Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

Vertical Separator

Given data:
steam(kg/h)
water (kg/h)
operating pressure (bar)
Holdup time (min)

Data from steam table at 4 bar


saturation temperature (Deg C)
liquid density (kg/h)
vapour density (kg/h)

Settling velocity, ut: 0.07[(pL-pv)/pv]^0.5


Required Dia, Dv: [(4*vapour volumetric flow rate)/(pi*u t)]^0.5
where, pL (kg/m3)
pv (kg/m3)

if demister is not used: ut*0.15 (considering MOS and flow surges)


tical Separator

Given data:
2000
1000
4
10

steam table at 4 bar


143.6
926.4
2.16

926.4
2.16

ut (m/s) 1.44967429292085
demister is not used, ut (m/s) 0.217451143938127

vapour volumetric flow rate (m3/h) 0.257201646090535


Liquid volumetric flow rate (m3/h) 0.0002998464786

Dv (m) 1.22749913613846

volume held in vessel 0.179907887161773


Required depth 0.152103131770192
For allowing space for positioning the level controller 0.304206263540385