Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 6

Product Release Issue A

Checklist CMC Type A 2 April 2013


Base cabinet excluding Misc. support cabinet, Power and Battery Modules p1

CUSTOMER Fibre box (front) RRH DCD (rear) Bias-T GPS unit

EXPECTED VOLUME
Filter

REQUESTED DELIVERY

RRH modules

Power Module

Note:
Typical configuration
shown. Number of
RRH modules and
other details may
vary.

Battery Module Misc Support


Base Frame Cabinet
NOTES
Product Release Issue A
Checklist CMC Type A 2 April 2013
Base cabinet excluding Misc. support cabinet, Power and Battery Modules p2

Refer to separate checklists for Power Module, Battery Module and Miscellaneous Support Module.

AC Distribution - Refer to Power Module PRC


Batteries – Refer to Battery Module PRC
General monitoring and control – Refer to Power Module PRC
Alarm outputs – Refer to Misc Support PRC
Product Release Issue A
Checklist CMC Type A 2 April 2013
Base cabinet excluding Misc. support cabinet, Power and Battery Modules p3

No. Item Customer Acceptance Criteria Compliant Comment


yes
x no
1 Conn Cable entry options are bottom entry or rear entry.
2 Conn The rear entry option includes glands for up to 14 x 13mm to 16mm diameter cables per
panel
3 Dist The cabinet includes a DC distribution module providing power to the RRH modules..
4 Dist The DC distribution module includes provision for up to 12 x 10A MCBs.
5 Dist The cabinet includes a DC common bar with 2 rows of 16 studs.
6 Dist The cabinet has an AC earth bar with two studs.
7 Docs The cabinet is provided with an Electrical Declaration of Conformity.
8 Docs An installation guide is provided, with:
 Mounting details
 Wiring diagrams
 Commissioning procedure
 Maintenance procedures
9 Docs Site documents are provided. Drawings, wiring diagrams, etc.
10 Docs The cabinet has storage for A4 documents In the Misc. Support Cabinet.
11 Env The cabinet can accommodate up to 9 RRH units running at full power.
12 Env The cabinet can operate with a relative humidity between 5 to 90%, absolute humidity
<25 g/m3.
13 Env The cabinet shall withstand a wind loading of 40m/s in any direction without visible It is not recommended to remove the side
damage with side panels fitted. (30m/s with side panels removed). panels in high winds.

14 Env Internal equipment is protected to IP23. Power Module and Misc. Support Cabinet
are IP55.
Product Release Issue A
Checklist CMC Type A 2 April 2013
Base cabinet excluding Misc. support cabinet, Power and Battery Modules p4

No. Item Customer Acceptance Criteria Compliant Comment


yes
x no
15 Maint These components can be replaced in the field without any interruption of service:
 Roof
 Exterior panels
 Mullions
 Side Panel
 Battery Module
16 Maint The main cabinet requires the following check on a yearly basis: See also Misc. Support Cabinet and Power
 Air intakes clear Module – check fans are running.

17 Mec Dimensions:
 1790 mm high excluding base frame
 600 mm deep
 2310 mm wide
18 Mec The cabinet has colour options to suit RMA conditions, normally Ghost Grey or Green
Fields.
19 Mec Cabinets are supplied with anti-graffiti paint as standard. Graffiti can be easily washed off.
20 Mec There are no externally operated screws or bolts. Exception: The access cover for the
generator plug and cord.
21 Mec The cabinet is constructed of materials that are resistant to corrosion for the design life of Marine grade aluminium (internal and
the product. external), zinc-plated steel (internal),
Galvanised steel base frame.
22 Mec The cabinet has a design life of 15 years.

23 Mec There are no special tools or other requirements for installation.

24 Mec-door A door alarm is provided and activates if any side panel is removed. Excludes narrow side panels as below.
25 Mec-door The side panels are fitted with swing handle three-point locks. Panels lift off after operating the lock
handle.
26 Mec-door The narrow side panels have four point locks, operated by two levers from inside.
Product Release Issue A
Checklist CMC Type A 2 April 2013
Base cabinet excluding Misc. support cabinet, Power and Battery Modules p5

No. Item Customer Acceptance Criteria Compliant Comment


yes
x no
27 Mec-door The locks are single euro profile with a replaceable barrel.
28 Mec-door The key cannot be removed while the lock is unlocked.

29 Eqpt The CMC includes as standard: The Power Module, Battery Module and
 1 x Power Module Misc Support Cabinet are specified
 1 Battery Module separately.
 1 x Misc Support Cabinet
30 Eqpt Up to 9 sets of the following may be fitted:
 RRH
 Filter
 Bias T
31 Eqpt A second battery module may be fitted as an option, at the expense of four RRHs.
32 Eqpt The cabinet has an option to include mounting and a window for a GPS unit in the roof.
33 Eqpt There is provision for an AC power meter to be fitted. A clear plastic viewing window and internal
compartment are included. There is no
meter wiring as standard.
34 Mec-install The cabinet may be safely lifted by crane during installation using two removable lifting The bars are available to separate order.
bars.
35 Mec-install The cabinet should be lifted with no RRHs or batteries fitted. There may be up to 30kg of equipment in
the Misc. Support Cabinet.
36 Base A locking point is provided to allow a portable external generator (or other equipment) to “D” ring on the front of the base frame.
be secured to the cabinet base frame (when provided).
37 Base The base frame designs include provision for an earth cable to run from an external earth
stake into the cabinet through the bottom.
38 Base The base frame is constructed of materials that are resistant to damage and corrosion Hot dipped galvanized steel
39 Transport The cabinet is suitable for long term storage in a “weather protected non-temperature
controlled location. (ETSI 300 019-1-1).
40 Transport The cabinet is shipped with Power Modules, Battery Modules and Misc Support Cabinet
fully installed and wired.
Product Release Issue A
Checklist CMC Type A 2 April 2013
Base cabinet excluding Misc. support cabinet, Power and Battery Modules p6

No. Item Customer Acceptance Criteria Compliant Comment


yes
x no
41 Transport Bias-T brackets, filter brackets and RRH mounts are not installed. They are supplied These are packed and retained to avoid
loose as a kit. damage and movement during transport.
42 Transport Storage temperature range is -25°C to +55°C.