Professional Documents
Culture Documents
VSD 261 P
VSD 261 P
VSD 261 P
Read this Manual carefully before installation and keep it by hand for future reference.
z Persons without technical qualifications should not attempt to operate this dome device before reading this Manual
thoroughly.
z Remove any power to the dome before attempting any operations or adjustments inside the dome cover to avoid
z Inside the dome cover there are precision optical and electrical devices. Heavy pressure, shock and other sudden
adjustments or operations should be avoided. Otherwise, you may cause irreparable damage to the product.
z Please DO NOT remove or disassemble any internal parts of the video camera to avoid normal operation and possibly
void the warranty. There are no serviceable parts inside the camera.
z Please connect all the wires of the dome strictly accordingly to the specifications, It is highly recommended that the
proper lightning arrestors and surge suppressors are installed before the dome is entered into service.
z Please do not use the product under circumstances where the limits exceed the maximum specified temperature,
z Suggest using UPS or other stable power supply system to make sure camera system can work normally.
21
Please check the quantity of the package contents when open the carton.
Description Qty
BNC Wire 1
Rubber Cushion 1
Bag of screws 1
Camera Module 1
Wall bracket 1
AC24V transformer 1
Camera Shroud 1
Terminal 2
Please contact the distributors in time if the spare parts are missing.
21
z Highly efficient 3-dimensional scan function (User can change the pan scan tour when the dome is in manual scan or
z Zoom and dome speed correction function (When the zooming-in of the camera is disabled, the dome speed is reduced
2.1.1 Read this Manual and Intelligent Camera Operation Guideline before attempting installation or operation of
2.1.2 Power Supply: AC24V.The input voltage of the dome is indicated on the bottom of the dome device or on the
input position.
2.1.3 Inside the dome cover there are precision optical and electrical devices.
Heavy pressure, strong shaking and other sudden adjustment or operations should be avoided
during the transportation. Otherwise, you may cause irreparable damage to the product.
2.1.4 Please DO NOT remove or disassemble any internal parts of the video camera to avoid
2.1.5 During usage, user should abide by all electrical safety standards.
Use only the power supply specified by manufacturer. The control cable
2.1.6 Indoor dome is for indoor use only and not suitable for outdoor or
high humidity ratings. Use outdoor dome for high humility location or in the rain.
2.1.7 Please do not use the product under circumstances where the limits
2.1.8 Avoid pointing the camera directly to the sun or other extremely bright objects for prolonged period of time.
2.1.9 Cleaning agent of abrasion should not be used to clean the dome device.
2.1.11 Verify that the surface you are planning to use for attaching the dome
can adequately support the weight of the device and mounting hardware.
2.1.12 Should the lens of the camera become dirty, use special lens cleaning cloth and solution to properly clean it
Figure 1. Illustrates the Upper layer of the carton (top half), Figure 2. Illustrates the lower layer of the carton (bottom
half).
6
1
7
2
8
3
9
4
10
Fig 1 Fig 2
1 Manual, Certificate
2 BNC Wire
3 Rubber Cushion
5 Bag of Screws
7 Camera Module
8 Wall bracket
9 AC24V transformer
10 Camera Shroud
2.3.1 Ribbon cable:Insert FPC socket of the cable to the relevant port of the base plate on the dome control board.
(Ribbon cable length of 65MM and110MM, user can select the ribbon cable according to the different models of camera)
FP C
C on n e c to r
F FC
F l e xi bl e F l a t C a bl e
FP C
C on n e c to r
4 -PW M2 *6
Fig.3
FPC Socket
Fig.4
2.3.2 Install the camera module: Install the camera module on the vertical axis tray of the dome as illustrated in Fig. 6 and
Fig. 7. Attention: Take care not to scratch the lens when installing the camera. Do make sure the camera model is
the right one for installation. Secure the camera to the corresponding screw holes as illustrated in Fig. 6, according
to the model and make of the camera, as different camera models may have different dimensions. Following the
installation of the camera module verify that it does not touch any of the dome parts including the camera shroud
and acrylic dome by gently moving the camera module along the vertical axis.
Fig.8 illustrates the location of the 4 screw holes for the camera shroud (M3).
Fig.10 Fig.11
2.4.1 Position the open end of the camera shroud towards the camera lens as illustrated on Fig. 9. Align the 4 holes of the
shroud with the 4 holes on the core of the dome as illustrated in Fig. 10.
2.4.2 Utilizing the supplied (4) four M3*14 screws securely tighten the camera shroud in place, as illustrated in Fig. 11.
2.5 Bracket installation
2.5.1 Feed the BNC wiring harness through the channel inside the wall bracket as illustrated in Fig 12. Verify that
the channel remains empty before feeding the wiring harness
Fig.12 Fig.13
2.5.2 Affix the wall bracket to the wall using 4 M6 Expand screws as illustrated in Fig 13.
4-M8 ? 120.0
70.7
? 100.0
70.7
25.0
Pendent bracket
4-M6 200.0
260.0
Wall bracket 2-PM4*10
3-PM5*12
3-M5*8
Bracket adapter
Bracket adapter
2-PM5*14
252.1
252.1
OD housing 226.7
OD housing 226.7
Inner housing
Inner housing
Clear acrylic Clear acrylic
Camera 195.4
SR78.5
Camera SR78.5
195.4
Fig.14 Fig.15
4-M8
4-M8
76.0 50.0
96.0
100.0
Pole bracket
3-M5*8
Bracket adapter
2-PM5*14
252.1
226.7
OD housing
Inner housing
Clear acrylic
SR78.5
Camera
195.4
Fig.16
Fig.17
Fig.18
Fig. 19 is the illustration of the wiring diagram for the electrical connections to the dome unit.
Fig. 20 illustrates the supplied power Supply.
Yellow/green:Ground wire
BNC Connector:Video output
Orange:RS485+ Connect to keyboard
controller
Yellow:RS485-
Red, black : AC24V power Supply
Terminal:Connect to the dome device
Yellow/green:Ground wire
Fig.19
Connect to dome
Fig.20
User can understand the dome electric connection property and adjust, assemble, test and operate the device
on show with convenience. Please read the wiring illustration carefully for the first time use. Any wrong
connection may cause the permanent damage of the dome or other equipments.
Yellow/green:Ground wire
BNC Connector:Video output
Orange:RS485+ Connect to keyboard
controller
Yellow:RS485-
Red, black:AC24V power Supply
Terminal:Connect to the dome device
Yellow/green:Ground wire
Yellow/green:Ground wire
BNC Connector:Video output
Orange:RS485+ Connect to keyboard
controller
Yellow:RS485-
Red, black:AC24V power Supply
Terminal:Connect to the dome device
Yellow/green:Ground wire
Before installation and use the unique address for each dome and the communication protocol including
transmission speed (baud rate) should be set to correspond with the chosen control system.
3.2 Protocol and baud rate setting( Caution: This operation should be performed with the power OFF.)
ON
On/Off
On/Off
1st 2nd 3rd 4th 5th 6th
Protocol type
Kd6 ON ON ON ON ** **
CAUTION: The protocol and baud rate of dome device should match the settings of the controller. In order
to take effect the dome must be power cycled after each change.
10
3.3 Address setting of each dome (Caution: This operation should be performed with the power OFF).
Setting method: The sum of switch numbers when it is at ON position is the address of dome device.
Calculation example of dome device address: (2+4+16=22), the address is 22. Dome device range: 0~255
ON ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 128
2 64
4 32 2 4 16
8 16
Set the protocol, baud rate, and address of the keyboard controller to match the settings on the dome.
(For instruction of how to set the keyboard communication settings please refer to keyboard controller manual).
Attention: If the protocol setting of the dome is set to auto detection, the protocol of keyboard controller
can be set PELCO-D or PELCO-P arbitrarily. But its baud rate should be set identical with that of the
dome device.
When all of the above settings are completed you can start testing to dome functionality.
Up
joy s t ic k Zoom in
joy s tic k
Left Right
Rotating
Zoom out
Down
The operation of the dome and the direction(Up, down, Zoom control of the camera can be achieved by
left and right) of the camera can be controlled using rotating the knob on the joystick or by using TELE
the joystick of the keyboard controller, as illustrated (zoom in) and WIDE (zoom out) functions on the
above. keyboard controller as illustrated above.
Summary: The camera and the dome are basically normal. Summary: The dome device is basically normal.
11
Menu operation
To make a selection, move the joystick in the UP or DOWN direction. The on-screen arrow points to the selected
option.
Press OPEN or use the joystick to the Left or Right position you can change the value of your selection or enter
the submenu for the selected option.
Press CLOSE to exit menu or return to the previous menu.
Number
1. Joystick Left or Right to move the cursor under the desired numeral position.
4. Press OPEN to confirm the selection, and the selected number will show on the corresponding position.
5. Input other Characters accordingly.
6. Press CLOSE to finalize your selection and return to the previous menu level.
4.2 Main Menu 1. Select“90” on the preset position to enter the main
configuration menu for the dome.
Select“90”on the preset position to enter
2. To make a selection move the joystick in the Up or Down
The main configuration menu for the dome. direction. The on-screen arrow points to the selected option.
Press OPEN or move the joystick Left or Right you can
- - - - - - - - VSD - - - - - - - -
enter the submenu for the selected option or change the
→1.Language English
2. Display Options value of your selection.
3. Control Options Attention: The function of the button“OPEN” is IRIS
4. Diagnostic Options OPEN.
5. Camera Options
3. Press the button CLOSE on the keyboard controller to exit
6. Function Programming
menu or return to the previous menu.
IRIS CLOSE to Exit
Attention: The function of the button“CLOSE” is IRIS
CLOSE.
PreShot
1 - 165
1 - 165 001
001 ↑
↑ 0123456789
0123456789 ↑
IRIS CLOSE When Done IRIS CLOSE When Done
13
z Call PreShot
+
Stored
PreShot Name
Pan: 262.2 Tilt: 2.7 X8
1. Number 1
2. PreShot Setup
→3. Call PreShot Call PreShot on the menu:
4. Delete PreShot 1. Move the joystick Left or Right or press OPEN to enter Number Editing
5. Name _________ and select the desired PreShot Position.
IRIS CLOSE to Exit 2. Move the joystick Left or Right to move the cursor to edit the digit
number,
Press OPEN to confirm. Press CLOSE to finalize your selection and exit.
Delete PreShot
3. Move the cursor to select the Call PreShot Position.
4. Move the joystick Left or Right or press OPEN to call the PreShot
PreShot Name
Position.
1. Number 1
5. Press CLOSE to exit.
2. PreShot Setup
3. Call PreShot
→4. Delete PreShot
5. Name _________
Delete Preset Position on the menu:
IRIS CLOSE to Exit
1. Edit the number to be deleted (Refer to Number Input Instruction)
Note: Select the PreShot Position to be deleted.
2. Move the cursor to select the Deleted Position.
Are you sure to do this?
4. Move the joystick Left or Right to enter the deleting position.
IRIS OPEN to Confirm 5. Press OPEN when done. Press CLOSE to exit.
IRIS CLOSE to Cancel
14
0 1 2 3 4 5 6 7 8 9_
IRIS CLOSE When Done
z Sector Setup
Number
Sector Setup 1. Move the joystick Up or Down to move the cursor to select Sector
→1. Number 1 Setup.
2. Name 2. Move the joystick Left or Right or press OPEN to enter.
3. Pan Start POS 0.0 3. Select Number, move the joystick Left or Right to select the
4. Pan End POS 0.0 number.
5. Tilt Start POS 0.0
IRIS CLOSE to Exit
15
Setup Pan End, Tilt Start, Tilt End according to the above instruction
Sector Setup
1. Number 1
2. Name
3. Pan Start POS 262.0
→4. Pan End POS 0.0
5. Tilt Start POS 0.0
IRIS CLOSE to Exit
16
Coordinates Crosshairs
17
Steps:
Set Default Function
Move the joystick Up or Down to move the cursor to select Restore Def.
→1. Set Default Function P
Move the joystick Left or Right to setup PreShot Position/ PTZ tour/
2. Number 1
Vector scan
3. Delay 60
Select Number and press OPEN to enter Function Numbering setting.
4. Operation Off
Edit Function Number (Refer to Number Instruction)
IRIS CLOSE to Exit
Set delay time (1-999) (Refer to Number Instruction)
Move the joystick Left or Right or press OPEN to On/Off the function.
Instruction:
Control Options
Speed Limit: The speed lowers based on the ratio between moving speed
1. Set Pan and Tilt
of the dome and camera zooming.
2. Set Default Function
Auto Flip: When the lens of the camera makes 90 degree tilt action
→3. Speed Limit On
downward, whether it makes 180 degree auto pan flip then auto tracking
4. Auto Flip On
forward with 10 degree tilt action.
5. Auto Focus PTZ
Auto Focus: If the camera is AF when setup the dome in pan/tilt/zoom
6. Auto AE PTZ
action.
7. Vector Scan AF Off
Auto AE: If the camera is AE when setup the dome in pan/tilt/zoom
8. Vector Scan Still Off
action.
IRIS CLOSE to Exit
Vector Scan AF: If the camera is AF when it is running Vector Scan AF.
4.5 Diagnostic Options
Clear Memory
Function; Clear all memory (but can not clear function of dome).
Diagnostic Options Steps:
→1. Clear Memory Move the joystick Up or Down to move the cursor to select Clear Memory.
2. Restore Def. Setting Move the joystick Left or Right or press OPEN to enter.
3. Color System PAL Press OPEN to reconfirm. Press CLOSE to cancel it and return to the menu.
4. Dome Information
IRIS CLOSE to Exit
18
- - - - - - - - VSD - - - - - - - -
Function:User can setup the functions of the camera accordingly.
1. Language English
Steps:
2. Display Options
1. Move the joystick Up or Down to move selection Camera Options.
3. Control Options
2. Move the joystick Left or Right to press OPEN to enter.
4. Diagnostic Options
→5. Camera Options
6. Function Programming
IRIS CLOSE to Exit
Steps:
Camera Options
1. Move the joystick Up or Down to select the desired option setting.
→1. Camera Name
2. Zoom and Focus 2. Move the joystick Left or Right to select or press OPEN to enter.
3. Camera Exposure
4. Mask Zone
5. Mask Color
6. Others
IRIS CLOSE to Exit
19
21
Camera Options
1. Camera Name Function: User can mask the zone and protect the mask area.
2. Zoom and Focus
3. Camera Exposure
→4. Mask Zone 1. Number
5. Mask Color Steps:
6. Others 1) Move the joystick to move the cursor to select Number.
IRIS CLOSE to Exit
2) Move the joystick Left or Right to select desired editing mask zone
(1-24).
2. Mask Zone:
Mask Zone 1) Move the joystick Up or Down to move the cursor to select Mask
→1. Number 1 Zone.
2. Mask Edit 2) Move the joystick Left or Right or press OPEN enter and program.
3. Mask Display Off 3) Press CLOSE when done.
IRIS CLOSE to Exit
Mask Zone
1. Number 1 +
→2. Mask Edit Press OPEN to start
3. Mask Display Off Press CLOSE to cancel
IRIS CLOSE to Exit
3. Mask Display
Mask Zone Step: Move the joystick Left or Right to start or close Mask Display
1. Number 1
2. Mask Edit
→3. Mask Display Off
IRIS CLOSE to Exit
Mask Color
Mask Color
→1. Mask Color Red 1. Mask Color
2. Semi-transparency On/Off Steps:
IRIS CLOSE to Exit 1) Move the joystick Up or Down to move the cursor to select
Color Setting of Camera.
2) Move the joystick Left or Right to move the cursor to select
Mask Color Setting.
22
Others
Others
→1.Sharpness 0
2. Back Light Off
3. WB Mode Auto
4. R Gain Auto
5. B Gain Auto
6. Vertical Mirror Off
7. Horizontal Mirror Off
8. IR SW Mode Auto
9. Stabilization Off
10. Function OSD On
11. Line Sync Off
IRIS CLOSE to Exit
23
Attention: Disable the command of Vector Scan before you enter into main menu.
24
25
signals such as surge, but it is also necessary to abide by the following precautions to ensure electrical safety based on
practical circumstances:
z Keep the communication cables at least 50 meters away from high voltage equipment or cables.
z Make outdoor cable laying-out under eaves as possible as you can.
z In open area shield cables in steel tube and conduct a single point ground to the tube. Trolley wire is forbidden in such
circumstances.
z In strong thunderstorm or high faradic zone (such as high voltage transformer substation), extra strong lightning
arresters equipment must be installed.
z Take the building lightning proof requirements into account to design the lightning arrestors and grounding of outdoor
equipment and cable laying-out in accordance with the national and industrial standards.
z The system must be grounded with equal potentials. The earth ground connection must satisfy the anti-interference and
electrical safety requirements and must not short circuit with high voltage electricity net. When the system is grounded
separately, the resistance of down conductor should be ≤ 4Ω and the sectional area of down conductor should be
≤25mm2.
Video cable
lightning conductor
28