusion, with high thermal conductance which also work as a good
EMC shield. The mechanical design permits use in vehicles and heavy industrial environments. The IP class is IP30. On
49 mm
Vibration and shock resistance is high in standard DIN 431605: 6 g 10 ms (5000 times in 3 directions)
49 mm
172 mm
190 mm
13 mm
53 mm 10TE
63 mm 12TE
200 mm
14 mm
211.5 mm
Page 7
CE MARK SAFETY STANDARD EN/IEC 60950
PSC-series meets the requirements defined by CE mark as ISOLATION TESTABLE LEVELS TEST VOLTAGE
apparatus.
Input / Output: Input code: A, B, CT 2 kVd.c.
PSC-series meets requirements of EMC directive and low Input code: C, D, E 2.5 kVa.c. / 4 kVd.c.
voltage directive (LVD) and RoHS II directive. Input / Case: Input code: A, B, CT 2 kVd.c.
Input code: C, D, E 2.5 kVa.c. / 4 kVd.c.
The PSC-series family is in respect to EMC, a stand alone
Output / Case all outputs 2 kVd.c.
unit that can also be installed in any other environment by
Master Output / Auxiliary Outputs 2 kVd.c.
a professional installer.
Alarm / Input: Input code: A, B, CT 2 kVd.c.
Please note that product standards can demand different Input code: C, D, E 2.5 kVa.c. / 4 kVd.c.
levels or other basic standard tests. We test according to
ISOLATION TESTABLE LEVELS SAFETY ISOLATION
levels below. For higher levels or other tests, contact
Transformer isolation In / Out:
factory
Input code: A, B, CT 2 kVd.c.
Input code: C, D, E 4 kVa.c. / 8 mm
Installation Class I
EMC
EMC STANDARDS EMC PERFORMANCE REMARKS
Emission standards EN IEC 61000-6-3 Commercial and light-industrial environments
Input Output
EN 55016 CISPR 16 (0.15-30 MHz) OK OK opt.EN 55022 level B
EN 55016 CISPR 16 (30-1000 MHz) OK Enclosure test