FM SERIES

6-FM-100 12V 100Ah

236
211
208
174
41.5
311.5
407

■ Specifications ■ Discharge Curves 77℉(25℃)


Nominal Voltage 12V
Rated Capacity(20 hour rate) 100Ah

Total Height Terminalv oltage (V) 13.0


9.29inches (236mm)
(with terminals) 12.0

8.19inches (208mm) 11.0


Height
0.05C
0.05C
Length 16.02inches (407mm) 10.0 0.16C 0.09C
0.16C 0.092C
1C
1C 0.59C
0.56C
Width 6.85inches (174mm) 9.0 3C
3C

Weight Approx.72.6pound(33.0kg) 8.0

■ Characteristics
20 hour rate (5.0A) 100Ah Discharge time
10 hour rate (9.20A) 92Ah
Capacity
77 oF(25oC) 5 hour rate (16.0A) 80Ah
1 hour rate (60.0A) 60Ah
15 minute Rate(164A) 41Ah ■ Relationship between charge voltage
and temperature
Internal Resistance Full charged Battery 77 F(25 C)
o o
5mΩ
(V/CELL)
(V/12V)

104 F(40 C)
o o
102%
(V/6V)

Capacity affected by 77oF(25oC) 100%


Temperature (20 hour rate) 32 F(0 C)
o o
85%
7.8 15.6
5oF(-15oC) 65%
Capacityafter 3 month storage CYC
91% 7.5 15.0 LE U
Self-Discharge SE
o o Capacityafter 6 month storage 81%
77 F(20 C) 7.2 14.4
Capacityafter 12 month storage 60% STAND
BY US
6.9 13.8 E
Max. Discharge
Current 77 F(25 C)
o o 800A(5S)
6.6 13.2
Terminal M3
Initial Charging Current less than 30A -10 0 10 20 30 40 50 60
Charge Cycle
Voltage 14.4~14.7V/77oF(25 oC)
(ConstantVoltage)
Float Voltage 13.5~13.8V/77 F(25 C)
o o
Ambient temperature (℃)

■ Constant Current Discharge (AMPERES @25℃)


F.V/Time 10Min 15Min 30Min 60Min 2H 3H 4H 5H 8H 10H 20H
1.60 226 164 106 63.4 36.9 25.8 20.6 17.7 12.1 9.90 5.17
1.65 217 158 102 61.0 35.5 25.5 20.4 17.5 12.0 9.80 5.12
1.70 205 151 86.8 60.5 34.6 25.0 19.9 16.9 11.9 9.59 5.06
1.75 180 142 81.5 60.0 34.3 24.5 19.3 16.0 11.6 9.20 5.00
1.80 173 137 78.4 57.7 33.0 23.6 18.5 15.4 11.2 8.85 4.81
1.85 142 119 72.1 53.1 31.7 22.4 17.6 14.6 10.6 8.41 4.57

■ Constant Power Discharge (WATTS PER CELL@25℃)


F.V/Time 10Min 15Min 30Min 60Min 2H 3H 4H 5H 8H 10H 20H
1.60 394 307 191 119 70.0 49.1 38.7 32.4 22.9 18.3 9.73
1.65 389 304 185 115 69.1 49.0 38.6 32.2 22.8 18.2 9.72
1.70 379 291 162 111 68.4 47.7 37.7 31.6 22.3 18.1 9.68
1.75 346 274 156 108 67.9 46.4 36.8 31.0 21.7 18.0 9.67
1.80 330 264 151 107 66.6 46.1 36.4 30.5 21.4 17.7 9.65
1.85 273 231 141 104 64.2 45.0 35.4 29.6 20.1 16.9 9.14

www.ensmartpower.com
FM SERIES
6-FM-100 12V 100Ah
The operating environment temperature above 40℃ should be avoided, After long term storage, The battery actual capacity would
be less than the rated capacity. Full capacity will be obtained through several charge/discharge cycles.
To get the longest life, ENSMART battery should be fully charged before storage.

■ Cycle service life in relation to depth of discharge ■ Constant voltage charge characteristic

Volume

Voltage
Charged

Current
(%) (×CA) (V) (0.25CA,25℃)
140

120 0.25
Capacity (%)

15.0 CHARGED VOLUME


100 0.20
14.0 CHARGE VOLTAGE
100% D.O.D
100% D.O.D 50% D.O.D
50% D.O.D
30% D.O.D
30% D.O.D 80
0.15
13.0
60
0.10
40 12.0

0.05
20 11.0 CHARGE CURRENT

0 0
0 2 4 6 8 10 12 14 16 18 20
Number of cycles Charge time(hours)

■ Self-Discharge Characteristics ■ Relationship of OCV and Residual Capacity %(25℃)

0℃
(32℉)
Residual Capacity (%)

5℃
(41℉)
Capacity (%)

10℃
(50℉)

40℃ 30℃ 20℃


(104℉) (86℉) (68℉)

Storage Time (Months) Capacity (25℃)

■ Temperature effects on capacity ■ Temperature effects float life


Capacity (%)

Life (Years)

CA: Rated Capacity at 25℃

Temperature
Temperature

United Kingdom Turkey China


Ensmart Power Ltd. Ensmart Güç Kaynakları ve Enerji Depolama Ensmart Power (Shenzhen) Co.,Ltd.
Kemp House 160 City Road, Sistemleri San. ve Tic. A.Ş. 218E24#, Bldg.3, Zone 30, No.2,
London, UK EC1V 2NX, GB Halk Cad. Palladium Office, No:8/A3, Atasehir, Kefa Rd., Hi-tech. Park,
+ 44 20 3808 85 60 Istanbul, Turkey 34752, TR Yuehai St., Nanshan, Shenzhen, China
sales@ensmartpower.com +90 216 225 84 66 +86 13420986759